ML14302A021: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:1NRR-PMDAPEm ResourceFrom:EDWARDS, MICHAEL L [medwards@oppd.com]Sent:Tuesday, October 28, 2014 4:49 PMTo:Lyon, Fred; HANSHER, BILL RCc:SIMPKIN, TERRENCE W; HOOKER, CHRISTOPHER T; MAASSEN, KRISTEN G
{{#Wiki_filter:1NRR-PMDAPEm Resource From:EDWARDS, MICHAEL L [medwards@oppd.com]
Sent:Tuesday, October 28, 2014 4:49 PM To:Lyon, Fred; HANSHER, BILL R Cc:SIMPKIN, TERRENCE W; HOOKER, CHRISTOPHER T; MAASSEN, KRISTEN G


==Subject:==
==Subject:==
RE: Error in RR-14 (TAC No. MF4643)Attachments:LIC-14-0109.pdfFred, This is in regard to the SE for RR-14. Our Engineers have verified that you are correct, the allowable flaw size is 10" in the circumferential direction and 4" in the axial direction. I've highlighted the sentence in the calculation we attached to our August 19, 2014 letter that shows this. See Page 8 of 12 in the Structural Integrity Associates Calculation.        Michael Edwards Nuclear Licensing Engineer Regulatory Assurance Department Omaha Public Power District 9610 Power Lane, Blair NE  68008 402-533-6929 medwards@oppd.com   From: Lyon, Fred [mailto:Fred.Lyon@nrc.gov] Sent: Tuesday, October 28, 2014 10:11 AM To: HANSHER, BILL R Cc: EDWARDS, MICHAEL L; SIMPKIN, TERRENCE W  
RE: Error in RR-14 (TAC No. MF4643)
Attachments:
LIC-14-0109.pdf Fred, This is in regard to the SE for RR-14. Our Engineers have verified that you are correct, the allowable flaw size is 10" in the circumferential direction and 4" in the axial direction. I've highlighted the sentence in the calculation we attached to our August 19, 2014 letter that shows this. See Page 8 of 12 in the Structural Integrity Associates Calculation.        Michael Edwards Nuclear Licensing Engineer Regulatory Assurance Department Omaha Public Power District 9610 Power Lane, Blair NE  68008 402-533-6929 medwards@oppd.com From: Lyon, Fred [mailto:Fred.Lyon@nrc.gov]
Sent: Tuesday, October 28, 2014 10:11 AM To: HANSHER, BILL R Cc: EDWARDS, MICHAEL L; SIMPKIN, TERRENCE W  


==Subject:==
==Subject:==
RE: Error in RR-14 (TAC No. MF4643) Importance: High  P.S. don't forget I also need:
RE: Error in RR-14 (TAC No. MF4643) Importance: High  P.S. don't forget I also need:  
: 1. feedback on 12/2 or 12/4 for the containment structures meeting 2. path forward on TAC No. MF2591 (equipment classification issue)
: 1. feedback on 12/2 or 12/4 for the containment structures meeting  
From: HANSHER, BILL R [mailto:bhansher@oppd.com] Sent: Tuesday, October 28, 2014 7:35 AM To: Lyon, Fred  
: 2. path forward on TAC No. MF2591 (equipment classification issue)  
 
From: HANSHER, BILL R  
[mailto:bhansher@oppd.com]
Sent: Tuesday, October 28, 2014 7:35 AM To: Lyon, Fred  


==Subject:==
==Subject:==
RE: Error in RR-14 (TAC No. MF4643) I forwarded to engineering. Mike and I have ERO drill today.
RE: Error in RR-14 (TAC No. MF4643)
From: Lyon, Fred [mailto:Fred.Lyon@nrc.gov]  Sent: Tuesday, October 28, 2014 5:29 AM To: HANSHER, BILL R; EDWARDS, MICHAEL L  
I forwarded to engineering. Mike and I have ERO drill today.  
 
From: Lyon, Fred [mailto:Fred.Lyon@nrc.gov
]  Sent: Tuesday, October 28, 2014 5:29 AM To: HANSHER, BILL R; EDWARDS, MICHAEL L  


==Subject:==
==Subject:==
Error in RR-14 (TAC No. MF4643) Importance: High 2The staff is preparing the final written SE for relief request RR-14, dated 8/15/14, and noticed an apparent discrepancy in the submittal.
Error in RR-14 (TAC No. MF4643) Importance: High 2The staff is preparing the final written SE for relief request RR-14, dated 8/15/14, and noticed an apparent discrepancy in the submittal.  
 
