U-603857, 90-Day Post-Outage Inservice Inspection (ISI) Summary Report

From kanterella
Jump to navigation Jump to search
90-Day Post-Outage Inservice Inspection (ISI) Summary Report
ML081330015
Person / Time
Site: Clinton Constellation icon.png
Issue date: 05/05/2008
From: Gackstetter S
AmerGen Energy Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
U-603857
Download: ML081330015 (90)


Text

An Exelon Company Clinton Power Station R. R. 3, Box 228 Clinton, IL 61727 10 CFR 50.55a(g)

U-603857 May 5, 2008 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Clinton Power Station, Unit 1 Facility Operating License No. NPF-62 NRC Docket No. 50-461

Subject:

90-Day Post-Outage Inservice Inspection (ISI) Summary Report In accordance with 10 CFR 50.55a, "Codes and standards," paragraph (g), "Inservice inspection requirements," AmerGen Energy Company, LLC (AmerGen) is required to maintain an Inservice Inspection Program in accordance with the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code. Please find enclosed the Post-Outage (90-Day) ISI Summary Report for Clinton Power Station, Unit 1, for examinations and repair/replacement activities performed between February 26, 2006 (i.e.,

the end of the 1 0 th refueling outage) and February 5, 2008 (i.e., the end of the 1 1 th refueling outage).

This report is submitted in accordance with the requirements of ASME Section XI, Article IWA-6200, Paragraph IWA-6230. The 1 1 th refueling outage was the first outage scheduled in the third inspection period of the second inspection interval. The second inspection interval is from January 1, 2000 to December 31, 2010.

This letter contains no regulatory commitments.

Should you have any questions related to this information, please contact Mr. Jim Peterson at (217) 937-2810.

Respectfully, Steven2 .Gackstetter Regulatory Assurance. Manager Clinton Power Station,4 (4-

Amergen Energy Company. LLC Clinton Power Station U-603857 Page 2 of 2 JLP/blf 0-Day Post-Outage ISI Summary Report cc: Regional Administrator, NRC Region III NRC Senior Resident Inspector, Clinton Power Station Office of Nuclear Facility Safety - IEMA Division of Nuclear Safety

AmerGen An Exelon Company INSERVICE INSPECTION

SUMMARY

REPORT REPORT DATE: May 02, 2008 INSERVICE DATE: April 24, 1987 REFUELING OUTAGE: CIRll CLINTON POWER STATION R.R.#3 Box 228, CLINTON, ILLINOIS 61727

ATTACHMENT U-603857 90-Day Post-Outage Inservice Inspection (ISI) Summary Report

INSERVICE INSPECTION

SUMMARY

REPORT CIRI I Prepared by: _ _ _ _ _ _ _ _ _ _

Reviewed by:

C)/ /

/

- 1 Approved by: 5 76mv-1 /

Concurred by: lm,-.) L/ -/

TABLE OF CONTENTS TITLE SECTION APPROVALS TABLE OF CONTENTS INTRODUCTION AND SCOPE ...............................

NIS-] CODE DATA REPORT .................................................................... 2

° ABSTRACT OF EXAMINATIONS LISTING OF EXAMINATION AND TESTING PROCEDURES ............. 3 LISTING OF EXAMINATION AND TESTING PERSONNEL ................ 4 LISTING OF EQUIPMENT AND MATERIALS .................... 5 REPAIR AND REPLACEMENT... ............................ 6 O LISTING OF REPAIRS/REPLACEMENTS PERFORMED

° NIS-2 DATA REPORTS

Page I of 3 SECTION 1 INTRODUCTION AND SCOPE INTRODUCTION:

This Summary Report covers the Inservice Inspection performed at Clinton Power Station (CPS), between February 26, 2006 and February 05, 2008. This is the first inspection performed during the third inspection period of the second ten (10)-year interval. During this Fuel Cycle, CPS experienced three forced outages (CIF47, C1F48, and CIF49) and one planned refueling outage (CIRI 1). All examinations, tests, repairs and replacements were performed in accordance with the CPS Inservice Examination Plan which complies with ASME Section XI, 1989 Edition.

The ASME Section XI examinations, tests and repairs/replacements were witnessed or verified by Authorized Nuclear Inservice Inspector (ANII) M. Haydon of Hartford Steam Boiler of Connecticut. This summary report contains additional augmented (non-ASME Section XI) inspection results not required to be witnessed or verified by the ANJI.

In accordance with IWA-6220, the name and description of the components examined are listed on the NIS-] Data Report and its attachments (Section 2). Further component information is obtainable through the reference number, or other information, for the specific item. The manufacturers' names for the components examined are also identified in htem 7 of the NIS-1 Data Report and their addresses are on file at CPS.

Documentation supporting this Summary Report is referenced in the Inservice Examination Plan, implementing procedures, or record files identified in the specific sections of this report.

Scope:

The scope of Inservice Inspection performed during this Fuel Cycle is summarized as follows:

Preservice Examinations - Preservice examinations were performed on bolting associated with the control rod drives and various flange bolting.

Scheduled Inservice Examinations - The NIS-1 Data Report (Section 2) provides the listing of all examinations completed during C IR. Conditions noted during CIRI1 and corrective measures taken are described in the NIS-1 Data Report.

Page 2 of 3 Snubbers - There are five hundred seventy-one (571) snubbers in the ISI Program required by the CPS Operational Requirements Manual (ORM). Per the initial outage scope, 79 snubbers were functionally tested as follows:

Fifty-nine (59) snubbers to meet the 10% ORM representative sample requirement, Four (4) snubbers that failed functional testing in CI RI0, Six (6) snubbers that were degraded in CI R10 (tested as part of the Service Life Monitoring Program).

Ten (10) snubbers that were selected for preventive maintenance per corrective action 205123-07.

It should be noted that twenty (20) type-] snubbers had preventive maintenance (PM) performed on them to address corrective action 205123-07. Ten (10) of these snubbers were part of the original 10% sample plan . The other ten (10) snubbers were selected solely to perform the PM activity. All were functionally tested before their PM.

During the performance of initial sample testing, five (5) snubbers (two (2) type-], two (2) type-2 and one (I) type-4) failed to meet functional testing acceptance criteria. Type-I snubbers consist of PSA-11/4 and '/2 sizes, type-2 snubbers consist of PSA-1, 3 and 10 sizes and type-4 snubbers consist of PSB-.05 mechanical struts.

For the two (2) type-I snubber failures, an additional ten (10) type-I snubbers (5 for each failure) were selected for functional testing. No failures occurred in these sample expansions.

For the two (2) type-2 snubber failures, an additional thirty-two (32) type-2 snubbers (16 for each failure) were selected for functional testing. One (1) additional failure occurred and sixteen (16) additional type-2 snubbers were selected for functional testing. No failures occurred in this additional sample expansion.

For the one (I) type-4 snubber failure, one (1) additional type-4 snubber was selected for functional testing. No failures occurred in this sample expansion.

Two of the type-I failures identified above resulted in a Failure Mode Group (FMG) being identified. When it was noted that two (2) type-1 snubbers exposed to similar environmental conditions had failed, a decision was made to test the remaining nine (9) snubbers in these locations. Some were type-I

Page 3 of 3 and some were type-2. Two (2) of the type-2 snubbers selected in the FMG also failed functional testing.

One (1) type-I snubber failed its PM inspection and one (1) type-I snubber that failed in CIRI0 also failed in CIRI 1.

Overall, one hundred and thirty-seven (137) snubbers were functionally tested in CIRl 1.

Component Supports - Twenty five (25) components supports (other than snubbers) and four (4) Class 3 integral attachments were scheduled for visual examination for CIRI 1.

All were found acceptable.

Pressure Tests - ASME Code Class I Components - A system leakage test and VT-2 inspection of ASME Code Class I components were successfully performed prior to plant startup.

Repairs and Replacements - During CI RI I no repairs and replacements were required as a result of scheduled examinations. Also during CIRI 1] there were several modifications performed. The modifications, as well as repairs and replacements which resulted from routine maintenance, are specifically detailed in Section 6 of this report.

