NRR E-mail Capture - (External_Sender) Question Rvi Inspection Results
ML16131A731
Person / Time
Site: Fort Calhoun 
Issue date: 05/10/2016
From: Matzke E
Omaha Public Power District
To: Lyon F
Plant Licensing Branch IV
References
MF3412
Download: ML16131A731 (3)


Text

1 NRR-PMDAPEm Resource From:

MATZKE, ERICK P <ematzke@oppd.com>

Sent:

Tuesday, May 10, 2016 10:38 AM To:

Lyon, Fred Cc:

JACOBSEN, KRISTEN G; WASZAK, CAROL L; BLOME, BRADLEY H

Subject:

[External_Sender] RE: Question re: RVI inspection results (CAC No. MF3412)

Does this get it all??

ML15103A642 says:

ICls are replaced within a 9 year interval (22 are scheduled for replacement in RFO 27 beginning in April 2015, and 6 are scheduled for replacement in RFO 28).

How many ICI replacements were actually done in RFO 27?

We replaced 22 ICIs in FCR27. The next scheduled replacement of ICIs is all 28 in FCR30.

Also, please provide (by email to me) inspection results of the vessel internals for RFO 27.

Regarding inspections of reactor vessel flow skirt (Condition Report --CR2015-110119/16/2015), please confirm whether it will be incorporated as part of ASME Code,Section XI or MRP-227-A inspections during the period of extended operation. Will the skirt be inspected during RFO 28?

Reactor vessel internals inspections are scheduled for FCR28 and FCR29, no inspections occurred in FCR27. MRP-227 inspections and thermal shield are scheduled for FCR28. The only inspection that will occur in FCR29 is the UT of the baffle bolts.

The reactor vessel flow skirt is included in the ASME Code Section XI 10 year inspection that is scheduled for FCR28.

Erick Matzke Senior Nuclear Licensing Engineer Omaha Public Power District Fort Calhoun Station, Mail Stop: FC-2-4 9610 Power Lane, Blair NE 68008 402-533-6855 ematzke@oppd.com From: Lyon, Fred [1]

Sent: Tuesday, May 10, 2016 6:37 AM To: MATZKE, ERICK P

Subject:

Question re: RVI inspection results (CAC No. MF3412)

ML15103A642 says:

2 ICls are replaced within a 9 year interval (22 are scheduled for replacement in RFO 27 beginning in April 2015, and 6 are scheduled for replacement in RFO 28).

How many ICI replacements were actually done in RFO 27?

Also, please provide (by email to me) inspection results of the vessel internals for RFO 27.

Thanks, Fred This e-mail contains Omaha Public Power District's confidential and proprietary information and is for use only by the intended recipient. Unless explicitly stated otherwise, this e-mail is not a contract offer, amendment, or acceptance. If you are not the intended recipient you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited.

Hearing Identifier:

NRR_PMDA Email Number:

2832 Mail Envelope Properties (A238D6A5C1FF1A4393618100BC03701FCF020A1D)

Subject:

[External_Sender] RE: Question re: RVI inspection results (CAC No. MF3412)

Sent Date:

5/10/2016 10:38:19 AM Received Date:

5/10/2016 10:38:23 AM From:

MATZKE, ERICK P Created By:

ematzke@oppd.com Recipients:

"JACOBSEN, KRISTEN G" <kjacobsen@oppd.com>

Tracking Status: None "WASZAK, CAROL L" <clwaszak@oppd.com>

Tracking Status: None "BLOME, BRADLEY H" <bblome@oppd.com>

Tracking Status: None "Lyon, Fred" <Fred.Lyon@nrc.gov>

Tracking Status: None Post Office:

SEPEX731.oppd.oppd-ds.com Files Size Date & Time MESSAGE 2281 5/10/2016 10:38:23 AM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

1 NRR-PMDAPEm Resource From:

MATZKE, ERICK P <ematzke@oppd.com>

Sent:

Tuesday, May 10, 2016 10:38 AM To:

Lyon, Fred Cc:

JACOBSEN, KRISTEN G; WASZAK, CAROL L; BLOME, BRADLEY H

Subject:

[External_Sender] RE: Question re: RVI inspection results (CAC No. MF3412)

Does this get it all??

ML15103A642 says:

ICls are replaced within a 9 year interval (22 are scheduled for replacement in RFO 27 beginning in April 2015, and 6 are scheduled for replacement in RFO 28).

How many ICI replacements were actually done in RFO 27?

We replaced 22 ICIs in FCR27. The next scheduled replacement of ICIs is all 28 in FCR30.

Also, please provide (by email to me) inspection results of the vessel internals for RFO 27.

Regarding inspections of reactor vessel flow skirt (Condition Report --CR2015-110119/16/2015), please confirm whether it will be incorporated as part of ASME Code,Section XI or MRP-227-A inspections during the period of extended operation. Will the skirt be inspected during RFO 28?

Reactor vessel internals inspections are scheduled for FCR28 and FCR29, no inspections occurred in FCR27. MRP-227 inspections and thermal shield are scheduled for FCR28. The only inspection that will occur in FCR29 is the UT of the baffle bolts.

The reactor vessel flow skirt is included in the ASME Code Section XI 10 year inspection that is scheduled for FCR28.

Erick Matzke Senior Nuclear Licensing Engineer Omaha Public Power District Fort Calhoun Station, Mail Stop: FC-2-4 9610 Power Lane, Blair NE 68008 402-533-6855 ematzke@oppd.com From: Lyon, Fred [2]

Sent: Tuesday, May 10, 2016 6:37 AM To: MATZKE, ERICK P

Subject:

Question re: RVI inspection results (CAC No. MF3412)

ML15103A642 says:

2 ICls are replaced within a 9 year interval (22 are scheduled for replacement in RFO 27 beginning in April 2015, and 6 are scheduled for replacement in RFO 28).

How many ICI replacements were actually done in RFO 27?

Also, please provide (by email to me) inspection results of the vessel internals for RFO 27.

Thanks, Fred This e-mail contains Omaha Public Power District's confidential and proprietary information and is for use only by the intended recipient. Unless explicitly stated otherwise, this e-mail is not a contract offer, amendment, or acceptance. If you are not the intended recipient you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited.

Hearing Identifier:

NRR_PMDA Email Number:

2832 Mail Envelope Properties (A238D6A5C1FF1A4393618100BC03701FCF020A1D)

Subject:

[External_Sender] RE: Question re: RVI inspection results (CAC No. MF3412)

Sent Date:

5/10/2016 10:38:19 AM Received Date:

5/10/2016 10:38:23 AM From:

MATZKE, ERICK P Created By:

ematzke@oppd.com Recipients:

"JACOBSEN, KRISTEN G" <kjacobsen@oppd.com>

Tracking Status: None "WASZAK, CAROL L" <clwaszak@oppd.com>

Tracking Status: None "BLOME, BRADLEY H" <bblome@oppd.com>

Tracking Status: None "Lyon, Fred" <Fred.Lyon@nrc.gov>

Tracking Status: None Post Office:

SEPEX731.oppd.oppd-ds.com Files Size Date & Time MESSAGE 2281 5/10/2016 10:38:23 AM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: