{{#Wiki_filter:August 7, 2009 Mr. Richard L. Anderson Vice President, Duane Arnold Energy Center FPL Energy Duane Arnold, LLC 3277 DAEC Road Palo, IA 52324  
{{#Wiki_filter:August 7, 2009 Mr. Richard L. Anderson Vice President, Duane Arnold Energy Center FPL Energy Duane Arnold, LLC 3277 DAEC Road Palo, IA 52324


==SUBJECT:==
==SUBJECT:==
REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE DUANE ARNOLD ENERGY CENTER LICENSE RENEWAL APPLICATION - SECTION 2.3 (TAC NO. MD9769)  
REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE DUANE ARNOLD ENERGY CENTER LICENSE RENEWAL APPLICATION -
SECTION 2.3 (TAC NO. MD9769)


==Dear Mr. Anderson:==
==Dear Mr. Anderson:==


By letter dated September 30, 2008, as supplemented by letter dated January 23, 2009, FPL Energy Duane Arnold, LLC, submitted an application for renewal of operating license DPR-49 for the Duane Arnold Energy Center. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, "Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants.During its review, the staff has identified areas where additional information is needed to complete the review. The staff's requests for additional information are included in the enclosure. Further requests for additional information may be issued in the future.
By letter dated September 30, 2008, as supplemented by letter dated January 23, 2009, FPL Energy Duane Arnold, LLC, submitted an application for renewal of operating license DPR-49 for the Duane Arnold Energy Center. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants. During its review, the staff has identified areas where additional information is needed to complete the review. The staffs requests for additional information are included in the enclosure. Further requests for additional information may be issued in the future.
Items in the enclosure were discussed with Mr. Ken Putnam, of your staff, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-3137 or by e-mail at Maurice.Heath@nrc.gov. Sincerely,       /RA/                     Maurice L. Heath, Project Manager       Projects Branch 1     Division of License Renewal       Office of Nuclear Reactor Regulation Docket No. 50-331  
Items in the enclosure were discussed with Mr. Ken Putnam, of your staff, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-3137 or by e-mail at Maurice.Heath@nrc.gov.
Sincerely,
                                              /RA/
Maurice L. Heath, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-331


==Enclosure:==
==Enclosure:==
As stated


cc w/encl: See next page August 7, 2009 Mr. Richard L. Anderson Vice President, Duane Arnold Energy Center FPL Energy Duane Arnold, LLC 3277 DAEC Road Palo, IA 52324  
As stated cc w/encl: See next page
 
August 7, 2009 Mr. Richard L. Anderson Vice President, Duane Arnold Energy Center FPL Energy Duane Arnold, LLC 3277 DAEC Road Palo, IA 52324


==SUBJECT:==
==SUBJECT:==
REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE DUANE ARNOLD ENERGY CENTER LICENSE RENEWAL APPLICATION - SECTION 2.3 (TAC NO. MD9769)  
REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE DUANE ARNOLD ENERGY CENTER LICENSE RENEWAL APPLICATION -
SECTION 2.3 (TAC NO. MD9769)


==Dear Mr. Anderson:==
==Dear Mr. Anderson:==


By letter dated September 30, 2008, as supplemented by letter dated January 23, 2009, FPL Energy Duane Arnold, LLC, submitted an application for renewal of operating license DPR-49 for the Duane Arnold Energy Center. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, "Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants.During its review, the staff has identified areas where additional information is needed to complete the review. The staff's requests for additional information are included in the enclosure. Further requests for additional information may be issued in the future.
By letter dated September 30, 2008, as supplemented by letter dated January 23, 2009, FPL Energy Duane Arnold, LLC, submitted an application for renewal of operating license DPR-49 for the Duane Arnold Energy Center. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants. During its review, the staff has identified areas where additional information is needed to complete the review. The staffs requests for additional information are included in the enclosure. Further requests for additional information may be issued in the future.
Items in the enclosure were discussed with Mr. Ken Putnam, of your staff, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-3137 or by e-mail at Maurice.Heath@nrc.gov. Sincerely,       /RA/                     Maurice L. Heath, Project Manager       Projects Branch 1     Division of License Renewal       Office of Nuclear Reactor Regulation DISTRIBUTION
Items in the enclosure were discussed with Mr. Ken Putnam, of your staff, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-3137 or by e-mail at Maurice.Heath@nrc.gov.
: See next page ADAMS Accession Number: ML092120539 OFFICE LA:DLR PM:RPB1:DLR BC:RPB1:DLR PM:RPB1:DLR NAME IKing MHeath DPelton MHeath (Signature) (DPelton for) DATE 08/06/09 08/07/09 08/07/09 08/07/09 OFFICIAL RECORD COPY Letter to Richard L. Anderson from Maurice L. Heath dated August 07, 2009  
Sincerely,
                                              /RA/
Maurice L. Heath, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation DISTRIBUTION:
See next page ADAMS Accession Number: ML092120539 OFFICE     LA:DLR           PM:RPB1:DLR         BC:RPB1:DLR               PM:RPB1:DLR NAME       IKing             MHeath               DPelton                   MHeath (Signature)
(DPelton for)
DATE       08/06/09         08/07/09             08/07/09                 08/07/09 OFFICIAL RECORD COPY
 
