ML071500010: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
(4 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML071500010
| number = ML071500010
| issue date = 06/07/2007
| issue date = 06/07/2007
| title = Sequoyah Nuclear Plant, Units 1 and 2 and Watts Bar Nuclear Plant, Unit 1- NRC Generic Letter 2006-01: Steam Generator Tube Integrity and Associated Technical Specifications (TAC Nos. MD0110, MD0111 and MD0121)
| title = NRC Generic Letter 2006-01: Steam Generator Tube Integrity and Associated Technical Specifications
| author name = Moroney B T
| author name = Moroney B
| author affiliation = NRC/NRR/ADRO/DORL/LPLII-2
| author affiliation = NRC/NRR/ADRO/DORL/LPLII-2
| addressee name = Campbell W R
| addressee name = Campbell W
| addressee affiliation = Tennessee Valley Authority
| addressee affiliation = Tennessee Valley Authority
| docket = 05000327, 05000328, 05000390
| docket = 05000327, 05000328, 05000390
| license number = DPR-077, DPR-079, NPF-090
| license number = DPR-077, DPR-079, NPF-090
| contact person = Moroney B T, NRR/DORL, 415-3974
| contact person = Moroney B, NRR/DORL, 415-3974
| case reference number = TAC MD0110, TAC MD0111, TAC MD0121
| case reference number = TAC MD0110, TAC MD0111, TAC MD0121
| document type = Letter
| document type = Letter
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:June 7, 2007Mr. William R. Campbell, Jr.Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801
{{#Wiki_filter:June 7, 2007 Mr. William R. Campbell, Jr.
Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801


