Line 27: Line 27:
==Subject:==
==Subject:==
Draft Safety Evaluation for Licensing Topical Report NEDE-33005P-A / NEDO-33005-A, TRACG Application for Emergency Core Cooling Systems / Loss-of-Coolant-Accident Analysis for BWR/2-6 Satisfaction of Limitation 10.7 (EPID: L-2017-TOP-0036)
Draft Safety Evaluation for Licensing Topical Report NEDE-33005P-A / NEDO-33005-A, TRACG Application for Emergency Core Cooling Systems / Loss-of-Coolant-Accident Analysis for BWR/2-6 Satisfaction of Limitation 10.7 (EPID: L-2017-TOP-0036)
In Reference 1, the NRC provided a draft Safety Evaluation (SE) of the subject submittal and requested that GE-Hitachi Nuclear Energy Americas LLC (GEH) identify any information that it considers proprietary and provide comments on factual errors or clarity concerns. The enclosures to this letter provide the GEH response to this request. Please note that Enclosure 1 contains proprietary information of the type that GEH maintains in confidence and withholds from public disclosure. The affidavit contained within Enclosure 3 identifies that the information contained in Enclosure 1 has been handled and classified as proprietary to GEH. GEH hereby requests that the information in Enclosure 1 be withheld from public disclosure in accordance with the provisions of 10 CFR 2.390 and 9.17. Enclosure 1 is the proprietary version of the Comment Summary Table and Markup of Draft Safety Evaluation. Enclosure 2 is a non-proprietary version. Enclosure 3 contains the affidavit. If you have questions regarding the enclosed response, please contact me or Guangjun Li at 910.819.1823. Sincerely, James F. Harrison Vice President, Fuel Licensing  
In Reference 1, the NRC provided a draft Safety Evaluation (SE) of the subject submittal and requested that GE-Hitachi Nuclear Energy Americas LLC (GEH) identify any information that it considers proprietary and provide comments on factual errors or clarity concerns. The enclosures to this letter provide the GEH response to this request. Please note that Enclosure 1 contains proprietary information of the type that GEH maintains in confidence and withholds from public disclosure. The affidavit contained within Enclosure 3 identifies that the information contained in Enclosure 1 has been handled and classified as proprietary to GEH. GEH hereby requests that the information in Enclosure 1 be withheld from public disclosure in accordance with the provisions of 10 CFR 2.390 and 9.17. Enclosure 1 is the proprietary version of the Comment Summary Table and Markup of Draft Safety Evaluation. Enclosure 2 is a non-proprietary version. Enclosure 3 contains the affidavit. If you have questions regarding the enclosed response, please contact me or Guangjun Li at 910.819.1823. Sincerely, James F. Harrison Vice President, Fuel Licensing  


Regulatory Affairs GE-Hitachi Nuclear Energy Americas LLC  
Regulatory Affairs GE-Hitachi Nuclear Energy Americas LLC  
Line 44: Line 44:
==Enclosures:==
==Enclosures:==
: 1. Comment Summary Table and Draft SE Markup - GEH Proprietary Information - Class II (Internal)  
: 1. Comment Summary Table and Draft SE Markup - GEH Proprietary Information - Class II (Internal)  
: 2. Comment Summary Table and Draft SE Markup - Non-Proprietary Information - Class I (Public)  
: 2. Comment Summary Table and Draft SE Markup - Non-Proprietary Information - Class I (Public) 3. Affidavit dated April 2018 cc: J Golla, US NRC JG Head, GEH/Wilmington R Harrington, GEH/Wilmington G Li, GEH/Wilmington  PLM Specification 001N8570 R12  
: 3. Affidavit dated April 2018 cc: J Golla, US NRC JG Head, GEH/Wilmington R Harrington, GEH/Wilmington G Li, GEH/Wilmington  PLM Specification 001N8570 R12  


Document Components: 001 M180090 Cover Letter.pdf 002 M180090 Enclosure 1 Proprietary.pdf 003 M180090 Enclosure 2 Non-Proprietary.pdf 004 M180090 Enclosure 3 Affidavit.pdf}}
Document Components: 001 M180090 Cover Letter.pdf 002 M180090 Enclosure 1 Proprietary.pdf 003 M180090 Enclosure 2 Non-Proprietary.pdf 004 M180090 Enclosure 3 Affidavit.pdf}}