Letter to Richard L. Anderson from Maurice L. Heath dated August 07, 2009


==SUBJECT:==
==SUBJECT:==
REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE DUANE ARNOLD ENERGY CENTER LICENSE RENEWAL APPLICATION - SECTION 2.3 (TAC NO. MD9769)  
REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE DUANE ARNOLD ENERGY CENTER LICENSE RENEWAL APPLICATION -
 
SECTION 2.3 (TAC NO. MD9769)
DISTRIBUTION
DISTRIBUTION:
:
HARD COPY:
HARD COPY: DLR RF E-MAIL: PUBLIC RidsNrrDlrResource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRer1 Resource RidsNrrDlrRer2 Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource RidsNrrDciCvib Resource RidsNrrDciCpnb Resource RidsNrrDciCsgb Resource RidsNrrDraAfpb Resource RidsNrrDraApla Resource RidsNrrDeEmcb Resource RidsNrrDeEeeb Resource RidsNrrDssSrxb Resource RidsNrrDssSbpb Resource RidsNrrDssScvb Resource RidsOgcMailCenter Resource ------------- M. Heath C. Eccelston M. Baty K. Feintuch Duane Arnold Energy Center cc:    Mr. M. S. Ross Managing Attorney Florida Power & Light Company P.O. Box 14000 Juno Beach, FL  33408-0420 Ms. Marjan Mashhadi Senior Attorney Florida Power & Light Company 801 Pennsylvania Avenue, NW Suite 220 Washington, DC  20004 T. O. Jones Vice President, Nuclear Operations Mid-West Region  Florida Power & Light Company P.O. Box 14000 Juno Beach, FL  33408
DLR RF E-MAIL:
 
PUBLIC RidsNrrDlrResource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRer1 Resource RidsNrrDlrRer2 Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource RidsNrrDciCvib Resource RidsNrrDciCpnb Resource RidsNrrDciCsgb Resource RidsNrrDraAfpb Resource RidsNrrDraApla Resource RidsNrrDeEmcb Resource RidsNrrDeEeeb Resource RidsNrrDssSrxb Resource RidsNrrDssSbpb Resource RidsNrrDssScvb Resource RidsOgcMailCenter Resource
Steven R. Catron Manager, Regulatory Affairs Duane Arnold Energy Center 3277 DAEC Road Palo, IA  52324 U.S. Nuclear Regulatory Commission Resident Inspector
-------------
=s Office Rural Route #1 Palo, IA  52324 Mr. Mano Nazar Senior Vice President and  Nuclear Chief Operating Officer Florida Power & Light Company P.O. Box 14000 Juno Beach, FL  33408
M. Heath C. Eccelston M. Baty K. Feintuch


Mr. D. A. Curtland Plant Manager Duane Arnold Energy Center 3277 DAEC Road Palo, IA 52324-9785  
Duane Arnold Energy Center cc:
Mr. M. S. Ross                      Abdy Khanpour Managing Attorney                    Vice President, Engineering Support Florida Power & Light Company        Florida Power & Light Company P.O. Box 14000                      P.O. Box 14000 Juno Beach, FL 33408-0420            Juno Beach, FL 33408 Ms. Marjan Mashhadi                  Ms. Melanie Rasmusson Senior Attorney                      Iowa Department of Public Health Florida Power & Light Company        Bureau of Radiological Health 801 Pennsylvania Avenue, NW          321 East 12th Street Suite 220                            Lucas State Office Building, 5th Floor Washington, DC 20004                Des Moines, IA 50319-0075 T. O. Jones                          Chairman, Linn County Vice President, Nuclear Operations  Board of Supervisors Mid-West Region                      930 1st Street SW Florida Power & Light Company        Cedar Rapids, IA 52404 P.O. Box 14000 Juno Beach, FL 33408                Mr. Peter Wells, Acting Vice President, Nuclear Steven R. Catron                    Training and Performance Improvement Manager, Regulatory Affairs          Florida Power & Light Company Duane Arnold Energy Center          P.O. Box 14000 3277 DAEC Road                      Juno Beach, FL 33408-0420 Palo, IA 52324 Mr. Mark E. Warner U.S. Nuclear Regulatory Commission  Vice President, Nuclear Plant Support Resident Inspector=s Office          Florida Power & Light Company Rural Route #1                      P.O. Box 14000 Palo, IA 52324                      Juno Beach, FL 33408-0420 Mr. Mano Nazar Senior Vice President and Nuclear Chief Operating Officer Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408 Mr. D. A. Curtland Plant Manager Duane Arnold Energy Center 3277 DAEC Road Palo, IA 52324-9785


