ML13248A111: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(Created page by program invented by StriderTol)
 
(One intermediate revision by the same user not shown)
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:Admin-130 2.1S Page 1 of 12   REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE
{{#Wiki_filter:Admin-130 2.1S Page 1 of 12 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Admin-130 Perform Manual RCS Leakage Calculation and TS Determination (SRO Only)
CANDIDATE EXAMINER


Admin-130  Perform Manual RCS Leakage Calculation and TS Determination (SRO Only)
Admin-130 2.1S Page 2 of 12 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:
CANDIDATE      EXAMINER Admin-130 2.1S Page 2 of 12 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:   Perform Manual RCS Leakage Calculation and T S Determination Alternate Path:
Perform Manual RCS Leakage Calculation and TS Determination Alternate Path:
 
N/A Facility JPM #:
N/A Facility JPM #:
CRO-43 K/A Rating(s):
CRO-43 K/A Rating(s):
System: Gen K/A:     2.1.7 Rating: 4.4/4.7 Task Standard:
System: Gen K/A: 2.1.7 Rating: 4.4/4.7 Task Standard:
RCS Leakage is calculated per the attached key.
RCS Leakage is calculated per the attached key.
TS 3.4.13 Condition B entered. Preferred Evaluation Location:
TS 3.4.13 Condition B entered.
Preferred Evaluation Method:
Preferred Evaluation Location:                                   Preferred Evaluation Method:
Simulator _____ In-Plant __ ___ Classroom __X___   Perform __X___ Simulate __ __
Simulator _____ In-Plant __ ___ Classroom __X___                 Perform __X___ Simulate __ __


==References:==
==References:==


PT/O/A/0600/001A (Loss Of Computer
PT/O/A/0600/001A (Loss Of Computer)
) PT/1/A/0 600/010 (Reactor Coolant Leakage
PT/1/A/0600/010 (Reactor Coolant Leakage)
) TS 3.4.13 (RCS Operational LEAKAGE
TS 3.4.13 (RCS Operational LEAKAGE)
Validation Time:
Validation Time: 18 minutes                                             Time Critical: NO
18 minutes Time Critical:
=====================================================================================
NO =====================================================================================
Candidate:     _______________________________________                       Time Start: ____________
Candidate:
NAME                                           Time Finish: ___________
_______________________________________
Performance Rating: SAT ______ UNSAT ______                             Performance Time ___________
Time Start: ____________     NAME Time Finish: ___
Examiner: ______________________________           ____________________________________/_________
________  Performance Rating:
NAME                                     SIGNATURE                     DATE
SAT ______ UNSAT ______
=====================================================================================
Performance Time ___________
COMMENTS
Examiner: ______________________________         ____________________________________/_________   NAME     SIGNATURE                           DATE
=====================================================================================
COMMENTS Admin-130 2.1S Page 3 of 12 SIMULATOR OPERATOR INSTRUCTIONS NONE Admin-130 2.1S Page 4 of 12 Tools/Equipment/Procedures Needed:
PT/1/A/0600/0 10 (Reactor Coolant Leakage)
Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet)
Technical Specifications


READ TO OPERATOR DIRECTION TO TRAINEE
Admin-130 2.1S Page 3 of 12 SIMULATOR OPERATOR INSTRUCTIONS NONE


I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
Admin-130 2.1S Page 4 of 12 Tools/Equipment/Procedures Needed:
INITIAL CONDITIONS
PT/1/A/0600/010 (Reactor Coolant Leakage) Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet)
Technical Specifications READ TO OPERATOR DIRECTION TO TRAINEE I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
INITIAL CONDITIONS Oconee Unit 1 computer repairs are expected to be extended through turnover for hardware replacement. The Loss of Computer procedure PT/O/A/0600/001A, Loss of Computer, is in progress; however an RCS Leakage Calculation has not been performed during this shift.
INITIATING CUES The OSM directs you to perform a manual RCS leakage calculation per PT/1A/0600/010 (Reactor Coolant Leakage) Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet) using the data collected below.
Evaluate leakage and determine if any Tech Spec Conditions that apply.
Manual RCS Leakage Data Parameter                        Initial            Final Time                                                0015              0115 Pzr level                                      219.0 inches      219.5 inches Tave Indication                                  579.0°F          579.1°F Quench Tank Level                              86.5 inches        86.5 inches LDST Level                                    76.7 inches        75.2 inches Power Range NI                                    100.0%            100.1%
RCS NR Pressure                                2150 psig          2150 psig Group 7 Control Rod Position                      92.7%            92.7%


Oconee Unit 1 computer repairs are expected to be extended through turnover for hardware replacement. The Loss of Computer procedure PT/O/A/0600/001A, Loss of Computer, is in progress; however an RCS Leakage Calculation has not been performed during this shift.
Admin-130 2.1S Page 5 of 12 START TIME: _______
INITIATING CUES
STEP 1:    Step 2.1 Record Initial Data in "Table #1".
Value      Initial Data        Minus        Final Data        Equals      Change PZR Level  219.0 inches            -                              =
RCS Temp    579.0°F                -                              =
QT Level    86.5 inches            -                              =                ____Sat LDST Level  76.7 inches            -                              =
Rx Power    100.0%                  -                              =
RCS Press  2150 psig              -                              =              ____Unsat CR Pos      92.7%                  -                              =
STANDARD:  Candidate enters initial set of data into Table #1 of Enclosure 13.3 (Manual Leakage Calculation Data Sheet) from the initiating cue.
COMMENTS STEP 2:    Step 2.2 Record time Initial Data recorded: ____________
____Sat STANDARD:  Candidate enters 0015 (from initiating cue)
COMMENTS                                                                            ____Unsat


The OSM directs you to perform a manual RCS leakage calculation per PT/1 A/0 600/0 10 (Reactor Coolant Leakage)
Admin-130 2.1S Page 6 of 12 STEP 3:    Step 2.3 After 1 hour, record Final Data in "Table #1".
Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet) using the data collected below.
Value      Initial Data        Minus        Final Data        Equal      Change PZR Level  219.0 inches            -        219.5 inches        =
RCS Temp  579.0°F                  -        579.1°F              =
QT Level  86.5 inches              -        86.5 inches          =
LDST Level 76.7 inches              -        75.2 inches          =                ____Sat Rx Power  100.0%                  -        100.1%              =
RCS Press  2150 psig                -        2150 psig            =
CR Pos    92.7%                    -        92.7%                =                ____Unsat STANDARD:  Candidate enters final set of data into Table #1 of Enclosure 13.3 (Manual Leakage Calculation Data Sheet) (from initiating cue)
COMMENTS STEP 4:    Step 2.4 Record time Final Data recorded: ____________
____Sat STANDARD:  Candidate enters 0115 COMMENTS                                                                          ____Unsat STEP 5:    Step 2.5                                                              CRITICAL STEP Record time elapsed time: ____________ minutes STANDARD:  Candidate enters 60 minutes
____Sat COMMENTS
____Unsat


Evaluate leakage and determine if a ny Tech S pec Conditions that apply. Manual RCS Leakage Data Parameter Initial Final Time 0015 0115 Pzr level 219.0 inches 219.5 inches Tave Indication 579.0°F 579.1°F Quench Tank Level 8 6.5 inches 8 6.5 inches LDST Level 76.7 inches 7 5.2 inches Power Range NI 100.0% 100.1% RCS NR Pressure 2150 psig 2150 psig Group 7 Control Rod Position 9 2.7% 9 2.7%
Admin-130 2.1S Page 7 of 12 STEP 6:   Step 2.6                                                                  CRITICAL STEP Calculate and record "Change" values in "Table # 1"..
Admin-130 2.1S Page 5 of 12 START TIME: _______
Value     Initial Data       Minus       Final Data         Equal      Change PZR Level 219.0 inches           -       219.5 inches         =       -.5 inches RCS Temp   579.0°F                 -       579.1°F               =       -.1°F          ____Sat QT Level   86.5 inches             -       86.5 inches           =       0 inches LDST Level 76.7 inches             -       75.2 inches           =       +1.5 inches Rx Power   100.0%                 -       100.1%               =       -.1%          ____Unsat RCS Press 2150 psig               -       2150 psig             =       0 psig CR Pos     92.7%                   -       92.7%                 =       0%
STEP 1: Step 2.1 Record Initial Data in "Table #1".
STANDARD: Candidate calculates the change in data and fills in Table 1 change column.
____Sat  ____Unsat    Value Initial Data Minus Final Data Equals Change PZR Level 219.0 inches - =  RCS Temp 579.0°F -  =  QT Level 86.5 inches -  =  LDST Level 76.7 inches -  = Rx Power 100.0% - =  RCS Press 2150 psig -  =  CR Pos 92.7% -  =  STANDARD: Candidate enters initial set of data into "Table #1" of Enclosure 13.3 (Manual Leakage Calculation Data Sheet) from the initiating cue.
COMMENTS STEP :7    Step 2.7                                                                  CRITICAL STEP Calculate Corrected Pzr Level Change:
COMMENTS STEP 2: Step 2.2 Record time Initial Data recorded: ____________
STANDARD: -0.5 inches - (6.831 inches/°F X -.1°F) = +.1831 inches                      ____Sat
STANDARD: Candidate enters 0015 (from initiating cue)
(+.18 to +.2)
COMMENTS
____Unsat COMMENTS STEP :8    Step 2.8                                                                  CRITICAL STEP Convert Corrected Pzr Level Change to gallons STANDARD: +.1831 inches X 14.364 gallons / inch = +2.63 gallons
____Sat  ____Unsat Admin-130 2.1S Page 6 of 12  STEP 3: Step 2.3 After 1 hour, record Final Data in "Table
____Sat
#1". ____Sat  ____Unsat  Value Initial Data Minus Final Data Equal Change PZR Level 219.0 inches
(+.18 to +.2)                            ( 2.585 to 2.873)
- 219.5 inches
COMMENTS                                                                              ____Unsat
RCS Temp 579.0°F - 579.1°F = QT Level 86.5 inches - 86.5 inches = LDST Level 76.7 inches - 7 5.2 inches = Rx Power 100.0% - 100.1% = RCS Press 2150 psig - 2150 psig = CR Pos 92.7% - 92.7% =   STANDARD: Candidate enters final set of data into "Table #1" of Enclosure 13.3 (Manual Leakage Calculation Data Sheet) (from initiating cue)
COMMENTS   STEP 4: Step 2.4 Record time Fi n al Data recorded: ____________
STANDARD: Candidate enters 0115 COMMENTS    ____Sat   ____Unsat STEP 5: Step 2.5 Record time elapsed time: ____________ minutes STANDARD: Candidate enters 60 minutes COMMENTS    CRITICAL STEP
____Sat   ____Unsat Admin-130 2.1S Page 7 of 12  STEP 6: Step 2.6 Calculate and record "Change" values in "Table # 1"..
CRITICAL STEP


____Sat  ____Unsat  Value Initial Data Minus Final Data Equal Change PZR Level 219.0 inches
Admin-130 2.1S Page 8 of 12 STEP :Step 2.9                                                          CRITICAL STEP Convert QT Level Change to gallons:
- 219.5 inches
STANDARD: No change
= -.5 inches RCS Temp 579.0°F - 579.1°F = -.1°F QT Level 86.5 inches - 86.5 inches = 0 inches LDST Level 76.7 inches - 7 5.2 inches = +1.5 inches Rx Power 100.0% - 100.1% = -.1% RCS Press 2150 psig - 2150 psig = 0 psig CR Pos 92.7% - 92.7% = 0 %  STANDARD: Candidate calculates the change in data and fills in Table 1 change column. COMMENTS    STEP :7 Step 2.7 Calculate Corrected Pzr Level Change:
____Sat COMMENTS
STANDARD: -0.5 inches - (6.831 inches/°F X
____Unsat STEP :10  Step 2.10                                                        CRITICAL STEP Convert LDST Level Change to gallons STANDARD: +1.5 inches X 30.956 gallons / inch = +46.434 gallons
-.1°F) = +.1831 inches
(+.18 to +.2)  COMMENTS CRITICAL STEP
____Sat  ____Unsat STEP :8 Step 2.8 Convert Corrected Pzr Level Change to gallons STANDARD: +.1831 inches X 14.364 gallons / inch =  
+2.63 gallons  (+.18 to +.2)    ( 2.585 to 2.873)  COMMENTS    CRITICAL STEP
____Sat  ____Unsat Admin-130 2.1S Page 8 of 12  STEP :9 Step 2.9 Convert QT Level Change to gallons:
STANDARD: No change COMMENTS    CRITICAL STEP
____Sat
____Sat
____Unsat STEP :10 Step 2.10 Convert LDST Level Change to gallons STANDARD: +1.5 inches X 30.956 gallons / inch =
(+46.4 to +46.5)
+46.434 gallons             (+46.4 to +46.5)  COMMENTS    CRITICAL STEP
COMMENTS                                                                      ____Unsat STEP :11  Step 2.11                                                        CRITICAL STEP Calculate Total Volume Change STANDARD: 2.63 gallons + 0 gallons + 46.434 gallons = 49.064 gallons
____Sat
____Sat
____Unsat  STEP :11 Step 2.11 Calculate Total Volume Change STANDARD: 2.63 gallons + 0 gallons + 46.434 gallons = 49.064 gallons  ( 2.585 to 2.873)     (+46.4 to +46.5) (48.98 to 49.37) COMMENTS   CRITICAL STEP
( 2.585 to 2.873)         (+46.4 to +46.5)     (48.98 to 49.37)
____Sat
COMMENTS                                                                     ____Unsat STEP :12 Step 2.12                                                         CRITICAL STEP Calculate "RCS Unidentified Leakage Rate" STANDARD: 49.064 gallons / 60 minutes = .818 gpm
____Unsat STEP :12 Step 2.12 Calculate "RCS Unidentified Leakage Rate" STANDARD: 49.064 gallons / 60 minutes = .818 gpm (48.98 to 49.37)   (.816 to .823) COMMENTS   CRITICAL STEP
____Sat (48.98 to 49.37)                 (.816 to .823)
____Sat
COMMENTS                                                                     ____Unsat
____Unsat Admin-130 2.1S Page 9 of 12 STEP :13 Refer to TS 3.4.13 RCS Operational LEAKAGE STANDARD: Candidate determines that the Tech Spec limit for Unidentified Leakage is 1 gpm therefore entry into the Actions Table is NOT required
 
. COMMENTS      ____Sat
Admin-130 2.1S Page 9 of 12 STEP :13   Refer to TS 3.4.13 RCS Operational LEAKAGE STANDARD:   Candidate determines that the Tech Spec limit for Unidentified Leakage   ____Sat is 1 gpm therefore entry into the Actions Table is NOT required.
____Unsat STEP :1 4 Refer to TS 3.4.13 RCS Operational LEAKAGE EXAMINER CUE: Hand the candidate Cue sheet #2 STANDARD: NOTE: After second cue sheet handed to candidate, he/she determines the leakage is pressure boundary leakage (see below)
____Unsat COMMENTS STEP :14    Refer to TS 3.4.13 RCS Operational LEAKAGE                             CRITICAL STEP EXAMINER CUE: Hand the candidate Cue sheet #2
____Sat STANDARD:
NOTE: After second cue sheet handed to candidate, he/she
____Unsat determines the leakage is pressure boundary leakage (see below)
Pressure Boundary: Determine that leakage exceeds the 0 gpm Pressure Boundary leakage limit and TS 3.4.13 Condition B applies. This required Mode 3 in 12 hours and Mode 5 in 36 hours.
Pressure Boundary: Determine that leakage exceeds the 0 gpm Pressure Boundary leakage limit and TS 3.4.13 Condition B applies. This required Mode 3 in 12 hours and Mode 5 in 36 hours.
COMMENTS   END TASK CRITICAL STEP
COMMENTS END TASK STOP TIME: ____________
____Sat   ____Unsat   STOP TIME: ____________
 
Admin-130 2.1S Page 10 of 12 CRITICAL STEP EXPLANATIONS STEP #                                    Explanation 5  Necessary data calculation to properly determine manual RCS leakage rate.
6  Necessary data calculation to properly determine manual RCS leakage rate.
7  Necessary data calculation to properly determine manual RCS leakage rate.
8  Necessary data calculation to properly determine manual RCS leakage rate.
9  Necessary data calculation to properly determine manual RCS leakage rate.
10  Necessary data calculation to properly determine manual RCS leakage rate.
11  Necessary data calculation to properly determine manual RCS leakage rate.
12  Necessary data calculation to properly determine manual RCS leakage rate.
13   Necessary to refer to correct TS and conclude limits are not exceeded.
14   Necessary to refer to correct TS and conclude limits are exceeded.


Admin-130 2.1S Page 10 of 12  CRITICAL STEP EXPLANATIONS STEP # Explanation 5 Necessary data calculation to properly determine manual RCS leakage rate.
1.1S CANDIDATE CUE SHEET #1 (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
6 Necessary data calculation to properly determine manual RCS leakage rate.
7 Necessary data calculation to properly determine manual RCS leakage rate.
8 Necessary data calculation to properly determine manual RCS leakage rate.
9 Necessary data calculation to properly determine manual RCS leakage rate.
10 Necessary data calculation to properly determine manual RCS leakage rate.
11 Necessary data calculation to properly determine manual RCS leakage rate.
12 Necessary data calculation to properly determine manual RCS leakage rate.
13 Necessary to refer to correct TS and conclude limits are not exceeded. 1 4 Necessary to refer to correct TS and conclude limits are exceeded
.
1.1S   CANDIDATE CUE SHEET
#1 (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
INITIAL CONDITIONS Oconee Unit 1 computer repairs are expected to be extended through turnover for hardware replacement. The Loss of Computer procedure PT/O/A/0600/001A, Loss of Computer, is in progress; however an RCS Leakage Calculation has not been performed during this shift.
INITIAL CONDITIONS Oconee Unit 1 computer repairs are expected to be extended through turnover for hardware replacement. The Loss of Computer procedure PT/O/A/0600/001A, Loss of Computer, is in progress; however an RCS Leakage Calculation has not been performed during this shift.
INITIATING CUES
INITIATING CUES The OSM directs you to perform a manual RCS leakage calculation per PT/1A/0600/010 (Reactor Coolant Leakage) Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet) using the data collected below.
Evaluate leakage and determine if any Tech Spec Conditions that apply.
Manual RCS Leakage Data Parameter                    Initial            Final Time                                        0015              0115 Pzr level                              219.0 inches      219.5 inches Tave Indication                            579.0°F          579.1°F Quench Tank Level                        86.5 inches      86.5 inches LDST Level                              76.7 inches      75.2 inches Power Range NI                            100.0%            100.1%
RCS NR Pressure                          2150 psig        2150 psig Group 7 Control Rod Position                92.7%            92.7%


The OSM directs you to perform a manual RCS leakage calculation per PT/1A/0600/010 (Reactor Coolant Leakage) Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet) using the data collected below.
1.1S CANDIDATE CUE SHEET #2 (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
 
INITIATING CUES Since completing the RCS Manual Leakage calculation, the RCS leak rate has increased to 2.17 gpm and the location of the leak has been determined to be the weld that connects the 1A1 HPI injection nozzle to the RCS piping.
Evaluate leakage and determine if any Tech Spec Conditions that apply.
Manual RCS Leakage Data Parameter Initial Final Time 0015 0115 Pzr level 219.0 inches 219.5 inches Tave Indication 579.0°F 579.1°F Quench Tank Level 8 6.5 inches 8 6.5 inches LDST Level 76.7 inches 7 5.2 inches Power Range NI 100.0% 100.1% RCS NR Pressure 2150 psig 2150 psig Group 7 Control Rod Position 9 2.7% 9 2.7%
1.1S CANDIDATE CUE SHEET #2 (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)   INITIATING CUES Since completing the RCS Manual Leakage calculation, the RCS leak rate has increased to 2.17 gpm and the location of the leak has been determined to be the weld that connects the 1A1 HPI injection nozzle to the RCS piping.
Indicate below what (if any) Tech Spec Conditions, Required Actions, and Completion Times that apply.
Indicate below what (if any) Tech Spec Conditions, Required Actions, and Completion Times that apply.


