{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION REGION III 2443 WARRENVILLE ROAD, SUITE 210 LISLE, IL 60532
{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION REGION III 2443 WARRENVILLE ROAD, SUITE 210 LISLE, IL 60532-4352 August 19, 2013 EA-13-171 Mr. Larry Weber Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106
-4352   August 19, 2013 EA-13-171 Mr. Larry Weber Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company Nuclear Generation Group
 
One Cook Place Bridgman, MI 49106


==SUBJECT:==
==SUBJECT:==
DONALD C. COOK NUCLEAR POWER PLANT, UNITS 1 AND 2 ACKNOWLEDGMENT OF TWO DISPUTED VIOLATIONS NRC INSPECTION REPORT 05000315/2013010
DONALD C. COOK NUCLEAR POWER PLANT, UNITS 1 AND 2 ACKNOWLEDGMENT OF TWO DISPUTED VIOLATIONS NRC INSPECTION REPORT 05000315/2013010; 05000316/2013010
; 05000316/2013010


==Dear Mr. Weber:==
==Dear Mr. Weber:==


This letter acknowledg e s your lette r sent t o the U.S. Nuclear Regulatory Commission (NRC), dated August 2 , 201 3 , that provide d a response to o ur inspecti o n report iss u ed on July 8 , 2013, concerning a ctivities conducted a t your Donald C. Cook Nuclear Power Plant, Units 1 and 2. The letter we received c ontested two N on-Cited Violation s (NCV s) documented in the D. C. Cook ins pection repor t 2013 010. The cont e sted NCVs are: 05000315/201 3 010-01; 05000316/2013010
This letter acknowledges your letter sent to the U.S. Nuclear Regulatory Commission (NRC),
-01 , "Failure to Maintain Emergency Operating Procedures for Mitigating the consequences of a SGTR [steam generator tube rupture
dated August 2, 2013, that provided a response to our inspection report issued on July 8, 2013, concerning activities conducted at your Donald C. Cook Nuclear Power Plant, Units 1 and 2. The letter we received contested two Non-Cited Violations (NCVs) documented in the D. C. Cook inspection report 2013 010. The contested NCVs are: 05000315/2013010-01; 05000316/2013010-01, Failure to Maintain Emergency Operating Procedures for Mitigating the consequences of a SGTR [steam generator tube rupture] per TS [Technical Specification] Section 5.4.1, Procedures, and 05000315/2013010-02; 05000316/2013010-02, Failure to Enter the Limiting Condition for Operations and Perform Required Actions per TS 3.7.4, SG [steam generator] PORVs [power operated relief valves].
] per TS [Technical Specification
We are currently reviewing your basis for contesting the above NCVs. The NRC seeks to be thorough and timely in the review of licensee responses. Accordingly, we will inform you as soon as we complete our evaluation.
] Section 5.4.1, 'Procedures'
 
," and 05000315/201 3 010-02; 05000316/2013010
L. Weber                                        In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records System (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS), accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
-02, "Failure to Enter the Limiting Condition for Operations and Perform Required Actions per TS 3.7.4, 'SG
Sincerely,
[steam generator]
                                                /RA/
PORVs [power operated relief valves]
Benny Jose, Acting Chief Engineering Branch 2 Division of Reactor Safety Docket Nos. 50-315; 50-316 License Nos. DPR-58; DPR-74 cc: Distribution via ListServ'
.'"  We are currently review i ng your basis for contesting the above NCVs. The NRC seeks to be thorough and timely in the review of licensee r esponses. Accordingly, we will inform you as soon as we complete our evaluation.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this let t er will be available electronically for public inspection in the NRC Public Document Room or fr o m the Publicly Av ailable Reco r ds System (PARS) c omponent of NRC's Agencywide Doc uments Access and Manageme n t System (ADAMS), accessible from the NRC Website at http://www.
nrc.gov/reading
-rm/adams.html (the Public Elect ronic Readi n g Room). Sincerely , /RA/   Benny Jose
, Acting Chief Engineering Branch 2 Division of Reactor Safety Docket Nos. 50
-315; 50-316 License Nos. DPR
-58; DPR-74 cc: Distrib ution via List ServŽ In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this let t er will be available electronically for public inspection in th e NRC Public Document Room or fr o m the Publicly Av ailable Reco r ds System (PARS) c omponent of NRC's Agencywide Doc uments Access and Manageme n t System (ADAMS), accessible from the NRC Website at http://www.
nrc.gov/reading
-rm/adams.html (the Public Elect ronic Readi n g Room). Sincerely,  /RA/  Benny Jose
, Acting Chief Engineering Branch 2 Division of Reactor Safety Docket Nos. 50
-315; 50-316 License Nos. DPR
-58; DPR-74 cc: Distrib ution via List ServŽ DISTRIBUTION
: Vivian Campbell RidsNrrDorlLpl3
-1 Resource RidsNrrPMDCCook Resource RidsNrrDirsIrib Resource Cynthia Pederson Anne Boland Steven Orth Allan Barker Carole Ariano Linda Linn DRPIII DRSIII Patricia Buckley Tammy Tomczak ROPreports.Resource@nrc.gov


See previous concurrence page DOCUMENT NAME: Ltr 8 19 13 Acknowledgement Letter  
L. Weber                                                                  In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records System (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS), accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).
- D. C. Cook Publicly Available Non-Publicly Available Sensitive Non-Sensitive To receive a copy of this document, indicate in the concurrence box "C" = Copy without attach/encl "E" = Copy with attach/encl "N" = No copy OFFICE RIII RIII RIII     NAME CTilton:ls S Orth BJose   DATE 08/19/13 08/19/13 08/19/13   OFFICIAL RECORD COPY}}
Sincerely,
                                                                          /RA/
Benny Jose, Acting Chief Engineering Branch 2 Division of Reactor Safety Docket Nos. 50-315; 50-316 License Nos. DPR-58; DPR-74 cc: Distribution via ListServ' DISTRIBUTION:
Vivian Campbell RidsNrrDorlLpl3-1 Resource RidsNrrPMDCCook Resource RidsNrrDirsIrib Resource Cynthia Pederson Anne Boland Steven Orth Allan Barker Carole Ariano Linda Linn DRPIII DRSIII Patricia Buckley Tammy Tomczak ROPreports.Resource@nrc.gov See previous concurrence page DOCUMENT NAME: Ltr 81913 Acknowledgement Letter - D. C. Cook Publicly Available                           Non-Publicly Available                             Sensitive                   Non-Sensitive To receive a copy of this document, indicate in the concurrence box "C" = Copy without attach/encl "E" = Copy with attach/encl "N" = No copy OFFICE                 RIII                       RIII                     RIII NAME                   CTilton:ls                 SOrth                    BJose DATE                   08/19/13                   08/19/13                 08/19/13 OFFICIAL RECORD COPY}}

Latest revision as of 15:31, 4 November 2019

Ltr 8/19/13 Dccook Acknowledgement of Disputed Violations
ML13233A132
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 08/19/2013
From: Benny Jose
NRC/RGN-III/DRS/EB2
To: Weber L
Indiana Michigan Power Co
Caroline Tilton
References
ea-13-171 IR-13-010
Download: ML13233A132 (3)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION REGION III 2443 WARRENVILLE ROAD, SUITE 210 LISLE, IL 60532-4352 August 19, 2013 EA-13-171 Mr. Larry Weber Senior Vice President and Chief Nuclear Officer Indiana Michigan Power Company Nuclear Generation Group One Cook Place Bridgman, MI 49106

SUBJECT:

DONALD C. COOK NUCLEAR POWER PLANT, UNITS 1 AND 2 ACKNOWLEDGMENT OF TWO DISPUTED VIOLATIONS NRC INSPECTION REPORT 05000315/2013010; 05000316/2013010

Dear Mr. Weber:

This letter acknowledges your letter sent to the U.S. Nuclear Regulatory Commission (NRC),

dated August 2, 2013, that provided a response to our inspection report issued on July 8, 2013, concerning activities conducted at your Donald C. Cook Nuclear Power Plant, Units 1 and 2. The letter we received contested two Non-Cited Violations (NCVs) documented in the D. C. Cook inspection report 2013 010. The contested NCVs are: 05000315/2013010-01; 05000316/2013010-01, Failure to Maintain Emergency Operating Procedures for Mitigating the consequences of a SGTR [steam generator tube rupture] per TS [Technical Specification] Section 5.4.1, Procedures, and 05000315/2013010-02; 05000316/2013010-02, Failure to Enter the Limiting Condition for Operations and Perform Required Actions per TS 3.7.4, SG [steam generator] PORVs [power operated relief valves].

We are currently reviewing your basis for contesting the above NCVs. The NRC seeks to be thorough and timely in the review of licensee responses. Accordingly, we will inform you as soon as we complete our evaluation.

L. Weber In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records System (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS), accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/

Benny Jose, Acting Chief Engineering Branch 2 Division of Reactor Safety Docket Nos. 50-315; 50-316 License Nos. DPR-58; DPR-74 cc: Distribution via ListServ'

L. Weber In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records System (PARS) component of NRC's Agencywide Documents Access and Management System (ADAMS), accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/

Benny Jose, Acting Chief Engineering Branch 2 Division of Reactor Safety Docket Nos. 50-315; 50-316 License Nos. DPR-58; DPR-74 cc: Distribution via ListServ' DISTRIBUTION:

Vivian Campbell RidsNrrDorlLpl3-1 Resource RidsNrrPMDCCook Resource RidsNrrDirsIrib Resource Cynthia Pederson Anne Boland Steven Orth Allan Barker Carole Ariano Linda Linn DRPIII DRSIII Patricia Buckley Tammy Tomczak ROPreports.Resource@nrc.gov See previous concurrence page DOCUMENT NAME: Ltr 81913 Acknowledgement Letter - D. C. Cook Publicly Available Non-Publicly Available Sensitive Non-Sensitive To receive a copy of this document, indicate in the concurrence box "C" = Copy without attach/encl "E" = Copy with attach/encl "N" = No copy OFFICE RIII RIII RIII NAME CTilton:ls SOrth BJose DATE 08/19/13 08/19/13 08/19/13 OFFICIAL RECORD COPY