Abdy Khanpour Vice President, Engineering Support Florida Power & Light Company P.O. Box 14000 Juno Beach, FL  33408 Ms. Melanie Rasmusson Iowa Department of Public Health Bureau of Radiological Health 321 East 12th Street Lucas State Office Building, 5th Floor Des Moines, IA  50319-0075 Chairman, Linn County Board of Supervisors 930 1st Street SW Cedar Rapids, IA  52404 Mr. Peter Wells, Acting Vice President, Nuclear Training and Performance Improvement Florida Power & Light Company P.O. Box 14000 Juno Beach, FL  33408-0420
DUANE ARNOLD ENERGY CENTER LICENSE RENEWAL APPLICATION REQUEST FOR ADDITIONAL INFORMATION SECTION 2.3 RAI 2.3.2.6-1 Duane Arnold Energy Center (DAEC) Standby Gas Treatment System described in license renewal application (LRA) Section 2.3.2.6 and on LRA Drawings BECH-M122-LR, BECH-M124-LR, BECH-M143(1)-LR, BECH-M158-LR, BECH-M164-LR, BECH-M165-LR, BECHM-172-LR, BECH-M176 (1)-LR, BECH-M176(2)-LR, and BECH-M182-LR, and LRA Table 2.3.2-6, Standby Gas Treatment System, does not contain all the component types of the Standby Gas Treatment System highlighted on the drawings. For example, while the table lists component types for drip pans, fasteners, filters, piping, valve body, etc., it does not list bolting, washers and nuts, screens and strainer, damper, damper housing, fire damper housing, valve (also valve body not listed in LRA Table 3.2.2-6), nor exhaust fan housing.
 
Additionally, LRA Table 3.2.2-6, Summary of Aging Management Review Results-Standy Gas Treatment System, does not list the component types for damper housings, fire damper housings, nor exhaust fan housings.
Mr. Mark E. Warner Vice President, Nuclear Plant Support Florida Power & Light Company P.O. Box 14000 Juno Beach, FL  33408-0420
 
ENCLOSURE DUANE ARNOLD ENERGY CENTER LICENSE RENEWAL APPLICATION REQUEST FOR ADDITIONAL INFORMATION SECTION 2.3 RAI 2.3.2.6-1 Duane Arnold Energy Center (DAEC) Standby Gas Treatment System described in license renewal application (LRA) Section 2.3.2.6 and on LRA Drawings BECH-M122-LR, BECH-M124-LR, BECH-M143(1)-LR, BECH-M158-LR, BECH-M164-LR, BECH-M165-LR, BECHM-172-LR, BECH-M176 (1)-LR, BECH-M176(2)-LR, and BECH-M182-LR, and LRA Table 2.3.2-6, Standby Gas Treatment System, does not contain all the component types of the Standby Gas Treatment System highlighted on the drawings. For example, while the table lists component types for drip pans, fasteners, filters, piping, valve body, etc., it does not list bolting, washers and nuts, screens and strainer, damper, damper housing, fire damper housing, valve (also valve body not listed in LRA Table 3.2.2-6), nor exhaust fan housing.  
 
Additionally, LRA Table 3.2.2-6, "Summary of Aging Management Review Results-Standy Gas Treatment System," does not list the component types for damper housings, fire damper housings, nor exhaust fan housings.
Clarify whether these component types and all other applicable components of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an aging management review (AMR) in accordance with 10 CFR 54.21(a)(1). If these component types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables. If these component types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.
Clarify whether these component types and all other applicable components of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an aging management review (AMR) in accordance with 10 CFR 54.21(a)(1). If these component types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables. If these component types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.
RAI 2.3.3.6-1 DAEC Building Heating, Ventilation, and Air Conditioning described in LRA Section 2.3.3.6 and on LRA Drawings BECH-M161-LR, BECH-M169(1)-LR, BECH-M169(2)-LR, BECH-M169(3)-LR, BECH-M170-LR, and BECH-M173-LR, and LRA Table 2.3.3-6, "Control Building Heating, Ventilation, and Air Conditioning," does not contain all the component types of the Control Building Heating, Ventilation and Air Conditioning as highlighted on the drawings. For example, while the table lists component types for pressure vessel, blower, drip pans, ductwork, heater housing, fasteners, filters, piping, valve body, etc., it does not list component types for accumulator, pulsation damper, low pressure tank, housings for pulsation damper, blower/fan, and vacuum pump, drain pans, electrical heater housing, bolting, washers and nuts, filter housing, screens and strainers, housings for condenser, cooler, heating and cooling coils, pipe fittings, hoses, tubes, rupture disk, housings for positive pressure devices, fire damper housings, nor damper housing.
RAI 2.3.3.6-1 DAEC Building Heating, Ventilation, and Air Conditioning described in LRA Section 2.3.3.6 and on LRA Drawings BECH-M161-LR, BECH-M169(1)-LR, BECH-M169(2)-LR, BECH-M169(3)-
Additionally, LRA Table 3.3.2-6, "Summary of Aging Management Review Results-Control Building Heating, Ventilation, and Air Conditioning," does not list the component types for housings for pulsation damper and blower/fan, casing for vacuum pump, drip pans, electrical heater housing, filter housing, housings for condenser, cooler, heating and cooling coils, housings for positive pressure devices, fire damper housings, nor damper housings.
LR, BECH-M170-LR, and BECH-M173-LR, and LRA Table 2.3.3-6, "Control Building Heating, Ventilation, and Air Conditioning," does not contain all the component types of the Control Building Heating, Ventilation and Air Conditioning as highlighted on the drawings. For example, while the table lists component types for pressure vessel, blower, drip pans, ductwork, heater housing, fasteners, filters, piping, valve body, etc., it does not list component types for accumulator, pulsation damper, low pressure tank, housings for pulsation damper, blower/fan, and vacuum pump, drain pans, electrical heater housing, bolting, washers and nuts, filter housing, screens and strainers, housings for condenser, cooler, heating and cooling coils, pipe fittings, hoses, tubes, rupture disk, housings for positive pressure devices, fire damper housings, nor damper housing.
Clarify whether these component types, and all other applicable component types of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If these component types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables. If these component types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.
ENCLOSURE
 
RAI 2.3.3.18-1 DAEC Plant Ventilation described in LRA Section 2.3.3.18 and on LRA Drawings BECH-M159-LR, BECH-M160(1)-LR, BECH-M163-LR, BECH-M164-LR, BECH-M170-LR, BECH-M175-LR, BECH-M177-LR, and LRA Table 2.3.3-18, APlant Ventilation,@ does not contain all the component types of the Plant Ventilation highlighted on the drawings. For example, while the table lists component types, damper casings (housings), ductwork, fasteners, filters, pump casings, valve body, etc., it does not list component types for blower and fan housings, casings for compressor and vacuum pump, fire damper housings, drain pans, bolting, washers and nuts, filter housing, screens and strainers, housings for condenser and cooler, fan, heating and cooling coils, pipe fittings, hoses, tubes, rupture disk, nor housings for positive pressure devices. Additionally, LRA Table 3.3.2-18, "Summary of Aging Management Review Results-Plant Ventilation," does not list the component types for blower housings, fan housings, vacuum pump casing, drip pans, filter housing, housings for condenser, cooler, fan, heating and cooling coils, pump casing, housings for positive pressure devices, valve bodies, fire damper housings nor damper housings.
Clarify whether these component types and all other applicable component types of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If these components types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables. If these components types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.
 
RAI 2.3.3.20-1
 
DAEC Primary Containment Heating, Ventilation, and Air Conditioning described in LRA Section 2.3.3.20 and on LRA Drawings BECH-M144-LR, BECH-M157(1)-LR, BECH-M157(2)(1)-LR, and LRA Table 2.3.3-20, APrimary Containment Heating, Ventilation, and Air Conditioning,@ does not contain all the component types of the Primary Containment Heating, Ventilation, and Air Conditioning highlighted on the drawings. For example, while the table lists component types for fasteners, filters, heat exchanger, valve body, etc., it does not list component types for piping that include pipe Class 1, pipe fittings, and tubing, bolting, washers and nuts, pipe fittings, hoses, tubes, rupture disk, housings for positive pressure devices, fan coil housings, housings for filters, screens, and strainer, fire damper housings, nor  damper housing. 
 
Additionally, LRA Table 3.3.2-20, "Sumary of Aging Management Review Results-Primary Containment Heating, Ventilation, and Air Conditioning" does not list the component types for casings for pumps and housings for positive devices, housings for filters, screens, strainer, fan coil housings, valve bodies, fire damper housings nor damper housings.


