ML063410404

From kanterella
Jump to navigation Jump to search
E-mail Dated September 5, 2006, to Yankee Atomic Electric Company Forwarding Comments on Final Status Survey Reports
ML063410404
Person / Time
Site: Yankee Rowe
Issue date: 09/05/2006
From: John Hickman
NRC/FSME/DWMEP
To: Carson A
Yankee Atomic Electric Co
References
Download: ML063410404 (3)


Text

_John Hickaman_-_FS Data Issues ... .Page,1 From: John Hickman To: Yankee, Alice Carson Date: 09/05/2006 4:29:56 PM

Subject:

FSS Data Issues Alice, The following are the data issues that Tom needs resolved:

TBN-01 -02 through TBN-01 -08 (1) Systematic Survey Data Table 10 provides the survey design and indicates that all are Class 1 survey units. The survey design or Section 5.2.1.4 narrative indicates that 15 fixed-point samples will be taken in each survey unit. Table 13 provides the systematic survey data, but the results are in cpm. Table 11 provides the DCGL-w, DCGL-EMC and Investigation levels as dpm/100cm2 units. The staff cannot determine if the DCGLs are exceeded or not.

(2) Scan Survey Data The staff cannot identify the scan survey data for these survey units in the FSS Report or attachments.

NOL-01 -01 and NYS-12-01 The FSS Reports listed are both MARSSIM class 1 survey units, and require both systematic surveys and scan surveys.

The staff cannot locate the scan survey data for NOL-01-01. NOL-01 has four (4) survey units. ISOCS scan data or a data summary was identified for the other three (3) survey units.

The staff cannot locate scan survey data for NYS-12-01 in the report or attachments. NYS-12 has a single survey unit.

I also attached a WP copy of the same text.

Thanks John CC: Thomas Youngblood

Ic:\temp\GWJ00001.TMP V Page I Page I.6:\ten~NOW}dOOO1 .TMP Mail Envelope Properties (44FDDE44.17E:12: 35218)

Subject:

FSS Data Issues Creation Date 09/05/2006 4:29:56 PM From: John Hickman Created By-: JBH@nrc.*ov Recipients Action Date & Time comcast.net Transferred 09/05/2006 4:30:20 PM acarson1967 (Yankee Alice Carson) nrc.gov TWGWPO04.HQGWDOO1 Delivered 09/05/2006 4:30:06 PM THY CC (Thomas Youngblood) Opened 09/05/2006 4:31:33 PM Post Office Delivered Route comcast.net TWGWPO04.HQGWDOO1 09/05/2006 4:30:06 PM nrc.gov Files Size Date & Time MESSAGE 2121 09/05/2006 4:29:56 PM Data issues.wpd 3513 09/05/2006 4:27:16 PM Options Auto Delete: No Expiration Date: N4one Notify Recipients: Yes Priority: Standard ReplyRequested: No Return Notification:

Send Notification when Opened Concealed

Subject:

No Security: tandard To Be Delivered: Immediate Status Tracking: I)elivered & Opened

Ij6hn Hickman - Data- issues.wpd .. Pagel TBN-01 -02 throuqh TBN-01 -08 (1) Systematic Survey Data Table 10 provides the survey design and indicates that all are Class 1 survey units. The survey design or Section 5.2.1.4 narrative indicates that 15 fixed-point samples will be taken in each survey unit. Table 13 provides the systematic survey data, but the results are in cpm. Table 11 provides the DCGL-w, DCGL-EMC and Investigation levels as dpm/1 00cm 2 units. The staff cannot determine if the DCGLs are exceeded or not.

(2) Scan Survey Data The staff cannot identify the scan survey data for these survey units in the FSS Report or attachments.

NOL-01 -01 and NYS-12-01 The FSS Reports Iisted are both MARSSIM class 1 survey units, and require both systematic surveys and scan surveys.

The staff cannot locate the scan survey data for NOL-01 -01. NOL-01 has four (4) survey units.

ISOCS scan data or a data summary was identified for the other three (3) survey units.

The staff cannot locate scan survey data for NYS-12-01 in the report or attachments. NYS-12 has a single survey unit.