| issue date = 09/05/2006 | | issue date = 09/05/2006 | ||
| title = E-mail Dated September 5, 2006, to Yankee Atomic Electric Company Forwarding Comments on Final Status Survey Reports | | title = E-mail Dated September 5, 2006, to Yankee Atomic Electric Company Forwarding Comments on Final Status Survey Reports | ||
| author name = Hickman J | | author name = Hickman J | ||
| author affiliation = NRC/FSME/DWMEP | | author affiliation = NRC/FSME/DWMEP | ||
| addressee name = Carson A | | addressee name = Carson A | ||
Line 15: | Line 15: | ||
=Text= | =Text= | ||
{{#Wiki_filter:_John Hickaman_-_FS Data Issues ... .Page,1 From: John Hickman To: Yankee, Alice Carson Date: 09/05/2006 4:29:56 PM | {{#Wiki_filter:_John Hickaman_-_FS Data Issues ... .Page,1 From: John Hickman To: Yankee, Alice Carson Date: 09/05/2006 4:29:56 PM | ||
==Subject:== | ==Subject:== | ||
FSS Data Issues Alice, The following are the data issues that Tom needs resolved: TBN-01 -02 through TBN-01 -08 (1) Systematic Survey Data Table 10 provides the survey design and indicates that all are Class 1 survey units. The survey design or Section 5.2.1.4 narrative indicates that 15 fixed-point samples will be taken in each survey unit. Table 13 provides the systematic survey data, but the results are in cpm. Table 11 provides the DCGL-w, DCGL-EMC and Investigation levels as dpm/100cm2 units. The staff cannot determine if the DCGLs are exceeded or not.(2) Scan Survey Data The staff cannot identify the scan survey data for these survey units in the FSS Report or attachments. | FSS Data Issues Alice, The following are the data issues that Tom needs resolved: | ||
NOL-01 -01 and NYS-12-01 The FSS Reports listed are both MARSSIM class 1 survey units, and require both systematic surveys and scan surveys.The staff cannot locate the scan survey data for NOL-01-01. | TBN-01 -02 through TBN-01 -08 (1) Systematic Survey Data Table 10 provides the survey design and indicates that all are Class 1 survey units. The survey design or Section 5.2.1.4 narrative indicates that 15 fixed-point samples will be taken in each survey unit. Table 13 provides the systematic survey data, but the results are in cpm. Table 11 provides the DCGL-w, DCGL-EMC and Investigation levels as dpm/100cm2 units. The staff cannot determine if the DCGLs are exceeded or not. | ||
NOL-01 has four (4) survey units. ISOCS scan data or a data summary was identified for the other three (3) survey units.The staff cannot locate scan survey data for NYS-12-01 in the report or attachments. | (2) Scan Survey Data The staff cannot identify the scan survey data for these survey units in the FSS Report or attachments. | ||
NYS-12 has a single survey unit.I also attached a WP copy of the same text.Thanks John CC: Thomas Youngblood | NOL-01 -01 and NYS-12-01 The FSS Reports listed are both MARSSIM class 1 survey units, and require both systematic surveys and scan surveys. | ||
35218) | The staff cannot locate the scan survey data for NOL-01-01. NOL-01 has four (4) survey units. ISOCS scan data or a data summary was identified for the other three (3) survey units. | ||
The staff cannot locate scan survey data for NYS-12-01 in the report or attachments. NYS-12 has a single survey unit. | |||
I also attached a WP copy of the same text. | |||
Thanks John CC: Thomas Youngblood | |||
Ic:\temp\GWJ00001.TMP V Page I Page I.6:\ten~NOW}dOOO1 .TMP Mail Envelope Properties (44FDDE44.17E:12: 35218) | |||
==Subject:== | ==Subject:== | ||
FSS Data Issues Creation Date 09/05/2006 4:29:56 PM From: John Hickman Created By-: JBH@nrc.*ov Recipients Action Date & Time comcast.net Transferred 09/05/2006 4:30:20 PM acarson1967 (Yankee Alice Carson) nrc.gov TWGWPO04.HQGWDOO1 Delivered 09/05/2006 4:30:06 PM THY CC (Thomas Youngblood) Opened 09/05/2006 4:31:33 PM Post Office Delivered Route comcast.net TWGWPO04.HQGWDOO1 09/05/2006 4:30:06 PM nrc.gov Files Size Date & Time MESSAGE 2121 09/05/2006 4:29:56 PM Data issues.wpd 3513 09/05/2006 4:27:16 PM Options Auto Delete: No Expiration Date: N4one Notify Recipients: Yes Priority: Standard ReplyRequested: No Return Notification: | |||
Priority: ReplyRequested: | |||
Return Notification: | |||
Send Notification when Opened Concealed | Send Notification when Opened Concealed | ||
==Subject:== | ==Subject:== | ||
Security: To Be Delivered: | No Security: tandard To Be Delivered: Immediate Status Tracking: I)elivered & Opened | ||
I | Ij6hn Hickman - Data- issues.wpd .. Pagel TBN-01 -02 throuqh TBN-01 -08 (1) Systematic Survey Data Table 10 provides the survey design and indicates that all are Class 1 survey units. The survey design or Section 5.2.1.4 narrative indicates that 15 fixed-point samples will be taken in each survey unit. Table 13 provides the systematic survey data, but the results are in cpm. Table 11 provides the DCGL-w, DCGL-EMC and Investigation levels as dpm/1 00cm 2 units. The staff cannot determine if the DCGLs are exceeded or not. | ||
& Opened Ij6hn Hickman -Data- issues.wpd | (2) Scan Survey Data The staff cannot identify the scan survey data for these survey units in the FSS Report or attachments. | ||
..Pagel TBN-01 -02 throuqh TBN-01 -08 (1) Systematic Survey Data Table 10 provides the survey design and indicates that all are Class 1 survey units. The survey design or Section 5.2.1.4 narrative indicates that 15 fixed-point samples will be taken in each survey unit. Table 13 provides the systematic survey data, but the results are in cpm. Table 11 provides the DCGL-w, DCGL-EMC and Investigation levels as dpm/1 00cm 2 units. The staff cannot determine if the DCGLs are exceeded or not.(2) Scan Survey Data The staff cannot identify the scan survey data for these survey units in the FSS Report or attachments. | NOL-01 -01 and NYS-12-01 The FSS Reports Iisted are both MARSSIM class 1 survey units, and require both systematic surveys and scan surveys. | ||
NOL-01 -01 and NYS-12-01 The FSS Reports Iisted are both MARSSIM class 1 survey units, and require both systematic surveys and scan surveys.The staff cannot locate the scan survey data for NOL-01 -01. NOL-01 has four (4) survey units.ISOCS scan data or a data summary was identified for the other three (3) survey units.The staff cannot locate scan survey data for NYS-12-01 in the report or attachments. | The staff cannot locate the scan survey data for NOL-01 -01. NOL-01 has four (4) survey units. | ||
NYS-12 has a single survey unit.}} | ISOCS scan data or a data summary was identified for the other three (3) survey units. | ||
The staff cannot locate scan survey data for NYS-12-01 in the report or attachments. NYS-12 has a single survey unit.}} |
Latest revision as of 11:32, 23 November 2019
ML063410404 | |
Person / Time | |
---|---|
Site: | Yankee Rowe |
Issue date: | 09/05/2006 |
From: | John Hickman NRC/FSME/DWMEP |
To: | Carson A Yankee Atomic Electric Co |
References | |
Download: ML063410404 (3) | |
Text
_John Hickaman_-_FS Data Issues ... .Page,1 From: John Hickman To: Yankee, Alice Carson Date: 09/05/2006 4:29:56 PM
Subject:
FSS Data Issues Alice, The following are the data issues that Tom needs resolved:
TBN-01 -02 through TBN-01 -08 (1) Systematic Survey Data Table 10 provides the survey design and indicates that all are Class 1 survey units. The survey design or Section 5.2.1.4 narrative indicates that 15 fixed-point samples will be taken in each survey unit. Table 13 provides the systematic survey data, but the results are in cpm. Table 11 provides the DCGL-w, DCGL-EMC and Investigation levels as dpm/100cm2 units. The staff cannot determine if the DCGLs are exceeded or not.
(2) Scan Survey Data The staff cannot identify the scan survey data for these survey units in the FSS Report or attachments.
NOL-01 -01 and NYS-12-01 The FSS Reports listed are both MARSSIM class 1 survey units, and require both systematic surveys and scan surveys.
The staff cannot locate the scan survey data for NOL-01-01. NOL-01 has four (4) survey units. ISOCS scan data or a data summary was identified for the other three (3) survey units.
The staff cannot locate scan survey data for NYS-12-01 in the report or attachments. NYS-12 has a single survey unit.
I also attached a WP copy of the same text.
Thanks John CC: Thomas Youngblood
Ic:\temp\GWJ00001.TMP V Page I Page I.6:\ten~NOW}dOOO1 .TMP Mail Envelope Properties (44FDDE44.17E:12: 35218)
Subject:
FSS Data Issues Creation Date 09/05/2006 4:29:56 PM From: John Hickman Created By-: JBH@nrc.*ov Recipients Action Date & Time comcast.net Transferred 09/05/2006 4:30:20 PM acarson1967 (Yankee Alice Carson) nrc.gov TWGWPO04.HQGWDOO1 Delivered 09/05/2006 4:30:06 PM THY CC (Thomas Youngblood) Opened 09/05/2006 4:31:33 PM Post Office Delivered Route comcast.net TWGWPO04.HQGWDOO1 09/05/2006 4:30:06 PM nrc.gov Files Size Date & Time MESSAGE 2121 09/05/2006 4:29:56 PM Data issues.wpd 3513 09/05/2006 4:27:16 PM Options Auto Delete: No Expiration Date: N4one Notify Recipients: Yes Priority: Standard ReplyRequested: No Return Notification:
Send Notification when Opened Concealed
Subject:
No Security: tandard To Be Delivered: Immediate Status Tracking: I)elivered & Opened
Ij6hn Hickman - Data- issues.wpd .. Pagel TBN-01 -02 throuqh TBN-01 -08 (1) Systematic Survey Data Table 10 provides the survey design and indicates that all are Class 1 survey units. The survey design or Section 5.2.1.4 narrative indicates that 15 fixed-point samples will be taken in each survey unit. Table 13 provides the systematic survey data, but the results are in cpm. Table 11 provides the DCGL-w, DCGL-EMC and Investigation levels as dpm/1 00cm 2 units. The staff cannot determine if the DCGLs are exceeded or not.
(2) Scan Survey Data The staff cannot identify the scan survey data for these survey units in the FSS Report or attachments.
NOL-01 -01 and NYS-12-01 The FSS Reports Iisted are both MARSSIM class 1 survey units, and require both systematic surveys and scan surveys.
The staff cannot locate the scan survey data for NOL-01 -01. NOL-01 has four (4) survey units.
ISOCS scan data or a data summary was identified for the other three (3) survey units.
The staff cannot locate scan survey data for NYS-12-01 in the report or attachments. NYS-12 has a single survey unit.