Clarify whether these component types and all other applicable component types of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If these component types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables. If these component types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.  
Additionally, LRA Table 3.3.2-6, Summary of Aging Management Review Results-Control Building Heating, Ventilation, and Air Conditioning, does not list the component types for housings for pulsation damper and blower/fan, casing for vacuum pump, drip pans, electrical heater housing, filter housing, housings for condenser, cooler, heating and cooling coils, housings for positive pressure devices, fire damper housings, nor damper housings.
Clarify whether these component types, and all other applicable component types of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If these component types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables. If these component types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.
RAI 2.3.3.18-1 DAEC Plant Ventilation described in LRA Section 2.3.3.18 and on LRA Drawings BECH-M159-LR, BECH-M160(1)-LR, BECH-M163-LR, BECH-M164-LR, BECH-M170-LR, BECH-M175-LR, BECH-M177-LR, and LRA Table 2.3.3-18, APlant Ventilation,@ does not contain all the component types of the Plant Ventilation highlighted on the drawings. For example, while the table lists component types, damper casings (housings), ductwork, fasteners, filters, pump casings, valve body, etc., it does not list component types for blower and fan housings, casings for compressor and vacuum pump, fire damper housings, drain pans, bolting, washers and nuts, filter housing, screens and strainers, housings for condenser and cooler, fan, heating and cooling coils, pipe fittings, hoses, tubes, rupture disk, nor housings for positive pressure devices.
Additionally, LRA Table 3.3.2-18, Summary of Aging Management Review Results-Plant Ventilation, does not list the component types for blower housings, fan housings, vacuum pump casing, drip pans, filter housing, housings for condenser, cooler, fan, heating and cooling coils, pump casing, housings for positive pressure devices, valve bodies, fire damper housings nor damper housings.
Clarify whether these component types and all other applicable component types of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If these components types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables. If these components types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.


RAI 2.3.3.23-1
RAI 2.3.3.20-1 DAEC Primary Containment Heating, Ventilation, and Air Conditioning described in LRA Section 2.3.3.20 and on LRA Drawings BECH-M144-LR, BECH-M157(1)-LR, BECH-M157(2)(1)-LR, and LRA Table 2.3.3-20, APrimary Containment Heating, Ventilation, and Air Conditioning,@ does not contain all the component types of the Primary Containment Heating, Ventilation, and Air Conditioning highlighted on the drawings. For example, while the table lists component types for fasteners, filters, heat exchanger, valve body, etc., it does not list component types for piping that include pipe Class 1, pipe fittings, and tubing, bolting, washers and nuts, pipe fittings, hoses, tubes, rupture disk, housings for positive pressure devices, fan coil housings, housings for filters, screens, and strainer, fire damper housings, nor damper housing.
Additionally, LRA Table 3.3.2-20, Sumary of Aging Management Review Results-Primary Containment Heating, Ventilation, and Air Conditioning does not list the component types for casings for pumps and housings for positive devices, housings for filters, screens, strainer, fan coil housings, valve bodies, fire damper housings nor damper housings.
Clarify whether these component types and all other applicable component types of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If these component types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables. If these component types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.
RAI 2.3.3.23-1 DAEC Reactor Building Heating, Ventilation, and Air Conditioning described in LRA Section 2.3.3.23 and on LRA Drawings BECHM-111-LR, BECHM-152-LR, BECH-M160(1)-LR, BECH-M162-LR, BECH-M165-LR, BECH-M166-LR, BECH-M170-LR, BECH-M171-LR, and LRA Table 2.3.3-23, AReactor Building Heating, Ventilation, and Air Conditioning,@ does not contain all the component types of the Reactor Building Heating, Ventilation, and Air Conditioning highlighted on the drawings. For example, while the table lists component types for pressure vessel, drip pans, ductwork, fasteners, heat exchanger, piping, valve body, etc., it does not list component types for accumulator housing, pulsation damper housing, and low pressure tank housing, bolting, washers and nuts, pipe fittings, hoses, tubes, rupture disk, housings for positive pressure devices (housings for separators and degasifiers (also not listed in Table 3.3.2-23), fire damper housings, fan housings, filter housings, nor damper housing (also not listed in Table 3.3.2-23).
Additionally, LRA Table 3.3.2-23, Summary of Aging management Review Results-Reactor Building Heating, Ventilation, and Air-Conditioning does not list the component types for accumulator housing, pulsation damper housing and low pressure tank housing, pump casings, housings for positive pressure devices, fan housings, filter housings, fire damper housings, nor damper housings.