==SUBJECT:==
==SUBJECT:==
SEQUOYAH NUCLEAR PLANT, UNITS 1 AND 2 AND WATTS BAR NUCLEARPLANT, UNIT 1 - NRC GENERIC LETTER 2006-01: STEAM GENERATOR TUBE INTEGRITY AND ASSOCIATED TECHNICAL SPECIFICATIONS (TAC NOS. MD0110, MD0111 AND MD0121)On January 20, 2006, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter(GL) 2006-01, "Steam Generator [SG] Tube Integrity and Associated Technical Specifications
SEQUOYAH NUCLEAR PLANT, UNITS 1 AND 2 AND WATTS BAR NUCLEAR PLANT, UNIT 1 - NRC GENERIC LETTER 2006-01: STEAM GENERATOR TUBE INTEGRITY AND ASSOCIATED TECHNICAL SPECIFICATIONS (TAC NOS. MD0110, MD0111 AND MD0121)
[TSs]," (Agencywide Document Access and Management System (ADAMS) Accession No. ML060200385). This GL requested that addressees either submit a description of their program for ensuring SG tube integrity for the interval between inspections or adopt alternative TS requirements for ensuring SG tube integrity. By letter dated February 21, 2006 (ADAMS Accession No. ML060540116), Tennessee ValleyAuthority (TVA), the licensee for Sequoyah Nuclear Plant (SQN), Units 1 and 2, and the Watts Bar Nuclear Plant (WBN) Unit 1, submitted a response to GL 2006-01. The response stated that applications for changes to the TSs for SQN Units 1 and 2 and WBN Unit 1 to adopt the alternative TS requirements for ensuring SG tube integrity had previously been submitted.
On January 20, 2006, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2006-01, Steam Generator [SG] Tube Integrity and Associated Technical Specifications
These new TSs were modeled after Technical Specification Task Force (TSTF) Traveler, TSTF-449, "Steam Generator Tube Integrity," (ADAMS Accession No. ML051090200). The application for SQN Unit 1 to adopt the alternative TS requirements for ensuring SG tubeintegrity was dated August 31, 2005 (ADAMS Accession No. ML052500560). On February 23, 2006, the NRC staff issued Amendment No. 306 to the SQN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML060550100).The application for SQN Unit 2 to adopt the alternative TS requirements for ensuring SG tubeintegrity was dated February 15, 2006 (ADAMS Accession No. ML060600405). The original application was supplemented by letters dated August 7, 2006 (ADAMS Accession No. ML062280054), August 30, 2006 (ADAMS Accession No. ML062500211), November 30, 2006 (ADAMS Accession No. ML063390665), and April 2, 2007 (ADAMS Accession No. ML071010153). On May 22, 2007, the NRC staff issued Amendment No. 305 to the SQN Unit 2 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML071210013).
[TSs], (Agencywide Document Access and Management System (ADAMS) Accession No. ML060200385). This GL requested that addressees either submit a description of their program for ensuring SG tube integrity for the interval between inspections or adopt alternative TS requirements for ensuring SG tube integrity.
W. R. Campbell, Jr.-2-The application for WBN Unit 1 to adopt the alternative TS requirements for ensuring SG tubeintegrity was dated December 15, 2005 (ADAMS Accession No. ML053540067). The original application was supplemented by letters dated June 12, 2006 (ADAMS Accession No.
By letter dated February 21, 2006 (ADAMS Accession No. ML060540116), Tennessee Valley Authority (TVA), the licensee for Sequoyah Nuclear Plant (SQN), Units 1 and 2, and the Watts Bar Nuclear Plant (WBN) Unit 1, submitted a response to GL 2006-01. The response stated that applications for changes to the TSs for SQN Units 1 and 2 and WBN Unit 1 to adopt the alternative TS requirements for ensuring SG tube integrity had previously been submitted.
ML061650267) and September 8, 2006 (ADAMS Accession No. ML062550371). On November 3, 2006, the NRC staff issued Amendment No. 65 to the WBN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML062910090).The NRC staff finds the licensee's adoption of new SG TSs modeled after TSTF-449 to be anacceptable and complete response to GL 2006-01. This completes the NRC staff's efforts on TAC Nos. MD0110, MD0111 and MD0121. If you have any questions regarding this letter, please contact me at 301-415-3974.Sincerely, /RA/Brendan T. Moroney, Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket Nos. 50-327, 50-328 and 50-390 cc:  See next page
These new TSs were modeled after Technical Specification Task Force (TSTF) Traveler, TSTF-449, Steam Generator Tube Integrity, (ADAMS Accession No. ML051090200).
The application for SQN Unit 1 to adopt the alternative TS requirements for ensuring SG tube integrity was dated August 31, 2005 (ADAMS Accession No. ML052500560). On February 23, 2006, the NRC staff issued Amendment No. 306 to the SQN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML060550100).
The application for SQN Unit 2 to adopt the alternative TS requirements for ensuring SG tube integrity was dated February 15, 2006 (ADAMS Accession No. ML060600405). The original application was supplemented by letters dated August 7, 2006 (ADAMS Accession No. ML062280054), August 30, 2006 (ADAMS Accession No. ML062500211), November 30, 2006 (ADAMS Accession No. ML063390665), and April 2, 2007 (ADAMS Accession No. ML071010153). On May 22, 2007, the NRC staff issued Amendment No. 305 to the SQN Unit 2 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML071210013).


ML053540067). The original application was supplemented by letters dated June 12, 2006 (ADAMS Accession No.
W. R. Campbell, Jr.                            The application for WBN Unit 1 to adopt the alternative TS requirements for ensuring SG tube integrity was dated December 15, 2005 (ADAMS Accession No. ML053540067). The original application was supplemented by letters dated June 12, 2006 (ADAMS Accession No. ML061650267) and September 8, 2006 (ADAMS Accession No. ML062550371). On November 3, 2006, the NRC staff issued Amendment No. 65 to the WBN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML062910090).
ML061650267) and September 8, 2006 (ADAMS Accession No. ML062550371). On November 3, 2006, the NRC staff issued Amendment No. 65 to the WBN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML062910090).The NRC staff finds the licensee's adoption of new SG TSs modeled after TSTF-449 to be anacceptable and complete response to GL 2006-01. This completes the NRC staff's efforts on TAC Nos. MD0110, MD0111 and MD0121. If you have any questions regarding this letter, please contact me at 301-415-3974.Sincerely, /RA/Brendan T. Moroney, Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor RegulationDocket Nos. 50-327, 50-328 and 50-390 cc: See next pageDISTRIBUTION
The NRC staff finds the licensees adoption of new SG TSs modeled after TSTF-449 to be an acceptable and complete response to GL 2006-01. This completes the NRC staffs efforts on TAC Nos. MD0110, MD0111 and MD0121. If you have any questions regarding this letter, please contact me at 301-415-3974.
:PUBLICLPLII-2 r/fRidsNrrDorlLpl2-2RidsNrrPMBMoroney RidsNrrLACSolaRidsOgcRpRidsAcrsAcnwMailCenterRidsNrrDirsltsb RidsRgn2MailCenter KKarwoski, NRRRidsNrrDorlDprRidsNrrCsgbDBeaulieu, NRRADAMS ACCESSION NO: ML071500010OFFICELPL2-2/PMLPL2-2/LANRR/CSGB/BCLPL2-2/BCNAMEBMoroneyRSolaAHiserTBoyceDATE6/7/076/7/076 /06/07 6/7/07 Page 1 of 2William R. Campbell, Jr.SEQUOYAH NUCLEAR PLANT   Tennessee Valley Authority WATTS BAR NUCLEAR PLANT cc:Mr. Ashok S. Bhatnagar Senior Vice President Nuclear Generation Development and Construction Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801   Mr. Preston D. Swafford Senior Vice President Nuclear Support Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801 Mr. Walter M. Justice II Interim Vice President Nuclear Engineering & Technical Services Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801Mr. Michael D. Skaggs, Site Vice PresidentWatts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN  37381Mr. Randy Douet, Site Vice PresidentSequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000General CounselTennessee Valley Authority ET 11A 400 West Summit Hill Drive Knoxville, TN  37902Mr. John C. Fornicola, ManagerNuclear Assurance Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801Mr. Robert H. Bryan, Jr., General ManagerLicensing and Industry Affairs Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN  37402-2801 Ms. Beth A. Wetzel, Manager Corporate Nuclear Licensing and Industry Affairs Tennessee Valley Authority 4X Blue Ridge 1101 Market Street Chattanooga, TN  37402-2801Mr. Glenn W. Morris, ManagerLicensing and Industry Affairs Sequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000Mr. David A. Kulisek, Plant ManagerSequoyah Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Soddy Daisy, TN 37384-2000Senior Resident InspectorSequoyah Nuclear Plant U.S. Nuclear Regulatory Commission 2600 Igou Ferry Road Soddy Daisy, TN 37379County MayorHamilton County Courthouse Chattanooga, TN 37402-2801 Page 2 of 2William R. Campbell, Jr.SEQUOYAH NUCLEAR PLANT   Tennessee Valley Authority WATTS BAR NUCLEAR PLANT cc:Mr. James D. Smith, Acting ManagerLicensing and Industry Affairs Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381Mr. Michael J. Lorek, Plant ManagerWatts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381Senior Resident InspectorWatts Bar Nuclear Plant U.S. Nuclear Regulatory Commission 1260 Nuclear Plant Road Spring City, TN 37381 County Executive 375 Church Street Suite 215 Dayton, TN 37321County Mayor P. O. Box 156 Decatur, TN 37322Mr. Lawrence E. Nanney, DirectorDivision of Radiological Health Dept. of Environment & Conservation Third Floor, L and C Annex 401 Church Street Nashville, TN 37243-1532Ms. Ann P. Harris341 Swing Loop Road Rockwood, TN 37854}}
Sincerely,
                                            /RA/
Brendan T. Moroney, Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-327, 50-328 and 50-390 cc: See next page
 
ML053540067). The original application was supplemented by letters dated June 12, 2006 (ADAMS Accession No. ML061650267) and September 8, 2006 (ADAMS Accession No. ML062550371). On November 3, 2006, the NRC staff issued Amendment No. 65 to the WBN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML062910090).
The NRC staff finds the licensees adoption of new SG TSs modeled after TSTF-449 to be an acceptable and complete response to GL 2006-01. This completes the NRC staffs efforts on TAC Nos. MD0110, MD0111 and MD0121. If you have any questions regarding this letter, please contact me at 301-415-3974.
Sincerely,
                                            /RA/
Brendan T. Moroney, Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-327, 50-328 and 50-390 cc: See next page DISTRIBUTION:
PUBLIC                LPLII-2 r/f        RidsNrrDorlLpl2-2          RidsNrrPMBMoroney RidsNrrLACSola        RidsOgcRp          RidsAcrsAcnwMailCenter      RidsNrrDirsltsb RidsRgn2MailCenter     RidsNrrDorlDpr    RidsNrrCsgb                DBeaulieu, NRR KKarwoski, NRR ADAMS ACCESSION NO: ML071500010 OFFICE LPL2-2/PM              LPL2-2/LA            NRR/CSGB/BC          LPL2-2/BC NAME BMoroney                  RSola                AHiser              TBoyce DATE      6/7/07              6/7/07                6 /06/07             6/7/07 Page 1 of 2 William R. Campbell, Jr.                   SEQUOYAH NUCLEAR PLANT Tennessee Valley Authority                 WATTS BAR NUCLEAR PLANT cc:
Mr. Ashok S. Bhatnagar                     Mr. John C. Fornicola, Manager Senior Vice President                     Nuclear Assurance Nuclear Generation Development             Tennessee Valley Authority and Construction                         6A Lookout Place Tennessee Valley Authority                 1101 Market Street 6A Lookout Place                           Chattanooga, TN 37402-2801 1101 Market Street Chattanooga, TN 37402-2801                 Mr. Robert H. Bryan, Jr., General Manager Licensing and Industry Affairs Mr. Preston D. Swafford                   Tennessee Valley Authority Senior Vice President                     4X Blue Ridge Nuclear Support                           1101 Market Street Tennessee Valley Authority                 Chattanooga, TN 37402-2801 6A Lookout Place 1101 Market Street                         Ms. Beth A. Wetzel, Manager Chattanooga, TN 37402-2801                 Corporate Nuclear Licensing and Industry Affairs Mr. Walter M. Justice II                   Tennessee Valley Authority Interim Vice President                     4X Blue Ridge Nuclear Engineering & Technical Services   1101 Market Street Tennessee Valley Authority                 Chattanooga, TN 37402-2801 6A Lookout Place 1101 Market Street                         Mr. Glenn W. Morris, Manager Chattanooga, TN 37402-2801                Licensing and Industry Affairs Sequoyah Nuclear Plant Mr. Michael D. Skaggs, Site Vice President Tennessee Valley Authority Watts Bar Nuclear Plant                   P.O. Box 2000 Tennessee Valley Authority                 Soddy Daisy, TN 37384-2000 P.O. Box 2000 Spring City, TN 37381                      Mr. David A. Kulisek, Plant Manager Sequoyah Nuclear Plant Mr. Randy Douet, Site Vice President      Tennessee Valley Authority Sequoyah Nuclear Plant                     P.O. Box 2000 Tennessee Valley Authority                Soddy Daisy, TN 37384-2000 P.O. Box 2000 Soddy Daisy, TN 37384-2000                Senior Resident Inspector Sequoyah Nuclear Plant General Counsel                            U.S. Nuclear Regulatory Commission Tennessee Valley Authority                2600 Igou Ferry Road ET 11A                                    Soddy Daisy, TN 37379 400 West Summit Hill Drive Knoxville, TN 37902                        County Mayor Hamilton County Courthouse Chattanooga, TN 37402-2801
 
Page 2 of 2 William R. Campbell, Jr.           SEQUOYAH NUCLEAR PLANT Tennessee Valley Authority         WATTS BAR NUCLEAR PLANT cc:
Mr. James D. Smith, Acting Manager Licensing and Industry Affairs Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381 Mr. Michael J. Lorek, Plant Manager Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381 Senior Resident Inspector Watts Bar Nuclear Plant U.S. Nuclear Regulatory Commission 1260 Nuclear Plant Road Spring City, TN 37381 County Executive 375 Church Street Suite 215 Dayton, TN 37321 County Mayor P. O. Box 156 Decatur, TN 37322 Mr. Lawrence E. Nanney, Director Division of Radiological Health Dept. of Environment & Conservation Third Floor, L and C Annex 401 Church Street Nashville, TN 37243-1532 Ms. Ann P. Harris 341 Swing Loop Road Rockwood, TN 37854}}

Latest revision as of 19:35, 22 March 2020

NRC Generic Letter 2006-01: Steam Generator Tube Integrity and Associated Technical Specifications
ML071500010
Person / Time
Site: Watts Bar, Sequoyah  Tennessee Valley Authority icon.png
Issue date: 06/07/2007
From: Moroney B
NRC/NRR/ADRO/DORL/LPLII-2
To: Campbell W
Tennessee Valley Authority
Moroney B, NRR/DORL, 415-3974
References
TAC MD0110, TAC MD0111, TAC MD0121
Download: ML071500010 (5)


Text

June 7, 2007 Mr. William R. Campbell, Jr.

Chief Nuclear Officer and Executive Vice President Tennessee Valley Authority 6A Lookout Place 1101 Market Street Chattanooga, TN 37402-2801

SUBJECT:

SEQUOYAH NUCLEAR PLANT, UNITS 1 AND 2 AND WATTS BAR NUCLEAR PLANT, UNIT 1 - NRC GENERIC LETTER 2006-01: STEAM GENERATOR TUBE INTEGRITY AND ASSOCIATED TECHNICAL SPECIFICATIONS (TAC NOS. MD0110, MD0111 AND MD0121)

On January 20, 2006, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2006-01, Steam Generator [SG] Tube Integrity and Associated Technical Specifications

[TSs], (Agencywide Document Access and Management System (ADAMS) Accession No. ML060200385). This GL requested that addressees either submit a description of their program for ensuring SG tube integrity for the interval between inspections or adopt alternative TS requirements for ensuring SG tube integrity.

By letter dated February 21, 2006 (ADAMS Accession No. ML060540116), Tennessee Valley Authority (TVA), the licensee for Sequoyah Nuclear Plant (SQN), Units 1 and 2, and the Watts Bar Nuclear Plant (WBN) Unit 1, submitted a response to GL 2006-01. The response stated that applications for changes to the TSs for SQN Units 1 and 2 and WBN Unit 1 to adopt the alternative TS requirements for ensuring SG tube integrity had previously been submitted.

These new TSs were modeled after Technical Specification Task Force (TSTF) Traveler, TSTF-449, Steam Generator Tube Integrity, (ADAMS Accession No. ML051090200).

The application for SQN Unit 1 to adopt the alternative TS requirements for ensuring SG tube integrity was dated August 31, 2005 (ADAMS Accession No. ML052500560). On February 23, 2006, the NRC staff issued Amendment No. 306 to the SQN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML060550100).

The application for SQN Unit 2 to adopt the alternative TS requirements for ensuring SG tube integrity was dated February 15, 2006 (ADAMS Accession No. ML060600405). The original application was supplemented by letters dated August 7, 2006 (ADAMS Accession No. ML062280054), August 30, 2006 (ADAMS Accession No. ML062500211), November 30, 2006 (ADAMS Accession No. ML063390665), and April 2, 2007 (ADAMS Accession No. ML071010153). On May 22, 2007, the NRC staff issued Amendment No. 305 to the SQN Unit 2 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML071210013).

W. R. Campbell, Jr. The application for WBN Unit 1 to adopt the alternative TS requirements for ensuring SG tube integrity was dated December 15, 2005 (ADAMS Accession No. ML053540067). The original application was supplemented by letters dated June 12, 2006 (ADAMS Accession No. ML061650267) and September 8, 2006 (ADAMS Accession No. ML062550371). On November 3, 2006, the NRC staff issued Amendment No. 65 to the WBN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML062910090).

The NRC staff finds the licensees adoption of new SG TSs modeled after TSTF-449 to be an acceptable and complete response to GL 2006-01. This completes the NRC staffs efforts on TAC Nos. MD0110, MD0111 and MD0121. If you have any questions regarding this letter, please contact me at 301-415-3974.

Sincerely,

/RA/

Brendan T. Moroney, Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-327, 50-328 and 50-390 cc: See next page

ML053540067). The original application was supplemented by letters dated June 12, 2006 (ADAMS Accession No. ML061650267) and September 8, 2006 (ADAMS Accession No. ML062550371). On November 3, 2006, the NRC staff issued Amendment No. 65 to the WBN Unit 1 Facility Operating License, which approved new SG TSs (ADAMS Accession No. ML062910090).

The NRC staff finds the licensees adoption of new SG TSs modeled after TSTF-449 to be an acceptable and complete response to GL 2006-01. This completes the NRC staffs efforts on TAC Nos. MD0110, MD0111 and MD0121. If you have any questions regarding this letter, please contact me at 301-415-3974.

Sincerely,

/RA/

Brendan T. Moroney, Project Manager Plant Licensing Branch II-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-327, 50-328 and 50-390 cc: See next page DISTRIBUTION:

PUBLIC LPLII-2 r/f RidsNrrDorlLpl2-2 RidsNrrPMBMoroney RidsNrrLACSola RidsOgcRp RidsAcrsAcnwMailCenter RidsNrrDirsltsb RidsRgn2MailCenter RidsNrrDorlDpr RidsNrrCsgb DBeaulieu, NRR KKarwoski, NRR ADAMS ACCESSION NO: ML071500010 OFFICE LPL2-2/PM LPL2-2/LA NRR/CSGB/BC LPL2-2/BC NAME BMoroney RSola AHiser TBoyce DATE 6/7/07 6/7/07 6 /06/07 6/7/07 Page 1 of 2 William R. Campbell, Jr. SEQUOYAH NUCLEAR PLANT Tennessee Valley Authority WATTS BAR NUCLEAR PLANT cc:

Mr. Ashok S. Bhatnagar Mr. John C. Fornicola, Manager Senior Vice President Nuclear Assurance Nuclear Generation Development Tennessee Valley Authority and Construction 6A Lookout Place Tennessee Valley Authority 1101 Market Street 6A Lookout Place Chattanooga, TN 37402-2801 1101 Market Street Chattanooga, TN 37402-2801 Mr. Robert H. Bryan, Jr., General Manager Licensing and Industry Affairs Mr. Preston D. Swafford Tennessee Valley Authority Senior Vice President 4X Blue Ridge Nuclear Support 1101 Market Street Tennessee Valley Authority Chattanooga, TN 37402-2801 6A Lookout Place 1101 Market Street Ms. Beth A. Wetzel, Manager Chattanooga, TN 37402-2801 Corporate Nuclear Licensing and Industry Affairs Mr. Walter M. Justice II Tennessee Valley Authority Interim Vice President 4X Blue Ridge Nuclear Engineering & Technical Services 1101 Market Street Tennessee Valley Authority Chattanooga, TN 37402-2801 6A Lookout Place 1101 Market Street Mr. Glenn W. Morris, Manager Chattanooga, TN 37402-2801 Licensing and Industry Affairs Sequoyah Nuclear Plant Mr. Michael D. Skaggs, Site Vice President Tennessee Valley Authority Watts Bar Nuclear Plant P.O. Box 2000 Tennessee Valley Authority Soddy Daisy, TN 37384-2000 P.O. Box 2000 Spring City, TN 37381 Mr. David A. Kulisek, Plant Manager Sequoyah Nuclear Plant Mr. Randy Douet, Site Vice President Tennessee Valley Authority Sequoyah Nuclear Plant P.O. Box 2000 Tennessee Valley Authority Soddy Daisy, TN 37384-2000 P.O. Box 2000 Soddy Daisy, TN 37384-2000 Senior Resident Inspector Sequoyah Nuclear Plant General Counsel U.S. Nuclear Regulatory Commission Tennessee Valley Authority 2600 Igou Ferry Road ET 11A Soddy Daisy, TN 37379 400 West Summit Hill Drive Knoxville, TN 37902 County Mayor Hamilton County Courthouse Chattanooga, TN 37402-2801

Page 2 of 2 William R. Campbell, Jr. SEQUOYAH NUCLEAR PLANT Tennessee Valley Authority WATTS BAR NUCLEAR PLANT cc:

Mr. James D. Smith, Acting Manager Licensing and Industry Affairs Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381 Mr. Michael J. Lorek, Plant Manager Watts Bar Nuclear Plant Tennessee Valley Authority P.O. Box 2000 Spring City, TN 37381 Senior Resident Inspector Watts Bar Nuclear Plant U.S. Nuclear Regulatory Commission 1260 Nuclear Plant Road Spring City, TN 37381 County Executive 375 Church Street Suite 215 Dayton, TN 37321 County Mayor P. O. Box 156 Decatur, TN 37322 Mr. Lawrence E. Nanney, Director Division of Radiological Health Dept. of Environment & Conservation Third Floor, L and C Annex 401 Church Street Nashville, TN 37243-1532 Ms. Ann P. Harris 341 Swing Loop Road Rockwood, TN 37854