In the submittal, Attachment 1, page 3, 5th paragraph, the licensee stated that, "-The evaluation concluded, inpart, that the allowable through-wall flaw sizes are greater than 10" in the axial and 4" in the circumferential direction-"  There appears to be a discrepancy on the allowable flaw sizes in the previous sentence.   
In the submittal, Attachment 1, page 3, 5th paragraph, the licensee stated that, "-The evaluation concluded, inpart, that the allowable through-wall flaw sizes are greater than 10" in the axial and 4" in the circumferential direction-"  There appears to be a discrepancy on the allowable flaw sizes in the previous sentence.   


Page 4 of Attachment 2 to the submittal, last paragraph, indicates allowable flaw sizes are 10" in the circumferential direction and 4" in the axial direction. Also, in the 8/19/14 supplement, the licensee's vendor reported that the allowable flaw size should be 10" in the circumferential direction and 4" in the axial direction.
Page 4 of Attachment 2 to the submittal, last paragraph, indicates allowable flaw sizes are 10" in the circumferential direction and 4" in the axial direction. Also, in the 8/19/14 supplement, the licensee's vendor reported that the allowable flaw size should be 10" in the circumferential direction and 4" in the axial direction.
We think the allowable flaw size should be 10" in the circumferential direction and 4" in the axial direction.
 
Please confirm the discrepancy on page 3 in Attachment 1 of the 8/15/14 submittal, or let me know otherwise. An email is sufficient; I don't think I need a supplemental letter.
We think the allowable flaw size should be 10" in the circumferential direction and 4" in the axial direction.  
 
Please confirm the discrepancy on page 3 in Attachment 1 of the 8/15/14 submittal, or let me know otherwise. An email is sufficient; I don't think I need a supplemental letter.  
 
Thanks, Fred  This e-mail contains Omaha Public Power District's confidential and proprietary information and is for use only by the intended recipient. Unless explicitly stated otherwise, this e-mail is not a contract offer, amendment, or acceptance. If you are not the intended recipient you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited.
Thanks, Fred  This e-mail contains Omaha Public Power District's confidential and proprietary information and is for use only by the intended recipient. Unless explicitly stated otherwise, this e-mail is not a contract offer, amendment, or acceptance. If you are not the intended recipient you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited.
Hearing Identifier:  NRR_PMDA Email Number:  1666  Mail Envelope Properties  (D9B37C2F1C3EA14784A17E929D6E4771AC3D1F46)  
Hearing Identifier:  NRR_PMDA Email Number:  1666  Mail Envelope Properties  (D9B37C2F1C3EA14784A17E929D6E4771AC3D1F46)


==Subject:==
==Subject:==
RE: Error in RR-14 (TAC No. MF4643)  Sent Date:  10/28/2014 4:48:42 PM  Received Date:  10/28/2014 4:48:54 PM From:    EDWARDS, MICHAEL L Created By:  medwards@oppd.com Recipients:    "SIMPKIN, TERRENCE W" <twsimpkin@oppd.com>
RE: Error in RR-14 (TAC No. MF4643)  Sent Date:  10/28/2014 4:48:42 PM  Received Date:  10/28/2014 4:48:54 PM From:    EDWARDS, MICHAEL L Created By:  medwards@oppd.com Recipients:    "SIMPKIN, TERRENCE W" <twsimpkin@oppd.com>
Tracking Status: None  "HOOKER, CHRISTOPHER T" <chooker@oppd.com>  Tracking Status: None  "MAASSEN, KRISTEN G" <kmaassen@oppd.com>  Tracking Status: None "Lyon, Fred" <Fred.Lyon@nrc.gov>  Tracking Status: None  "HANSHER, BILL R" <bhansher@oppd.com>
Tracking Status: None  "HOOKER, CHRISTOPHER T" <chooker@oppd.com>  Tracking Status: None  "MAASSEN, KRISTEN G" <kmaassen@oppd.com>  Tracking Status: None "Lyon, Fred" <Fred.Lyon@nrc.gov>  Tracking Status: None  "HANSHER, BILL R" <bhansher@oppd.com>
Tracking Status: None Post Office:  SECEX03.oppd.oppd-ds.com Files    Size      Date & Time MESSAGE    3077      10/28/2014 4:48:54 PM  LIC-14-0109.pdf    1950504   Options  Priority:    Standard  Return Notification:    No  Reply Requested:    No  Sensitivity:    Normal  Expiration Date:      Recipients Received:}}
Tracking Status: None Post Office:  SECEX03.oppd.oppd-ds.com
 
Files    Size      Date & Time MESSAGE    3077      10/28/2014 4:48:54 PM  LIC-14-0109.pdf    1950504 Options  Priority:    Standard  Return Notification:    No  Reply Requested:    No  Sensitivity:    Normal  Expiration Date:      Recipients Received:}}

