Line 3: Line 3:
| issue date = 06/27/1995
| issue date = 06/27/1995
| title = Comment on Proposed GL Re Relocation of Pressure Temperature Limit Curves & Low Temperature Overpressure Protection Sys Limits.Supports Issuance of Ltr
| title = Comment on Proposed GL Re Relocation of Pressure Temperature Limit Curves & Low Temperature Overpressure Protection Sys Limits.Supports Issuance of Ltr
| author name = VINCENT R A
| author name = Vincent R
| author affiliation = CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.),
| author affiliation = CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.),
| addressee name =  
| addressee name =  
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:( \
{{#Wiki_filter:consumers
* consumers Power POWERING /IAICHIGAN"S PROGRESS Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert. Ml 49043 June 27, 1995 Chief, Rules Review and Directives Branch U S Nuclear Regulatory Commission Washington, DC 20555
                                    *
* 1995 JUN 30 PM S: QB RULES REViEW & om. BR. USNRC 29fX£ cl) 0;4q5 COMMENTS ON PROPOSED GENERIC LETTER; RELOCATION OF THE PRESSURE TEMPERATURE LIMIT CURVES AND LOW TEMPERATURE OVERPRESSURE PROTECTION SYSTEM LIMITS Consumers Power Company's Palisades Plant has reviewed the proposed generic letter on the relocation of the pressure temperature (P/T) limit curves and low temperature overpressure protection (LTOP) system limits from the Technical Specifications and offers the following comments.
* 9 1~CEnJED Power                                                   1995 JUN 30 PM S: QB POWERING
The relocation of the P/T and LTOP system limits from the technical specifications will allow licensees to more efficiently and cost effectively maintain these parameters.
    /IAICHIGAN"S PROGRESS                                                       RULES REViEW &  om. BR.
The requirement for developing the limits with NRC approved methodology still assures that the health and safety of the public is preserved.
Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert. Ml 49043 USNRC
This proposed generic letter and its voluntary recommendation meet the needs of both the regulator and licensee.
                                                                                      ~Q__ 29fX£ cl) 0;4q5 June 27, 1995 Chief, Rules Review and Directives Branch U S Nuclear Regulatory Commission Washington, DC 20555 COMMENTS ON PROPOSED GENERIC LETTER; RELOCATION OF THE PRESSURE TEMPERATURE LIMIT CURVES AND LOW TEMPERATURE OVERPRESSURE PROTECTION SYSTEM LIMITS Consumers Power Company's Palisades Plant has reviewed the proposed generic letter on the relocation of the pressure temperature (P/T) limit curves and low temperature overpressure protection (LTOP) system limits from the Technical Specifications and offers the following comments. The relocation of the P/T and LTOP system limits from the technical specifications will allow licensees to more efficiently and cost effectively maintain these parameters.
Therefore, the Palisades Plant supports the issuance of this proposed generic letter. Licensing Administrator cc KMHaas MAH95*033 9507060006 950627
The requirement for developing the limits with NRC approved methodology still assures that the health and safety of the public is preserved. This proposed generic letter and its voluntary recommendation meet the needs of both the regulator and licensee. Therefore, the Palisades Plant supports the issuance of this proposed generic letter.
* I PDR I&E . , i MISC PDR 1 050020 A CMS' ENERGY COMPANY}}
Licensing Administrator
(
  \
cc KMHaas MAH95*033 9507060006 950627
* I PDR     I&E                   . , i MISC                         PDR ~ 1 050020 A CMS' ENERGY COMPANY}}

Latest revision as of 18:20, 21 October 2019

Comment on Proposed GL Re Relocation of Pressure Temperature Limit Curves & Low Temperature Overpressure Protection Sys Limits.Supports Issuance of Ltr
ML18064A820
Person / Time
Site: Palisades Entergy icon.png
Issue date: 06/27/1995
From: Vincent R
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC
References
FRN-60FR28805 60FR28805-00002, 60FR28805-2, NUDOCS 9507060006
Download: ML18064A820 (1)


Text

consumers

  • 9 1~CEnJED Power 1995 JUN 30 PM S: QB POWERING

/IAICHIGAN"S PROGRESS RULES REViEW & om. BR.

Palisades Nuclear Plant: 27780 Blue Star Memorial Highway, Covert. Ml 49043 USNRC

~Q__ 29fX£ cl) 0;4q5 June 27, 1995 Chief, Rules Review and Directives Branch U S Nuclear Regulatory Commission Washington, DC 20555 COMMENTS ON PROPOSED GENERIC LETTER; RELOCATION OF THE PRESSURE TEMPERATURE LIMIT CURVES AND LOW TEMPERATURE OVERPRESSURE PROTECTION SYSTEM LIMITS Consumers Power Company's Palisades Plant has reviewed the proposed generic letter on the relocation of the pressure temperature (P/T) limit curves and low temperature overpressure protection (LTOP) system limits from the Technical Specifications and offers the following comments. The relocation of the P/T and LTOP system limits from the technical specifications will allow licensees to more efficiently and cost effectively maintain these parameters.

The requirement for developing the limits with NRC approved methodology still assures that the health and safety of the public is preserved. This proposed generic letter and its voluntary recommendation meet the needs of both the regulator and licensee. Therefore, the Palisades Plant supports the issuance of this proposed generic letter.

Licensing Administrator

(

\

cc KMHaas MAH95*033 9507060006 950627

  • I PDR I&E . , i MISC PDR ~ 1 050020 A CMS' ENERGY COMPANY