FORM NIS-I OWNER'S REPORT FOR INSERVICE INSPECTION ATTACHMENT I

1. Owner: Amergen Energy Co.. LLC. 965 Chesterbrook Blvd.. Wayne, PA 19087
2. Plant: Clinton Power Station. RR3 Box 228. Clinton. IL 61727
3. Plant Unit: 1 4. Owner Certificate of Autherization: N/A
5. Commercial Service Date: 4-24-87 6. National Board Number for Unit: N/A
10. Abstract of Examination:

Listing of Examinations:

Table I lists scheduled examinations of components for Cl RI 1. The results column in the table provides further explanation for these examinations. Those items, which were examined, that require no further evaluation are identified as acceptable.

Table 2 lists scheduled visual examinations of component supports. The results column in the table provides further explanation for these examinations/tests. Those items, which were examined/tested, that require no further evaluation are identified as acceptable. The visual examination results of all supports were acceptable.

Table 3 lists visual examinations and functional testing of snubbers. The results column in the table provides further explanation for these examinations/tests. Those items, which were examined/tested, that require no further evaluation are identified as acceptable. The visual examination results of snubbers are identified as acceptable. For those snubbers, which had unacceptable functional tests, the additional snubbers tested are included in this table and discussed further in attachment 2.

Table 4 lists scheduled pressure tests. The results column in the table provides further explanation for these tests.

Current Interval Status:

Currently CPS is in the Third Period of the Second Interval. CPS had two (2) refueling outages, Cl R07 and CIR08 during the First Period. CPS had two (2) refueling outages, Cl R09 and ClR 10, during the Second Period. CPS will have two (2) refueling outages, Cl RI I and CI R 12, during the Third Period. With the exception of the examinations that may be deferred until the end of the inspection interval, the required examinations in each examination category were completed (Inspection Program B).

During the seventh refueling outage (Cl R07) two (2) items were identified as requiring relief from NRC. These items are identified as N7 and RHR-A-2. During the eighth refueling outage (Cl R08) ten (10) items were identified as requiring relief from NRC. These items are CH-C-2, RPV-C5, N2F, N2G, N3A, N3C, N4A, N4D, N5A, and N9A.

During the ninth refueling outage (CIR09) one (1) item was identified as requiring relief from NRC. This item is identified as I-MS-A-7PR-WA. During CR10 eleven items were identified as requiring relief from NRC. These items are identified as N11B, N2B, N2C, N2D, N2E, CH-C-2, I-RR-A-l, I-RR-B-I, 1-RH-20-7, 1-RT-36-7, and I-RT-36-1A.

During Cl RI I five (5) items were identified as requiring relief from NRC. These items are N8, I-MS-C-8PR-WA, I-MS-D-7PR-WA, I-RR-A-PR-1-WA, and RCIC-IA(I-4).

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As Required by the Provisions of the ASME Code Rules

1. Owner Amergen Energy Co., LLC, 965 Chesterbrook Blvd., Wayne, PA 19087
2. Plant Clinton Power Station, RR3 Box 228, ClintonIL 61727
3. Plant Unit 1 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date 4/24/1987 6. National Board Number for Unit N/A
7. Components Inspected Component or Manufacturer Manufacturer State National Appurtenance or Installer or Installer Number Board No.

Serial No.

Reactor Vessel 1B13-D003 Chicago Bridge & Iron Co. B5225 B005056 4442 RHR Pump 1E12-C002A Byron Jackson 741-S-1448 N/A N/A HPCS Pump 1 E22-CO01 Byron Jackson 731-S-1186 N/A N/A PCs-COO01 SE21 Pump Byron Jackson 741-S-1451 N/A N/A RCIC Pump BING HAM-WILLAMETTE 16210287 N/A NB-550 151-CO01 RHR Heat Exchanger JOSEPH OAT 2318-A N/A 1052 1E12BOO1A Valve ATWOOD & MORRILL 4-562 N/A N/A 1B21-F022D Valve E5834-2-1 1B33-F067A Anchor/Darling Valve Co. E5834-2-1 N/A N/A Valve E-6214-6-1 1E21-F005 Anchor/Darling Valve Co.

Valve E-6214-21 -1 1E22-F005 Anchor/Darling Valve Co. N/A N/A Valve Anchor/Darling Valve Co. E-6214-5-1 N/A N/A 1E51-F063 Piping Systems Illinois Power Co. See Note 1 N/A N/A Note 1: The piping components examined/tested are listed in Attachment 1 of this NIS-1 Data Report.

Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in. (2) information in the items 1 through 6 on this report is included on each sheet, and (3) each

  • sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-1 (Back)

8. Examination Dates 02/26/06 to 02/05/08 9. Inspection Interval from 01/01/00 to 12/31/10
10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval.

See Attachment 1.

11. Abstract of Conditions Noted.

See Attachment 2.

12. Abstract of Corrective Measures Recommended and taken.

See Attachment 2.

We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable) N/A Expiration Date N/A Date '5- ".- 0 Signed Amergen Energy Co., LLC By -

Owner

.CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Illinois and employed by Hartford Steam Boiler of Connecticut have inspected the components described in this owner's report during the period 02/26/06 to 02/5/08, and state that to the best of my knowledge and belief, the owner has performed examinations and taken corrective

.measures described in this owner's Report in accordance with the inspection plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, Expressed Or implied, concerning the examinations and corrective measures described in

(/aner*o Owner's Rep rt. Furthermore, neither the Inspector nor his employer shall be liable in any ry personal injury or property damage or a loss of any kind arising from or on 'tedý ith this inspection.

Commissions ._*i 7-J Inspect r's Signature National Board, state, province, and endorsements Date /X

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTION ATTACHMENT I TABLE I

1. Owner: Amergen Co., LLC, 965 Chesterbrook Blvd., Wayne, PA 19087
2. Plant: Clinton Power Station, RR3 Box 228, Clinton, IL 61727
3. Plant Uni: 1 4. Owner Certificate of Autherization: N/A
5. Commercial Service Date: 4-24-87 6. National Board Number for Unit: N/A
10. Abstract of Examinations: Listing of Scheduled Examinations.

REFERENCE ITEM EXAM CODE CODE CODE RESULTS NUMBER IDENTIFICATION TYPE ITEM CATEGORY CLASS 004900 N4A-W- I MECH UT RIlI R-A I ACCEPTABLE 004940 N4B-W-I MECH UT RI.I R-A I ACCEPTABLE 004980 N4C-W-l MECH UT R1I.1 R-A I ACCEPTABLE, 005025 N4D-W-I MECH UT RI.I1 R-A I ACCEPTABLE 005520 N9B-W-l UT NA NA I ACCEPTABLE 008100 VESSEL INTERIOR VT-3 B13.10 B-N-I I ACCEPTABLE 008111 Shroud Vertical Welds (8) EVT-I NA NA I ACCEPTABLE 008112 Tie Rods (2). Detail,65/245 VT-3 NA NA I ACCEPTABLE 008113 Tie Rods (2), Gen.,155/335 VT-3 NA NA I ACCEPTABLE 008352 FW SP END BRK BOLT STOP VT-I NA NA I ACCEPTABLE, NOTE 8 008451 CORESPRAY INT PIPING UT EVT-1 NA NA I ACCEPTABLE, NOTE 2 008555 RPV SP BRCKT ATT. VT-I B 13.20 B-N-2 I ACCEPTABLE, NOTE 3 008572 IRM (ONLY 4) VT-3 NA NA I ACCEPTABLE

.0 008573 SRM (ONLY 2) VT-3 NA NA I ACCEPTABLE, NOTE 7 008574 LPRM (ONLY 4) VT-3 NA NA I ACCEPTABLE, NOTE 6 008584 St Dryer Supp Brackets EVT-I NA NA I ACCEPTABLE, NOTE 4 008587 Steam Dryer VT-I NA NA NA ACCEPTABLE, NOTE 5 008588 JP Wedges (only 6) VT-I NA NA I ACCEPTABLE 008595 Jet Pump Beams UT NA NA I ACCEPTABLE 008711 CORE SPRAY SPARGRS EVT-1 NA NA I ACCEPTABLE 009300 CH-ME UT B 1.22 B-A I ACCEPTABLE 009350 CH-MF UT B1.22 B-A I ACCEPTABLE 009500 N8 UT B3.90 B-D I ACCEPTABLE, NOTE 1 009650 N8-IRS UT B3. 100 B-D I ACCEPTABLE 101220 l-MS-ASB-1-FB VT-I B7.50 B-G-2 I ACCEPTABLE 104440 1-MS-C-8PR-WA PT B10.20 B-K I ACCEPTABLE, NOTE 1 105420 I-MS-CSD-I-FB VT-I B7.50 B-G-2 I ACCEPTABLE 105820 I-MS-CSF-1-FB VT-I B7.50 B-G-2 I ACCEPTABLE 106680 I-MS-D-7PR-WA MT BI0.20 B-K I ACCEPTABLE, NOTE I 107220 I-MS-DSB-I-FB VT-I B7.50 B-G-2 I ACCEPTABLE 112480 I-FW-2-8 UT-E R1.1l R-A I ACCEPTABLE 112520 1-FW-2-6-3 UT-E R I. 11 R-A I ACCEPTABLE 112880 I-FW-I-3-10 UT-E R.II R-A I ACCEPTABLE 113380 I-FW-2-3-10 UT-E R.II R-A I ACCEPTABLE 114300 1-FW-I-1 UT-E R.II R-A I ACCEPTABLE 134980 I-RR-A-PR-I-WA PT BI0.20 B-K I ACCEPTABLE, NOTE 1 136440 I-RR-A-DRW-2-FB VT-I B7.50 B-G-2 1 ACCEPTABLE 151760 1-HP-5-12 UT-E RI. 1 R-A I ACCEPTABLE

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTION ATTACHMENT I TABLE I

1. Owner: Amergen Co., LLC, 965 Chesterbrook Blvd., Wayne, PA 19087
2. Plant: Clinton Power Station, RR3 Box 228, Clinton, IL 61727
3. Plant Uni: 1 4. Owner Certificate of Autherization: N/A
5. Commercial Service Date: 4-24-87 6. National Board Number for Unit: N/A
10. Abstract of Examinations: Listing of Scheduled Examinations.

REFERENCE ITEM EXAM CODE CODE CODE RESULTS NUMBER IDENTIFICATION TYPE ITEM CATEGORY CLASS 162340 I-RH-23-7-2 UT-E RI. I R-A I ACCEPTABLE 164380 I-RH-12-13-3 UT-E RI.1I R-A I ACCEPTABLE 164500 I-RH-12-13-2 UT-E RI ll R-A I ACCEPTABLE 181000 I-RI-14-9 UT-E RIllI R-A I ACCEPTABLE 181020 I-RI-14-5-4Q1 UT-E RI.lI R-A I ACCEPTABLE 181304 W0803566-4A UT-E Ri I1 R-A I CCEPTABLE 181940 IMC-43A MT BI0.20 B-K I CCEPTABLE 230680 I B33-F067A VT-I B7.70 B-G-2 I CCEPTABLE 231040 IE22-F005 VT- I B7.70 B-G-2 I CCEPTABLE 231100 IE51-F063 VT-I B7.70 B-G-2 I CCEPTABLE 250140 1B21-F022D VT-3 B12.50 B-M-2 I ACCEPTABLE 250960 1E21 -F005 VT-3 B12.50 B-M-2 I ACCEPTABLE 400100 HEA-3 MT UT C2.21 C-B 2 ACCEPTABLE 400110 HEA-3 IRS UT C2.22 C-B 2 ACCEPTABLE 400200 HEA-I THRU WA MT C3.10 C-C 2 ACCEPTABLE 577360 I-RH-21-16 MT C3.20 C-C 2 ACCEPTABLE 579620 I-RH-9-13-5 UT-E RI.20 R-A 2 ACCEPTABLE 579640 I-RH-9-13-7 UT-E RI.20 R-A 2 ACCEPTABLE 583420 I RH07018V-WA MT C3.20 C-C 2 ACCEPTABLE 594121 1RH07072S-WA MT C3.20 C-C 2 ACCEPTABLE 598200 IRH2200IA-WA MT C3.20 C-C 2 ACCEPTABLE 599360 I -RH-21-9A MT C3.20 C-C 2 ACCEPTABLE 800180 RHR-A-5 MT C6.10 C-G 2 ACCEPTABLE 801580 LPCS-5 MT C6.10 C-G 2 ACCEPTABLE 802560 HPCS-4 MT C6.10 C-G 2 ACCEPTABLE 803300 RCIC-3 MT C6.10 C-G 2 ACCEPTABLE 803600 RCIC-IA (1-4) MT C3.30 C-C 2 ACCEPTABLE, NOTE 1 940750 ISX01005X-WA VT-I D1.20 D-A 3 ACCEPTABLE 941000 ISXO0Oi7R-WA VT-I D1.20 D-A 3 ACCEPTABLE 943395 1SX24008A-WA VT-I D1.20 D-A 3 ACCEPTABLE 946670 1SXI 1022X-WA VT- I DI.20 D-A 3 ACCEPTABLE 950606 JP RI BR WELDED ATT (50%) EVT-I B 13.20 B-N-2 I ACCEPTABLE 950607 JP RISER WELDS (50%) EVT-I NA NA I ACCEPTABLE 950609 VARIOUS 1PSENSING LINES (50%)o V91- I II77NA NA I t CCEPTABLE

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTION ATTACHMENT 1 TABLE 1 Notes

1. Owner: Amergen Energy Co., LLC, 965 Chesterbrook Blvd., Wayne, PA 19087
2. Plant: Clinton Power Station, RR3 Box 228, Clinton, IL 61727
3. Plant Unit: 1 4. Owner Certificate of Autherization: N/A
5. Commercial Service Date: 4-24-87 6. National Board Number for Unit: N/A
10. Abstract of Examinations: Listing of Scheduled Examinations Note 1:

The examination coverage for these welds, N8, I -MS-C-8PR-WA, 1-MS-D-7PR-WA, I -RR-A-PR-1-WA, and RCIC-IA(1-4) was less than 90.0%. A relief request will be submitted.

Note 2:

Core Spray Internal piping - In accordance with BWR VIP-I18 document, Ultrasonic examinations were performed on the selected welds on Core Spray piping. Indications were recorded on three (3) of these welds (BP2, CP2, and DP2). This is not an ASME Section XI item.

See Attachment 2 for further discussion.

Note 3:

Surveillance Specimen Brackets -- Surveillance Specimen Brackets @ 003 and 177 degrees were examined during C 1R09 and it was identified that both lower tack welds on the attachment bracket were observed to be cracked. This is located outside the Section XI examination boundary. During CIR1O, this crack was monitored. During this outage, CIR1R , this crack was re-examined. See attachment 2 for further details.

Note 4:

Steam Dryer Support Brackets - During C 1R09 (2004) it was identified that several steam dryer support brackets appear to have contact marks and some do not have any contact marks with the steam dryer. This is not an ASME Section XI item. During CIR1 0 (2006), these brackets were examined and determined no changes. During this outage, C Ri 1, these brackets were re-examined and determined no changes.

Note 5:

Steam Dryer -

During this outage the Steam Dryer was re-examined to monitor the previously identified cracks in CIRlO (2006). In addition, several more cracks identified in the Steam Dryer. See attachment 2 for further details. The Steam Dryer is not an ASME Section XI item.

Note 6:

LPRM 30 During this outage a possible foreign material was observed in the lower group of holes in the LPRM 30-07 housing. This is not an ASME Section XI item. See attachment 2 for further details.

Note 7:

SRM 'A' -

During this outage cracking was noted on Dry Tube SRM 'A'. The cracking was noted in the NW, NE, and SW quadrants above the lower filet weld. This is not an ASME Section XI item. See attachment 2 for further details.

Note 8:

FW End Bracket Bolt Stop -

During this outage on the Feedwater Sparger End Bracket Bolt Stops, evidence of wear observed on FSB-1 at 005 deg, FSB-2 at 085 deg, FSB-3 at 095, and FSB-4 at 175 deg. This is not an ASME Section XI item. See attachment 2 for further details.