Latest revision as of 00:01, 6 July 2018

Draft Safety Evaluation for Licensing Topical Report NEDE-33005P-A / NEDO-33005-A, Tracg Application for Emergency Core Cooling Systems / Loss-of-Coolant-Accident Analysis for BWR/2-6 Satisfaction of Limitation 10.7
ML18117A311
Person / Time
Site: PROJ0710, 99902024
Issue date: 04/27/2018
From: Harrison J F
GE Hitachi Nuclear Energy, GE-Hitachi Nuclear Energy Americas
To:
Document Control Desk, Office of New Reactors, Office of Nuclear Reactor Regulation
Shared Package
ML18117A310 List:
References
EPID L-2017-TOP-0036, M180090
Download: ML18117A311 (2)


Text

GE Hitachi Nuclear Energy James F. Harrison GE-Hitachi Nuclear Energy Americas LLC Vice President, Fuel Licensing, Regulatory Affairs P.O. Box 780, M/C A-75 Wilmington, NC 28401 USA

T 910.620.1826 james.harrison@ge.com

M180090 April 27, 2018 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555-0001

Subject:

Draft Safety Evaluation for Licensing Topical Report NEDE-33005P-A / NEDO-33005-A, TRACG Application for Emergency Core Cooling Systems / Loss-of-Coolant-Accident Analysis for BWR/2-6 Satisfaction of Limitation 10.7 (EPID: L-2017-TOP-0036)

In Reference 1, the NRC provided a draft Safety Evaluation (SE) of the subject submittal and requested that GE-Hitachi Nuclear Energy Americas LLC (GEH) identify any information that it considers proprietary and provide comments on factual errors or clarity concerns. The enclosures to this letter provide the GEH response to this request. Please note that Enclosure 1 contains proprietary information of the type that GEH maintains in confidence and withholds from public disclosure. The affidavit contained within Enclosure 3 identifies that the information contained in Enclosure 1 has been handled and classified as proprietary to GEH. GEH hereby requests that the information in Enclosure 1 be withheld from public disclosure in accordance with the provisions of 10 CFR 2.390 and 9.17. Enclosure 1 is the proprietary version of the Comment Summary Table and Markup of Draft Safety Evaluation. Enclosure 2 is a non-proprietary version. Enclosure 3 contains the affidavit. If you have questions regarding the enclosed response, please contact me or Guangjun Li at 910.819.1823. Sincerely, James F. Harrison Vice President, Fuel Licensing

Regulatory Affairs GE-Hitachi Nuclear Energy Americas LLC

Project No. 710

Docket No. 99902024 Proprietary Notice This letter transmits proprietary information in accordance with 10 CFR 2.390. Upon the removal of Enclosure 1, the balance of the letter may be considered non-proprietary.

M180090 Page 2 of 2

Reference:

1. Letter from Dennis C. Morey (NRC) to Jerald G. Head (GEH),

Subject:

Draft Safety Evaluation for Licensing Topical Report NEDE-33005P-A / NEDO 33005-A, TRACG Application for Emergency Core Cooling Systems / Loss of-Coolant-Accident Analysis for BWR/2-6 Satisfaction of Limitation 10.7 (E PID: L-2017-TOP-0036), April 10, 2018.

Enclosures:

1. Comment Summary Table and Draft SE Markup - GEH Proprietary Information - Class II (Internal)
2. Comment Summary Table and Draft SE Markup - Non-Proprietary Information - Class I (Public) 3. Affidavit dated April 2018 cc: J Golla, US NRC JG Head, GEH/Wilmington R Harrington, GEH/Wilmington G Li, GEH/Wilmington PLM Specification 001N8570 R12

Document Components: 001 M180090 Cover Letter.pdf 002 M180090 Enclosure 1 Proprietary.pdf 003 M180090 Enclosure 2 Non-Proprietary.pdf 004 M180090 Enclosure 3 Affidavit.pdf