DAEC Reactor Building Heating, Ventilation, and Air Conditioning described in LRA Section 2.3.3.23 and on LRA Drawings BECHM-111-LR, BECHM-152-LR, BECH-M160(1)-LR, BECH-M162-LR, BECH-M165-LR, BECH-M166-LR, BECH-M170-LR, BECH-M171-LR, and LRA Table 2.3.3-23, AReactor Building Heating, Ventilation, and Air Conditioning,@ does not contain all the component types of the Reactor Building Heating, Ventilation, and Air Conditioning highlighted on the drawings. For example, while the table lists component types for pressure vessel, drip pans, ductwork, fasteners, heat exchanger, piping, valve body, etc., it does not list component types for accumulator housing, pulsation damper housing, and low pressure tank housing, bolting, washers and nuts, pipe fittings, hoses, tubes, rupture disk, housings for positive pressure devices (housings for separators and degasifiers (also not listed in Table 3.3.2-23), fire damper housings, fan housings, filter housings, nor damper housing (also not listed in Table 3.3.2-23).
Clarify whether these component types and all other applicable component types of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to aging management review in accordance with 10 CFR 54.21(a)(1). If these component types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables.
Additionally, LRA Table 3.3.2-23, "Summary of Aging management Review Results-Reactor Building Heating, Ventilation, and Air-Conditioning" does not list the component types for accumulator housing, pulsation damper housing and low pressure tank housing, pump casings, housings for positive pressure devices, fan housings, filter housings, fire damper housings, nor damper housings.
If these component types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.}}
Clarify whether these component types and all other applicable component types of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to aging management review in accordance with 10 CFR 54.21(a)(1). If these component types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables. If these component types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.}}

Latest revision as of 03:40, 14 November 2019

Request for Additional Information for the Review of the Duane Arnold Energy Center License Renewal Application - Section 2.3
ML092120539
Person / Time
Site: Duane Arnold NextEra Energy icon.png
Issue date: 08/07/2009
From: Maurice Heath
License Renewal Projects Branch 1
To: Richard Anderson
Duane Arnold
Heath, M, NRR/DLR/RPB1, 415-3137
References
TAC MD9769
Download: ML092120539 (8)


Text

August 7, 2009 Mr. Richard L. Anderson Vice President, Duane Arnold Energy Center FPL Energy Duane Arnold, LLC 3277 DAEC Road Palo, IA 52324

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE DUANE ARNOLD ENERGY CENTER LICENSE RENEWAL APPLICATION -

SECTION 2.3 (TAC NO. MD9769)

Dear Mr. Anderson:

By letter dated September 30, 2008, as supplemented by letter dated January 23, 2009, FPL Energy Duane Arnold, LLC, submitted an application for renewal of operating license DPR-49 for the Duane Arnold Energy Center. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants. During its review, the staff has identified areas where additional information is needed to complete the review. The staffs requests for additional information are included in the enclosure. Further requests for additional information may be issued in the future.

Items in the enclosure were discussed with Mr. Ken Putnam, of your staff, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-3137 or by e-mail at Maurice.Heath@nrc.gov.

Sincerely,

/RA/

Maurice L. Heath, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket No. 50-331

Enclosure:

As stated cc w/encl: See next page

August 7, 2009 Mr. Richard L. Anderson Vice President, Duane Arnold Energy Center FPL Energy Duane Arnold, LLC 3277 DAEC Road Palo, IA 52324

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE DUANE ARNOLD ENERGY CENTER LICENSE RENEWAL APPLICATION -

SECTION 2.3 (TAC NO. MD9769)

Dear Mr. Anderson:

By letter dated September 30, 2008, as supplemented by letter dated January 23, 2009, FPL Energy Duane Arnold, LLC, submitted an application for renewal of operating license DPR-49 for the Duane Arnold Energy Center. The staff of the U.S. Nuclear Regulatory Commission (NRC or the staff) is reviewing this application in accordance with the guidance in NUREG-1800, Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants. During its review, the staff has identified areas where additional information is needed to complete the review. The staffs requests for additional information are included in the enclosure. Further requests for additional information may be issued in the future.

Items in the enclosure were discussed with Mr. Ken Putnam, of your staff, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me by telephone at 301-415-3137 or by e-mail at Maurice.Heath@nrc.gov.

Sincerely,

/RA/

Maurice L. Heath, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation DISTRIBUTION:

See next page ADAMS Accession Number: ML092120539 OFFICE LA:DLR PM:RPB1:DLR BC:RPB1:DLR PM:RPB1:DLR NAME IKing MHeath DPelton MHeath (Signature)

(DPelton for)

DATE 08/06/09 08/07/09 08/07/09 08/07/09 OFFICIAL RECORD COPY

Letter to Richard L. Anderson from Maurice L. Heath dated August 07, 2009

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE DUANE ARNOLD ENERGY CENTER LICENSE RENEWAL APPLICATION -

SECTION 2.3 (TAC NO. MD9769)

DISTRIBUTION:

HARD COPY:

DLR RF E-MAIL:

PUBLIC RidsNrrDlrResource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRer1 Resource RidsNrrDlrRer2 Resource RidsNrrDlrRerb Resource RidsNrrDlrRpob Resource RidsNrrDciCvib Resource RidsNrrDciCpnb Resource RidsNrrDciCsgb Resource RidsNrrDraAfpb Resource RidsNrrDraApla Resource RidsNrrDeEmcb Resource RidsNrrDeEeeb Resource RidsNrrDssSrxb Resource RidsNrrDssSbpb Resource RidsNrrDssScvb Resource RidsOgcMailCenter Resource