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTION ATTACHMENT I TABLE 2

1. Owner: Amergen Co., LLC, 965 Chesterbrook Blvd., Wayne, PA 19087
2. Plant: Clinton Power Station, RR3 Box 228, Clinton, IL 61727
3. Plant Uni: 1 4. Owner Certificate ofAutherization: N/A
5. Commercial Service Date: 4-24-87 6. National Board Number for Unit: N/A
10. Abstract of Examinations: Listing of Scheduled Examinations.

REFERENCE ITEM EXAM CODE CODE CODE RESULTS NUMBER IDENTIFICATION TYPE ITEM CATEGORY CLASS 903755 1FW02008C VT-3 F1.10 F-A I ACCEPTABLE 906010 1HP01007A VT-3 FI.10 F-A 1 ACCEPTABLE 906145 1HP03003X VT-3 F1.20 F-A 2 ACCEPTABLE 908040 1LP02002X VT-3 F 1.0 F-A I ACCEPTABLE 912000 IRH01001C VT-3 FI.10 F-A I ACCEPTABLE 912185 1RH06004X VT-3 F1.10 F-A I ACCEPTABLE 913110 IRH09023V VT-3 F1.20 F-A 2 ACCEPTABLE 913495 1RH07079A VT-3 F1.20 F-A 2 ACCEPTABLE 914010 1RH09064X VT-3 F1.20 F-A 2 ACCEPTABLE 914180 IRHI0003A VT-3 F1.20 F-A 2 ACCEPTABLE 914789 1RH07019X VT-3 F1.20 F-A 2 ACCEPTABLE 917015 IRHO2004V VT-3 F1.20 F-A 2 ACCEPTABLE 919045 I RII0009X VT-3 F1.10 F-A I ACCEPTABLE 919050 IRI100I0X VT-3 F1.10 F-A I ACCEPTABLE 920420 1R103001V VT-3 F1.20 F-A 2 ACCEPTABLE 921500 RCIC PUMP VT-3 F1.40 F-A 2 CCEPTABLE 922010 IH301A VT-3 F1.40 F-A I CCEPTABLE 922780 1H354B VT-3 F1.10 F-A I CCEPTABLE 940745 ISX01005X VT-3 F1.30 F-A 3 ACCEPTABLE 940995 ISX01017R VT-3 F1.30 F-A 3 ACCEPTABLE 941810 I SX02008X VT-3 F1.30 F-A 3 ACCEPTABLE 942985 1SX1001 IR VT-3 F1.30 F-A 3 ACCEPTABLE 943005 ISX10012X VT-3 F1.30 F-A 3 ACCEPTABLE 943390 1SX24008A VT-3 F1.30 F-A 3 ACCEPTABLE 946665 1SX 1]022X VT-3 F1.30 F-A 3 *CCEPTABLE

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTION ATTACHMENT I TABLE 3

1. Owner: Amergen Co., LLC, 965 Chesterbrook Blvd., Wayne, PA 19087
2. Plant: Clinton Power Station, RR3 box 228, Clinton, IL 61727
3. Plant Uni: 1 4. Owner Certificate ofAutherization: N/A
5. Commercial Service Date: 4-24-87 6. National Board Number for Unit: N/A
10. Abstract of Examinations: Listing of Scheduled Examinations.

REFERENCE ITEM EXAM CODE CODE CODE RESULTS NUMBER IDENTIFICATION TYPE ITEM CATEGORY CLASS 903715 IFWOIOOIS VT-3/FT :1.10 F-A I ACCEPTABLE 903780 IFW01007S VT-3/FT F1.10 F-A I ACCEPTABLE 903740 1FW02005S VT-3/FT ý1.10 F-A I ACCEPTABLE 909258 IMS05028S VT-3/FT 1.10 F-A I ACCEPTABLE 909283 1MS38002S VT-3/FT F1.10 F-A I ACCEPTABLE 909295 1RB31514S VT-3/FT -1.10 F-A I ACCEPTABLE 909289 1RB31516S VT-3/FT I1.10 F-A I DEGRADED 909297 1RB31529S VT-3/FT I1.10 F-A 1 FT UNACCEPTABLE 919130 IRIOI007S VT-3/FT 71.10 F-A I ACCEPTABLE 919160 IRII0103W VT-3/FT 71.10 F-A I FT UNACCEPTABLE 919170 IRII0105W VT-3/FT -1.10 F-A I ACCEPTABLE 919266 1R108017S VT-3/FT :1.10 F-A I ACCEPTABLE 923010 IRT01003S VT-3/FT -1.10 F-A I ACCEPTABLE 923090 IRT01035S VT-3/FT -1.10 F-A I ACCEPTABLE 923200 IRT01084W VT-3/FT -1.10 F-A I DEGRADED 909165 ISIOIC VT-3/FT 71.10 F-A I ACCEPTABLE 909170 IS102C VT-3/FT 71.10 F-A I ACCEPTABLE 909075 IS103B VT-3/FT --1.10 F-A I ACCEPTABLE 922120 1S369A VT-3/FT -1.10 F-A I ACCEPTABLE 903876 IHG15010S VT-3/FT qA NA 2 ACCEPTABLE 906160 1HP03006S VT-3/FT :71.20 F-A 2 ACCEPTABLE 906175 I HP0301OS VT-3/FT :1.20 F-A 2 ACCEPTABLE 906340 1HP03014S VT-3/FT -1.20 F-A 2 ACCEPTABLE 906215 1HP03028S VT-3/FT z1.20 F-A 2 ACCEPTABLE 906220 1HP03029S VT-3/FT -1.20 F-A 2 ACCEPTABLE 906320 1HP03032S VT-3/FT -1.20 F-A 2 ACCEPTABLE 906200 1HP03038S VT-3/FT F1.20 F-A 2 DEGRADED 906680 1HP03049S VT-3/FT 4A NA 2 ACCEPTABLE 903888 IHP04003S VT-3/FT 4A NA 2 ACCEPTABLE 903890 1HP04016S-E VT-3/FT 4A NA 2 ACCEPTABLE 903892 1HP04016S-W VT-3/FT 'A NA 2 ACCEPTABLE 906280 1HP08006S VT-3/FT 1A NA 2 ACCEPTABLE 906300 1HP08025S VT-3/FT 1A NA 2 ACCEPTABLE 906724 1IS01042S VT-3/FT qA NA 2 ACCEPTABLE 906752 ILP03006S VT-3/FT 4A NA 2 ACCEPTABLE 906754 fILP03015S VT-3/FT A NA 2 ACCEPTABLE 906756 [1LP03016S VT-3/FT ýA NA 2 ACCEPTABLE

FORM NIS-I OWNER'S REPORT FOR INSERVICE INSPECTION ATTACHMENT I TABLE 3

1. Owner: Amergen Co., LLC, 965 Chesterbrook Blvd., Wayne, PA 19087
2. Plant: Clinton Power Station, RR3 box 228, Clinton, IL 61727
3. Plant Uni: 1 4. Owner Certificate of Autherization: N/A
5. Commercial Service Date: 4-24-87 6. National Board Number for Unit: N/A
10. Abstract of Examinations: Listing of Scheduled Examinations.

REFERENCE ITEM EXAM CODE CODE CODE RESULTS NUMBER IDENTIFICATION TYPE ITEM CATEGORY CLASS 908450 ILP04021S VT-3/FT qA NA 2 FT UNACCEPTABLE 909338 1RB21596S VT-3/FT :1.20 F-A 2 ACCEPTABLE 909332 1RB21598S VT-3/FT NA NA 2 ACCEPTABLE 913270 IRHO7003S VT-3/FT -1.20 F-A 2 DEGRADED 913280 1RH07005S VT-3/FT -1.20 F-A 2 ACCEPTABLE 913297 1RH07009S-DN VT-3/FT 1.20 F-A 2 FT UNACCEPTABLE 913300 1RH07009S-UP VT-3/FT -1.20 F-A 2 ACCEPTABLE 913305 IRHO7010S VT-3/FT F1.20 F-A 2 ACCEPTABLE 914790 1RHO7020S VT-3/FT -1.20 F-A 2 ACCEPTABLE 914820 1RH07026S VT-3/FT --1.20 F-A 2 ACCEPTABLE 914830 1RH07028S VT-3/FT -1.20 F-A 2 ACCEPTABLE 914850 1RH07032S VT-3/FT -1.20 F-A 2 ACCEPTABLE 915570 1RH07048S VT-3/FT qA NA 2 ACCEPTABLE 915610 1RH071 IOS VT-3/FT ýA NA 2 ACCEPTABLE 916391 1RH07114S-W VT-3/FT F1.20 F-A 2 ACCEPTABLE 916420 I RH07119S-E VT-3/FT :1.20 F-A 2 ACCEPTABLE 916430 1RH07119S-W VT-3/FT 1.20 F-A 2 ACCEPTABLE 913425 1RH08073S VT-3/FT 1.20 F-A 2 ACCEPTABLE 913185 1RH09029S VT-3/FT -1.20 F-A 2 ACCEPTABLE 914170 1RH09038S VT-3/FT -1.20 F-A 2 ACCEPTABLE 914025 1RH09067S VT-3/FT z1.20 F-A 2 ACCEPTABLE 914165 1RH09091S VT-3/FT :1.20 F-A 2 ACCEPTABLE 916180 IRHI3015S VT-3/FT ,A NA 2 ACCEPTABLE 915100 1RH 16011OS VT-3/FT '4A NA 2 ACCEPTABLE 914260 1RH16034S VT-3/FT 1,A NA 2 ACCEPTABLE 914270 IRH16035S VT-3/FT 14A NA 2 ACCEPTABLE 916040 IRH72015S VT-3/FT ',1A NA 2 ACCEPTABLE 916060 1RH72040S VT-3/FT A NA 2 ACCEPTABLE 914240 1RH80006S VT-3/FT ,A NA 2 ACCEPTABLE 920400 1R102016S VT-3/FT NA NA 2 ACCEPTABLE 920305 1R108010S VT-3/FT F1.20 F-A 2 ACCEPTABLE 920975 1R113004S VT-3/FT 'A NA 2 ACCEPTABLE 916140 1SX30006S VT-3/FT 1A NA 2 ACCEPTABLE 909620 IFC01016S VT-3/FT \A NA 3 ACCEPTABLE 909630 IFC01022S VT-3/FT qA NA 3 ACCEPTABLE 911260 IMS10806S VT-3/FT ý1.30 F-A 3 ACCEPTABLE 910525 1MS24006S VT-3/FT 1.30 F-A 3 ACCEPTABLE

FORM NIS-] OWNER'S REPORT FOR INSERVICE INSPECTION ATTACHMENT I TABLE 3

1. Owner: Amergen Co., LLC, 965 Chesterbrook Blvd., Wayne, PA 19087
2. Plant: Clinton Power Station, RR3 box 228, Clinton, IL 61727
3. Plant Uni: 1 4. Owner Certificate of Autherization: N/A
5. Commercial Service Date: 4-24-87 6. National Board Number for Unit: N/A
10. Abstract of Examinations: Listing of Scheduled Examinations.

REFERENCE ITEM EXAM CODE CODE CODE RESULTS NUMBER IDENTIFICATION TYPE ITEM CATEGORY CLASS 910420 1MS27001S VT-3/FT -1.30 F-A 3 ACCEPTABLE 910715 1MS28007S VT-3/FT -1.30 F-A 3 ACCEPTABLE 911055 1MS30002S VT-3/FT -1.30 F-A 3 ACCEPTABLE 911095 1MS30010S VT-3/FT 71.30 F-A 3 ACCEPTABLE 910095 1MS32005S VT-3/FT :1.30 F-A 3 FT UNACCEPTABLE 910115 IMS32009S VT-3/FT -1.30 F-A 3 DEGRADED 910395 1MS33008S VT-3/FT -1.30 F-A 3 ACCEPTABLE 910860 1MS35005S VT-3/FT -1.30 F-A 3 ACCEPTABLE 911037 1MS36012S VT-3/FT :1.30 F-A 3 ACCEPTABLE 909640 1RH07094S VT-3/FT NA NA 3 ACCEPTABLE 924025 1RT06006S VT-3/FT 1.30 F-A 3 ACCEPTABLE 924045 1RT06009S VT-3/FT :71.30 F-A 3 ACCEPTABLE 924050 1RT06014S VT-3/FT 4A NA 3 FT UNACCEPTABLE 924055 1RT06015S VT-3/FT -1.30 F-A 3 ACCEPTABLE 924060 1RT06018S VT-3/FT -1.30 F-A 3 ACCEPTABLE 924065 1RT06022S VT-3/FT 14A NA 3 DEGRADED 924070 1RT06026S VT-3/FT \JA NA 3 FT UNACCEPTABLE 924075 1RT06029S VT-3/FT \1A NA 3 ACCEPTABLE 924080 1RT06033S VT-3/FT NA NA 3 ACCEPTABLE 924085 1RT06037S VT-3/FT '4A NA 3 ACCEPTABLE 924090 1RT06040S VT-3/FT F1.30 F-A 3 ACCEPTABLE 924037 1RT06044S VT-3/FT 1.30 F-A 3 ACCEPTABLE 924040 1RT06046S VT-3/FT 1.30 F-A 3 ACCEPTABLE 924095 I RT07006S-N VT-3/FT \1A NA 3 DEGRADED 924100 I RT07006S-S VT-3/FT qA NA 3 FT UNACCEPTABLE 924105 1RT07009S VT-3/FT 4A NA 3 ACCEPTABLE 924110 1RT07014S VT-3/FT F1.30 F-A 3 ACCEPTABLE 924115 1RT07028S VT-3/FT 1.30 F-A 3 ACCEPTABLE 924120 1RT07032S VT-3/FT qA NA 3 FT UNACCEPTABLE 924125 1RT07036S VT-3/FT 14A NA 3 ACCEPTABLE 924130 1RT07037S VT-3/FT ýA NA 3 ACCEPTABLE 924135 1RT07040S VT-3/FT 1A NA 3 ACCEPTABLE 924140 1RT07042S VT-3/FT qA NA 3 ACCEPTABLE 924145 1RT07044S VT-3/FT 4A NA 3 ACCEPTABLE 924150 1RT07048S VT-3/FT 4A NA 3 ACCEPTABLE 924155 1RT07049S VT-3/FT 4A NA 3 ACCEPTABLE 924310 1RT07052S VT-3/FT 1.30 F-A 3 ACCEPTABLE

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTION ATTACHMENT I TABLE 3

1. Owner: Amergen Co., LLC, 965 Chesterbrook Blvd., Wayne, PA 19087
2. Plant: Clinton Power Station, RR3 box 228, Clinton, IL 61727
3. Plant Uni: 1 4. Owner Certificate of Autherization: N/A
5. Commercial Service Date: 4-24-87 6. National Board Number for Unit: N/A
10. Abstract of Examinations: Listing of Scheduled Examinations.

REFERENCE ITEM EXAM CODE CODE CODE RESULTS NUMBER IDENTIFICATION TYPE ITEM CATEGORY CLASS 944235 1SX09016S VT-3/FT :1.30 F-A 3 ACCEPTABLE 945425 1SX12010S VT-3/FT -1.30 F-A 3 ACCEPTABLE 946280 1SX15019S VT-3/FT -1.30 F-A 3 ACCEPTABLE 947220 1SX17027S VT-3/FT 4A NA 3 ACCEPTABLE 947260 1SX19001S VT-3/FT NA NA 3 ACCEPTABLE 947280 ISX19014S VT-3/FT NA NA 3 ACCEPTABLE 909660 1TX 16049S VT-3/FT NA NA 3 FT UNACCEPTABLE 948920 IRH18006S VT-3/FT NA NA D ACCEPTABLE 947560 1RH23020S VT-3/FT NA NA D ACCEPTABLE 903858 1DG02001 S VT-3/FT NA NA 0 ACCEPTABLE 903868 1DG02012S VT-3/FT 1A NA 0 ACCEPTABLE 903852 1DG0601OS VT-3/FT qA NA 0 ACCEPTABLE 949280 IVG01005S VT-3/FT NA NA 0 ACCEPTABLE 949300 IVGO1021S VT-3/FT qA NA 0 ACCEPTABLE 949200 IVG01023S VT-3/FT qA NA 0 ACCEPTABLE 949320 IVG01036S VT-3/FT qA NA 0 ACCEPTABLE 949360 1VG02024S VT-3/FT qA NA 0 ACCEPTABLE 949040 1VG03016S VT-3/FT qA NA 0 ACCEPTABLE 949060 1VG03025S VT-3/FT 4A NA 0 ACCEPTABLE 949000 1VG09001 S VT-3/FT IA NA 0 ACCEPTABLE 949020 IVG10012S VT-3/FT NA NA 0 ACCEPTABLE 949180 1VG 11029S VT-3/FT qA NA 0 ACCEPTABLE 949380 1VG12002S VT-3/FT qA NA 0 ACCEPTABLE 949400 IVG12005S VT-3/FT ,A NA 0 ACCEPTABLE 949100 1VG13055S VT-3/FT NA NA 0 ACCEPTABLE 949160 1VG16026S VT-3/FT FA NA 0 ACCEPTABLE

FORM NIS-) OWNER'S REPORT FOR INSERVICE INSPECTION ATTACHMENT I TABLE 4

1. Owner: Amergen Co., LLC, 965 Chesterbrook Blvd., Wayne, PA 19087
2. Plant: Clinton Power Station, RR3 box 228, Clinton, IL 61727
3. Plant Uni: 1 4. Owner CertificateofAutherization: N/A
5. Commercial Service Date: 4-24-87 6. National Board Number for Unit: N/A
10. Abstract of Examinations: Listing of Scheduled Examinations.

ITEM IEXAM CODE CODE CODE RESULTS IDENTIFICATION TYPE ITEM ;CATEGORY CLASS ALL CLASS I COMPONENTS ýVT-2 B 15.10.50.60.70 JBP-2 I IACCEPTABLE. SEE NOTE I

FORM NIS-] OWNER'S REPORT FOR INSERVICE INSPECTION ATTACHMENT I TABLE 4 Notes

1. Owner: Amergen Energy Co.. LLC. 965 Chesterbrook Blvd.. Wayne. PA 19087
2. Plant: Clinton Power Station. RR3 Box 228. Clinton. IL 61727
3. Plant Unit: 1 4. Owner Certificate of Autherization: N/A
5. Commercial Service Date: 4-24-87 6. National Board Number for Unit: N/A
10. Abstract of Examinations: Listing of Scheduled Examinations Note 1: Pressure Tests Class I Components A system leakage test and VT-2 inspection of ASME Class I components was performed prior to plant startup.

Condition noted: Only minor leakage from valve packing and bolted flanged connections was noted.

Corrective measures: Leakage was corrected to acceptable levels.

FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTION ATTACHMENT 2

1. Owner: AmerGen Enervy Co.. LLC. 965 Chesterbrook Blvd.. Wayne, PA 19087
2. Plant: Clinton Power Station. RR3 Box 228. Clinton. IL 61727
3. Plant Unit: 1 4. Owner Certificate of Authorization: N/A
5. Commercial Service Date: 4-24-87 6. National Board Number for Unit: N/A
10. Abstract of Examinations:

Examinations:

RPV Surveillance Specimen Brackets -

Condition Noted - During the CIR09 (2004) outage examination of the Surveillance Specimen Brackets located at 003 deg. And 177 deg., both lower lack welds on the attachment brackets were observed cracked. This is located outside the Section XI examination boundary. During CI RIO (2006) outage these, brackets were examined and no crack growth was identified. During this outage, CI RI 1, these brackets were examined and no crack growth was identified.

Corrective Measures - Clinton Power Station has evaluated this and justified continued operation.

These tack welds are outside the examination boundary.

Core Spray Internal Piping -

In accordance with the VIP-I 8. BWR Core Spray Internals Inspection and Evaluation Guidelines, Ultrasonic examinations were performed on the accessible areas of the selected welds on Core Spray Internal Piping.

Condition Noted - During this outage, CI R 11 (2008), three indications were monitored which wee identified on these welds, BP2, CP2, and DP2 in CIR09 (2004) and CIR07 (2000). These indications were also recorded in CIR09 outage (2004). Two (2) of these welds, BP2 and CP2, have indications previously identified in CIR07 (2000) and continued operation was justified. During this, CIRI 1 (2008), outage no crack growth was identified.

Corrective Measures - The VIP-I8 document requires Clinton to take the following steps:

Expansion of sample - CPS has scheduled inspection of all accessible welds on the Core Spray Internal Piping. Therefore, no sample expansion is required.

Crack Growth Analysis - Crack Growth analysis was performed in CI R09 (2004) to demonstrate the structural integrity of the internal piping for continued operation for two (2) cycles. During this outage, CI RI 1. new analysis was not performed since there was no crack growth identified. Crack Growth Analysis performed in 2004 is still a valid analysis.

Leakage Rate Calculation - Separate leakage rate calculations were performed in CI R09 (2004) to demonstrate that the required amount of water can be transported to the core with the existing condition including crack growth.

Steam Dryer -

Clinton Power station has examined the steam dryer in accordance with the requirements of the BWR Owner's Group Vessel Internals Project (BWRVIP) document 139. The steam dryer is not addressed in ASME Section XI. The indications fiom the previous outage, CIRIO (2006) were re-examined and determined no change. In addition, the following several more cracks identified in CIRIl (2008):

I - Conditions Noted - During the IVVI examination of Steam Dryer Drain Channel 7, V-1 4 weld, a base metal crack was observed adjacent to the weld. This crack is in the area of the access hole cover. The examination of the Drain Channel 3, V-06, similar crack like indications were observed in the skirt adjacent to the V-06 weld in the area of an access hole cover. In addition, indications were observed at 90 degrees access hole patch.

Corrective Measures - Clinton Power Station has evaluated these indications and cracks and justified continued operation.

2 - Conditions Noted - As a result of identifying the above cracking in the base material close to the access hole patches, it was decided to inspect the dryer from inside. The inspection of the 2 Access Hole Patches from ID revealed several linear indications in the base material at both locations. The inspection was expanded to the remaining 4 other patches from ID. The same type linear indications were observed at these 4 locations. In addition, during this expanded scope from ID, cracking was observed in the Upper Support Ring at the location of 210 degrees ID Patch.

Corrective Measures - Clinton Power Station has evaluated these linear indications and cracking observed and justified continued operation.

3 - Condition Noted - During the removal of the steam dryer during the CIIR1I outage (2008), the dryer hit one of the Tri-Nuke devices causing some mechanical damage on the bottom side of the skirt lower support ring at 135 degrees.

Corrective Measures - Clinton Power Station has evaluated this damage and justified continued operation.

LPRM 30-07 -

Condition Noted - During this outage, CIR11 (2008), a possible foreign material was observed in the lower group of holes in the LPRM 30-07 housing.

Corrective Measures - Clinton Power Station has evaluated this as a loose part and justified continued operation.

SRM 'A'-

During this outage, CIRI 1 (2008), cracking was observed on Dry Tube SRM 'A'. The cracking was noted in the NW, NE, and SW quadrants above the lower filet weld.

Corrective Measures - Clinton Power Station has evaluated these cracking and justified continued operation.

FW End Bracket Bolt Stop -

During this outage, C1RI 1 (2008), on the Feedwater Sparger End Bracket Bolt Stops, evidence of wear observed on FSB-I at 005 deg, FSB-2 at 085 deg, FSB-3 at 095, and FSB-4 at 175 deg.

Corrective Measures - Clinton Power Station has evaluated this wear and justified continued operation.

Snubber Functional Testing:

There are five hundred seventy-one (571) snubbers in the ISI Program required by the CPS Operational Requirements Manual (ORM). Per the initial outage scope, 79 snubbers were functionally tested as follows:

-- Fifty-nine (59) snubbers to meet the 10% ORM representative sample requirement,

-- Four (4) snubbers that failed functional testing in C IRIO,

-- Six (6) snubbers that were degraded in CIRI 0 (tested as part of the Service Life Monitoring Program).

-- Ten (10) snubbers that were selected for preventive maintenance per corrective action 205123-07.

It should be noted that twenty (20) type-1 snubbers had preventive maintenance (PM) performed on them to address corrective action 205123-07. Ten (10) of these snubbers were part of the original 10% sample plan. The other ten (10) snubbers were selected solely to perform the PM activity. All were functionally tested before their PM.

During the performance of initial sample testing, five (5) snubbers (two (2) type-], two (2) type-2 and one (1) type-4) failed to meet functional testing acceptance criteria. Type-1 snubbers consist of PSA-1/ and '/2 sizes, type-2 snubbers consist of PSA-]. 3 and 10 sizes and type-4 snubbers consist of PSB-.05 mechanical struts.

-- For the two (2) type-I snubber failures, an additional ten (10) type-I snubbers (5 for each failure) were selected for functional testing. No failures occurred in these sample expansions.

-- For the two (2) type-2 snubber failures, an additional thirty-two (32) type-2 snubbers (16 for each failure) were selected for functional testing. One (1) additional failure occurred and sixteen (16) additional type-2 snubbers were selected for functional testing. No failures occurred in this additional sample expansion.

-- For the one (I) type-4 snubber failure, one (1) additional type-4 snubber was selected for functional testing. No failures occurred in this sample expansion.

Two of the type-I failures identified above resulted in a Failure Mode Group (FMG) being identified. When it was noted that two (2) type-I snubbers exposed to similar environmental conditions had failed, a decision was made to test the remaining nine (9) snubbers in these locations. Some were type-I and some were type-2. Two (2) of the type-2 snubbers selected in the FMG also failed functional testing.

One (1) type-I snubber failed its PM inspection and one (1) type-I snubber that failed in C IRI 0 also failed in CIRI1.

Overall, one hundred and thirty-seven (137) snubbers were functionally tested in CIRI 1.

Type-I Snubbers:

There are ninety-five (95) type-I snubbers in the CPS I SI Program. Ten (10) of these were selected for testing under the initial 10% sample plan. These ten (10) snubbers also had PM activities performed on them. Two (2) snubbers. I RT07006S-S and IRT06014S, failed to meet the functional testing acceptance criteria. Issue Reports 719314 and 719630 were generated. These two snubbers were disassembled for failure analysis. The results of these evaluations were:

-- I RT07006S-S - The failure analysis found dry grease with the inertia mass and torque drum frozen together. When these components were freed, it was noted the screw shaft was bent. The capstan spring had very deep grooves on the tangs from excessive vibration. The snubber had failed due to lack of lubrication and vibration. This snubber was last tested in RF5.

-- IRT06014S - The failure analysis found very dry grease (powder) with the inertia mass and torque drum frozen together. When these components were freed, it was noted the screw shaft was bent. The capstan spring had vibration marks on the tangs. The snubber had failed due to lack of lubrication and vibration. This snubber was last tested in RF2.

Due to these failures, ten (10) snubbers (5% for each failure or 5 for each failure) were selected for testing. All ten (10) snubbers passed the functional testing acceptance criteria. Also, due to these failures, a Failure Mode Group (FMG) was identified. Nine (9) other snubbers located in similar

environments were functionally tested. This included type-I and type-2 snubbers. Two (2) of the type-2 snubbers from this FMG (1RT06026S and 1RT07032S) also failed. Their failures are discussed in the type-2 section of this report.

Four (4) snubbers, 1MS05028S, 1RB31514S. 1RT06009S and 1RT06040S, were identified in CIR10 as degraded and included in the CIR1 I testing plan for trending purposes. All four (4) snubbers passed their functional testing acceptance criteria. Three (3) snubbers, IRB31 516S, 1RT06022S and IRT07006S-N were classified as degraded in C IRI 1. They were replaced and will be tested again in CIR12.

Three (3) snubbers, 1RB21.596S, 1RB31516S and 1RB31529S failed functional testing performed in C IRI 0 and were included in the testing plan as required. One (1) snubber, IRB31529S, failed to meet the functional testing acceptance criteria. Issue Report 722836 was generated. 1RB31529S was disassembled for evaluation with the following results:

-- IRB31529S - This snubber and the adjacent spring can support (1RB31528V) both showed evidence of misalignment during the pre-VT3 inspection. Issue Report 722252 was generated. The as-found cold set position was outside the limits for this location. An engineering walkdown determined that the spring can support rod was in contact with the spring can. The hanger was not performing its function and the snubber was bearing additional load. When the snubber was released from this misaligned position, the line relaxed to its expected, cold set position. The snubber failure analysis found the screw shaft bent, with the grease dark and sticky. The capstan spring tangs, inner tube, both guide rods and the guide plate had vibration marks evident. This snubber was last tested in CIR10.

As required by the ORM, piping components on which these snubbers are installed were analyzed to ensure the integrity of the piping component. The results were satisfactory and documented in Engineering Change (EC) documents 268932, 368932, 369210 and 369077.

Due to the large number of type-I failures seen in C IR09 and in response to Issue Report 205123, CPS continued the PM program started on type-I snubbers in C IR 10. 20% of all type-I snubbers had an external visual inspection, disassembly, internal inspection, cleaning, regreasing and reassembly performed. The NRRG-1 59 grease originally used was replaced by NRRG-2 grease, which is less susceptible to drying out from high irradiation. Twenty (20) snubbers were selected.

Ten (10) were from the initial 10% sample plan population and the other ten (10) were randomly selected. One (1) snubber, 1TX16049S, was replaced due to PM inspection indications. Issue Report 723273 was generated to document the inspection results. Indications noted during the failure analysis performed on this snubber included:

-- 1TX16049S - The failure analysis noted dry grease throughout, vibration marks and wear in many locations and a bent shaft. This snubber was last tested in RF7.

This PM will continue until all 95 type-1 snubbers have been inspected and regreased. This PM will most likely continue throughout the life of the plant on those snubbers in harsh environments.

Type-2 Snubbers:

There are three hundred and seventeen (317) type-2 snubbers in the CPS ISI Program. Thirty-two (32) were selected for testing under the initial 10% sample plan. Two (2) snubbers, 1RH07009S-DN and 1MS32005S failed functional testing. Issue Reports 7171465 and 725997 were generated.

These snubbers were disassembled for failure analysis. The results of these inspections were:

-- 1RH07009S-DN - The failure analysis found no evidence of degradation or any damaged parts.

This was the first snubber to be tested during the pre-outage period, and it was thought that an anomaly in the test stand might have occurred to cause the test results noted. Basic-PSA was contacted, and they provided an evaluation of the test results. All future attempts to test this snubber resulted in acceptable performance. This snubber was last tested in RF4.

-- IMS32005S - The failure analysis found rust and colTosion inside the housing assembly. There was some grease on the capstan spring and vibration marks on the capstan spring keeper and rings.

Excessive grease was noted. This snubber was last tested in RF3.

Due to these failures, thirty-two (32) snubbers (5% of total population for each failure) were selected for testing. One (1) snubber, I LP04021 S, failed functional testing. Sixteen (16) additional snubbers were selected and all passed the functional testing acceptance criteria. The failure analysis performed on 1LP04021 S revealed:

-- I LP04021 S - Dry grease noted throughout snubber internal parts. Vibration induced wear was noted on the support and telescoping cylinders. This snubber was last tested in RF5.

As stated in the type-I snubber section, due to two (2) type-I snubber failures, a Failure Mode Group (FMG) was identified. Nine (9) other snubbers located in similar locations were functionally tested. This included type-I and type-2 snubbers. Two (2) of the type-2 snubbers (1RT06026S and IRT07032S) failed functional testing. Their failure analysis inspections determined:

-- I RT06026S - Found dry grease in all areas but the thrust bearing assembly and vibration marks on the capstan spring tangs. This snubber was last tested in RF4.

