IR 05000390/2009403: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
Line 26: Line 26:
On July 31, 2009, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at your Watts Bar Nuclear Plant, Units 1 and 2. The enclosed inspection report documents the inspection results, which were discussed on July 31, 2009 with Mr. M. Skaggs and other members of your staff.
On July 31, 2009, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at your Watts Bar Nuclear Plant, Units 1 and 2. The enclosed inspection report documents the inspection results, which were discussed on July 31, 2009 with Mr. M. Skaggs and other members of your staff.


The inspection examined activities conducted under your license as they relate to safety and compliance with the Commission's rules and regulations and with the conditions of your license.
The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.


Specifically, the focus of the inspection was Temporary Instruction 2201/002, Inspection of Transition of Contract Security to Proprietary Security Force. The inspector reviewed selected procedures and records, observed activities, and interviewed personnel.
Specifically, the focus of the inspection was Temporary Instruction 2201/002, Inspection of Transition of Contract Security to Proprietary Security Force. The inspector reviewed selected procedures and records, observed activities, and interviewed personnel.
Line 32: Line 32:
Based on the results of this inspection, there were no findings of significance identified.
Based on the results of this inspection, there were no findings of significance identified.


In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system, ADAMS. ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html(the Public Electronic Reading Room). However, because of the security-related concerns contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letter's enclosure will not be available for public inspection.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system, ADAMS. ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html(the Public Electronic Reading Room). However, because of the security-related concerns contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letters enclosure will not be available for public inspection.


In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRC's document system, ADAMS. If Safeguards Information is necessary to provide an acceptable TVA 2 response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire response "Security-Related Information Withhold in accordance with 10 CFR 2.390", and follow the instructions for withholding in 10 CFR 2.390(b)(1).
In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system, ADAMS. If Safeguards Information is necessary to provide an acceptable TVA   2 response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire response Security-Related Information Withhold in accordance with 10 CFR 2.390, and follow the instructions for withholding in 10 CFR 2.390(b)(1).


Sincerely,
Sincerely,
/RA/
/RA/
Michael E. Ernstes, Chief Plant Support Branch 2 Division of Reactor Safety Docket No.: 50-390, 50-391 License No.: NPF-90, Construction Permit No. CPPR-92  
Michael E. Ernstes, Chief Plant Support Branch 2 Division of Reactor Safety Docket No.: 50-390, 50-391 License No.: NPF-90, Construction Permit No. CPPR-92 Enclosure: Inspection Report 05000390/2009403 and 05000391/2009403 w/Attachment: Supplemental Information cc w/encl.: (See page 3) TVA   3 cc w/Encl:   Patrick J. Asendorf Michael D. Skaggs General Manager Site Vice President Nuclear Emergency Services Watts Bar Nuclear Plant Tennessee Valley Authority Tennessee Valley Authority 6B Lookout Place P. O. Box 2000 1101 Market Street Spring City, TN 37381 Chattanooga, TN 37402-2801 Gregory A. Boerschig  Christopher E. Glover Plant Manager   Manager Watts Bar Nuclear Plant  Nuclear Security Operations Tennessee Valley Authority Tennessee Valley Authority P.O. Box 2000   6B Lookout Place Spring City, TN 37381 1101 Market Street Chattanooga, TN 37402-2801 Thomas Coutu Vice President  Kimberley D. Bayles Nuclear Support  (Acting) Site Security Manager Tennessee Valley Authority  Watts Bar Nuclear Plant 3R Lookout Place  Tennessee Valley Authority 1101 Market Street  P.O. Box 2000 Chattanooga, TN 37402-2801  Spring City, TN 37381-2000 Larry E. Nicholson  Ashok S. Bhatnagar General Manager  Senior Vice President Performance Improvement  Nuclear Generation Development and Tennessee Valley Authority  Construction 3R Lookout Place  Tennessee Valley Authority 1101 Market Street  6A Lookout Place Chattanooga, TN 37402-2801  1101 Market Street Chattanooga, TN 37402-2801 Michael A. Purcell Senior Licensing Manager  Masoud Bajestani Nuclear Power Group  Vice President Watts Bar Unit 2 Tennessee Valley Authority  Watts Bar Nuclear Plant 4K Lookout Place  Tennessee Valley Authority 1101 Market Street  P.O. Box 2000 Chattanooga, TN 37402-2801  Spring City, TN 37381 Michael K. Brandon  Gordon P. Arent Manager  New Generation Licensing Manager Licensing and Industry Affairs Watts Bar Nuclear Plant Watts Bar Nuclear Plant  Tennessee Valley Authority Tennessee Valley Authority  P.O. Box 2000 P.O. Box 2000  Spring City, TN 37381 Spring City, TN 37381 _________________________ x SUNSI REVIEW COMPLETE OFFICE RII:DRS RII:DRS RII:DRP RII:DRP RII:DRP SIGNATURE /RA/ /RA/ /RA/
 