Revision as of 09:27, 1 July 2018

2014/10/28 NRR E-mail Capture - Error in RR-14 (TAC No. MF4643)
ML14302A021
Person / Time
Site: Fort Calhoun Omaha Public Power District icon.png
Issue date: 10/28/2014
From: Edwards M L
Omaha Public Power District
To: Lyon F E
Division of Operating Reactor Licensing
References
MF4643
Download: ML14302A021 (28)


Text

1NRR-PMDAPEm Resource From:EDWARDS, MICHAEL L [medwards@oppd.com]

Sent:Tuesday, October 28, 2014 4:49 PM To:Lyon, Fred; HANSHER, BILL R Cc:SIMPKIN, TERRENCE W; HOOKER, CHRISTOPHER T; MAASSEN, KRISTEN G

Subject:

RE: Error in RR-14 (TAC No. MF4643)

Attachments:

LIC-14-0109.pdf Fred, This is in regard to the SE for RR-14. Our Engineers have verified that you are correct, the allowable flaw size is 10" in the circumferential direction and 4" in the axial direction. I've highlighted the sentence in the calculation we attached to our August 19, 2014 letter that shows this. See Page 8 of 12 in the Structural Integrity Associates Calculation. Michael Edwards Nuclear Licensing Engineer Regulatory Assurance Department Omaha Public Power District 9610 Power Lane, Blair NE 68008 402-533-6929 medwards@oppd.com From: Lyon, Fred [1]

Sent: Tuesday, October 28, 2014 10:11 AM To: HANSHER, BILL R Cc: EDWARDS, MICHAEL L; SIMPKIN, TERRENCE W

Subject:

RE: Error in RR-14 (TAC No. MF4643) Importance: High P.S. don't forget I also need:

1. feedback on 12/2 or 12/4 for the containment structures meeting
2. path forward on TAC No. MF2591 (equipment classification issue)

From: HANSHER, BILL R

[2]

Sent: Tuesday, October 28, 2014 7:35 AM To: Lyon, Fred

Subject:

RE: Error in RR-14 (TAC No. MF4643)

I forwarded to engineering. Mike and I have ERO drill today.

From: Lyon, Fred [mailto:Fred.Lyon@nrc.gov

] Sent: Tuesday, October 28, 2014 5:29 AM To: HANSHER, BILL R; EDWARDS, MICHAEL L

Subject:

Error in RR-14 (TAC No. MF4643) Importance: High 2The staff is preparing the final written SE for relief request RR-14, dated 8/15/14, and noticed an apparent discrepancy in the submittal.

In the submittal, Attachment 1, page 3, 5th paragraph, the licensee stated that, "-The evaluation concluded, inpart, that the allowable through-wall flaw sizes are greater than 10" in the axial and 4" in the circumferential direction-" There appears to be a discrepancy on the allowable flaw sizes in the previous sentence.

Page 4 of Attachment 2 to the submittal, last paragraph, indicates allowable flaw sizes are 10" in the circumferential direction and 4" in the axial direction. Also, in the 8/19/14 supplement, the licensee's vendor reported that the allowable flaw size should be 10" in the circumferential direction and 4" in the axial direction.

We think the allowable flaw size should be 10" in the circumferential direction and 4" in the axial direction.

Please confirm the discrepancy on page 3 in Attachment 1 of the 8/15/14 submittal, or let me know otherwise. An email is sufficient; I don't think I need a supplemental letter.

Thanks, Fred This e-mail contains Omaha Public Power District's confidential and proprietary information and is for use only by the intended recipient. Unless explicitly stated otherwise, this e-mail is not a contract offer, amendment, or acceptance. If you are not the intended recipient you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited.

Hearing Identifier: NRR_PMDA Email Number: 1666 Mail Envelope Properties (D9B37C2F1C3EA14784A17E929D6E4771AC3D1F46)

Subject:

RE: Error in RR-14 (TAC No. MF4643) Sent Date: 10/28/2014 4:48:42 PM Received Date: 10/28/2014 4:48:54 PM From: EDWARDS, MICHAEL L Created By: medwards@oppd.com Recipients: "SIMPKIN, TERRENCE W" <twsimpkin@oppd.com>

Tracking Status: None "HOOKER, CHRISTOPHER T" <chooker@oppd.com> Tracking Status: None "MAASSEN, KRISTEN G" <kmaassen@oppd.com> Tracking Status: None "Lyon, Fred" <Fred.Lyon@nrc.gov> Tracking Status: None "HANSHER, BILL R" <bhansher@oppd.com>

Tracking Status: None Post Office: SECEX03.oppd.oppd-ds.com

Files Size Date & Time MESSAGE 3077 10/28/2014 4:48:54 PM LIC-14-0109.pdf 1950504 Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date: Recipients Received: