[John Hickman - RE: Summary Comments on Yankee Rowe OOL-12 & OOL-14 Final Status Survey Reports
.Pag 1]
From:
"Alice Carson" <acarsonl967@comcast.net>.
To:
"'John Hickman"' <JBH@nrc.gov>, <thy@nrc.gov>
Date:
12/27/2006 11:10:57 AM
Subject:
RE: Summary Comments on Yankee Rowe OOL-12 & OOL-14 Final Status Survey Reports John/Tom, It was just brought to my attention that there was a typographical error in Section 5.1.4 of the FSSR for OOL-14. The report, and the quote from the report included in the response provided to you earlier this morning, erroneously reference OOL-14-04, instead of OOL-14-01. The attached response has been revised to acknowledge this error.
Alice Carson
Original Message -----
From: Alice Carson [1]
Sent: Wednesday, December 27, 2006 10:47 AM To: 'John Hickman'; 'thy@nrc.gov' Cc: 'Greg Babineau'; 'Marty Erickson'; 'Joe Bourassa'; 'Gerard P. Van Noordennen'
Subject:
RE: Summary Comments on Yankee Rowe OOL-12 & OOL-14 Final Status Survey Reports John/Tom, Attached are responses to the questions/comments on OOL-12 and OOL-14, which were previously provided to Yankee via email on 12/20/06. If you have any questions, please give me a call.
Alice Carson OOL-12 Observations/Comments:
FSS Report Appendix A - Final Status Survey Planning Worksheets - indicates that after a boundary modification, two bias samples that had been taken were considered to be outside the survey unit. This information is different from the information in Section 5.4 - Survey Results - which indicates that two samples (OOL-12-021 & OOL-12-022) were taken as bias samples & are not listed in the results table. This situation could confuse some readers.
Please clarify OOL-14 Observations/comments:
No information on gamma survey/scan results were provided in Section 5.4 -
Survey Results or in Section 6.0 - Conclusions. OOL-1 4-01 is a class 3 soil area, and the Yankee Rowe LTP, Rev. 1, specifies judgmental gamma surveys/scans. It appears that some judgmental surveys were made, but the results are not given. Please address.
CC:
"'Greg Babineau'" <Babineau @yankeerowe.com>, "'Marty Erickson"'
<erickson @yankeerowe.com>, "'Joe Bourassa-' <Bourassa@CYAPCO.com>, "'Gerard P. Van Noordennen'" WVanNoordennen @ CYAPCO.com>
IFC -Xt-6 jn-pýT-W)76MO -1. TM 0-
[~\\temp\\GWYoOYt1~TMP Pane i~t Mail Envelope Properties (45929B02.B15 :14 : 47893)
Subject:
Status Survey Reports Creation Date From:
RE: Summary Comments on Yankee Rowe OOL-12 & OOL-14 Final 12/27/2006 11:10:23 AM
'Alice Carson" <acarson 1967 @comcast.net>
Created By:
acarson 1967@comcast.net Recipients nrc.gov OWGWPO04.HQGWDO01 JBH (John Hickman) nrc.gov TWGWPO04.HQGWDOO1 THY (Thomas Youngblood)
CYAPCO.com VanNoordennen CC ('Gerard P. Van Noordennen')
Bourassa CC ('Joe Bourassa')
yankeerowe.com erickson CC ('Marty Erickson')
Babineau CC ('Greg Babineau')
Post Office OWGWPO04.HQGWDO01 TWGWPO04.HQGWDO01 Route nrc.gov nrc.gov CYAPCO.com yankeerowe.com Files Size Date & Time MESSAGE 1773 12/27/2006 11:10:23 AM Responses to 12-20 questions on OOL-12_andOOL-14.pdf 7955 Mime.822 15679 Options Expiration Date:
Priority:
ReplyRequested:
Return Notification:
Concealed
Subject:
None Standard No None No
Icmp\\GW}dO-OOI.T-M-P Page2_
Security:
Standard Junk Mail Handling Evaluation Results Message is eligible for Junk Mail handling This message was not classified as Junk Mail Junk Mail settings when this message was delivered Junk Mail handling disabled by User Junk Mail handling disabled by Administrator Junk List is not enabled Junk Mail using personal address books is not enabled Block List is not enabled
NRC Summary Comments on Yankee Rowe OOL-12 & OOL-14 Final Status Survey Reports (Email from Hickman to Carson dated 12/20/2006)
OOL-12 Observations/Comments:
NRC Comment: FSS Report Appendix A - Final Status Survey Planning Worksheets -
indicates that after a boundary modification, two bias samples that had been taken were considered to be outside the survey unit. This information is different from the information in Section 5.4 - Survey Results - which indicates that two samples (OOL 021 & OOL-12-022) were taken as bias samples & are not listed in the results table. This situation could confuse some readers. Please clarify Yankee Response: Two (2) samples, OOL-12-021 and OOL-12-022, were originally taken as biased samples for the subject survey unit; however, they subsequently fell outside the survey unit, after a survey unit boundary modification and, therefore, were omittedfrom the table. The last sentence of the first paragraph in Section 5.4 should read: "Samples OOL-12-021 and OOL-12-022 were originally collected as biased samples for OOL-12; however, after a boundary modification of the Unit, the samples were found to lie outside of the survey unit, and therefore they are omitted from inclusion in OOL-12."
OOL-14 Observations/Comments:
NRC Comment: No information on gamma survey/scan results were provided in Section 5.4 -Survey Results or in Section 6.0 - Conclusions. OOL-14-01 is a class 3 soil area, and the Yankee Rowe LTP, Rev. 1, specifies judgmental gamma surveys/scans. It appears that some judgmental surveys were made, but the results are not given. Please address.
Yankee Response: Judgmental scans were performed in the Survey Unit. The results are addressed in Section 5.1.4: "OOL-14-O1 was scanned approximately 10% with a SPA-3.
No activity greater than background or DCGLw, attributable to plant radionuclides, was present in OOL-14-[01]. " In subsequent reports Yankee addressed results of the SPA-3 scans in Section 5.4 of the report.