Admin-131 1.1R Page 1 of 10   REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE
Admin-131 1.1R Page 1 of 10 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Admin-131 Perform Manual RCS Leakage Calculation (RO Only)
 
CANDIDATE EXAMINER
Admin-131 Perform Manual RCS Leakage Calculation (RO Only)        
 
CANDIDATE     EXAMINER  
 
Admin-131 1.1R Page 2 of 10  REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:  Perform Manual RCS Leakage Calculation Alternate Path:


N/A Facility JPM #:
Admin-131 1.1R Page 2 of 10 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:
CRO-43 K/A Rating(s):
Perform Manual RCS Leakage Calculation Alternate Path:
System: Gen K/A: 2.1.7 Rating: 4.4/4.7 Task Standard:
N/A Facility JPM #:
CRO-43 K/A Rating(s):
System: Gen K/A:     2.1.7 Rating: 4.4/4.7 Task Standard:
RCS Leakage is calculated per the attached key.
RCS Leakage is calculated per the attached key.
Preferred Evaluation Location:
Preferred Evaluation Location:                                   Preferred Evaluation Method:
Preferred Evaluation Method:
Simulator _____ In-Plant __ ___ Classroom __X___                 Perform __X___ Simulate __ __
Simulator _____ In-Plant __ ___ Classroom __X___   Perform __X___ Simulate __ __


==References:==
==References:==


PT/O/A/0600/001A (Loss Of Computer
PT/O/A/0600/001A (Loss Of Computer)
) PT/1/A/0 600/010 (Reactor Coolant Leakage
PT/1/A/0600/010 (Reactor Coolant Leakage)
Validation Time:
Validation Time: 18 minutes                                             Time Critical: NO
18 minutes Time Critical: NO =====================================================================================
=====================================================================================
Candidate:
Candidate:     _______________________________________                       Time Start: ____________
_______________________________________
NAME                                           Time Finish: ___________
Time Start: ____________     NAME Time Finish: ___
Performance Rating: SAT ______ UNSAT ______                             Performance Time ___________
________  Performance Rating:
Examiner: ______________________________           ____________________________________/_________
SAT ______ UNSAT ______
NAME                                     SIGNATURE                     DATE
Performance Time ___________
=====================================================================================
Examiner: ______________________________         ____________________________________/___
COMMENTS
______    NAME     SIGNATURE                           DATE
=====================================================================================
COMMENTS Admin-131 1.1R Page 3 of 10 SIMULATOR OPERATOR INSTRUCTIONS NONE Admin-131 1.1R Page 4 of 10 Tools/Equipment/Procedures Needed PT/1/A/0600/0 10 (Reactor Coolant Leakage)
Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet)


READ TO OPERATOR DIRECTION TO TRAINEE
Admin-131 1.1R Page 3 of 10 SIMULATOR OPERATOR INSTRUCTIONS NONE


I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
Admin-131 1.1R Page 4 of 10 Tools/Equipment/Procedures Needed PT/1/A/0600/010 (Reactor Coolant Leakage) Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet)
INITIAL CONDITIONS
READ TO OPERATOR DIRECTION TO TRAINEE I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
INITIAL CONDITIONS Oconee Unit 1 computer repairs are expected to be extended through turnover for hardware replacement. The Loss of Computer procedure PT/O/A/0600/001A, Loss of Computer, is in progress, however an RCS Leakage Calculation has not been performed during this shift.
INITIATING CUES The Control Room SRO directs you to perform a manual RCS leakage calculation per PT/1A/0600/010 (Reactor Coolant Leakage) Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet) using the data collected below.
Manual RCS Leakage Data Parameter                        Initial            Final Time                                                0015              0115 Pzr level                                      219.0 inches      219.5 inches Tave Indication                                  579.0°F          579.1°F Quench Tank Level                              86.5 inches        86.5 inches LDST Level                                    76.7 inches        74.0 inches Power Range NI                                    100.0%            100.1%
RCS NR Pressure                                2150 psig          2150 psig Group 7 Control Rod Position                      92.7%            92.7%


Oconee Unit 1 computer repairs are expected to be extended through turnover for hardware replacement. The Loss of Computer procedure PT/O/A/0600/001A, Loss of Computer, is in progress, however an RCS Leakage Calculation has not been performed during this shift.
Admin-131 1.1R Page 5 of 10 START TIME: _______
INITIATING CUES
STEP 1:    Step 2.1 Record Initial Data in "Table #1".
Value      Initial Data        Minus        Final Data        Equals      Change PZR Level  219.0 inches            -                              =
RCS Temp    579.0°F                -                              =
QT Level    86.5 inches            -                              =                ____Sat LDST Level  76.7 inches            -                              =
Rx Power    100.0%                  -                              =
RCS Press  2150 psig              -                              =              ____Unsat CR Pos      92.7%                  -                              =
STANDARD:  Student enters initial set of data into Table #1 of Enclosure 13.3 (Manual Leakage Calculation Data Sheet) from the initiating cue.
COMMENTS STEP 2:    Step 2.2 Record time Initial Data recorded: ____________
____Sat STANDARD:  Student enters 0015 (from initiating cue)
COMMENTS                                                                            ____Unsat


The Control Room SRO directs you to perform a manual RCS leakage calculation per PT/1 A/0 600/010 (Reactor Coolant Leakage)
Admin-131 1.1R Page 6 of 10 STEP 3:    Step 2.3 After 1 hour, record Final Data in "Table #1".
Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet) using the data collected below.
Value      Initial Data        Minus        Final Data        Equal    Change PZR Level  219.0 inches            -        219.5 inches        =
RCS Temp  579.0°F                  -        579.1°F            =
QT Level  86.5 inches              -        86.5 inches        =
LDST Level 76.7 inches              -        74.0 inches        =                      ____Sat Rx Power  100.0%                  -        100.1%              =
RCS Press  2150 psig                -        2150 psig          =
CR Pos    92.7%                    -        92.7%              =                    ____Unsat STANDARD:  Student enters final set of data into Table #1 of Enclosure 13.3 (Manual Leakage Calculation Data Sheet) (from initiating cue)
COMMENTS STEP 4:    Step 2.4 Record time Final Data recorded: ____________
____Sat STANDARD:  Student enters 0115 COMMENTS                                                                                ____Unsat STEP 5:    Step 2.5                                                                  CRITICAL STEP Record time elapsed time: ____________ minutes STANDARD:  Student enters 60 minutes
____Sat COMMENTS
____Unsat


Manual RCS Leakage Data Parameter Initial Final Time 0015 0115 Pzr level 219.0 inches 219.5 inches Tave Indication 579.0°F 579.1°F Quench Tank Level 8 6.5 inches 8 6.5 inches LDST Level 76.7 inches 74.0 inches Power Range NI 100.0% 100.1% RCS NR Pressure 2150 psig 2150 psig Group 7 Control Rod Position 9 2.7% 9 2.7%
Admin-131 1.1R Page 7 of 10 STEP 6:   Step 2.6                                                                  CRITICAL STEP Calculate and record "Change" values in "Table # 1"..
Admin-131 1.1R Page 5 of 10 START TIME: _______
Value     Initial Data       Minus       Final Data         Equal    Change PZR Level 219.0 inches           -       219.5 inches          =       -.5 inches RCS Temp   579.0°F                 -       579.1°F              =       -.1°F          ____Sat QT Level   86.5 inches             -       86.5 inches          =       0 inches LDST Level 76.7 inches             -       74.0 inches          =       +2.7 inches Rx Power   100.0%                 -       100.1%                =       -.1%          ____Unsat RCS Press 2150 psig               -       2150 psig            =       0 psig CR Pos     92.7%                   -       92.7%                =       0%
STEP 1: Step 2.1 Record Initial Data in "Table #1".
STANDARD: Student calculates the change in data and fills in Table 1 change column.
____Sat  ____Unsat    Value Initial Data Minus Final Data Equals Change PZR Level 219.0 inches - = RCS Temp 579.0°F - = QT Level 86.5 inches - = LDST Level 76.7 inches - = Rx Power 100.0% - = RCS Press 2150 psig - = CR Pos 92.7% - =   STANDARD: Student enters initial set of data into "Table #1" of Enclosure 13.3 (Manual Leakage Calculation Data Sheet) from the initiating cue.
COMMENTS STEP :7    Step 2.7                                                                  CRITICAL STEP Calculate Corrected Pzr Level Change:
COMMENTS STEP 2: Step 2.2 Record time Initial Data recorded: ____________
____Sat STANDARD:  -0.5 inches - (6.831 inches/°F X -.1°F) = +.1831 inches
STANDARD: Student enters 0015 (from initiating cue)
(+.18 to +.2)
____Unsat COMMENTS STEP :8    Step 2.8                                                                  CRITICAL STEP Convert Corrected Pzr Level Change to gallons STANDARD:  +.1831 inches X 14.364 gallons / inch = +2.63 gallons
____Sat
(+.18 to +.2)                            ( 2.585 to 2.873)
COMMENTS
COMMENTS
____Sat  ____Unsat Admin-131 1.1R Page 6 of 10  STEP 3: Step 2.3 After 1 hour, record Final Data in "Table #1".
____Unsat
____Sat  ____Unsat  Value Initial Data Minus Final Data Equal Change PZR Level 219.0 inches
- 219.5 inches
=  RCS Temp 579.0°F - 579.1°F =  QT Level 86.5 inches - 86.5 inches =  LDST Level 76.7 inches - 74.0 inches
=  Rx Power 100.0% - 100.1% =  RCS Press 2150 psig - 2150 psig =  CR Pos 92.7% - 92.7% =  STANDARD: Student enters final set of data into "Table #1" of Enclosure 13.3 (Manual Leakage Calculation Data Sheet) (from initiating cue)
COMMENTS    STEP 4: Step 2.4 Record time Fi n al Data recorded: ____________
STANDARD: Student enters 0115 COMMENTS
____Sat  ____Unsat  STEP 5: Step 2.5 Record time elapsed time: ____________ minutes STANDARD: Student enters 60 minutes COMMENTS    CRITICAL STEP
____Sat  ____Unsat Admin-131 1.1R Page 7 of 10  STEP 6: Step 2.6 Calculate and record "Change" values in "Table # 1"..
CRITICAL STEP


____Sat  ____Unsat  Value Initial Data Minus Final Data Equal Change PZR Level 219.0 inches
Admin-131 1.1R Page 8 of 10 STEP :9    Step 2.9                                                    CRITICAL STEP Convert QT Level Change to gallons:
- 219.5 inches
STANDARD:   No change
= -.5 inches RCS Temp 579.0°F - 579.1°F = -.1°F QT Level 86.5 inches - 86.5 inches = 0 inches LDST Level 76.7 inches
____Sat COMMENTS
- 74.0 inches
____Unsat STEP :10    Step 2.10                                                    CRITICAL STEP Convert LDST Level Change to gallons STANDARD:   +2.7 inches X 30.956 gallons / inch = +83.5812 gallons
= +2.7 inches Rx Power 100.0% - 100.1% = -.1% RCS Press 2150 psig - 2150 psig = 0 psig CR Pos 92.7% - 92.7% = 0 %  STANDARD: Student calculates the change in data and fills in Table 1 change column.
COMMENTS   STEP :7 Step 2.7 Calculate Corrected Pzr Level Change:
STANDARD: -0.5 inches - (6.831 inches/°F X
-.1°F) = +.1831 inches
(+.18 to +.2)  COMMENTS CRITICAL STEP
____Sat
____Sat
____Unsat  STEP :8 Step 2.8 Convert Corrected Pzr Level Change to gallons STANDARD:  +.1831 inches X 14.364 gallons / inch = +2.63 gallons  (+.18 to +.2)    ( 2.585 to 2.873)  COMMENTS    CRITICAL STEP
____Sat  ____Unsat Admin-131 1.1R Page 8 of 10  STEP :9 Step 2.9 Convert QT Level Change to gallons:
STANDARD: No change COMMENTS    CRITICAL STEP
____Sat
____Unsat  STEP :10 Step 2.10 Convert LDST Level Change to gallons STANDARD: +2.7 inches X 30.956 gallons / inch = +83.5812 gallons
(+83.5 to +83.6)
(+83.5 to +83.6)
COMMENTS   CRITICAL STEP
COMMENTS                                                                   ____Unsat STEP :11   Step 2.11                                                   CRITICAL STEP Calculate Total Volume Change STANDARD:   2.63 gallons + 0 gallons + 83.5812 gallons = 86.2112 gallons
____Sat
____Sat (2.585 to 2.873) (+83.5 to +83.6)       (86.08 to 86.47)
____Unsat STEP :11 Step 2.11 Calculate Total Volume Change STANDARD: 2.63 gallons + 0 gallons + 83.5812 gallons =
COMMENTS
8 6.2112 gallons   (2.585 to 2.873)     (+83.5 to +83.6)
____Unsat STEP :12   Step 2.12                                                   CRITICAL STEP Calculate "RCS Unidentified Leakage Rate" STANDARD:   86.2112 gallons / 60 minutes = 1.437 gpm
(86.08 to 86.47) COMMENTS   CRITICAL STEP
____Sat (86.08 to 86.47)                 (1.434 to 1.441)
____Sat
COMMENTS                                                                   ____Unsat END TASK STOP TIME: ____________
____Unsat STEP :12 Step 2.12 Calculate "RCS Unidentified Leakage Rate" STANDARD: 86.2112 gallons / 60 minutes =
1.437 gpm (86.08 to 86.47
)   (1.434 to 1.44 1) COMMENTS   END TASK CRITICAL STEP
____Sat
____Unsat  STOP TIME: ____________


Admin-131 1.1R Page 9 of 10   CRITICAL STEP EXPLANATIONS:
Admin-131 1.1R Page 9 of 10 CRITICAL STEP EXPLANATIONS:
STEP # Explanation 5 Necessary data calculation to properly determine manual RCS leakage rate.
STEP #                                     Explanation 5   Necessary data calculation to properly determine manual RCS leakage rate.
6 Necessary data calculation to properly determine manual RCS leakage rate.
6   Necessary data calculation to properly determine manual RCS leakage rate.
7 Necessary data calculation to properly determine manual RCS leakage rate.
7   Necessary data calculation to properly determine manual RCS leakage rate.
8 Necessary data calculation to properly determine manual RCS leakage rate.
8   Necessary data calculation to properly determine manual RCS leakage rate.
9 Necessary data calculation to properly determine manual RCS leakage rate.
9   Necessary data calculation to properly determine manual RCS leakage rate.
10 Necessary data calculation to properly determine manual RCS leakage rate.
10   Necessary data calculation to properly determine manual RCS leakage rate.
11 Necessary data calculation to properly determine manual RCS leakage rate.
11   Necessary data calculation to properly determine manual RCS leakage rate.
12 Necessary data calculation to properly determine manual RCS leakage rate.
12   Necessary data calculation to properly determine manual RCS leakage rate.


1.1R   CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
1.1R CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
INITIAL CONDITIONS Oconee Unit 1 computer repairs are expected to be extended through turnover for hardware replacement. The Loss of Computer procedure PT/O/A/0600/001A, Loss of Computer, is in progress, however an RCS Leakage Calculation has not been performed during this shift. INITIATING CUES
INITIAL CONDITIONS Oconee Unit 1 computer repairs are expected to be extended through turnover for hardware replacement. The Loss of Computer procedure PT/O/A/0600/001A, Loss of Computer, is in progress, however an RCS Leakage Calculation has not been performed during this shift.
INITIATING CUES The Control Room SRO directs you to perform a manual RCS leakage calculation per PT/1A/0600/010 (Reactor Coolant Leakage) Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet) using the data collected below.
Manual RCS Leakage Data Parameter                      Initial          Final Time                                          0015            0115 Pzr level                                219.0 inches      219.5 inches Tave Indication                            579.0°F          579.1°F Quench Tank Level                        86.5 inches      86.5 inches LDST Level                                76.7 inches      74.0 inches Power Range NI                              100.0%            100.1%
RCS NR Pressure                            2150 psig        2150 psig Group 7 Control Rod Position                92.7%            92.7%


The Control Room SRO directs you to perform a manual RCS leakage calculation per PT/1A/0600/010 (Reactor Coolant Leakage)
Admin-142 - 1.2B Page 1 of 9 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Admin-142 Determine Time for SFP to reach 180ºF CANDIDATE EXAMINER
Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet) using the data collected below.


Manual RCS Leakage Data  Parameter Initial Final Time 0015 0115 Pzr level 219.0 inches 219.5 inches Tave Indication 579.0°F 579.1°F Quench Tank Level 8 6.5 inches 8 6.5 inches LDST Level 76.7 inches 74.0 inches Power Range NI 100.0% 100.1% RCS NR Pressure 2150 psig 2150 psig Group 7 Control Rod Position 9 2.7% 9 2.7%
Admin-142 - 1.2B Page 2 of 9 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:
Admin-142 - 1.2B Page 1 of 9 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE
Determine Time for SFP to reach 180ºF Alternate Path:
N/A Facility JPM #:
New K/A Rating(s):
System: GEN K/A:      2.1.25 Rating: 3.9/4.2 Task Standard:
Tables in AP/1-2/A/1700/035 (Loss of SFP Cooling And/Or Level) are used to determine total time required for SFP temperature to reach 180ºF Preferred Evaluation Location:                                        Preferred Evaluation Method:
Simulator _____ In-Plant _____ Classroom __ X ___                    Perform __X___ Simulate ____


Admin-142  Determine Time for SFP to reach 180
==References:==
ºF CANDIDATE      EXAMINER Admin-142 - 1.2B Page 2 of 9  REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:  Determine Time for SFP to reach 180ºF  Alternate Path:
N/A  Facility JPM #:
New  K/A Rating(s):  


System: GEN K/A: 2.1.25 Rating:   3.9/4.2  Task Standard:
AP/1-2/A/1700/035 (Loss of SFP Cooling And/Or Level)
Validation Time: 15 minutes                                          Time Critical: NO
====================================================================================
Candidate:      _______________________________________                              Time Start: _________
NAME                                                  Time Finish: ________
Performance Rating: SAT ______ UNSAT ______                                  Performance Time: _________
Examiner: ______________________________            ____________________________________/________
NAME                                          SIGNATURE                    DATE
====================================================================================
COMMENTS


Tables in AP/1
Admin-142 - 1.2B Page 3 of 9 SIMULATOR OPERATOR INSTRUCTIONS:
-2/A/1700/035 (Loss of SF P Cooling And/Or Level) are used to determine total time required for SFP temperature to reach 180
NONE
ºF  Preferred Evaluation Location:
Preferred Evaluation Method:
Simulator _____ In-Plant _____ Classroom
__ X ___  Perform __X___ Simulate ____ 


==References:==
Admin-142 - 1.2B Page 4 of 9 Tools/Equipment/Procedures Needed:
 
AP/1-2/A/1700/035 (Loss of SF P Cooling And/Or Level)  Validation Time
: 15 minutes      Time Critical
:  NO ====================================================================================
Candidate:
_______________________________________
Time Start: _____
____    NAME      Time Finish: ________
Performance Rating:
SAT ______ UNSAT ______
Performance Time
: _________
Examiner: ______________________________          ____________________________________/________
NAME      SIGNATURE                            DATE
====================================================================================
COMMENTS Admin-142 - 1.2B Page 3 of 9 SIMULATOR OPERATOR INSTRUCTIONS:
NONE Admin-142 - 1.2B Page 4 of 9 Tools/Equipment/Procedures Needed:
AP/1-2/A/1700/035 (Loss of SFP Cooling And/Or Level)
AP/1-2/A/1700/035 (Loss of SFP Cooling And/Or Level)
READ TO OPERATOR DIRECTION TO TRAINEE:
READ TO OPERATOR DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
INITIAL CONDITIONS:
INITIAL CONDITIONS:
Unit 1 is at 100% stable Unit 1 EFPD = 278 Unit 2 EFPD = 47 Unit 2 was operating at 100% when it experienced a Unit blackout SSF has been activated for Unit 2 Unit 2 RCMUP is aligned and operating 2HP-426 is being cycled to maintain Pressurizer Level as directed by AP/25 AP/1-2/A/1700/035 (Loss of SFP Cooling And/Or Level) has been initiated Unit 1 & 2 SFP level = 0" stable Unit 1 & 2 SFP temperature = 102 ºF INITIATING CUES:
* Unit 1 is at 100% stable
 
* Unit 1 EFPD = 278
* Unit 2 EFPD = 47
* Unit 2 was operating at 100% when it experienced a Unit blackout
* SSF has been activated for Unit 2
* Unit 2 RCMUP is aligned and operating
* 2HP-426 is being cycled to maintain Pressurizer Level as directed by AP/25
* AP/1-2/A/1700/035 (Loss of SFP Cooling And/Or Level) has been initiated
* Unit 1 & 2 SFP level = 0 stable
* Unit 1 & 2 SFP temperature = 102 ºF INITIATING CUES:
CRS has directed you to utilize AP/35 Enclosure 5.4 and determine the time for Unit 1&2 SFP to reach 180 ºF
CRS has directed you to utilize AP/35 Enclosure 5.4 and determine the time for Unit 1&2 SFP to reach 180 ºF


Admin-142 - 1.2B Page 5 of 9   START TIME: _______
Admin-142 - 1.2B Page 5 of 9 START TIME: _______
STEP 1:   1. Refer to tables A, B, and C below.
STEP 1:                                                               CRITICAL STEP
: 2. ONLY one row from one table below applies
: 1. Refer to tables A, B, and C below.
: 3. Check the row in Table A, B, or C that applies to current conditions, and then use Tables listed on subsequent pages of Encl 5.4, as directed, to calculate SFP heat up times. STANDARD: Candidate selects Table B and then chooses to use Table 10 based on
: 2. ONLY one row from one table below applies                 ___ SAT
: 1. SSF Event in progress for U1 or U2 with Unit letdown going to SFP AND   2. U1 and U2 each have 177 Fuel Assemblies in RB Candidate proceeds to Table 10 (page 33 of 63)
: 3. Check the row in Table A, B, or C that applies to current conditions, and then use Tables listed on subsequent pages of Encl 5.4, as directed, to calculate SFP heat up   ___ UNSAT times.
 
STANDARD: Candidate selects Table B and then chooses to use Table 10 based on
: 1. SSF Event in progress for U1 or U2 with Unit letdown going to SFP AND
: 2. U1 and U2 each have 177 Fuel Assemblies in RB Candidate proceeds to Table 10 (page 33 of 63)
COMMENTS:
COMMENTS:
CRITICAL STEP
___ SAT 
___ UNSAT Admin-142 - 1.2B Page 6 of 9  STEP 2:  Determine the Time (in days) row based on direction from page 5 of 63 STANDARD:  Candidate selects the lower EFPD unit and adds 20 which results in 67 days. Determine that 67 days is between 60 and 70 days on the far left column of Table 10 Based on guidance in Step 7 on Page 7 of 63, elects to use 60 days (the shorter time).
Note: Step 2 and Step 3 can be performed in any order COMMENTS:   


CRITICAL STEP
Admin-142 - 1.2B Page 6 of 9 STEP 2:      Determine the Time (in days) row based on direction from  CRITICAL STEP page 5 of 63
___ SAT STANDARD:
* Candidate selects the lower EFPD unit and adds 20 which results in 67 days.
___ UNSAT
* Determine that 67 days is between 60 and 70 days on the far left column of Table 10
* Based on guidance in Step 7 on Page 7 of 63, elects to use 60 days (the shorter time).
Note: Step 2 and Step 3 can be performed in any order COMMENTS:
STEP 3:      Determine initial Spent Fuel Pool Temperature column      CRITICAL STEP based on directions from page 7 of 63 Step 6.
___ SAT STANDARD:
* Actual SFP temp = 102ºF
* Temperature columns available are 100 and 105          ___ UNSAT
* Based on directions in step 6, elects to use the 105 (higher) column Note: Step 2 and Step 3 can be performed in any order COMMENTS:


___ SAT
Admin-142 - 1.2B Page 7 of 9 STEP 4:    Find the Time in hours based on the intersection of the 60 CRITICAL STEP day row and the 105 degree column.
___ SAT STANDARD: Based on the intersection of the 60 day row and the 105 degree column, determine that 16.4 hours is the time to reach 180ºF
___ UNSAT COMMENTS:
END TASK STOP TIME: ____________


___ UNSAT  STEP 3:  Determine initial Spent Fuel Pool Temperature column based on directions from page 7 of 63 Step 6
Admin-142 - 1.2B Page 8 of 9 CRITICAL STEP EXPLANATIONS:
. STANDARD:  Actual SFP temp = 102
STEP #                                     Explanation 1   Required to determine the time to reach 180 ºF 2   Required to determine the time to reach 180 ºF 3   Required to determine the time to reach 180 ºF 4   Required to determine the time to reach 180 ºF
ºF  Temperature columns available are 100 and 105 Based on directions in step 6, elects to use the 105 (higher) column Note: Step 2 and Step 3 can be performed in any order COMMENTS:
CRITICAL STEP
___ SAT 
 
___ UNSAT Admin-142 - 1.2B Page 7 of 9  STEP 4:  Find the Time in hours based on the intersection of the 60 day row and the 105 degree column.
STANDARD: Based on the intersection of the 60 day row and the 105 degree column, determine that 16.4 hours is the time to reach 180ºF  COMMENTS:    END TASK  CRITICAL STEP
 
___ SAT 
 
___ UNSAT STOP TIME: ____________
 
Admin-142 - 1.2B Page 8 of 9   CRITICAL STEP EXPLANATIONS:
STEP # Explanation 1 Required to determine the time to reach 180
ºF   2 Required to determine the time to reach 180
ºF   3 Required to determine the time to reach 180
ºF   4 Required to determine the time to reach 180
ºF                      


CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
INITIAL CONDITIONS:
INITIAL CONDITIONS:
Unit 1 is at 100% stable Unit 1 EFPD =
* Unit 1 is at 100% stable
278  Unit 2 EFPD = 47 Unit 2 was operating at 100% when it experienced a Unit blackout SSF has been activated for Unit 2 Unit 2 RCMUP is aligned and operating 2HP-426 is being cycled to maintain Pressurizer Level as directed by AP/25 AP/1-2/A/1700/035 (Loss of SFP Cooling And/Or Level) has been initiated Unit 1 & 2 SFP level = 0" stable Unit 1 & 2 SFP temperature = 102 ºF INITIATING CUES:
* Unit 1 EFPD = 278
 
* Unit 2 EFPD = 47
* Unit 2 was operating at 100% when it experienced a Unit blackout
* SSF has been activated for Unit 2
* Unit 2 RCMUP is aligned and operating
* 2HP-426 is being cycled to maintain Pressurizer Level as directed by AP/25
* AP/1-2/A/1700/035 (Loss of SFP Cooling And/Or Level) has been initiated
* Unit 1 & 2 SFP level = 0 stable
* Unit 1 & 2 SFP temperature = 102 ºF INITIATING CUES:
CRS has directed you to utilize AP/35 Enclosure 5.4 and determine the time for Unit 1&2 SFP to reach 180 ºF
CRS has directed you to utilize AP/35 Enclosure 5.4 and determine the time for Unit 1&2 SFP to reach 180 ºF


Admin-240 2R Page 1 of 9 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE
Admin-240 2R Page 1 of 9 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Admin-240 Perform SG Downcomer Temperature Surveillance CANDIDATE EXAMINER


Admin-2 40  Perform SG Downcomer Temperature Surveillance
Admin-240 2R Page 2 of 9 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:
Perform SG Downcomer Temperature Surveillance Alternate Path:
N/A Facility JPM #:
Admin-237 K/A Rating(s):
System: Gen K/A:      2.2.12 Rating: 3.7/4.1 Task Standard:
Perform SG Downcomer Temperature Surveillance by procedure for the 1A (ONLY) SG and determine that the surveillance requirement is NOT met for either of the specified computer points.
Preferred Evaluation Location:                                          Preferred Evaluation Method:
Simulator ___ __ In-Plant __ ___ Classroom __X__                        Perform __X__ Simulate _____


CANDIDATE      EXAMINER Admin-240 2R Page 2 of 9  REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:  Perform SG Downcomer Temperature Surveillance Alternate Path:
==References:==
N/A  Facility JPM #:


Admin-23 7  K/A Rating(s):
OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl 4.1 (Mode 1 & 2)
System: Gen K/A:  2.2.12 Rating:   3.7/4.1  Task Standard:
OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl. 4.19 (Channel Check Of OTSG Downcomer Temperatures)
Perform SG Downcomer Temperature Surveillance by procedure for the 1A (ONLY) SG and determine that the surveillance requirement is NOT met for either of the specified computer points
Validation Time: 18 minutes                                              Time Critical: NO
. Preferred Evaluation Location:
====================================================================================
Preferred Evaluation Method:
Candidate:      _______________________________________                                Time Start: _________
Simulator
NAME                                                    Time Finish: ________
___ __ In-Plant __ ___ Classroom __X__  Perform __X__ Simulate _____ 
Performance Rating: SAT ______ UNSAT ______                                      Performance Time: _________
 
Examiner: ______________________________                ____________________________________/________
==References:==
NAME                                            SIGNATURE                    DATE
====================================================================================
COMMENTS


OP/1/A/1105/014 (Control Room Instrumentation Operation And Information)
Admin-240 2R Page 3 of 9 SIMULATOR OPERATOR INSTRUCTIONS NONE
Encl 4.1 (Mode 1
& 2) OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl. 4.1 9 (Channel Check Of OTSG Downcomer Temperatures)
Validation Time:
18 minutes        Time Critical:
NO ====================================================================================


Candidate:
Admin-240 2R Page 4 of 9 Tools/Equipment/Procedures Needed:
_______________________________________
Time Start: __
_______    NAME      Time Finish: ________
Performance Rating:
SAT ______ UNSAT ______
Performance Time
: _________
Examiner: ______________________________          ____________________________________/________
NAME      SIGNATURE                            DATE
====================================================================================
COMMENTS Admin-240 2R Page 3 of 9 SIMULATOR OPERATOR INSTRUCTIONS NONE Admin-240 2R Page 4 of 9 Tools/Equipment/Procedures Needed:
OP/1/A/1105/014 (Control Room Instrumentation Operation And Information)
OP/1/A/1105/014 (Control Room Instrumentation Operation And Information)
OAC Screen capture image for SG information READ TO OPERATOR DIRECTION TO TRAINEE:
OAC Screen capture image for SG information READ TO OPERATOR DIRECTION TO TRAINEE:
I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
INITIAL CONDITIONS:
INITIAL CONDITIONS:
Reactor power =
Reactor power = 75%
75%
OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl. 4.1 (Mode 1 & 2) in progress.
OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl.
4.1 (Mode 1 & 2) in progress.
 
INITIATING CUES:
INITIATING CUES:
CR SRO directs you to perform OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl.
CR SRO directs you to perform OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl. 4.1 (Mode 1 & 2) on page 6 of 15 component check for the 1A SG Downcomer Temperature.
4.1 (Mode 1 & 2) on page 6 of 15 component check for the 1A SG Downcomer Temperature.


Admin-240 2R Page 5 of 9   START TIME: _______
Admin-240 2R Page 5 of 9 START TIME: _______
STEP 1: Enclosure 4.1 (page 6 of 15)
STEP 1:     Enclosure 4.1 (page 6 of 15)                                         CRITICAL STEP Verify All SG Downcomer Temperature computer points agree within 3°F of each other.
Verify All SG Downcomer Temperature computer points agree within 3°F of each other.
___ SAT IF All SG Downcomer Temperatures DO NOT agree within 3°F of each other, then perform Enclosure "Channel Check Of OTSG Downcomer Temperatures".
IF All SG Downcomer Temperatures DO NOT agree within 3°F of each other, then perform Enclosure "Channel Check Of OTSG Downcomer Temperatures".
___ UNSAT O1E2008 - 528.87°F O1E2009 - 538.97°F O1E2012 - 532.78°F O1E2013 - 533.65°F STANDARD:   Determine that the above OAC points do NOT agree within 3°F of each other, and perform Enclosure 4.19 "Channel Check of OTSG Downcomer Temperatures".
O1E2008 - 5 28.8 7°F O1E2009 - 53 8.97°F O1E2012 - 532.78°F O1E2013 - 53 3.65°F STANDARD: Determine that the above OAC point s do NOT agree within 3°F of each other, and perform Enclosure 4.19 "Channel Check of OTSG Downcomer Temperatures".
COMMENTS:
STEP 2:    Step 3.1 (Enclosure 4.19)
Determine saturation temperature for 1A OTSG based on power level and 1A OTSG outlet pressure as follows:
___ SAT Step 3.1.1 Determine 1A OTSG outlet pressure using any one of the following computer points:
___ UNSAT
* O1E2281 - 888.5 psig
* O1E2283 - 888.5 psig
* O1E2031 - 888.5 psig
* O1E2032 - 888.5 psig STANDARD:  Using the OAC determine that 1A OTSG pressure is 888.5.
COMMENTS:
COMMENTS:
CRITICAL STEP


___ SAT 
Admin-240 2R Page 6 of 9 STEP 3:   Step 3.1.2                                                            CRITICAL STEP Using table in Section 4, determine the 1A OTSG saturation temperature based on power level and 1A OTSG Outlet Pressure obtained in step 3.1.1.
 
___ UNSAT  STEP 2: Step 3.1 (Enclosure 4.19) Determine saturation temperature for 1A OTSG based on power level and 1A OTSG outlet pressure as follows:
Step 3.1.1 Determine 1A OTSG outlet pressure using any one of the following computer points:  O1E2281 - 88 8.5 psig  O1E2283 - 88 8.5 psig  O1E2031 - 88 8.5 psig  O1E2032 - 88 8.5 psig  STANDARD: Using the OAC determine that 1A OTSG pressure is 888.5. COMMENTS:
___ SAT
___ SAT
___ UNSAT Admin-240 2R Page 6 of 9  STEP 3: Step 3.1.2 Using table in Section 4, determine the 1A OTSG saturation temperature based on power level and 1A OTSG Outlet Pressure obtained in step 3.1.1. ____________ 1A OTSG saturation temperature STANDARD: Determine that 1A OTSG saturation temperature is  53 3.9ºF (533.8 - 534.0) by using the table in section 4.
____________ 1A OTSG saturation temperature STANDARD: Determine that 1A OTSG saturation temperature is  533.9ºF (533.8 -      ___ UNSAT 534.0) by using the table in section 4.
COMMENTS:  
COMMENTS:
STEP 4:   Step 3.1.3                                                            CRITICAL STEP Compare O1E2008 SG Lower Downcomer Temperature Loop A to the 1A OTSG saturation temperature determined in step 3.1.2:
___ SAT Step 3.1.4 IF O1E2008 SG Lower Downcomer Temperature Loop A is NOT within
          +/- 4.9 °F of the 1A OTSG saturation temperature, then enter Condition A of SLC 16.7.5 for OTSG overfill protection system inoperable.            ___ UNSAT STANDARD: Determine that O1E2008 SG Lower Downcomer Temperature Loop A (528.87°F) is NOT within +/- 4.9 °F of the 1A OTSG saturation temperature (533.9°F), and entry Condition A of SLC 16.7.5 for OTSG overfill protection system inoperable is required.
COMMENTS:


CRITICAL STEP
Admin-240 2R Page 7 of 9 STEP 5:      Step 3.1.5                                                            CRITICAL STEP Compare O1E2009 SG Lower Downcomer Temperature Loop A to the 1A OTSG saturation temperature determined in step 3.1.2:
___ SAT Step 3.1.6 IF O1E2009 SG Lower Downcomer Temperature Loop A is NOT within
              +/- 4.9 °F of the 1A OTSG saturation temperature, then enter Condition A of SLC 16.7.5 for OTSG overfill protection system inoperable.            ___ UNSAT STANDARD:    Determine that O1E2009 SG Lower Downcomer Temperature Loop A (538.97) is NOT within +/- 4.9 °F of the 1A OTSG saturation temperature (533.9°), and entry Condition A of SLC 16.7.5 for OTSG overfill protection system inoperable is required.
Cue: Inform the candidate that another operator will complete this procedure.
COMMENTS:
END TASK STOP TIME: ____________


___ SAT 
Admin-237 Page 8 of 9 CRITICAL STEP EXPLANATIONS:
STEP #                                        Explanation 1    Step is required to complete the surveillance.
3    Step is required to complete the surveillance.
4    Determining that the computer points in both Step 4 and Step 5 are out of the allowable band is critical to ensure that SLC 16.7.5 Condition A is not exited prior to BOTH computer points being repaired.
5    Determining that the computer points in both Step 4 and Step 5 are out of the allowable band is critical to ensure that SLC 16.7.5 Condition A is not exited prior to BOTH computer points being repaired.


___ UNSAT  STEP 4:  Step 3.1.3 Compare O1E2008 SG Lower Downcomer Temperature Loop A to the 1A OTSG saturation temperature determined in step 3.1.2:
2R CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
Step 3.1.4 IF O1E2008 SG Lower Downcomer Temperature Loop A is NOT within +/- 4.9 °F of the 1A OTSG saturation temperature, then enter Condition A of SLC 16.7.5 for OTSG overfill protection system inoperable.
INITIAL CONDITIONS:
STANDARD: Determine that O1E2008 SG Lower Downcomer Temperature Loop A (528.87°F) is NOT within +/- 4.9 °F of the 1A OTSG saturation temperature (533.9°F), and entry Condition A of SLC 16.7.5 for OTSG overfill protection system inoperable is required
Reactor power = 75%
. COMMENTS:
OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl. 4.1 (Mode 1 &
CRITICAL STEP
: 2) in progress.
___ SAT        ___ UNSAT Admin-240 2R Page 7 of 9  STEP 5:  Step 3.1.5 Compare O1E2009 SG Lower Downcomer Temperature Loop A to the 1A OTSG saturation temperature determined in step 3.1.2:
INITIATING CUES:
Step 3.1.6 IF O1E2009 SG Lower Downcomer Temperature Loop A is NOT within +/- 4.9 °F of the 1A OTSG saturation temperature, then enter Condition A of SLC 16.7.5 for OTSG overfill protection system inoperable.
CR SRO directs you to perform OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl. 4.1 (Mode 1 & 2) on page 6 of 15 component check for the 1A SG Downcomer Temperature.
STANDARD: Determine that O1E2009 SG Lower Downcomer Temperature Loop A (538.97) is NOT within +/- 4.9 °F of the 1A OTSG saturation temperature (533.9°), and entry Condition A of SLC 16.7.5 for OTSG overfill protection system inoperable is required
.
Cue: Inform the candidate that another operator will complete this procedure
. COMMENTS:      END TASK  CRITICAL STEP


___ SAT 
ADMIN-241 2S Page 1 of 9 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE ADMIN-241 Complete a Surveillance Evaluation (SRO ONLY)
CANDIDATE EXAMINER


___ UNSAT  STOP TIME: ____________
ADMIN-241 2S Page 2 of 9 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:
Complete PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.12 (Surveillance Evaluation)
Alternate Path:
N/A Facility JPM #:
New K/A Rating(s):
System:    Gen K/A:      2.2.12 Rating:    3.7/4.1 Task Standard:
Complete PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.12 (Surveillance Evaluation)
Preferred Evaluation Location:                                          Preferred Evaluation Method:
Simulator __ ___ In-Plant ___ ___ Classroom __ X___                      Perform __ X__ Simulate_    __


Admin-237 Page 8 of 9  CRITICAL STEP EXPLANATIONS:
==References:==
STEP # Explanation 1 Step is required to complete the surveillance.
3 Step is required to complete the surveillance.
4 Determining that the computer points in both Step 4 and Step 5 are out of the allowable band is critical to ensure that SLC 16.7.5 Condition A is not exited prior to BOTH computer points being repaired.
5 Determining that the computer points in both Step 4 and Step 5 are out of the allowable band is critical to ensure that SLC 16.7.5 Condition A is not exited prior to BOTH computer points being repaired.


2R  CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) page 25 of 26 PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.9 (RCP Power Supply Verification)
INITIAL CONDITIONS:
PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.12 (Surveillance Evaluation)
Reactor power =
Validation Time: 20 min.                                                Time Critical: No
75%  OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl.
=====================================================================================
4.1 (Mode 1 & 2) in progress.
Candidate:      _______________________________________                                Time Start: _________
 
NAME                                                    Time Finish: ________
INITIATING CUES:
Performance Rating: SAT ______ UNSAT ______                                      Performance Time: _________
CR SRO directs you to perform OP/1/A/1105/014 (Control Room Instrumentation Operation And
Examiner: ______________________________              ___________________________________/_________
NAME                                              SIGNATURE                    DATE
=====================================================================================
Comments


Information) Encl.
ADMIN-241 2S Page 3 of 9 SIMULATOR OPERATOR INSTRUCTIONS NONE
4.1 (Mode 1 & 2) on page 6 of 15 component check for the 1A SG Downcomer Temperature.


ADM IN-241 2S  Page 1 of 9      REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE
ADMIN-241 2S Page 4 of 9 Tools/Equipment/Procedures Needed:
 
PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) page 25 of 26 PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.9 (RCP Power Supply Verification)
ADMIN-241  Complete a Surveillance Evaluation (SRO ONLY)
CANDIDATE    EXAMINER ADM IN-241 2S   Page 2 of 9  REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:  Complete PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.12 (Surveillance Evaluation)
Alternate Path
:
N/A          Facility JPM #
:  New K/A Rating(s)
:    System:    G en K/A:    2.2.12 Rating:      3.7/4.1  Task Standard
:
Complete PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.12 (Surveillance Evaluation)
Preferred Evaluation Location
:    Preferred Evaluation Method
:  Simulator
__  ___ In-Plant ___  ___ Classroom __ X___  Perform __ X__ Simulate_    __  References
:
PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) page 2 5 of 2 6 PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.9 (RCP Power Supply Verification)
PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.12 (Surveillance Evaluation)
Validation Time
: 20 min.      Time Critical
:  No ===================================================================================
==              Candidate:
_______________________________________
Time Start: ____
_____    NAME      Time Finish: ________
Performance Rating:
SAT ______ UNSAT ______
Performance Time
: _________
Examiner: ______________________________          ___________________________________/____
_____    NAME      SIGNATURE DATE =================================================================================
==== Comments ADM IN-241 2S  Page 3 of 9 SIMULATOR OPERATOR INSTRUCTIONS NONE ADM IN-241 2S  Page 4 of 9  Tools/Equipment/Procedures Needed
: PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) page 2 5 of 2 6 PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.
9 (RCP Power Supply Verification)
PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.12 (Surveillance Evaluation)
PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.12 (Surveillance Evaluation)
Surveillance Frequency List READ TO OPERATOR DIRECTIONS TO STUDENT I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
Surveillance Frequency List READ TO OPERATOR DIRECTIONS TO STUDENT I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
INITIAL CONDITIONS:
INITIAL CONDITIONS:
Time/Date =
Time/Date = 0830 on Saturday, June 8.
0830 on Saturday, June 8. RCS Temperature = 298  
RCS Temperature = 298 °F.
°F. 1/0 RCP operation in progress (1A1 RCP in operation).
1/0 RCP operation in progress (1A1 RCP in operation).
PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) in progress. SR 3.4.5.2 on page 25 of 26 of PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) is being performed.
PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) in progress.
SR 3.4.5.2 on page 25 of 26 of PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) is being performed.
Step 2.2 of Encl. 13.9 (RCP Power Supply Verification) is determined to NOT be satisfied because neither the 1B1 nor the 1B2 RCP has power available.
Step 2.2 of Encl. 13.9 (RCP Power Supply Verification) is determined to NOT be satisfied because neither the 1B1 nor the 1B2 RCP has power available.
INITIATING CUE:
INITIATING CUE:
Based on the above conditions, complete PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.12 (Surveillance Evaluation)
Based on the above conditions, complete PT/1/A/0600/001 (Periodic Instrument Surveillance)
Encl. 13.12 (Surveillance Evaluation)


ADM IN-241 2S   Page 5 of 9 START TIME: _______           STEP 1: Surveillance
ADMIN-241 2S Page 5 of 9 START TIME: _______
STEP 1:       Surveillance


== Description:==
== Description:==


STANDARD: Documents that this is a Tech Spec required verification of correct RCP breaker alignment of power available to the required pump this is not in operation     COMMENTS:             ___ SAT
STANDARD:     Documents that this is a Tech Spec required verification of correct RCP   ___ SAT breaker alignment of power available to the required pump this is not in operation
___ UNSAT  STEP 2: Applicable TS(s)/SLC(s)/Site Directive(s), etc.:
___ UNSAT COMMENTS:
STANDARD: Determines that Tech Spec 3.4.5 (RCS Loops Mode 3) is applicable and documents in Step 2 COMMENTS:       CRITICAL STEP
STEP 2:       Applicable TS(s)/SLC(s)/Site Directive(s), etc.:                         CRITICAL STEP STANDARD:     Determines that Tech Spec 3.4.5 (RCS Loops Mode 3) is applicable and documents in Step 2                                                   ___ SAT COMMENTS:
___ SAT        ___ UNSAT   STEP 3: Description of discrepancy/deficiency:
___ UNSAT STEP 3:       Description of discrepancy/deficiency:
STANDARD: Documents that the required RCP Breaker alignment does not exist.
STANDARD:     Documents that the required RCP Breaker alignment does not exist.         ___ SAT NOTE: TS 3.4.5 requires that either the 1B1 or 1B2 have power available
NOTE: TS 3.4.5 requires that either the 1B1 or 1B2 have power available COMMENTS:               ___ SAT
___ UNSAT COMMENTS:
___ UNSAT  STEP 4: Is surveillance applicable for present plant condit ions? STANDARD: Marks "yes" COMMENTS:
STEP 4:       Is surveillance applicable for present plant conditions?                 CRITICAL STEP STANDARD:     Marks yes
CRITICAL STEP
___ SAT COMMENTS:
 
___ UNSAT
___ SAT
 
___ UNSAT ADM IN-241 2S  Page 6 of 9  STEP 5: If surveillance is applicable, what is the latest due date for surveillance OR applicable LCO?
STANDARD: Documents that the latest due date is 0830 on Tuesday , June 11 (72 hours from discovery) per Condition A of TS 3.4.5 COMMENTS:
CRITICAL STEP
 
___ SAT
___ UNSAT STEP 6: Is applicable TS(s)/SLC(s)/Site Directive(s), etc. satisfied with existing discrepancy/deficiency?
STANDARD:  *Marks "no" Explains in justification that TS 3.4.5 requires both RCS loops be Operable and with no power available to the 1B1 and 1B2 RCP's, the B RCS loop is NOT operable COMMENTS:      *CRITICAL STEP


___ SAT       ___ UNSAT    STEP 7: Support personnel/groups contacted (if any) AND information provided:
ADMIN-241 2S Page 6 of 9 STEP 5:  If surveillance is applicable, what is the latest due date for surveillance CRITICAL STEP OR applicable LCO?
STANDARD: Candidate may indicate requesting SPOC assistance to determine why neither of the required RCP breakers are racked in however since there is no indication of mechanical failures it would not be required.
STANDARD: Documents that the latest due date is 0830 on Tuesday, June 11 (72            ___ SAT hours from discovery) per Condition A of TS 3.4.5 COMMENTS:
___ UNSAT STEP 6:  Is applicable TS(s)/SLC(s)/Site Directive(s), etc. satisfied with existing  *CRITICAL STEP discrepancy/deficiency?
STANDARD:                                                                              ___ SAT
          *   *Marks no
* Explains in justification that TS 3.4.5 requires both RCS loops be Operable and with no power available to the 1B1 and 1B2 RCPs, the B RCS loop is NOT operable                                          ___ UNSAT COMMENTS:
STEP 7:   Support personnel/groups contacted (if any) AND information provided:
STANDARD: Candidate may indicate requesting SPOC assistance to determine why           ___ SAT neither of the required RCP breakers are racked in however since there is no indication of mechanical failures it would not be required.
___ UNSAT COMMENTS:


COMMENTS:
ADMIN-241 2S Page 7 of 9 STEP 8:   Describe corrective/compensatory actions being taken (procedure change, WR, PIP, etc.), and resolution date for those actions.             ___ SAT STANDARD:
___ SAT        ___ UNSAT ADM IN-241 2S   Page 7 of 9   STEP 8: Describe corrective/compensatory actions being taken (procedure change, WR, PIP, etc.), and resolution date for those actions.
          *Corrective/Compensatory Action:                                           ___ UNSAT Candidate should indicate that actions will commence to establish the required breaker alignment. This could be by issuing a Work Request, writing a PIP, or dispatching personnel to determine why the breakers are open and if the breakers could be racked in.
STANDARD: *Corrective/Compensatory Action:
Candidate should indicate that actions will commence to establish the required breaker alignment. This could be by issuing a Work Request, writing a PIP, or dispatching personnel to determine why the breakers are open and if the breakers could be racked in.
Resolution Date:
Resolution Date:
This blank may be left open at this time since the investigation is just beginning however in no case should a date and time that would result in exceeding the 72 hour completion time be entered.
This blank may be left open at this time since the investigation is just beginning however in no case should a date and time that would result in exceeding the 72 hour completion time be entered.
COMMENTS:
COMMENTS:
___ SAT        ___ UNSAT    STEP 9: Approval:   STANDARD: Signs and Dates either of the blanks provided COMMENTS:     END OF TASK
STEP 9:   Approval:
___ SAT 
STANDARD: Signs and Dates either of the blanks provided                             ___ SAT COMMENTS:
___ UNSAT END OF TASK


___ UNSAT ADM IN-241 2S   Page 8 of 9 CRITICAL STEP EXPLANATIONS STEP # Explanation 2 Required to determine the applicable Tech Spec 4 Required to determine if this Tech Spec is applicable in Mode 3 5 Incorrect documentation could lead to exceeding allowed time to complete Tech Spec Required Actions.
ADMIN-241 2S Page 8 of 9 CRITICAL STEP EXPLANATIONS STEP #                                     Explanation 2   Required to determine the applicable Tech Spec 4   Required to determine if this Tech Spec is applicable in Mode 3 5   Incorrect documentation could lead to exceeding allowed time to complete Tech Spec Required Actions.
6 Required to determine if the LCO is met
6   Required to determine if the LCO is met


2S   CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
2S CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
INITIAL CONDITIONS:
INITIAL CONDITIONS:
Time/Date = 0830 on Saturday, June 8. RCS Temperature = 298  
Time/Date = 0830 on Saturday, June 8.
°F. 1/0 RCP operation in progress (1A1 RCP in operation).
RCS Temperature = 298 °F.
1/0 RCP operation in progress (1A1 RCP in operation).
PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) in progress.
PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) in progress.
SR 3.4.5.2 on page 25 of 26 of PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) is being performed.
SR 3.4.5.2 on page 25 of 26 of PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) is being performed.
Step 2.2 of Encl. 13.9 (RCP Power Supply Verification) is determined to NOT be satisfie d because neither the 1B1 nor the 1B2 RCP has power available.
Step 2.2 of Encl. 13.9 (RCP Power Supply Verification) is determined to NOT be satisfied because neither the 1B1 nor the 1B2 RCP has power available.
INITIATING CUE:
INITIATING CUE:
Based on the above conditions, complete PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.12 (Surveillance Evaluation)
Based on the above conditions, complete PT/1/A/0600/001 (Periodic Instrument Surveillance)
Encl. 13.12 (Surveillance Evaluation)


Admin-30 6 3B Page 1 of 8 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE
Admin-306 3B Page 1 of 8 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Admin-306 Calculate the Maximum Permissible Stay Time Within Emergency Dose Limits (EDL)
CANDIDATE EXAMINER


Admin-30 6  Calculate the Maximum Permissible Stay Time Within Emergency Dose Limits (EDL)
Admin-306 3B Page 2 of 8 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:
CANDIDATE      EXAMINER Admin-30 6 3B Page 2 of 8 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task: Calculate the Maximum Permissible Stay Time Within the Emergency Dose Limits. Alternate Path
Calculate the Maximum Permissible Stay Time Within the Emergency Dose Limits.
N/A Facility JPM #
Alternate Path:
:
N/A Facility JPM #:
Admin 305 K/A Rating(s)
Admin 305 K/A Rating(s):
System: Gen K/A:   2.3.4 Rating:   3.2/3.7 Task Standard
System: Gen K/A:     2.3.4 Rating: 3.2/3.7 Task Standard:
Calculate the Maximum Permissible Stay Time Within the Emergency Dose Limits.
Calculate the Maximum Permissible Stay Time Within the Emergency Dose Limits.
Preferred Evaluation Location:                                    Preferred Evaluation Method:
Simulator _____ In-Plant ______ Classroom _ _X_                    Perform __X__ Simulate _____


Preferred Evaluation Location
==References:==
:    Preferred Evaluation Method
:  Simulator _____ In-Plant ______ Classroom _ _X_      Perform __X__ Simulate _____  References
:
NSD-507 (Radiation Protection
)  OMP 1-18 (Implementation Standard During Abnormal And Emergency Events
)  Validation Time
: 20 min.      Time Critical
:  N o =====================================================================================
Candidate: _______________________________________
Time Start: _____
____    NAME      Time Finish: ________
Performance Rating
:  SAT ______ UNSAT ______
Performance Time __
_______
Examiner: ______________________________          ____________________________________/___
______    NAME      SIGNATURE                            DATE
=====================================================================================
= COMMENTS Admin-30 6 3B Page 3 of 8 SIMULATOR OPERATOR INSTRUCTIONS NONE Admin-30 6 3B Page 4 of 8 Tools/Equipment/Procedures Needed
:  Calculator Note tablet READ TO OPERATOR DIRECTIONS TO STUDENT I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.


INITIAL CONDITIONS Steam Generator Tube Rupture has occurred on Unit 3 Emergency Dose Limits are in effect NEO "A" has received 1.26 R em TEDE this year The following tasks are required to be performed:
NSD-507 (Radiation Protection)
0B# 1BTASK 2BTIME REQUIRED 3BDOSE RATE 4B 1 5BClose 3C-573    6B11 min 7B6.15 R/hr 8B 2 9BOpen 3FDW-313 10B6 min 11B18.25 R/hr 12B 3 13BOpen all Unit 3's ADVs 14B4.65 R/hr  Note:  Assume no dose is received while traveling between tasks.
OMP 1-18 (Implementation Standard During Abnormal And Emergency Events)
Validation Time: 20 min.                                           Time Critical: No
=====================================================================================
Candidate:      _______________________________________                            Time Start: _________
NAME                                                Time Finish: ________
Performance Rating: SAT ______ UNSAT ______                                Performance Time _________
Examiner: ______________________________            ____________________________________/_________
NAME                                        SIGNATURE                    DATE
=====================================================================================
=
COMMENTS


INITIATING CUE Refer to the above information. NEO "A" has completed tasks 1 and 2 in the time required.
Admin-306 3B Page 3 of 8 SIMULATOR OPERATOR INSTRUCTIONS NONE


Admin-306 3B Page 4 of 8 Tools/Equipment/Procedures Needed:
Calculator Note tablet READ TO OPERATOR DIRECTIONS TO STUDENT I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
INITIAL CONDITIONS Steam Generator Tube Rupture has occurred on Unit 3 Emergency Dose Limits are in effect NEO A has received 1.26 Rem TEDE this year The following tasks are required to be performed:
0B                          TASK 1B            TIME REQUIRED 2B                    DOSE RATE 3B 1
4B        Close 3C-573 5B                                11 min 6B                      6.15 R/hr 7B 2
8B        Open 3FDW-313 9B                                6 min 10B              18.25 R/hr 1B 3
12B      Open all Unit 3s ADVs 13B                                                    4.65 R/hr 14B Note: Assume no dose is received while traveling between tasks.
INITIATING CUE Refer to the above information. NEO A has completed tasks 1 and 2 in the time required.
Determine how long the NEO has to complete task 3 without exceeding his/her Emergency Dose Limits.
Determine how long the NEO has to complete task 3 without exceeding his/her Emergency Dose Limits.
Admin-30 6 3B Page 5 of 8  START TIME: _______
Examiner Note:    Candidate may perform these steps in a different order
; however , the calculated stay time must be correct. EDL is 5 R em per event (LOCA or SGTR).
Current exposure for the year is not counted toward the Emergency Dose Limit s (EDL). STEP 1: Determine dose received while performing task 1.
STANDARD: Determine dose received while performing task 1.
6.15 R/hr X 1hr/60 min X 11 min = 1.1275 R (1.12 to 1.13 R)
COMMENTS:        CRITICAL STEP
___ SAT        ___ UNSAT  STEP 2: Determine dose received while performing task 2.


STANDARD: Determine dose received while performing task 2.
Admin-306 3B Page 5 of 8 START TIME: _______
18.2 5 R/hr X 1hr/60 min X 6 min = 1.8 25 R   (1.82 to 1.83 R)
Examiner Note:
COMMENTS:           CRITICAL STEP
* Candidate may perform these steps in a different order; however, the calculated stay time must be correct.
 
* EDL is 5 Rem per event (LOCA or SGTR).
___ SAT       ___ UNSAT  STEP 3: Determine dose remaining from EDLs.
* Current exposure for the year is not counted toward the Emergency Dose Limits (EDL).
STEP 1:        Determine dose received while performing task 1.                        CRITICAL STEP STANDARD:      Determine dose received while performing task 1.                        ___ SAT 6.15 R/hr X 1hr/60 min X 11 min = 1.1275 R (1.12 to 1.13 R)                                                        ___ UNSAT COMMENTS:
STEP 2:        Determine dose received while performing task 2.                        CRITICAL STEP
___ SAT STANDARD:     Determine dose received while performing task 2.
18.25 R/hr X 1hr/60 min X 6 min = 1.825 R
___ UNSAT (1.82 to 1.83 R)
COMMENTS:
STEP 3:        Determine dose remaining from EDLs.                                      CRITICAL STEP
___ SAT STANDARD:     Determine dose remaining from EDLs.
5R - 1.1275R - 1.825R = 2.0475 R
___ UNSAT (2.04 to 2.06 R)
COMMENTS:


STANDARD: Determine dose remaining from EDLs.
Admin-306 3B Page 6 of 8 STEP 4:     Determine time available for the NEO to complete task 3 without    CRITICAL STEP exceeding EDL.
5R - 1.1275 R - 1.8 25R = 2.04 75 R   (2.04 to 2.06 R)
___ SAT STANDARD:  Stay time is calculated to be:
Available Dose =    2.0475 R   = .44 hr X 60 min = 26.42 min Dose Rate          4.65 R/hr            1hr                      ___ UNSAT (26 to 27 Minutes)
COMMENTS:
COMMENTS:
CRITICAL STEP
END OF TASK STOP TIME: ________
___ SAT        ___ UNSAT Admin-30 6 3B Page 6 of 8  STEP 4: Determine time available for the NEO to complete task 3 without exceeding EDL
. STANDARD: Stay time is calculated to be:
Available Dose
  =  2.04 75 R    = .44 hr X 60 min = 26.4 2 min      Dose Rate 4.65 R/hr      1hr        (26 to 27 Minutes
)  COMMENTS:      END OF TASK CRITICAL STEP
___ SAT
___ UNSAT  STOP TIME: ________


Admin-30 6 3B Page 7 of 8 CRITICAL STEP EXPLANATIONS STEP # Explanation 1 Required to calculate stay time. 2 Required to calculate stay time.
Admin-306 3B Page 7 of 8 CRITICAL STEP EXPLANATIONS STEP #                                 Explanation 1   Required to calculate stay time.
3 Required to calculate stay time.
2   Required to calculate stay time.
4 Required to calculate stay time.
3   Required to calculate stay time.
4   Required to calculate stay time.


3B   CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
3B CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
INITIAL CONDITIONS Steam Generator Tube Rupture has occurred on Unit 3 Emergency Dose Limits are in effect NEO "A" has received 1.26 R em TEDE this year The following tasks are required to be performed:
INITIAL CONDITIONS Steam Generator Tube Rupture has occurred on Unit 3 Emergency Dose Limits are in effect NEO A has received 1.26 Rem TEDE this year The following tasks are required to be performed:
15B# 16BTASK 17BTIME REQUIRED 18BDOSE RATE 19B 1 20BClose 3C-573   21B11 min 22B6.15 R/hr 23B 2 24BOpen 3FDW-313 25B6 min 26B18.25 R/hr 27B 3 28BOpen all Unit 3's ADVs 29B4.65 R/hr Note: Assume no dose is received while traveling between tasks.
15B                               TASK 16B              TIME REQUIRED 17B              DOSE RATE 18B 1
19B         Close 3C-573 20B                                    11 min 21B                  6.15 R/hr 2B 2
23B         Open 3FDW-313 24B                                    6 min 25B          18.25 R/hr 26B 3
27B         Open all Unit 3s ADVs 28B                                                    4.65 R/hr 29B Note: Assume no dose is received while traveling between tasks.
INITIATING CUE Refer to the above information. NEO A has completed tasks 1 and 2 in the time required.
Determine how long the NEO has to complete task 3 without exceeding his/her Emergency Dose Limits.


INITIATING CUE Refer to the above information. NEO "A" has completed tasks 1 and 2 in the time required.
ADMIN-412 4S Page 1 of 11 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE ADMIN-412 Determine Emergency Classification and complete the initial Emergency Notification form (SRO Only)
CANDIDATE EXAMINER


Determine how long the NEO has to complete task 3 without exceeding his/her Emergency Dose Limits.  
ADMIN-412 4S Page 2 of 11 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:
Determine Emergency Classification and complete the initial Emergency Notification form Alternate Path:
N/A Facility JPM #:
N/A K/A Rating(s):
System:      Gen K/A:        2.4.38 Rating:      2.4/4.4 Task Standard:
Appropriate classification is determined and associated Emergency Notification Form is completed with the time critical criteria.
Preferred Evaluation Location:                                          Preferred Evaluation Method:
Simulator __ ___ In-Plant ___ ___ Classroom __ X___                    Perform __ X__ Simulate_    __


ADM IN-412 4S    Page 1 of 11      REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE
==References:==


ADMIN-4 12  Determine Emergency Classification and complete the initial Emergency Notification form (SRO Only)
RP/0/B/1000/001 (Emergency Classification)
RP/0/B/1000/002 (Control Room Emergency Coordinator Procedure)
Nuclear Power Plant Emergency Notification Form 4.1.A.1 Validation Time: 20 min.                                                Time Critical: Yes
=====================================================================================
Candidate:          _______________________________________                            Time Start: _________
NAME                                                  Time Finish: ________
Performance Rating: SAT ______ UNSAT ______                                    Performance Time: _________
Examiner: ______________________________                ___________________________________/_________
NAME                                          SIGNATURE                      DATE
=====================================================================================
Comments


CANDIDATE    EXAMINER ADM IN-412 4S     Page 2 of 11   REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:  Determine Emergency Classification and complete the initial Emergency Notification form Alternate Path
ADMIN-412 4S Page 3 of 11 SIMULATOR OPERATOR INSTRUCTIONS NONE
:  N/A          Facility JPM #
: N/A  K/A Rating(s)
:    System:    G en K/A:    2.4.38 Rating:      2.4/4.4  Task Standard
:  Appropriate classification is determined and associated Emergency Notification Form is completed with the time critical criteria.
Preferred Evaluation Location
:    Preferred Evaluation Method
:  Simulator
__  ___ In-Plant ___  ___ Classroom __ X___  Perform __ X__ Simulate_    __  References
:
RP/0/B/1000/0 0 1 (Emergency Classification
) RP/0/B/1000/0 0 2 (Control Room Emergency Coordinator Procedure
) Nuclear Power Plant Emergency Notification Form 4.1.A.1  Validation Time
: 20 min.      Time Critical
:  Yes ===================================================================================
==
Candidate:
_______________________________________
Time Start: ____
_____    NAME      Time Finish: ________


Performance Rating:
ADMIN-412 4S Page 4 of 11 Tools/Equipment/Procedures Needed:
SAT ______ UNSAT ______
RP/0/B/1000/001 (Emergency Classification)
Performance Time
RP/0/B/1000/002 (Control Room Emergency Coordinator Procedure)
: _________
Examiner: ______________________________          ___________________________________/____
_____    NAME      SIGNATURE                            DATE
=================================================================================
==== Comments ADM IN-412 4S     Page 3 of 11  SIMULATOR OPERATOR INSTRUCTIONS NONE ADM IN-412 4S    Page 4 of 11 Tools/Equipment/Procedures Needed
: RP/0/B/1000/0 0 1 (Emergency Classification)
RP/0/B/1000/0 0 2 (Control Room Emergency Coordinator Procedure)
READ TO OPERATOR DIRECTIONS TO STUDENT I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
READ TO OPERATOR DIRECTIONS TO STUDENT I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.
INITIAL CONDITIONS:
INITIAL CONDITIONS:
0800 Unit 1 experiences a runback and trip due to a loss of Stator Coolant.
0800 Unit 1 experiences a runback and trip due to a loss of Stator Coolant.
0805 The Operator dispatched to determine if the MS Relief Valves have reseated reports that 1B SG appears to have two MSRVs damaged and still passing steam
0805 The Operator dispatched to determine if the MS Relief Valves have reseated reports that 1B SG appears to have two MSRVs damaged and still passing steam.
. 0806 1B SG has been isolated and RCS Temperature stabilized at 520F CETCs. 0815 Calculations indicate a 1A S/G Tube leak of 240 gpm is occurring
0806 1B SG has been isolated and RCS Temperature stabilized at 520°F CETCs.
. 1RIA-40 = 1,245 cps and increasing.
0815 Calculations indicate a 1A S/G Tube leak of 240 gpm is occurring. 1RIA-40 = 1,245 cps and increasing.
0816 The 1A S/G is being fed by the 1A MDEFWP and is being used for RCS Temperature control. Feeding the 1B S/G for Tube to Shell Delta Temperature concerns is NOT required at this time.
0816 The 1A S/G is being fed by the 1A MDEFWP and is being used for RCS Temperature control. Feeding the 1B S/G for Tube to Shell Delta Temperature concerns is NOT required at this time.
INITIATING CUE:
INITIATING CUE:
Perform the required actions of the Emergency Coordinator:
Perform the required actions of the Emergency Coordinator:
: 1. Determine Emergency Classification at Time = 0816 2. Complete appropriate Emergency Notification Form THIS IS A TIME CRITICAL JPM Note: Do not use Emergency Coordinator's judgment while classifying the event. When required, other operator s will maintain the Emergency Coordinator's Log and perform the duties of the Control Room Offsite Communicator.
: 1. Determine Emergency Classification at Time = 0816
: 2. Complete appropriate Emergency Notification Form THIS IS A TIME CRITICAL JPM Note: Do not use Emergency Coordinators judgment while classifying the event. When required, other operators will maintain the Emergency Coordinators Log and perform the duties of the Control Room Offsite Communicator.


ADM IN-412 4S     Page 5 of 11 START TIME: _______         (Actual time)
ADMIN-412 4S Page 5 of 11 START TIME: _______
STEP 1: Classify the Event STANDARD: Refer to RP/0/B/1000/01 (Emergency Classification) Enclosure 4.
(Actual time)
1 (Fission Product Barrier Matrix)
STEP 1:         Classify the Event                                                 CRITICAL STEP STANDARD:       Refer to RP/0/B/1000/01 (Emergency Classification) Enclosure 4.1 (Fission Product Barrier Matrix)                                   ___ SAT Classify as an ALERT due to:
Classify as an ALERT due to:
* RCS Barriers - 4 points due to SGTR >160 gpm
RCS Barriers - 4 points due to SGTR  
___ UNSAT Time of Classification: _________________
>160 gpm Time of Classification: _________________
Examiner Note: The criteria for getting 3 points for a SGTL in one S/G and the other S/G faulted is not met because the faulted S/G (1B) has been isolated.
Examiner Note: The criteria for getting 3 points for a SGTL in one S/G and the other S/G faulted is not met because the faulted S/G (1B) has been isolated.
COMMENTS:
COMMENTS:       CRITICAL STEP
STEP 2:         Commence the Off-Site Notification Form.
___ SAT 
STANDARD:       Go to RP/0/B/1000/002 (Control Room Emergency Coordinator           ___ SAT Procedure) and initiate procedure by determining symptoms for entry exist and check Step 1.1
 
___ UNSAT COMMENTS:
___ UNSAT  STEP 2: Commence the Off-Site Notification Form
STEP 3:          Step 2.1.
. STANDARD: Go to RP/0/B/1000/002 (Control Room Emergency Coordinator Procedure) and initiate procedure by determining symptoms for entry exist and check Step
STANDARD:        Determine step 2.1 does not apply                                  ___ SAT COMMENTS:
___ UNSAT


===1.1 COMMENTS===
ADMIN-412 4S Page 6 of 11 NOTE:
___ SAT
State and County agencies shall be notified within 15 minutes of E-plan declaration, Classification upgrades, and Protective Action Recommendations.
___ UNSAT  STEP 3: Step 2.1. STANDARD: Determine step 2.1 does not apply COMMENTS:              ___ SAT        ___ UNSAT ADM IN-412 4S     Page 6 of 11   NOTE: State and County agencies shall be notified within 15 minutes of E
___ SAT STEP 4:         Step 2.2 Declare the appropriate Emergency Classification level.
-plan declaration, Classification upgrades, and Protective Action Recommendations.
STEP 4: Step 2.2 Declare the appropriate Emergency Classification level.
Classification __ALERT_____ (UE, ALERT, SAE, GE)
Classification __ALERT_____ (UE, ALERT, SAE, GE)
Time Declared: _________
Time Declared: _________                                             ___ UNSAT STANDARD:       Declare an ALERT due to:
STANDARD: Declare an ALERT due to: 1A SGTR > 160 gpm ( 4 pts.) and the SG with an open path to the environment (1B SG) is NOT being fed by the affected unit nor does it contain a SG Tube Leak Time ALERT Declar ed documented in Step 1 (SAT is < Start Time + 15 minutes)
1A SGTR > 160 gpm ( 4 pts.) and the SG with an open path to the environment (1B SG) is NOT being fed by the affected unit nor does it contain a SG Tube Leak
* Time ALERT Declared documented in Step 1
                      *  (SAT is < Start Time + 15 minutes)
COMMENTS:
COMMENTS:
___ SAT        ___ UNSAT    STEP 5: Step 2.3 & 2.4 STANDARD: Determine Steps 2.3 and 2.4 do not apply COMMENTS:
STEP 5:         Step 2.3 & 2.4 STANDARD:       Determine Steps 2.3 and 2.4 do not apply                             ___ SAT COMMENTS:
___ SAT
___ UNSAT STEP 6:         Step 2.5 Appoint Control Room Offsite Communicator(s) and perform the following: N/A
___ UNSAT   STEP 6: Step 2.5 Appoint Control Room Offsite Communicator(s) and perform the following: N/A STANDARD: Any name (real or imaginary) is acceptable.
___ SAT STANDARD:       Any name (real or imaginary) is acceptable.
Note: Initiating Cue indicates these actions will be performed by another operator.
Note: Initiating Cue indicates these actions will be performed by another operator.
___ UNSAT COMMENTS:
ADMIN-412 4S Page 7 of 11 STEP 7:  Step 2.6 IAAT Changing plant conditions require an emergency classification upgrade,
___ SAT THEN Notify Offsite Communicator to complete the in-progress notifications per RP/0/B/1000/15A, (Offsite Communications From The CR)
AND Re-initiate a clean copy of this procedure for the upgraded
___ UNSAT classification and stop this procedure.
STANDARD: An Upgrade is not expected.
COMMENTS:
STEP 8:  Step 2.7                                                                  CRITICAL STEP Obtain the appropriate Offsite Notification form from the Emergency
___ SAT Plan cart.
STANDARD: Initial ALERT form # 4.1.A.1 is selected and candidate continues to fill-
___ UNSAT out form per the Step 2.7 substeps.
COMMENTS:
COMMENTS:
___ SAT        ___ UNSAT ADM IN-412 4S    Page 7 of 11  STEP 7: Step 2.6 IAAT Changing plant conditions require an emergency classification upgrade,  THEN Notify Offsite Communicator to complete the in
-progress notifications per RP/0/B/1000/15A, (Offsite Communications From The CR) AND Re-initiate a clean copy of this procedure for the upgraded classification and stop this procedure.
STANDARD: An Upgrade is not expected.


COMMENTS:  
ADMIN-412 4S Page 8 of 11 STEP 9:     Step 2.7 (continued)                                                        *CRITICAL STEP 2.7.1. Ensure EAL # as determined by RP/0/B/1000/001 matches Line 4.
 
(4.1.A.1) 2.7.2. Line 1 - Mark appropriate box "Drill" or "Actual Event" (DRILL) 2.7.3.  *Line 1 - Enter Message # (#1) 2.7.4.  *Line 2 - Mark Initial (INITIAL marked)                                      ___ SAT 2.7.5. *Line 6 - (Is Occurring marked)
___ SAT   
A. Mark "Is Occurring" if any of the following are true:
 
* RIAs 40, 45, or 46 are increasing or in alarm                ___ UNSAT
___ UNSAT   STEP 8: Step 2.7 Obtain the appropriate Offsite Notification form from the Emergency Plan cart.
* If containment is breached
STANDARD: Initial ALERT form # 4.1.A.1 is selected and candidate continues to fill
* Containment pressure > 1 psig B. Mark "None" if none of the above is applicable.
-out form per the Step 2.7 substeps.
2.7.6.  *Line 7 - If Line 6 Box B or C is marked, mark Box D. Otherwise mark Box A (D marked) 2.7.7.  *Line 8 - Mark "Stable" unless an upgrade or additional PARs are anticipated within an hour.
* Refer to Enclosure 4.9, (Event Prognosis Definitions) 2.7.8.  *Line 10 - Military time and date of declaration (Refer to date/time in Step 2.2) (Insert time from STEP 1 and todays date, military time is not critical as long as time is specific and accurate.)
2.7.9. Line 11 - If more than one unit affected, mark "All" (Unit 1 marked) 2.7.10. Line 12 - Mark affected unit(s) (reference Line 11) AND enter power level of affected unit(s) or time/date of shutdown (Unit 1 - 0% power, Shutdown at 0800 with todays date.)
2.7.11. Line 13 - If the OSM has no remarks, write "None" (indicate NONE) 2.7.12. If Condition "A" exists ensure following PARs are included Line 5.
A. Evacuate: Move residents living downstream of the Keowee Hydro Project dams to higher ground B. Other: Prohibit traffic flow across bridges identified on your inundation maps until the danger has passed. (Condition A does not exist. No PAR required)
STANDARD:  Correctly fills out Emergency Notification Form in accordance with Key.
COMMENTS:
COMMENTS:
CRITICAL STEP
___ SAT 


___ UNSAT ADM IN-412 4S     Page 8 of 11  STEP 9: Step 2.7 (continued) 2.7.1. Ensure EAL # as determined by RP/0/B/1000/001 matches Line 4. (4.1.A.1) 2.7.2. Line 1 - Mark appropriate box "Drill" or "Actual Event" (DRILL) 2.7.3. *Line 1 - Enter Message #
ADMIN-412 4S Page 9 of 11 STEP 10:     Step 2.7 (Continued)                                           CRITICAL STEP 2.7.13. Line 17 - OSM signature, CURRENT Time/Date (MUST SIGN)
(#1) 2.7.4. *Line 2 - Mark Initial (INITIAL marked) 2.7.5. *Line 6 - ('Is Occurring' marked)  A. Mark "Is Occurring" if any of the following are true:
STANDARD:     Indicate that OSM signature will be obtained on the completed Emergency Notification Form within 15 minutes of classification time recorded in step 1.
RIAs 40, 45, or 46 are increasing or in alarm If containment is breached Containment pressure
> 1 psig B. Mark "None" if none of the above is applicable.
2.7.6. *Line 7 - If Line 6 Box B or C is marked, mark Box D. Otherwise mark Box A ('D' mark ed) 2.7.7. *Line 8 - Mark "Stable" unless an upgrade or additional PARs are anticipated within an hour.
Refer to Enclosure 4.9, (Event Prognosis Definitions) 2.7.8. *Line 10 - Military time and date of declaration (Refer to date/time in Step 2.2)  (Inser t time from STEP 1 and today's date
, military time is not critical as long as time is specific and accurate.)
2.7.9. Line 11 - If more than one unit affected, mark "All" (Unit 1 marked) 2.7.10. Line 12 - Mark affected unit(s) (reference Line 11) AND enter power level of affected unit(s) or time/date of shutdown (Unit 1 - 0% power, Shutdown at 0800 with today's date.)
2.7.11. Line 13 - If the OSM has no remarks, write "None" (indicate NONE) 2.7.12. If Condition "A" exists ensure following PARs are included Line 5.
A. Evacuate: Move residents living downstream of the Keowee Hydro Project dams to higher ground B. Other: Prohibit traffic flow across bridges identified on your inundation maps until the danger has passed.
(Condition A does not exist. No PAR required)
STANDARD: Correctly fills out Emergency Notification Form in accordance with Key. COMMENTS:      *CRITICAL STEP
___ SAT    ___ UNSAT ADM IN-412 4S    Page 9 of 11  STEP 10: Step 2.7 (Continued) 2.7.13. Line 17 - OSM signature, CURRENT Time/Date (MUST SIGN)
STANDARD: Indicate that OSM signature will be obtained on the completed Emergency Notification Form within 15 minutes of classification time recorded in step 1.
STOP TIME #2: Time for Notification __________
STOP TIME #2: Time for Notification __________
(SAT is < Step 1 Time + 15 minutes)
(SAT is < Step 1 Time + 15 minutes)
COMMENTS:       END OF TASK CRITICAL STEP
COMMENTS:
END OF TASK


ADM IN-412 4S     Page 10 of 11 CRITICAL STEP EXPLANATIONS STEP # Explanation 1 The candidate needs to be able to utilize the procedure and determine the conditions meet a Site Area Emergency classification within 15 minutes
ADMIN-412 4S Page 10 of 11 CRITICAL STEP EXPLANATIONS STEP #                                       Explanation 1   The candidate needs to be able to utilize the procedure and determine the conditions meet a Site Area Emergency classification within 15 minutes.
. 8 The correct form that matches the EAL # is selected.
8   The correct form that matches the EAL # is selected.
9 The emergency notification form is filled-out with each line entry identified as 'critical' complete and accurate.
9   The emergency notification form is filled-out with each line entry identified as critical complete and accurate.
10 This is a time critical step. The Candidate needs to complete the notification form within 15 minutes from the time the EAL was declared. (Declaration time is the time recorded in JPM step 4)
10   This is a time critical step. The Candidate needs to complete the notification form within 15 minutes from the time the EAL was declared. (Declaration time is the time recorded in JPM step 4)


4S   CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
4S CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)
INITIAL CONDITIONS:
INITIAL CONDITIONS:
0800 Unit 1 experiences a runback and trip due to a loss of Stator Coolant.
0800 Unit 1 experiences a runback and trip due to a loss of Stator Coolant.
0805 The Operator dispatched to determine if the MS Relief Valves have reseated reports that 1B SG appears to have two MSRVs damaged and still passing steam
0805 The Operator dispatched to determine if the MS Relief Valves have reseated reports that 1B SG appears to have two MSRVs damaged and still passing steam.
. 0806 1B SG has been isolated and RCS Temperature stabilized at 520F CETCs. 0815 Calculations indicate a 1A S/G Tube leak of 240 gpm is occurring
0806 1B SG has been isolated and RCS Temperature stabilized at 520&deg;F CETCs.
. 1RIA-40 = 1,245 cps and increasing.
0815 Calculations indicate a 1A S/G Tube leak of 240 gpm is occurring. 1RIA-40 = 1,245 cps and increasing.
0816 The 1A S/G is being fed by the 1A MDEFWP and is being used for RCS Temperature control. Feeding the 1B S/G for Tube to Shell Delta Temperature concerns is NOT required at this time. INITIATING CUE:
0816 The 1A S/G is being fed by the 1A MDEFWP and is being used for RCS Temperature control. Feeding the 1B S/G for Tube to Shell Delta Temperature concerns is NOT required at this time.
INITIATING CUE:
Perform the required actions of the Emergency Coordinator:
Perform the required actions of the Emergency Coordinator:
: 1. Determine Emergency Classification at Time = 0816
: 1. Determine Emergency Classification at Time = 0816
: 2. Complete appropriate Emergency Notification Form THIS IS A TIME CRITICAL JPM Note: Do not use Emergency Coordinator's judgment while classifying the event. When required, other operator s will maintain the Emergency Coordinator's Log and perform the duties of the Control Room Offsite Communicator.}}
: 2. Complete appropriate Emergency Notification Form THIS IS A TIME CRITICAL JPM Note: Do not use Emergency Coordinators judgment while classifying the event. When required, other operators will maintain the Emergency Coordinators Log and perform the duties of the Control Room Offsite Communicator.}}

Latest revision as of 02:55, 6 February 2020

Initial Exam 2013-301 Final Administrative JPMs
ML13248A111
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 09/04/2013
From:
NRC/RGN-II
To:
Duke Energy Carolinas
References
50-269/13-301, 50-270/13-301, 50-287/13-301
Download: ML13248A111 (68)


Text

Admin-130 2.1S Page 1 of 12 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Admin-130 Perform Manual RCS Leakage Calculation and TS Determination (SRO Only)

CANDIDATE EXAMINER

Admin-130 2.1S Page 2 of 12 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:

Perform Manual RCS Leakage Calculation and TS Determination Alternate Path:

N/A Facility JPM #:

CRO-43 K/A Rating(s):

System: Gen K/A: 2.1.7 Rating: 4.4/4.7 Task Standard:

RCS Leakage is calculated per the attached key.

TS 3.4.13 Condition B entered.

Preferred Evaluation Location: Preferred Evaluation Method:

Simulator _____ In-Plant __ ___ Classroom __X___ Perform __X___ Simulate __ __

References:

PT/O/A/0600/001A (Loss Of Computer)

PT/1/A/0600/010 (Reactor Coolant Leakage)

TS 3.4.13 (RCS Operational LEAKAGE)

Validation Time: 18 minutes Time Critical: NO

=========================================================================

Candidate: _______________________________________ Time Start: ____________

NAME Time Finish: ___________

Performance Rating: SAT ______ UNSAT ______ Performance Time ___________

Examiner: ______________________________ ____________________________________/_________

NAME SIGNATURE DATE

=========================================================================

COMMENTS

Admin-130 2.1S Page 3 of 12 SIMULATOR OPERATOR INSTRUCTIONS NONE

Admin-130 2.1S Page 4 of 12 Tools/Equipment/Procedures Needed:

PT/1/A/0600/010 (Reactor Coolant Leakage) Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet)

Technical Specifications READ TO OPERATOR DIRECTION TO TRAINEE I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS Oconee Unit 1 computer repairs are expected to be extended through turnover for hardware replacement. The Loss of Computer procedure PT/O/A/0600/001A, Loss of Computer, is in progress; however an RCS Leakage Calculation has not been performed during this shift.

INITIATING CUES The OSM directs you to perform a manual RCS leakage calculation per PT/1A/0600/010 (Reactor Coolant Leakage) Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet) using the data collected below.

Evaluate leakage and determine if any Tech Spec Conditions that apply.

Manual RCS Leakage Data Parameter Initial Final Time 0015 0115 Pzr level 219.0 inches 219.5 inches Tave Indication 579.0°F 579.1°F Quench Tank Level 86.5 inches 86.5 inches LDST Level 76.7 inches 75.2 inches Power Range NI 100.0% 100.1%

RCS NR Pressure 2150 psig 2150 psig Group 7 Control Rod Position 92.7% 92.7%

Admin-130 2.1S Page 5 of 12 START TIME: _______

STEP 1: Step 2.1 Record Initial Data in "Table #1".

Value Initial Data Minus Final Data Equals Change PZR Level 219.0 inches - =

RCS Temp 579.0°F - =

QT Level 86.5 inches - = ____Sat LDST Level 76.7 inches - =

Rx Power 100.0% - =

RCS Press 2150 psig - = ____Unsat CR Pos 92.7% - =

STANDARD: Candidate enters initial set of data into Table #1 of Enclosure 13.3 (Manual Leakage Calculation Data Sheet) from the initiating cue.

COMMENTS STEP 2: Step 2.2 Record time Initial Data recorded: ____________

____Sat STANDARD: Candidate enters 0015 (from initiating cue)

COMMENTS ____Unsat

Admin-130 2.1S Page 6 of 12 STEP 3: Step 2.3 After 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, record Final Data in "Table #1".

Value Initial Data Minus Final Data Equal Change PZR Level 219.0 inches - 219.5 inches =

RCS Temp 579.0°F - 579.1°F =

QT Level 86.5 inches - 86.5 inches =

LDST Level 76.7 inches - 75.2 inches = ____Sat Rx Power 100.0% - 100.1% =

RCS Press 2150 psig - 2150 psig =

CR Pos 92.7% - 92.7% = ____Unsat STANDARD: Candidate enters final set of data into Table #1 of Enclosure 13.3 (Manual Leakage Calculation Data Sheet) (from initiating cue)

COMMENTS STEP 4: Step 2.4 Record time Final Data recorded: ____________

____Sat STANDARD: Candidate enters 0115 COMMENTS ____Unsat STEP 5: Step 2.5 CRITICAL STEP Record time elapsed time: ____________ minutes STANDARD: Candidate enters 60 minutes

____Sat COMMENTS

____Unsat

Admin-130 2.1S Page 7 of 12 STEP 6: Step 2.6 CRITICAL STEP Calculate and record "Change" values in "Table # 1"..

Value Initial Data Minus Final Data Equal Change PZR Level 219.0 inches - 219.5 inches = -.5 inches RCS Temp 579.0°F - 579.1°F = -.1°F ____Sat QT Level 86.5 inches - 86.5 inches = 0 inches LDST Level 76.7 inches - 75.2 inches = +1.5 inches Rx Power 100.0% - 100.1% = -.1% ____Unsat RCS Press 2150 psig - 2150 psig = 0 psig CR Pos 92.7% - 92.7% = 0%

STANDARD: Candidate calculates the change in data and fills in Table 1 change column.

COMMENTS STEP :7 Step 2.7 CRITICAL STEP Calculate Corrected Pzr Level Change:

STANDARD: -0.5 inches - (6.831 inches/°F X -.1°F) = +.1831 inches ____Sat

(+.18 to +.2)

____Unsat COMMENTS STEP :8 Step 2.8 CRITICAL STEP Convert Corrected Pzr Level Change to gallons STANDARD: +.1831 inches X 14.364 gallons / inch = +2.63 gallons

____Sat

(+.18 to +.2) ( 2.585 to 2.873)

COMMENTS ____Unsat

Admin-130 2.1S Page 8 of 12 STEP :9 Step 2.9 CRITICAL STEP Convert QT Level Change to gallons:

STANDARD: No change

____Sat COMMENTS

____Unsat STEP :10 Step 2.10 CRITICAL STEP Convert LDST Level Change to gallons STANDARD: +1.5 inches X 30.956 gallons / inch = +46.434 gallons

____Sat

(+46.4 to +46.5)

COMMENTS ____Unsat STEP :11 Step 2.11 CRITICAL STEP Calculate Total Volume Change STANDARD: 2.63 gallons + 0 gallons + 46.434 gallons = 49.064 gallons

____Sat

( 2.585 to 2.873) (+46.4 to +46.5) (48.98 to 49.37)

COMMENTS ____Unsat STEP :12 Step 2.12 CRITICAL STEP Calculate "RCS Unidentified Leakage Rate" STANDARD: 49.064 gallons / 60 minutes = .818 gpm

____Sat (48.98 to 49.37) (.816 to .823)

COMMENTS ____Unsat

Admin-130 2.1S Page 9 of 12 STEP :13 Refer to TS 3.4.13 RCS Operational LEAKAGE STANDARD: Candidate determines that the Tech Spec limit for Unidentified Leakage ____Sat is 1 gpm therefore entry into the Actions Table is NOT required.

____Unsat COMMENTS STEP :14 Refer to TS 3.4.13 RCS Operational LEAKAGE CRITICAL STEP EXAMINER CUE: Hand the candidate Cue sheet #2

____Sat STANDARD:

NOTE: After second cue sheet handed to candidate, he/she

____Unsat determines the leakage is pressure boundary leakage (see below)

Pressure Boundary: Determine that leakage exceeds the 0 gpm Pressure Boundary leakage limit and TS 3.4.13 Condition B applies. This required Mode 3 in 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and Mode 5 in 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />.

COMMENTS END TASK STOP TIME: ____________

Admin-130 2.1S Page 10 of 12 CRITICAL STEP EXPLANATIONS STEP # Explanation 5 Necessary data calculation to properly determine manual RCS leakage rate.

6 Necessary data calculation to properly determine manual RCS leakage rate.

7 Necessary data calculation to properly determine manual RCS leakage rate.

8 Necessary data calculation to properly determine manual RCS leakage rate.

9 Necessary data calculation to properly determine manual RCS leakage rate.

10 Necessary data calculation to properly determine manual RCS leakage rate.

11 Necessary data calculation to properly determine manual RCS leakage rate.

12 Necessary data calculation to properly determine manual RCS leakage rate.

13 Necessary to refer to correct TS and conclude limits are not exceeded.

14 Necessary to refer to correct TS and conclude limits are exceeded.

1.1S CANDIDATE CUE SHEET #1 (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS Oconee Unit 1 computer repairs are expected to be extended through turnover for hardware replacement. The Loss of Computer procedure PT/O/A/0600/001A, Loss of Computer, is in progress; however an RCS Leakage Calculation has not been performed during this shift.

INITIATING CUES The OSM directs you to perform a manual RCS leakage calculation per PT/1A/0600/010 (Reactor Coolant Leakage) Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet) using the data collected below.

Evaluate leakage and determine if any Tech Spec Conditions that apply.

Manual RCS Leakage Data Parameter Initial Final Time 0015 0115 Pzr level 219.0 inches 219.5 inches Tave Indication 579.0°F 579.1°F Quench Tank Level 86.5 inches 86.5 inches LDST Level 76.7 inches 75.2 inches Power Range NI 100.0% 100.1%

RCS NR Pressure 2150 psig 2150 psig Group 7 Control Rod Position 92.7% 92.7%

1.1S CANDIDATE CUE SHEET #2 (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIATING CUES Since completing the RCS Manual Leakage calculation, the RCS leak rate has increased to 2.17 gpm and the location of the leak has been determined to be the weld that connects the 1A1 HPI injection nozzle to the RCS piping.

Indicate below what (if any) Tech Spec Conditions, Required Actions, and Completion Times that apply.

Admin-131 1.1R Page 1 of 10 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Admin-131 Perform Manual RCS Leakage Calculation (RO Only)

CANDIDATE EXAMINER

Admin-131 1.1R Page 2 of 10 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:

Perform Manual RCS Leakage Calculation Alternate Path:

N/A Facility JPM #:

CRO-43 K/A Rating(s):

System: Gen K/A: 2.1.7 Rating: 4.4/4.7 Task Standard:

RCS Leakage is calculated per the attached key.

Preferred Evaluation Location: Preferred Evaluation Method:

Simulator _____ In-Plant __ ___ Classroom __X___ Perform __X___ Simulate __ __

References:

PT/O/A/0600/001A (Loss Of Computer)

PT/1/A/0600/010 (Reactor Coolant Leakage)

Validation Time: 18 minutes Time Critical: NO

=========================================================================

Candidate: _______________________________________ Time Start: ____________

NAME Time Finish: ___________

Performance Rating: SAT ______ UNSAT ______ Performance Time ___________

Examiner: ______________________________ ____________________________________/_________

NAME SIGNATURE DATE

=========================================================================

COMMENTS

Admin-131 1.1R Page 3 of 10 SIMULATOR OPERATOR INSTRUCTIONS NONE

Admin-131 1.1R Page 4 of 10 Tools/Equipment/Procedures Needed PT/1/A/0600/010 (Reactor Coolant Leakage) Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet)

READ TO OPERATOR DIRECTION TO TRAINEE I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS Oconee Unit 1 computer repairs are expected to be extended through turnover for hardware replacement. The Loss of Computer procedure PT/O/A/0600/001A, Loss of Computer, is in progress, however an RCS Leakage Calculation has not been performed during this shift.

INITIATING CUES The Control Room SRO directs you to perform a manual RCS leakage calculation per PT/1A/0600/010 (Reactor Coolant Leakage) Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet) using the data collected below.

Manual RCS Leakage Data Parameter Initial Final Time 0015 0115 Pzr level 219.0 inches 219.5 inches Tave Indication 579.0°F 579.1°F Quench Tank Level 86.5 inches 86.5 inches LDST Level 76.7 inches 74.0 inches Power Range NI 100.0% 100.1%

RCS NR Pressure 2150 psig 2150 psig Group 7 Control Rod Position 92.7% 92.7%

Admin-131 1.1R Page 5 of 10 START TIME: _______

STEP 1: Step 2.1 Record Initial Data in "Table #1".

Value Initial Data Minus Final Data Equals Change PZR Level 219.0 inches - =

RCS Temp 579.0°F - =

QT Level 86.5 inches - = ____Sat LDST Level 76.7 inches - =

Rx Power 100.0% - =

RCS Press 2150 psig - = ____Unsat CR Pos 92.7% - =

STANDARD: Student enters initial set of data into Table #1 of Enclosure 13.3 (Manual Leakage Calculation Data Sheet) from the initiating cue.

COMMENTS STEP 2: Step 2.2 Record time Initial Data recorded: ____________

____Sat STANDARD: Student enters 0015 (from initiating cue)

COMMENTS ____Unsat

Admin-131 1.1R Page 6 of 10 STEP 3: Step 2.3 After 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, record Final Data in "Table #1".

Value Initial Data Minus Final Data Equal Change PZR Level 219.0 inches - 219.5 inches =

RCS Temp 579.0°F - 579.1°F =

QT Level 86.5 inches - 86.5 inches =

LDST Level 76.7 inches - 74.0 inches = ____Sat Rx Power 100.0% - 100.1% =

RCS Press 2150 psig - 2150 psig =

CR Pos 92.7% - 92.7% = ____Unsat STANDARD: Student enters final set of data into Table #1 of Enclosure 13.3 (Manual Leakage Calculation Data Sheet) (from initiating cue)

COMMENTS STEP 4: Step 2.4 Record time Final Data recorded: ____________

____Sat STANDARD: Student enters 0115 COMMENTS ____Unsat STEP 5: Step 2.5 CRITICAL STEP Record time elapsed time: ____________ minutes STANDARD: Student enters 60 minutes

____Sat COMMENTS

____Unsat

Admin-131 1.1R Page 7 of 10 STEP 6: Step 2.6 CRITICAL STEP Calculate and record "Change" values in "Table # 1"..

Value Initial Data Minus Final Data Equal Change PZR Level 219.0 inches - 219.5 inches = -.5 inches RCS Temp 579.0°F - 579.1°F = -.1°F ____Sat QT Level 86.5 inches - 86.5 inches = 0 inches LDST Level 76.7 inches - 74.0 inches = +2.7 inches Rx Power 100.0% - 100.1% = -.1% ____Unsat RCS Press 2150 psig - 2150 psig = 0 psig CR Pos 92.7% - 92.7% = 0%

STANDARD: Student calculates the change in data and fills in Table 1 change column.

COMMENTS STEP :7 Step 2.7 CRITICAL STEP Calculate Corrected Pzr Level Change:

____Sat STANDARD: -0.5 inches - (6.831 inches/°F X -.1°F) = +.1831 inches

(+.18 to +.2)

____Unsat COMMENTS STEP :8 Step 2.8 CRITICAL STEP Convert Corrected Pzr Level Change to gallons STANDARD: +.1831 inches X 14.364 gallons / inch = +2.63 gallons

____Sat

(+.18 to +.2) ( 2.585 to 2.873)

COMMENTS

____Unsat

Admin-131 1.1R Page 8 of 10 STEP :9 Step 2.9 CRITICAL STEP Convert QT Level Change to gallons:

STANDARD: No change

____Sat COMMENTS

____Unsat STEP :10 Step 2.10 CRITICAL STEP Convert LDST Level Change to gallons STANDARD: +2.7 inches X 30.956 gallons / inch = +83.5812 gallons

____Sat

(+83.5 to +83.6)

COMMENTS ____Unsat STEP :11 Step 2.11 CRITICAL STEP Calculate Total Volume Change STANDARD: 2.63 gallons + 0 gallons + 83.5812 gallons = 86.2112 gallons

____Sat (2.585 to 2.873) (+83.5 to +83.6) (86.08 to 86.47)

COMMENTS

____Unsat STEP :12 Step 2.12 CRITICAL STEP Calculate "RCS Unidentified Leakage Rate" STANDARD: 86.2112 gallons / 60 minutes = 1.437 gpm

____Sat (86.08 to 86.47) (1.434 to 1.441)

COMMENTS ____Unsat END TASK STOP TIME: ____________

Admin-131 1.1R Page 9 of 10 CRITICAL STEP EXPLANATIONS:

STEP # Explanation 5 Necessary data calculation to properly determine manual RCS leakage rate.

6 Necessary data calculation to properly determine manual RCS leakage rate.

7 Necessary data calculation to properly determine manual RCS leakage rate.

8 Necessary data calculation to properly determine manual RCS leakage rate.

9 Necessary data calculation to properly determine manual RCS leakage rate.

10 Necessary data calculation to properly determine manual RCS leakage rate.

11 Necessary data calculation to properly determine manual RCS leakage rate.

12 Necessary data calculation to properly determine manual RCS leakage rate.

1.1R CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS Oconee Unit 1 computer repairs are expected to be extended through turnover for hardware replacement. The Loss of Computer procedure PT/O/A/0600/001A, Loss of Computer, is in progress, however an RCS Leakage Calculation has not been performed during this shift.

INITIATING CUES The Control Room SRO directs you to perform a manual RCS leakage calculation per PT/1A/0600/010 (Reactor Coolant Leakage) Encl. 13.3 (Manual RCS Leakage Calculation Data Sheet) using the data collected below.

Manual RCS Leakage Data Parameter Initial Final Time 0015 0115 Pzr level 219.0 inches 219.5 inches Tave Indication 579.0°F 579.1°F Quench Tank Level 86.5 inches 86.5 inches LDST Level 76.7 inches 74.0 inches Power Range NI 100.0% 100.1%

RCS NR Pressure 2150 psig 2150 psig Group 7 Control Rod Position 92.7% 92.7%

Admin-142 - 1.2B Page 1 of 9 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Admin-142 Determine Time for SFP to reach 180ºF CANDIDATE EXAMINER

Admin-142 - 1.2B Page 2 of 9 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:

Determine Time for SFP to reach 180ºF Alternate Path:

N/A Facility JPM #:

New K/A Rating(s):

System: GEN K/A: 2.1.25 Rating: 3.9/4.2 Task Standard:

Tables in AP/1-2/A/1700/035 (Loss of SFP Cooling And/Or Level) are used to determine total time required for SFP temperature to reach 180ºF Preferred Evaluation Location: Preferred Evaluation Method:

Simulator _____ In-Plant _____ Classroom __ X ___ Perform __X___ Simulate ____

References:

AP/1-2/A/1700/035 (Loss of SFP Cooling And/Or Level)

Validation Time: 15 minutes Time Critical: NO

========================================================================

Candidate: _______________________________________ Time Start: _________

NAME Time Finish: ________

Performance Rating: SAT ______ UNSAT ______ Performance Time: _________

Examiner: ______________________________ ____________________________________/________

NAME SIGNATURE DATE

========================================================================

COMMENTS

Admin-142 - 1.2B Page 3 of 9 SIMULATOR OPERATOR INSTRUCTIONS:

NONE

Admin-142 - 1.2B Page 4 of 9 Tools/Equipment/Procedures Needed:

AP/1-2/A/1700/035 (Loss of SFP Cooling And/Or Level)

READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

  • Unit 1 is at 100% stable
  • Unit 2 was operating at 100% when it experienced a Unit blackout
  • SSF has been activated for Unit 2
  • Unit 2 RCMUP is aligned and operating
  • 2HP-426 is being cycled to maintain Pressurizer Level as directed by AP/25
  • AP/1-2/A/1700/035 (Loss of SFP Cooling And/Or Level) has been initiated
  • Unit 1 & 2 SFP level = 0 stable
  • Unit 1 & 2 SFP temperature = 102 ºF INITIATING CUES:

CRS has directed you to utilize AP/35 Enclosure 5.4 and determine the time for Unit 1&2 SFP to reach 180 ºF

Admin-142 - 1.2B Page 5 of 9 START TIME: _______

STEP 1: CRITICAL STEP

1. Refer to tables A, B, and C below.
2. ONLY one row from one table below applies ___ SAT
3. Check the row in Table A, B, or C that applies to current conditions, and then use Tables listed on subsequent pages of Encl 5.4, as directed, to calculate SFP heat up ___ UNSAT times.

STANDARD: Candidate selects Table B and then chooses to use Table 10 based on

1. SSF Event in progress for U1 or U2 with Unit letdown going to SFP AND
2. U1 and U2 each have 177 Fuel Assemblies in RB Candidate proceeds to Table 10 (page 33 of 63)

COMMENTS:

Admin-142 - 1.2B Page 6 of 9 STEP 2: Determine the Time (in days) row based on direction from CRITICAL STEP page 5 of 63

___ SAT STANDARD:

  • Candidate selects the lower EFPD unit and adds 20 which results in 67 days.

___ UNSAT

  • Determine that 67 days is between 60 and 70 days on the far left column of Table 10
  • Based on guidance in Step 7 on Page 7 of 63, elects to use 60 days (the shorter time).

Note: Step 2 and Step 3 can be performed in any order COMMENTS:

STEP 3: Determine initial Spent Fuel Pool Temperature column CRITICAL STEP based on directions from page 7 of 63 Step 6.

___ SAT STANDARD:

  • Actual SFP temp = 102ºF
  • Temperature columns available are 100 and 105 ___ UNSAT
  • Based on directions in step 6, elects to use the 105 (higher) column Note: Step 2 and Step 3 can be performed in any order COMMENTS:

Admin-142 - 1.2B Page 7 of 9 STEP 4: Find the Time in hours based on the intersection of the 60 CRITICAL STEP day row and the 105 degree column.

___ SAT STANDARD: Based on the intersection of the 60 day row and the 105 degree column, determine that 16.4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> is the time to reach 180ºF

___ UNSAT COMMENTS:

END TASK STOP TIME: ____________

Admin-142 - 1.2B Page 8 of 9 CRITICAL STEP EXPLANATIONS:

STEP # Explanation 1 Required to determine the time to reach 180 ºF 2 Required to determine the time to reach 180 ºF 3 Required to determine the time to reach 180 ºF 4 Required to determine the time to reach 180 ºF

CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

  • Unit 1 is at 100% stable
  • Unit 2 was operating at 100% when it experienced a Unit blackout
  • SSF has been activated for Unit 2
  • Unit 2 RCMUP is aligned and operating
  • 2HP-426 is being cycled to maintain Pressurizer Level as directed by AP/25
  • AP/1-2/A/1700/035 (Loss of SFP Cooling And/Or Level) has been initiated
  • Unit 1 & 2 SFP level = 0 stable
  • Unit 1 & 2 SFP temperature = 102 ºF INITIATING CUES:

CRS has directed you to utilize AP/35 Enclosure 5.4 and determine the time for Unit 1&2 SFP to reach 180 ºF

Admin-240 2R Page 1 of 9 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Admin-240 Perform SG Downcomer Temperature Surveillance CANDIDATE EXAMINER

Admin-240 2R Page 2 of 9 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:

Perform SG Downcomer Temperature Surveillance Alternate Path:

N/A Facility JPM #:

Admin-237 K/A Rating(s):

System: Gen K/A: 2.2.12 Rating: 3.7/4.1 Task Standard:

Perform SG Downcomer Temperature Surveillance by procedure for the 1A (ONLY) SG and determine that the surveillance requirement is NOT met for either of the specified computer points.

Preferred Evaluation Location: Preferred Evaluation Method:

Simulator ___ __ In-Plant __ ___ Classroom __X__ Perform __X__ Simulate _____

References:

OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl 4.1 (Mode 1 & 2)

OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl. 4.19 (Channel Check Of OTSG Downcomer Temperatures)

Validation Time: 18 minutes Time Critical: NO

========================================================================

Candidate: _______________________________________ Time Start: _________

NAME Time Finish: ________

Performance Rating: SAT ______ UNSAT ______ Performance Time: _________

Examiner: ______________________________ ____________________________________/________

NAME SIGNATURE DATE

========================================================================

COMMENTS

Admin-240 2R Page 3 of 9 SIMULATOR OPERATOR INSTRUCTIONS NONE

Admin-240 2R Page 4 of 9 Tools/Equipment/Procedures Needed:

OP/1/A/1105/014 (Control Room Instrumentation Operation And Information)

OAC Screen capture image for SG information READ TO OPERATOR DIRECTION TO TRAINEE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

Reactor power = 75%

OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl. 4.1 (Mode 1 & 2) in progress.

INITIATING CUES:

CR SRO directs you to perform OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl. 4.1 (Mode 1 & 2) on page 6 of 15 component check for the 1A SG Downcomer Temperature.

Admin-240 2R Page 5 of 9 START TIME: _______

STEP 1: Enclosure 4.1 (page 6 of 15) CRITICAL STEP Verify All SG Downcomer Temperature computer points agree within 3°F of each other.

___ SAT IF All SG Downcomer Temperatures DO NOT agree within 3°F of each other, then perform Enclosure "Channel Check Of OTSG Downcomer Temperatures".

___ UNSAT O1E2008 - 528.87°F O1E2009 - 538.97°F O1E2012 - 532.78°F O1E2013 - 533.65°F STANDARD: Determine that the above OAC points do NOT agree within 3°F of each other, and perform Enclosure 4.19 "Channel Check of OTSG Downcomer Temperatures".

COMMENTS:

STEP 2: Step 3.1 (Enclosure 4.19)

Determine saturation temperature for 1A OTSG based on power level and 1A OTSG outlet pressure as follows:

___ SAT Step 3.1.1 Determine 1A OTSG outlet pressure using any one of the following computer points:

___ UNSAT

  • O1E2281 - 888.5 psig
  • O1E2283 - 888.5 psig
  • O1E2031 - 888.5 psig
  • O1E2032 - 888.5 psig STANDARD: Using the OAC determine that 1A OTSG pressure is 888.5.

COMMENTS:

Admin-240 2R Page 6 of 9 STEP 3: Step 3.1.2 CRITICAL STEP Using table in Section 4, determine the 1A OTSG saturation temperature based on power level and 1A OTSG Outlet Pressure obtained in step 3.1.1.

___ SAT

____________ 1A OTSG saturation temperature STANDARD: Determine that 1A OTSG saturation temperature is 533.9ºF (533.8 - ___ UNSAT 534.0) by using the table in section 4.

COMMENTS:

STEP 4: Step 3.1.3 CRITICAL STEP Compare O1E2008 SG Lower Downcomer Temperature Loop A to the 1A OTSG saturation temperature determined in step 3.1.2:

___ SAT Step 3.1.4 IF O1E2008 SG Lower Downcomer Temperature Loop A is NOT within

+/- 4.9 °F of the 1A OTSG saturation temperature, then enter Condition A of SLC 16.7.5 for OTSG overfill protection system inoperable. ___ UNSAT STANDARD: Determine that O1E2008 SG Lower Downcomer Temperature Loop A (528.87°F) is NOT within +/- 4.9 °F of the 1A OTSG saturation temperature (533.9°F), and entry Condition A of SLC 16.7.5 for OTSG overfill protection system inoperable is required.

COMMENTS:

Admin-240 2R Page 7 of 9 STEP 5: Step 3.1.5 CRITICAL STEP Compare O1E2009 SG Lower Downcomer Temperature Loop A to the 1A OTSG saturation temperature determined in step 3.1.2:

___ SAT Step 3.1.6 IF O1E2009 SG Lower Downcomer Temperature Loop A is NOT within

+/- 4.9 °F of the 1A OTSG saturation temperature, then enter Condition A of SLC 16.7.5 for OTSG overfill protection system inoperable. ___ UNSAT STANDARD: Determine that O1E2009 SG Lower Downcomer Temperature Loop A (538.97) is NOT within +/- 4.9 °F of the 1A OTSG saturation temperature (533.9°), and entry Condition A of SLC 16.7.5 for OTSG overfill protection system inoperable is required.

Cue: Inform the candidate that another operator will complete this procedure.

COMMENTS:

END TASK STOP TIME: ____________

Admin-237 Page 8 of 9 CRITICAL STEP EXPLANATIONS:

STEP # Explanation 1 Step is required to complete the surveillance.

3 Step is required to complete the surveillance.

4 Determining that the computer points in both Step 4 and Step 5 are out of the allowable band is critical to ensure that SLC 16.7.5 Condition A is not exited prior to BOTH computer points being repaired.

5 Determining that the computer points in both Step 4 and Step 5 are out of the allowable band is critical to ensure that SLC 16.7.5 Condition A is not exited prior to BOTH computer points being repaired.

2R CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

Reactor power = 75%

OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl. 4.1 (Mode 1 &

2) in progress.

INITIATING CUES:

CR SRO directs you to perform OP/1/A/1105/014 (Control Room Instrumentation Operation And Information) Encl. 4.1 (Mode 1 & 2) on page 6 of 15 component check for the 1A SG Downcomer Temperature.

ADMIN-241 2S Page 1 of 9 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE ADMIN-241 Complete a Surveillance Evaluation (SRO ONLY)

CANDIDATE EXAMINER

ADMIN-241 2S Page 2 of 9 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:

Complete PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.12 (Surveillance Evaluation)

Alternate Path:

N/A Facility JPM #:

New K/A Rating(s):

System: Gen K/A: 2.2.12 Rating: 3.7/4.1 Task Standard:

Complete PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.12 (Surveillance Evaluation)

Preferred Evaluation Location: Preferred Evaluation Method:

Simulator __ ___ In-Plant ___ ___ Classroom __ X___ Perform __ X__ Simulate_ __

References:

PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) page 25 of 26 PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.9 (RCP Power Supply Verification)

PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.12 (Surveillance Evaluation)

Validation Time: 20 min. Time Critical: No

=========================================================================

Candidate: _______________________________________ Time Start: _________

NAME Time Finish: ________

Performance Rating: SAT ______ UNSAT ______ Performance Time: _________

Examiner: ______________________________ ___________________________________/_________

NAME SIGNATURE DATE

=========================================================================

Comments

ADMIN-241 2S Page 3 of 9 SIMULATOR OPERATOR INSTRUCTIONS NONE

ADMIN-241 2S Page 4 of 9 Tools/Equipment/Procedures Needed:

PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) page 25 of 26 PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.9 (RCP Power Supply Verification)

PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.12 (Surveillance Evaluation)

Surveillance Frequency List READ TO OPERATOR DIRECTIONS TO STUDENT I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

Time/Date = 0830 on Saturday, June 8.

RCS Temperature = 298 °F.

1/0 RCP operation in progress (1A1 RCP in operation).

PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) in progress.

SR 3.4.5.2 on page 25 of 26 of PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) is being performed.

Step 2.2 of Encl. 13.9 (RCP Power Supply Verification) is determined to NOT be satisfied because neither the 1B1 nor the 1B2 RCP has power available.

INITIATING CUE:

Based on the above conditions, complete PT/1/A/0600/001 (Periodic Instrument Surveillance)

Encl. 13.12 (Surveillance Evaluation)

ADMIN-241 2S Page 5 of 9 START TIME: _______

STEP 1: Surveillance

Description:

STANDARD: Documents that this is a Tech Spec required verification of correct RCP ___ SAT breaker alignment of power available to the required pump this is not in operation

___ UNSAT COMMENTS:

STEP 2: Applicable TS(s)/SLC(s)/Site Directive(s), etc.: CRITICAL STEP STANDARD: Determines that Tech Spec 3.4.5 (RCS Loops Mode 3) is applicable and documents in Step 2 ___ SAT COMMENTS:

___ UNSAT STEP 3: Description of discrepancy/deficiency:

STANDARD: Documents that the required RCP Breaker alignment does not exist. ___ SAT NOTE: TS 3.4.5 requires that either the 1B1 or 1B2 have power available

___ UNSAT COMMENTS:

STEP 4: Is surveillance applicable for present plant conditions? CRITICAL STEP STANDARD: Marks yes

___ SAT COMMENTS:

___ UNSAT

ADMIN-241 2S Page 6 of 9 STEP 5: If surveillance is applicable, what is the latest due date for surveillance CRITICAL STEP OR applicable LCO?

STANDARD: Documents that the latest due date is 0830 on Tuesday, June 11 (72 ___ SAT hours from discovery) per Condition A of TS 3.4.5 COMMENTS:

___ UNSAT STEP 6: Is applicable TS(s)/SLC(s)/Site Directive(s), etc. satisfied with existing *CRITICAL STEP discrepancy/deficiency?

STANDARD: ___ SAT

  • *Marks no
  • Explains in justification that TS 3.4.5 requires both RCS loops be Operable and with no power available to the 1B1 and 1B2 RCPs, the B RCS loop is NOT operable ___ UNSAT COMMENTS:

STEP 7: Support personnel/groups contacted (if any) AND information provided:

STANDARD: Candidate may indicate requesting SPOC assistance to determine why ___ SAT neither of the required RCP breakers are racked in however since there is no indication of mechanical failures it would not be required.

___ UNSAT COMMENTS:

ADMIN-241 2S Page 7 of 9 STEP 8: Describe corrective/compensatory actions being taken (procedure change, WR, PIP, etc.), and resolution date for those actions. ___ SAT STANDARD:

  • Corrective/Compensatory Action: ___ UNSAT Candidate should indicate that actions will commence to establish the required breaker alignment. This could be by issuing a Work Request, writing a PIP, or dispatching personnel to determine why the breakers are open and if the breakers could be racked in.

Resolution Date:

This blank may be left open at this time since the investigation is just beginning however in no case should a date and time that would result in exceeding the 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> completion time be entered.

COMMENTS:

STEP 9: Approval:

STANDARD: Signs and Dates either of the blanks provided ___ SAT COMMENTS:

___ UNSAT END OF TASK

ADMIN-241 2S Page 8 of 9 CRITICAL STEP EXPLANATIONS STEP # Explanation 2 Required to determine the applicable Tech Spec 4 Required to determine if this Tech Spec is applicable in Mode 3 5 Incorrect documentation could lead to exceeding allowed time to complete Tech Spec Required Actions.

6 Required to determine if the LCO is met

2S CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

Time/Date = 0830 on Saturday, June 8.

RCS Temperature = 298 °F.

1/0 RCP operation in progress (1A1 RCP in operation).

PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) in progress.

SR 3.4.5.2 on page 25 of 26 of PT/1/A/0600/001 (Periodic Instrument Surveillance) Encl. 13.2 (Mode 3) is being performed.

Step 2.2 of Encl. 13.9 (RCP Power Supply Verification) is determined to NOT be satisfied because neither the 1B1 nor the 1B2 RCP has power available.

INITIATING CUE:

Based on the above conditions, complete PT/1/A/0600/001 (Periodic Instrument Surveillance)

Encl. 13.12 (Surveillance Evaluation)

Admin-306 3B Page 1 of 8 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Admin-306 Calculate the Maximum Permissible Stay Time Within Emergency Dose Limits (EDL)

CANDIDATE EXAMINER

Admin-306 3B Page 2 of 8 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:

Calculate the Maximum Permissible Stay Time Within the Emergency Dose Limits.

Alternate Path:

N/A Facility JPM #:

Admin 305 K/A Rating(s):

System: Gen K/A: 2.3.4 Rating: 3.2/3.7 Task Standard:

Calculate the Maximum Permissible Stay Time Within the Emergency Dose Limits.

Preferred Evaluation Location: Preferred Evaluation Method:

Simulator _____ In-Plant ______ Classroom _ _X_ Perform __X__ Simulate _____

References:

NSD-507 (Radiation Protection)

OMP 1-18 (Implementation Standard During Abnormal And Emergency Events)

Validation Time: 20 min. Time Critical: No

=========================================================================

Candidate: _______________________________________ Time Start: _________

NAME Time Finish: ________

Performance Rating: SAT ______ UNSAT ______ Performance Time _________

Examiner: ______________________________ ____________________________________/_________

NAME SIGNATURE DATE

=========================================================================

=

COMMENTS

Admin-306 3B Page 3 of 8 SIMULATOR OPERATOR INSTRUCTIONS NONE

Admin-306 3B Page 4 of 8 Tools/Equipment/Procedures Needed:

Calculator Note tablet READ TO OPERATOR DIRECTIONS TO STUDENT I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS Steam Generator Tube Rupture has occurred on Unit 3 Emergency Dose Limits are in effect NEO A has received 1.26 Rem TEDE this year The following tasks are required to be performed:

0B TASK 1B TIME REQUIRED 2B DOSE RATE 3B 1

4B Close 3C-573 5B 11 min 6B 6.15 R/hr 7B 2

8B Open 3FDW-313 9B 6 min 10B 18.25 R/hr 1B 3

12B Open all Unit 3s ADVs 13B 4.65 R/hr 14B Note: Assume no dose is received while traveling between tasks.

INITIATING CUE Refer to the above information. NEO A has completed tasks 1 and 2 in the time required.

Determine how long the NEO has to complete task 3 without exceeding his/her Emergency Dose Limits.

Admin-306 3B Page 5 of 8 START TIME: _______

Examiner Note:

  • Candidate may perform these steps in a different order; however, the calculated stay time must be correct.
  • Current exposure for the year is not counted toward the Emergency Dose Limits (EDL).

STEP 1: Determine dose received while performing task 1. CRITICAL STEP STANDARD: Determine dose received while performing task 1. ___ SAT 6.15 R/hr X 1hr/60 min X 11 min = 1.1275 R (1.12 to 1.13 R) ___ UNSAT COMMENTS:

STEP 2: Determine dose received while performing task 2. CRITICAL STEP

___ SAT STANDARD: Determine dose received while performing task 2.

18.25 R/hr X 1hr/60 min X 6 min = 1.825 R

___ UNSAT (1.82 to 1.83 R)

COMMENTS:

STEP 3: Determine dose remaining from EDLs. CRITICAL STEP

___ SAT STANDARD: Determine dose remaining from EDLs.

5R - 1.1275R - 1.825R = 2.0475 R

___ UNSAT (2.04 to 2.06 R)

COMMENTS:

Admin-306 3B Page 6 of 8 STEP 4: Determine time available for the NEO to complete task 3 without CRITICAL STEP exceeding EDL.

___ SAT STANDARD: Stay time is calculated to be:

Available Dose = 2.0475 R = .44 hr X 60 min = 26.42 min Dose Rate 4.65 R/hr 1hr ___ UNSAT (26 to 27 Minutes)

COMMENTS:

END OF TASK STOP TIME: ________

Admin-306 3B Page 7 of 8 CRITICAL STEP EXPLANATIONS STEP # Explanation 1 Required to calculate stay time.

2 Required to calculate stay time.

3 Required to calculate stay time.

4 Required to calculate stay time.

3B CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS Steam Generator Tube Rupture has occurred on Unit 3 Emergency Dose Limits are in effect NEO A has received 1.26 Rem TEDE this year The following tasks are required to be performed:

15B TASK 16B TIME REQUIRED 17B DOSE RATE 18B 1

19B Close 3C-573 20B 11 min 21B 6.15 R/hr 2B 2

23B Open 3FDW-313 24B 6 min 25B 18.25 R/hr 26B 3

27B Open all Unit 3s ADVs 28B 4.65 R/hr 29B Note: Assume no dose is received while traveling between tasks.

INITIATING CUE Refer to the above information. NEO A has completed tasks 1 and 2 in the time required.

Determine how long the NEO has to complete task 3 without exceeding his/her Emergency Dose Limits.

ADMIN-412 4S Page 1 of 11 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE ADMIN-412 Determine Emergency Classification and complete the initial Emergency Notification form (SRO Only)

CANDIDATE EXAMINER

ADMIN-412 4S Page 2 of 11 REGION II INITIAL LICENSE EXAMINATION JOB PERFORMANCE MEASURE Task:

Determine Emergency Classification and complete the initial Emergency Notification form Alternate Path:

N/A Facility JPM #:

N/A K/A Rating(s):

System: Gen K/A: 2.4.38 Rating: 2.4/4.4 Task Standard:

Appropriate classification is determined and associated Emergency Notification Form is completed with the time critical criteria.

Preferred Evaluation Location: Preferred Evaluation Method:

Simulator __ ___ In-Plant ___ ___ Classroom __ X___ Perform __ X__ Simulate_ __

References:

RP/0/B/1000/001 (Emergency Classification)

RP/0/B/1000/002 (Control Room Emergency Coordinator Procedure)

Nuclear Power Plant Emergency Notification Form 4.1.A.1 Validation Time: 20 min. Time Critical: Yes

=========================================================================

Candidate: _______________________________________ Time Start: _________

NAME Time Finish: ________

Performance Rating: SAT ______ UNSAT ______ Performance Time: _________

Examiner: ______________________________ ___________________________________/_________

NAME SIGNATURE DATE

=========================================================================

Comments

ADMIN-412 4S Page 3 of 11 SIMULATOR OPERATOR INSTRUCTIONS NONE

ADMIN-412 4S Page 4 of 11 Tools/Equipment/Procedures Needed:

RP/0/B/1000/001 (Emergency Classification)

RP/0/B/1000/002 (Control Room Emergency Coordinator Procedure)

READ TO OPERATOR DIRECTIONS TO STUDENT I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

0800 Unit 1 experiences a runback and trip due to a loss of Stator Coolant.

0805 The Operator dispatched to determine if the MS Relief Valves have reseated reports that 1B SG appears to have two MSRVs damaged and still passing steam.

0806 1B SG has been isolated and RCS Temperature stabilized at 520°F CETCs.

0815 Calculations indicate a 1A S/G Tube leak of 240 gpm is occurring. 1RIA-40 = 1,245 cps and increasing.

0816 The 1A S/G is being fed by the 1A MDEFWP and is being used for RCS Temperature control. Feeding the 1B S/G for Tube to Shell Delta Temperature concerns is NOT required at this time.

INITIATING CUE:

Perform the required actions of the Emergency Coordinator:

1. Determine Emergency Classification at Time = 0816
2. Complete appropriate Emergency Notification Form THIS IS A TIME CRITICAL JPM Note: Do not use Emergency Coordinators judgment while classifying the event. When required, other operators will maintain the Emergency Coordinators Log and perform the duties of the Control Room Offsite Communicator.

ADMIN-412 4S Page 5 of 11 START TIME: _______

(Actual time)

STEP 1: Classify the Event CRITICAL STEP STANDARD: Refer to RP/0/B/1000/01 (Emergency Classification) Enclosure 4.1 (Fission Product Barrier Matrix) ___ SAT Classify as an ALERT due to:

  • RCS Barriers - 4 points due to SGTR >160 gpm

___ UNSAT Time of Classification: _________________

Examiner Note: The criteria for getting 3 points for a SGTL in one S/G and the other S/G faulted is not met because the faulted S/G (1B) has been isolated.

COMMENTS:

STEP 2: Commence the Off-Site Notification Form.

STANDARD: Go to RP/0/B/1000/002 (Control Room Emergency Coordinator ___ SAT Procedure) and initiate procedure by determining symptoms for entry exist and check Step 1.1

___ UNSAT COMMENTS:

STEP 3: Step 2.1.

STANDARD: Determine step 2.1 does not apply ___ SAT COMMENTS:

___ UNSAT

ADMIN-412 4S Page 6 of 11 NOTE:

State and County agencies shall be notified within 15 minutes of E-plan declaration, Classification upgrades, and Protective Action Recommendations.

___ SAT STEP 4: Step 2.2 Declare the appropriate Emergency Classification level.

Classification __ALERT_____ (UE, ALERT, SAE, GE)

Time Declared: _________ ___ UNSAT STANDARD: Declare an ALERT due to:

1A SGTR > 160 gpm ( 4 pts.) and the SG with an open path to the environment (1B SG) is NOT being fed by the affected unit nor does it contain a SG Tube Leak

  • Time ALERT Declared documented in Step 1
  • (SAT is < Start Time + 15 minutes)

COMMENTS:

STEP 5: Step 2.3 & 2.4 STANDARD: Determine Steps 2.3 and 2.4 do not apply ___ SAT COMMENTS:

___ UNSAT STEP 6: Step 2.5 Appoint Control Room Offsite Communicator(s) and perform the following: N/A

___ SAT STANDARD: Any name (real or imaginary) is acceptable.

Note: Initiating Cue indicates these actions will be performed by another operator.

___ UNSAT COMMENTS:

ADMIN-412 4S Page 7 of 11 STEP 7: Step 2.6 IAAT Changing plant conditions require an emergency classification upgrade,

___ SAT THEN Notify Offsite Communicator to complete the in-progress notifications per RP/0/B/1000/15A, (Offsite Communications From The CR)

AND Re-initiate a clean copy of this procedure for the upgraded

___ UNSAT classification and stop this procedure.

STANDARD: An Upgrade is not expected.

COMMENTS:

STEP 8: Step 2.7 CRITICAL STEP Obtain the appropriate Offsite Notification form from the Emergency

___ SAT Plan cart.

STANDARD: Initial ALERT form # 4.1.A.1 is selected and candidate continues to fill-

___ UNSAT out form per the Step 2.7 substeps.

COMMENTS:

ADMIN-412 4S Page 8 of 11 STEP 9: Step 2.7 (continued) *CRITICAL STEP 2.7.1. Ensure EAL # as determined by RP/0/B/1000/001 matches Line 4.

(4.1.A.1) 2.7.2. Line 1 - Mark appropriate box "Drill" or "Actual Event" (DRILL) 2.7.3. *Line 1 - Enter Message # (#1) 2.7.4. *Line 2 - Mark Initial (INITIAL marked) ___ SAT 2.7.5. *Line 6 - (Is Occurring marked)

A. Mark "Is Occurring" if any of the following are true:

  • RIAs 40, 45, or 46 are increasing or in alarm ___ UNSAT
  • If containment is breached
  • Containment pressure > 1 psig B. Mark "None" if none of the above is applicable.

2.7.6. *Line 7 - If Line 6 Box B or C is marked, mark Box D. Otherwise mark Box A (D marked) 2.7.7. *Line 8 - Mark "Stable" unless an upgrade or additional PARs are anticipated within an hour.

  • Refer to Enclosure 4.9, (Event Prognosis Definitions) 2.7.8. *Line 10 - Military time and date of declaration (Refer to date/time in Step 2.2) (Insert time from STEP 1 and todays date, military time is not critical as long as time is specific and accurate.)

2.7.9. Line 11 - If more than one unit affected, mark "All" (Unit 1 marked) 2.7.10. Line 12 - Mark affected unit(s) (reference Line 11) AND enter power level of affected unit(s) or time/date of shutdown (Unit 1 - 0% power, Shutdown at 0800 with todays date.)

2.7.11. Line 13 - If the OSM has no remarks, write "None" (indicate NONE) 2.7.12. If Condition "A" exists ensure following PARs are included Line 5.

A. Evacuate: Move residents living downstream of the Keowee Hydro Project dams to higher ground B. Other: Prohibit traffic flow across bridges identified on your inundation maps until the danger has passed. (Condition A does not exist. No PAR required)

STANDARD: Correctly fills out Emergency Notification Form in accordance with Key.

COMMENTS:

ADMIN-412 4S Page 9 of 11 STEP 10: Step 2.7 (Continued) CRITICAL STEP 2.7.13. Line 17 - OSM signature, CURRENT Time/Date (MUST SIGN)

STANDARD: Indicate that OSM signature will be obtained on the completed Emergency Notification Form within 15 minutes of classification time recorded in step 1.

STOP TIME #2: Time for Notification __________

(SAT is < Step 1 Time + 15 minutes)

COMMENTS:

END OF TASK

ADMIN-412 4S Page 10 of 11 CRITICAL STEP EXPLANATIONS STEP # Explanation 1 The candidate needs to be able to utilize the procedure and determine the conditions meet a Site Area Emergency classification within 15 minutes.

8 The correct form that matches the EAL # is selected.

9 The emergency notification form is filled-out with each line entry identified as critical complete and accurate.

10 This is a time critical step. The Candidate needs to complete the notification form within 15 minutes from the time the EAL was declared. (Declaration time is the time recorded in JPM step 4)

4S CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

0800 Unit 1 experiences a runback and trip due to a loss of Stator Coolant.

0805 The Operator dispatched to determine if the MS Relief Valves have reseated reports that 1B SG appears to have two MSRVs damaged and still passing steam.

0806 1B SG has been isolated and RCS Temperature stabilized at 520°F CETCs.

0815 Calculations indicate a 1A S/G Tube leak of 240 gpm is occurring. 1RIA-40 = 1,245 cps and increasing.

0816 The 1A S/G is being fed by the 1A MDEFWP and is being used for RCS Temperature control. Feeding the 1B S/G for Tube to Shell Delta Temperature concerns is NOT required at this time.

INITIATING CUE:

Perform the required actions of the Emergency Coordinator:

1. Determine Emergency Classification at Time = 0816
2. Complete appropriate Emergency Notification Form THIS IS A TIME CRITICAL JPM Note: Do not use Emergency Coordinators judgment while classifying the event. When required, other operators will maintain the Emergency Coordinators Log and perform the duties of the Control Room Offsite Communicator.