M. Heath C. Eccelston M. Baty K. Feintuch

Duane Arnold Energy Center cc:

Mr. M. S. Ross Abdy Khanpour Managing Attorney Vice President, Engineering Support Florida Power & Light Company Florida Power & Light Company P.O. Box 14000 P.O. Box 14000 Juno Beach, FL 33408-0420 Juno Beach, FL 33408 Ms. Marjan Mashhadi Ms. Melanie Rasmusson Senior Attorney Iowa Department of Public Health Florida Power & Light Company Bureau of Radiological Health 801 Pennsylvania Avenue, NW 321 East 12th Street Suite 220 Lucas State Office Building, 5th Floor Washington, DC 20004 Des Moines, IA 50319-0075 T. O. Jones Chairman, Linn County Vice President, Nuclear Operations Board of Supervisors Mid-West Region 930 1st Street SW Florida Power & Light Company Cedar Rapids, IA 52404 P.O. Box 14000 Juno Beach, FL 33408 Mr. Peter Wells, Acting Vice President, Nuclear Steven R. Catron Training and Performance Improvement Manager, Regulatory Affairs Florida Power & Light Company Duane Arnold Energy Center P.O. Box 14000 3277 DAEC Road Juno Beach, FL 33408-0420 Palo, IA 52324 Mr. Mark E. Warner U.S. Nuclear Regulatory Commission Vice President, Nuclear Plant Support Resident Inspector=s Office Florida Power & Light Company Rural Route #1 P.O. Box 14000 Palo, IA 52324 Juno Beach, FL 33408-0420 Mr. Mano Nazar Senior Vice President and Nuclear Chief Operating Officer Florida Power & Light Company P.O. Box 14000 Juno Beach, FL 33408 Mr. D. A. Curtland Plant Manager Duane Arnold Energy Center 3277 DAEC Road Palo, IA 52324-9785

DUANE ARNOLD ENERGY CENTER LICENSE RENEWAL APPLICATION REQUEST FOR ADDITIONAL INFORMATION SECTION 2.3 RAI 2.3.2.6-1 Duane Arnold Energy Center (DAEC) Standby Gas Treatment System described in license renewal application (LRA) Section 2.3.2.6 and on LRA Drawings BECH-M122-LR, BECH-M124-LR, BECH-M143(1)-LR, BECH-M158-LR, BECH-M164-LR, BECH-M165-LR, BECHM-172-LR, BECH-M176 (1)-LR, BECH-M176(2)-LR, and BECH-M182-LR, and LRA Table 2.3.2-6, Standby Gas Treatment System, does not contain all the component types of the Standby Gas Treatment System highlighted on the drawings. For example, while the table lists component types for drip pans, fasteners, filters, piping, valve body, etc., it does not list bolting, washers and nuts, screens and strainer, damper, damper housing, fire damper housing, valve (also valve body not listed in LRA Table 3.2.2-6), nor exhaust fan housing.

Additionally, LRA Table 3.2.2-6, Summary of Aging Management Review Results-Standy Gas Treatment System, does not list the component types for damper housings, fire damper housings, nor exhaust fan housings.

Clarify whether these component types and all other applicable components of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an aging management review (AMR) in accordance with 10 CFR 54.21(a)(1). If these component types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables. If these component types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.

RAI 2.3.3.6-1 DAEC Building Heating, Ventilation, and Air Conditioning described in LRA Section 2.3.3.6 and on LRA Drawings BECH-M161-LR, BECH-M169(1)-LR, BECH-M169(2)-LR, BECH-M169(3)-

LR, BECH-M170-LR, and BECH-M173-LR, and LRA Table 2.3.3-6, "Control Building Heating, Ventilation, and Air Conditioning," does not contain all the component types of the Control Building Heating, Ventilation and Air Conditioning as highlighted on the drawings. For example, while the table lists component types for pressure vessel, blower, drip pans, ductwork, heater housing, fasteners, filters, piping, valve body, etc., it does not list component types for accumulator, pulsation damper, low pressure tank, housings for pulsation damper, blower/fan, and vacuum pump, drain pans, electrical heater housing, bolting, washers and nuts, filter housing, screens and strainers, housings for condenser, cooler, heating and cooling coils, pipe fittings, hoses, tubes, rupture disk, housings for positive pressure devices, fire damper housings, nor damper housing.

