ML110030794: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
(3 intermediate revisions by the same user not shown)
Line 3: Line 3:
| issue date = 08/26/2010
| issue date = 08/26/2010
| title = 2010 Fermi Initial License Examination ES-401-4
| title = 2010 Fermi Initial License Examination ES-401-4
| author name = Reeser D W
| author name = Reeser D
| author affiliation = NRC/RGN-III/DRS/OB
| author affiliation = NRC/RGN-III/DRS/OB
| addressee name =  
| addressee name =  
Line 16: Line 16:


=Text=
=Text=
{{#Wiki_filter:}}
{{#Wiki_filter:ES-401                        Record of Rejected K/As                        Form ES-401-4 Facility: Fermi 2 (50-341)  Date of Exam: Aug/Sept 2010 Tier /      Randomly      Reason for Rejection Group        Selected K/A 2/1          223002.K5      No K/A statements listed in K/A category. Randomly selected another category (A1) 2/2          201003.K2      No K/A statements listed in K/A category. Randomly selected another category (A2) 1/1          295018 AK3.05  Replaced AK3.05 with randomly selected AK3.02 because Fermi 2 operates both RBCCW heat exchangers in-service due to heat exchangers being undersize, therefore there is no standby heat exchanger. (4/9/2010) 1/1          295018 AK3.02  Reactor power reduction (except for reactor scram on loss of cooling) is not an expected response due to system capabilities. Randomly selected AK3.07 as replacement.
(4/9/2010) 1/1          600000 AK1.01  Replaced by AK1.02 (only other subcategory in the K1 category) due to unable to write question at an appropriate level of difficulty. (4/16/2010) 2/2          216000 A2.06  Due to redundancy in power supplies, unable to write a question with a reasonable power supply failure. Replaced with randomly selected A2.10 (05/22/2010) 2/2          272000 A2.05  Replaced by A2.01 since there is no dilution steam at Fermi.
(SRO)                      (05/28/2010) 2/2          288000        System replaced with 290003 to provide a focus more (SRO)                      applicable to an SRO. Generic K/A was not changed.
(05/28/2010) 2/1          217000 K2.01  Revised to reflect actual wording and importance rating in KA Catalog. [Motor Operated Valves - IR=2.8] (06/14/2010) 1/2          295033 EK3.05  Emergency Plan bases is SRO level knowledge. Randomly selected EK3.02 [Reactor Scram - IR=3.5] as replacement.
(06/15/2010) 2/1          218000 K4.02  Fermi has no manual initiation feature for ADS. Randomly selected K4.03 [ADS Logic Control - IR=3.8] as replacement.
(06/16/2010) 2/1          215004 G2.4.8  Replaced with randomly selected G2.2.44. Unable to write an appropriate question for the originally selected K/A.
(7/20/2010) 2/1          215004 A1.05  Replaced with randomly selected A1.06. Original K/A not applicable to facility. (7/20/2010) 2/1          215003 G2.4.18 Replaced with 2.2.40. Unable to write question for original (SRO)                      K/A at an appropriate level of difficulty (7/20/2010) 3 (RO)      2.1.9          ROs do not direct activities within the Main Control Room; that is an SRO function. Replaced with 2.1.14 (7/20/2010) 3 (RO)      2.1.34        Knowledge not required to be committed to memory.
Replaced with 2.1.21. (7/20/2010) 3 (RO)      2.1.21        Unable to locate a suitable reference to support a question associated with K/A. Replaced with 2.1.32. (7/21/2010)
 
Facility: Fermi 2 (50-341)  Date of Exam: Aug/Sept 2010 Tier /      Randomly      Reason for Rejection Group        Selected K/A 2/1          215005 K2.02  Unable to write a question of sufficient difficulty that was not to similar to question on SRO exam. Replaced K/A category with K5 (balances Tier 2/Group 1 numbers). Randomly selected K5.05. (7/29/2010)}}

Latest revision as of 05:57, 13 November 2019

2010 Fermi Initial License Examination ES-401-4
ML110030794
Person / Time
Site: Fermi DTE Energy icon.png
Issue date: 08/26/2010
From: David Reeser
Operations Branch III
To:
Detroit Edison
References
ES-401-4, 50-341/10-301
Download: ML110030794 (2)


Text

ES-401 Record of Rejected K/As Form ES-401-4 Facility: Fermi 2 (50-341) Date of Exam: Aug/Sept 2010 Tier / Randomly Reason for Rejection Group Selected K/A 2/1 223002.K5 No K/A statements listed in K/A category. Randomly selected another category (A1) 2/2 201003.K2 No K/A statements listed in K/A category. Randomly selected another category (A2) 1/1 295018 AK3.05 Replaced AK3.05 with randomly selected AK3.02 because Fermi 2 operates both RBCCW heat exchangers in-service due to heat exchangers being undersize, therefore there is no standby heat exchanger. (4/9/2010) 1/1 295018 AK3.02 Reactor power reduction (except for reactor scram on loss of cooling) is not an expected response due to system capabilities. Randomly selected AK3.07 as replacement.

(4/9/2010) 1/1 600000 AK1.01 Replaced by AK1.02 (only other subcategory in the K1 category) due to unable to write question at an appropriate level of difficulty. (4/16/2010) 2/2 216000 A2.06 Due to redundancy in power supplies, unable to write a question with a reasonable power supply failure. Replaced with randomly selected A2.10 (05/22/2010) 2/2 272000 A2.05 Replaced by A2.01 since there is no dilution steam at Fermi.

(SRO) (05/28/2010) 2/2 288000 System replaced with 290003 to provide a focus more (SRO) applicable to an SRO. Generic K/A was not changed.

(05/28/2010) 2/1 217000 K2.01 Revised to reflect actual wording and importance rating in KA Catalog. [Motor Operated Valves - IR=2.8] (06/14/2010) 1/2 295033 EK3.05 Emergency Plan bases is SRO level knowledge. Randomly selected EK3.02 [Reactor Scram - IR=3.5] as replacement.

(06/15/2010) 2/1 218000 K4.02 Fermi has no manual initiation feature for ADS. Randomly selected K4.03 [ADS Logic Control - IR=3.8] as replacement.

(06/16/2010) 2/1 215004 G2.4.8 Replaced with randomly selected G2.2.44. Unable to write an appropriate question for the originally selected K/A.

(7/20/2010) 2/1 215004 A1.05 Replaced with randomly selected A1.06. Original K/A not applicable to facility. (7/20/2010) 2/1 215003 G2.4.18 Replaced with 2.2.40. Unable to write question for original (SRO) K/A at an appropriate level of difficulty (7/20/2010) 3 (RO) 2.1.9 ROs do not direct activities within the Main Control Room; that is an SRO function. Replaced with 2.1.14 (7/20/2010) 3 (RO) 2.1.34 Knowledge not required to be committed to memory.

Replaced with 2.1.21. (7/20/2010) 3 (RO) 2.1.21 Unable to locate a suitable reference to support a question associated with K/A. Replaced with 2.1.32. (7/21/2010)

Facility: Fermi 2 (50-341) Date of Exam: Aug/Sept 2010 Tier / Randomly Reason for Rejection Group Selected K/A 2/1 215005 K2.02 Unable to write a question of sufficient difficulty that was not to similar to question on SRO exam. Replaced K/A category with K5 (balances Tier 2/Group 1 numbers). Randomly selected K5.05. (7/29/2010)