NAME M. Ernstes J.Wallo E. Guthrie DATE 8/28/2009 8/28/2009 8/28/2009 E-MAIL COPY? YES NO YES NO YES NO YES NO YES NO YES NO YES NO
Enclosure: Inspection Report 05000390/2009403 and 05000391/2009403 w/Attachment: Supplemental Information  
 
cc w/encl.: (See page 3) TVA 3 cc w/Encl: Michael D. Skaggs Site Vice President Watts Bar Nuclear Plant Tennessee Valley Authority P. O. Box 2000 Spring City, TN 37381
 
Gregory A. Boerschig Plant Manager Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381  
 
Thomas Coutu Vice President Nuclear Support Tennessee Valley Authority 3R Lookout Place 1101 Market Street Chattanooga, TN 37402-2801  
 
Larry E. Nicholson General Manager Performance Improvement Tennessee Valley Authority 3R Lookout Place 1101 Market Street Chattanooga, TN 37402-2801
 
Michael A. Purcell Senior Licensing Manager Nuclear Power Group Tennessee Valley Authority 4K Lookout Place 1101 Market Street Chattanooga, TN 37402-2801
 
Michael K. Brandon Manager Licensing and Industry Affairs Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381  
 
Patrick J. Asendorf General Manager Nuclear Emergency Services Tennessee Valley Authority 6B Lookout Place 1101 Market Street Chattanooga, TN 37402-2801  
 
Christopher E. Glover Manager Nuclear Security Operations Tennessee Valley Authority 6B Lookout Place 1101 Market Street Chattanooga, TN 37402-2801
 
Kimberley D. Bayles (Acting) Site Security Manager Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381-2000  
 
Ashok S. Bhatnagar Senior Vice President Nuclear Generation Development and Construction Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801  
 
Masoud Bajestani Vice President Watts Bar Unit 2 Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381  
 
Gordon P. Arent New Generation Licensing Manager Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381  
 
_________________________ x SUNSI REVIEW COMPLETE OFFICE RII:DRS RII:DRS RII:DRP RII:DRP RII:DRP SIGNATURE /RA/ /RA/ /RA/ NAME M. Ernstes J.Wallo E. Guthrie DATE 8/28/2009 8/28/2009 8/28/2009 E-MAIL COPY? YES NO YES NO YES NO YES NO YES NO YES NO YES NO
}}
}}

Latest revision as of 03:52, 14 November 2019

NRC Security Inspection Report 05000390/2009403 and 05000391/2009403
ML092400058
Person / Time
Site: Watts Bar  Tennessee Valley Authority icon.png
Issue date: 08/28/2009
From: Ernstes M
NRC/RGN-II/DRS/PSB2
To: Swafford P
Tennessee Valley Authority
References
IR-09-403
Download: ML092400058 (4)


Text

ust 28, 2009

SUBJECT:

WATTS BAR NUCLEAR PLANT - NRC SECURITY INSPECTION REPORT 05000390/2009403 AND 05000391/2009403

Dear Mr. Swafford:

On July 31, 2009, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at your Watts Bar Nuclear Plant, Units 1 and 2. The enclosed inspection report documents the inspection results, which were discussed on July 31, 2009 with Mr. M. Skaggs and other members of your staff.

The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.

Specifically, the focus of the inspection was Temporary Instruction 2201/002, Inspection of Transition of Contract Security to Proprietary Security Force. The inspector reviewed selected procedures and records, observed activities, and interviewed personnel.

Based on the results of this inspection, there were no findings of significance identified.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC's document system, ADAMS. ADAMS is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html(the Public Electronic Reading Room). However, because of the security-related concerns contained in the enclosure, and in accordance with 10 CFR 2.390, a copy of this letters enclosure will not be available for public inspection.

In accordance with 10 CFR 2.390(b)(1)(ii), the NRC is waiving the affidavit requirements for your response, if any. This practice will ensure that your response will not be made available electronically for public inspection in the NRC Public Document Room or from the NRCs document system, ADAMS. If Safeguards Information is necessary to provide an acceptable TVA 2 response, please provide the level of protection described in 10 CFR 73.21. Otherwise, mark your entire response Security-Related Information Withhold in accordance with 10 CFR 2.390, and follow the instructions for withholding in 10 CFR 2.390(b)(1).

Sincerely,

/RA/

Michael E. Ernstes, Chief Plant Support Branch 2 Division of Reactor Safety Docket No.: 50-390, 50-391 License No.: NPF-90, Construction Permit No. CPPR-92 Enclosure: Inspection Report 05000390/2009403 and 05000391/2009403 w/Attachment: Supplemental Information cc w/encl.: (See page 3) TVA 3 cc w/Encl: Patrick J. Asendorf Michael D. Skaggs General Manager Site Vice President Nuclear Emergency Services Watts Bar Nuclear Plant Tennessee Valley Authority Tennessee Valley Authority 6B Lookout Place P. O. Box 2000 1101 Market Street Spring City, TN 37381 Chattanooga, TN 37402-2801 Gregory A. Boerschig Christopher E. Glover Plant Manager Manager Watts Bar Nuclear Plant Nuclear Security Operations Tennessee Valley Authority Tennessee Valley Authority P.O. Box 2000 6B Lookout Place Spring City, TN 37381 1101 Market Street Chattanooga, TN 37402-2801 Thomas Coutu Vice President Kimberley D. Bayles Nuclear Support (Acting) Site Security Manager Tennessee Valley Authority Watts Bar Nuclear Plant 3R Lookout Place Tennessee Valley Authority 1101 Market Street P.O. Box 2000 Chattanooga, TN 37402-2801 Spring City, TN 37381-2000 Larry E. Nicholson Ashok S. Bhatnagar General Manager Senior Vice President Performance Improvement Nuclear Generation Development and Tennessee Valley Authority Construction 3R Lookout Place Tennessee Valley Authority 1101 Market Street 6A Lookout Place Chattanooga, TN 37402-2801 1101 Market Street Chattanooga, TN 37402-2801 Michael A. Purcell Senior Licensing Manager Masoud Bajestani Nuclear Power Group Vice President Watts Bar Unit 2 Tennessee Valley Authority Watts Bar Nuclear Plant 4K Lookout Place Tennessee Valley Authority 1101 Market Street P.O. Box 2000 Chattanooga, TN 37402-2801 Spring City, TN 37381 Michael K. Brandon Gordon P. Arent Manager New Generation Licensing Manager Licensing and Industry Affairs Watts Bar Nuclear Plant Watts Bar Nuclear Plant Tennessee Valley Authority Tennessee Valley Authority P.O. Box 2000 P.O. Box 2000 Spring City, TN 37381 Spring City, TN 37381 _________________________ x SUNSI REVIEW COMPLETE OFFICE RII:DRS RII:DRS RII:DRP RII:DRP RII:DRP SIGNATURE /RA/ /RA/ /RA/

NAME M. Ernstes J.Wallo E. Guthrie DATE 8/28/2009 8/28/2009 8/28/2009 E-MAIL COPY? YES NO YES NO YES NO YES NO YES NO YES NO YES NO