ENCLOSURE

Additionally, LRA Table 3.3.2-6, Summary of Aging Management Review Results-Control Building Heating, Ventilation, and Air Conditioning, does not list the component types for housings for pulsation damper and blower/fan, casing for vacuum pump, drip pans, electrical heater housing, filter housing, housings for condenser, cooler, heating and cooling coils, housings for positive pressure devices, fire damper housings, nor damper housings.

Clarify whether these component types, and all other applicable component types of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If these component types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables. If these component types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.

RAI 2.3.3.18-1 DAEC Plant Ventilation described in LRA Section 2.3.3.18 and on LRA Drawings BECH-M159-LR, BECH-M160(1)-LR, BECH-M163-LR, BECH-M164-LR, BECH-M170-LR, BECH-M175-LR, BECH-M177-LR, and LRA Table 2.3.3-18, APlant Ventilation,@ does not contain all the component types of the Plant Ventilation highlighted on the drawings. For example, while the table lists component types, damper casings (housings), ductwork, fasteners, filters, pump casings, valve body, etc., it does not list component types for blower and fan housings, casings for compressor and vacuum pump, fire damper housings, drain pans, bolting, washers and nuts, filter housing, screens and strainers, housings for condenser and cooler, fan, heating and cooling coils, pipe fittings, hoses, tubes, rupture disk, nor housings for positive pressure devices.

Additionally, LRA Table 3.3.2-18, Summary of Aging Management Review Results-Plant Ventilation, does not list the component types for blower housings, fan housings, vacuum pump casing, drip pans, filter housing, housings for condenser, cooler, fan, heating and cooling coils, pump casing, housings for positive pressure devices, valve bodies, fire damper housings nor damper housings.

Clarify whether these component types and all other applicable component types of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If these components types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables. If these components types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.

RAI 2.3.3.20-1 DAEC Primary Containment Heating, Ventilation, and Air Conditioning described in LRA Section 2.3.3.20 and on LRA Drawings BECH-M144-LR, BECH-M157(1)-LR, BECH-M157(2)(1)-LR, and LRA Table 2.3.3-20, APrimary Containment Heating, Ventilation, and Air Conditioning,@ does not contain all the component types of the Primary Containment Heating, Ventilation, and Air Conditioning highlighted on the drawings. For example, while the table lists component types for fasteners, filters, heat exchanger, valve body, etc., it does not list component types for piping that include pipe Class 1, pipe fittings, and tubing, bolting, washers and nuts, pipe fittings, hoses, tubes, rupture disk, housings for positive pressure devices, fan coil housings, housings for filters, screens, and strainer, fire damper housings, nor damper housing.

Additionally, LRA Table 3.3.2-20, Sumary of Aging Management Review Results-Primary Containment Heating, Ventilation, and Air Conditioning does not list the component types for casings for pumps and housings for positive devices, housings for filters, screens, strainer, fan coil housings, valve bodies, fire damper housings nor damper housings.

Clarify whether these component types and all other applicable component types of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to an AMR in accordance with 10 CFR 54.21(a)(1). If these component types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables. If these component types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.

RAI 2.3.3.23-1 DAEC Reactor Building Heating, Ventilation, and Air Conditioning described in LRA Section 2.3.3.23 and on LRA Drawings BECHM-111-LR, BECHM-152-LR, BECH-M160(1)-LR, BECH-M162-LR, BECH-M165-LR, BECH-M166-LR, BECH-M170-LR, BECH-M171-LR, and LRA Table 2.3.3-23, AReactor Building Heating, Ventilation, and Air Conditioning,@ does not contain all the component types of the Reactor Building Heating, Ventilation, and Air Conditioning highlighted on the drawings. For example, while the table lists component types for pressure vessel, drip pans, ductwork, fasteners, heat exchanger, piping, valve body, etc., it does not list component types for accumulator housing, pulsation damper housing, and low pressure tank housing, bolting, washers and nuts, pipe fittings, hoses, tubes, rupture disk, housings for positive pressure devices (housings for separators and degasifiers (also not listed in Table 3.3.2-23), fire damper housings, fan housings, filter housings, nor damper housing (also not listed in Table 3.3.2-23).

Additionally, LRA Table 3.3.2-23, Summary of Aging management Review Results-Reactor Building Heating, Ventilation, and Air-Conditioning does not list the component types for accumulator housing, pulsation damper housing and low pressure tank housing, pump casings, housings for positive pressure devices, fan housings, filter housings, fire damper housings, nor damper housings.

Clarify whether these component types and all other applicable component types of the system, including duct sealants, wall sealants, pressure boundary sealants, etc., are within the scope of license renewal in accordance with 10 CFR 54.4(a), and subject to aging management review in accordance with 10 CFR 54.21(a)(1). If these component types are in the scope of license renewal, update the LRA by providing the applicable information in the appropriate LRA tables.

If these component types are excluded from the scope of license renewal and not subject to an AMR, provide justification for the exclusion.