| description = The following violation of very low significance (Green) was identified by the licensee and is a violation of NRC requirements, which meets the criteria of Section 2.3 of the NRC Enforcement Policy for being dispositioned as an NCV. The licensee violated TS Section 3.3.9, Boron Dilution Protection System, when they failed to enter the LCO Conditions A and C, which required 1-hour actions to close non-borated water source isolation valves and to verify that shutdown margins were within their limits. Unit 1 entered LCO 3.0.3 due to not completing the required actions. Upon discovery, the licensee lowered the water volume in the volume control tank to clear the alarms and exit all the LCOs. This violation was not greater than green since the shutdown margin was verified within 1 hour and no significant change in reactivity occurred. The licensee entered this issue into the CAP as AR01101873 and has submitted LER 2010-002-00.
| description = The following violation of very low significance (Green) was identified by the licensee and is a violation of NRC requirements, which meets the criteria of Section 2.3 of the NRC Enforcement Policy for being dispositioned as an NCV. The licensee violated TS Section 3.3.9, Boron Dilution Protection System, when they failed to enter the LCO Conditions A and C, which required 1-hour actions to close non-borated water source isolation valves and to verify that shutdown margins were within their limits. Unit 1 entered LCO 3.0.3 due to not completing the required actions. Upon discovery, the licensee lowered the water volume in the volume control tank to clear the alarms and exit all the LCOs. This violation was not greater than green since the shutdown margin was verified within 1 hour and no significant change in reactivity occurred. The licensee entered this issue into the CAP as AR01101873 and has submitted LER 2010-002-00.
}}
}}

Latest revision as of 11:41, 30 May 2018

05
Site: Braidwood Constellation icon.png
Report IR 05000456/2010010 Section 4OA7
Date counted Sep 30, 2010 (2010Q3)
Type: NCV: Green
cornerstone Mitigating Systems
Identified by: Licensee-identified
Inspection Procedure:
Inspectors (proximate) G Shear
J Jandovitz
M Thorpe Kavanaugh
N Feliz Adomo
T Go
INPO aspect
'