LJohin Hikman - Summary Comments on Yankee Rowe 00L-12 & 00L-14 Final Status Survey Reports Page 1 From: John Hickman To: Yankee, Alice Carson Date: 12/20/2006 3:41:55 PM

Subject:

Summary Comments on Yankee Rowe OOL-12 & OOL-14 Final Status Survey Reports Alice, My bad on these. Tom gave me these comments about a month ago and I lost track. Please address when you get a chance.

Thanks, John, OOL-12 Observations/Comments:

FSS Report Appendix A - Final Status Survey Planning Worksheets - indicates that after a boundary modification, two bias samples that had been taken were considered to be outside the survey unit. This information is different from the information in Section 5.4 - Survey Results - which indicates that two samples (OOL-12-021 & OOL-12-022) were taken as bias samples & are not listed in the results table.

This situation could confuse some readers. Please clarify OOL-14 Observations/comments:

No information on gamma survey/scan results were provided in Section 5.4 - Survey Results or in Section 6.0 - Conclusions. OOL-1 4-01 is a class 3 soil area, and the Yankee Rowe LTP, Rev. 1, specifies judgmental gamma surveys/scans. It appears that some judgmental surveys were made, but the results are not given. Please address.

gjývým 6q mri- Pag~ JI Ic:\temp\GW}OOOO1.TMP

[

Mail Envelope Properties (4589A013.6CB : 12: 35218)

Subject:

Summary Comments on Yankee Rowe OOL-12 & OOL-14 Final Status Survey Reports Creation Date 12/20/2006 3:41:55 PM From: John Hickman Created By: JBH@nrc.gov Recipients Action Date & Time comcast.net Transferred 12/20/2006 3:42:10 PM acarson1967 (Yankee Alice Carson)

Post Office Delivered Route comcast.net Files Size Date & Time MESSAGE 2059 12/20/2006 3:41:55 PM Options Auto Delete: N4o Expiration Date: None Notify Recipients: Yes Priority: Standard ReplyRequested: N4o Return Notification:

Send Notification when Opened Concealed

Subject:

Security: Standard To Be Delivered: mmediate Status Tracking: IDelivered & Opened