-- I RT07032S -Noted the capstan spring was not properly engaged. Dark, sticky grease was found on top of the ball bearing screw assembly. This snubber was last tested in RF5.

As required by the ORM, piping components on which this snubber is installed were analyzed to ensure the integrity of the piping component. The results were satisfactory and documented in Engineering Change (EC) documents 368873, 369185, 369172 and 369197.

One (1) snubber, I RT01003S, was tested as required due to failing in CIRI0. This snubber passed the functional testing acceptance criteria.

One (1) snubber, 1RT0l035S,. was tested due to be classified as degraded in CIRIO. This snubber passed the functional testing acceptance criteria. Four (4) snubbers were identified as degraded during CIRI 1 (11HP03038S, 1MS32009S, IRH07003S and 1VG16026S). These four (4) snubbers will be tested in CIRI2.

Type-3 Snubbers:

There are one hundred and seventeen (117) type-3 snubbers in the CPS IS] Program. Twelve (12) were selected for testing under the initial 10% sample plan. All twelve (12) snubbers passed the functional testing acceptance criteria. One (1) snubber, 1RT01084W, was replaced due to degraded functional testing results. This snubber will be tested in CRI 2.

One (1) snubber, 1MS30002S, was identified as degraded in CIRIO. This snubber passed the functional testing acceptance criteria.

Type-4 Snubbers:

There are four (4) type-4 snubbers in the CPS 1SI Program. One (1) snubber was selected for testing under the initial 10% sample plan. This snubber (1RIO] 013W) failed the functional testing acceptance criteria. An additional type-4 snubber (]RIO]015W) was selected and passed functional testing. The failure analysis for IRIO)01 3W has not been completed yet, as it needs to be sent to an off-site facility for the failure analysis. This was the first time a type-4 snubber has failed at CPS.

As required by the ORM, piping components on which this snubber is installed were analyzed to ensure the integrity of the piping component. The results were satisfactory and documented in Engineering Change (EC) document 369197.

Type-6 Snubbers:

There are thirty-eight (38) type-6 snubbers in the CPS ISI Program. Four (4) were selected for testing under the initial 10% sample plan. All four (4) snubbers passed the functional testing acceptance criteria. All four (4) type-6 snubbers tested and a spare removed in CIRIO were rebuilt in CIRI11. Each snubber was disassembled and inspected and the seals and fluid were replaced and analyzed. During inspection of one snubber (1 S369A), wear was noted on the bushings and piston rod. This snubber was replaced with a spare. Test results will be used to validate the current fluid and seal replacement frequencies and possibly adjust them.

SECTION 3 LISTING OF EXAMINATION AND TESTING PROCEDURES Procedure Procedure Name Revision Number DRR Number 386HA480 Certificate of Nondestructive 19 N/A

________________ Examination Personnel 19__N/_IA 386HA480 Certificate of Nondestructive Rev.19 Add. I Examination Personnel Procedure for Performing GE-ADM-1 001 Linearity Checks On 4 N/A Ultrasonic Instruments Procedure for Nondestructive Examination Data Review and Analysis of Recorded Indications Procedure for Zero Reference GE-ADM- 1005 and Data Recording for 0 N/A Nondestructive Examinations Procedure for Training and GE-ADM-1025 Qualification of Personnel for N/A GE-NE Specialized NDE Applications Administrative Instruction for GE-ADM-1029 Establishing and Maintaining 2 N/A a Foreign Material Exclusion Area Operational Guidelines for the GE-ADM-1052 Micro-Tomo Ultrasonic Data 0 N/A Acquisition System GE-ADM-1057 Operational Guidelines for the 2 N/A CSI Delivery System Procedure for Installation and GE-ADM-1058 Removal of the CSI (RPV 2 N/A Internal) Core Spray Inspection Tool GE-ADM-1059 Computer Measurements of 2 N/A Digitized Images.

Administrative Procedure for GE-ADM- 1061 Invessel Inspection (IVVI) 0 N/A GE Proprietary

Procedure Procedure Name Revision Number DRR Number Procedure for Determining GE-ADM-1062 and Documenting 0 07-18 Examination Requirements for Risk-Informed Inspections Procedure for Magnetic GE-MT-I100 Particle Examination (Dry 6 06-02 / 06-04 Particle, Color Contrast or Wet Particle. Flourescent)

PDI Generic Procedure for the GE-PDI-UT-I Ultrasonic Examination of 5 07-28 Ferritic Piping Welds PDI Generic Procedure for the GE-PDI-UT-10 Ultrasonic Examination of 2 06-40 Dissimilar Metal Piping Welds PDI Generic Procedure for the GE-PDI-UT-2 Ultrasonic Examination of 4 07-29 Austenitic Pipe Welds PD] Generic Procedure for the GE-PDI-UT-3 Ultrasonic Through Wall 2 N/A Sizing in Pipe Welds Procedure for Liquid Penetrant Examination using GE-PT-100 Flourescent and Visible Dye 5 N/A Liquid Penetrant Inspection Methods Procedure for Ultrasonic GE-UT-I 13 Examination of Babbitted 0 N/A Bearings Procedure for Automated GE-UT-209 Ultrasonic Examination of 18 07-32 Dissimilar Metal Welds, and Nozzle to Safe End Welds Procedure for Automated Flaw Depth Sizing in GE-UT-246 Austenitic and Ferritic Piping 06-03 Welds Procedure for Manual Examination of Reactor GE-UT-300 Pressure Vessel Assembly 10 N/A Welds in Accordance with PDI Procedure for Manual GE-UT-304 Ultrasonic Planar Flaw Sizing 8 N/A in Vessel Materials

Procedure Procedure Name Revision Number DRR Number Procedure for Manual GE-UT-309 Ultrasonic Planar Flaw Sizing 10 N/A of Nozzle Inner Radius and Bore Regions Procedure for Manual Ultrasonic Examination of GE-UT-3 II Nozzle Inner Radius, Bore 15 N/A and Selected Nozzle to Vessel Regions Procedure for Manual Ultrasonic Examination of N/A GE-UT-321 Nozzle Inner Radii and Bore (Non Appendix VIII)

Procedure for the Automated Ultrasonic Examination of GEH-UT-511 Core Spray Piping Welds 16 N/A Contained within the Reactor Pressure Vessel Procedure for Ultrasonic GE-UT-601 Thickness Measurements for I N/A Erosion/ColTosion Procedure for the GE-UT-605 Performance of Thickness and 3 N/A Contour Measurements GE-VT-I101 Procedure for VT-I 2 N/A Examination GE-VT- 103 Procedure for VT-3 5 06-25 Examination Procedure for Invessel Visual VT-CLN-206V7 Inspection (IVVI) of BWR 6 0 N/A RPV Internals Basic-PSA Inc.

BPI-9-XI Nondestructive Examination 2 N/A VT-Personnel Basic-PSA Inc.

TR-954 Operation Procedure for the 2 N/A Barker/Diacon S400NM Snubber Test Machine ER-AA-335-002 Liquid Penetrant Examination 4 N/A Magnetic Particle ER-AA-335-003 Examination N/A ER-AA-335-005 Radiographic Examination 3 N/A ER-AA-335-014 VT-I Visual Examination 4 N/A ER-AA-335-015 VT-2 Visual Examination 9 N/A

Procedure Procedure Name Revision Number DRR Number VT-3 Visual Examination of ER-AA-335-016 Component Supports, 5 N/A Attachments and Interiors of Reactor Vessel VT-3 Visual Examination of ER-AA-335-017 Pump and Valve Internals 5_N/A

SECTION 4 LISTING OF EXAMINATION AND TESTING PERSONNEL Name Job MT/

LI PT/

Li UT /Lvl VT-I/

Lv VT-2/

Li VT-3/

Lv LvI Lv1 Lvl Lvl Lvi Rick Alger FAC Level II Il-L 11 11-L II II 11 Thomas Allen RST Level 11 11-L 11-L Edward Anderson RST Level 11 11-L I1-L Michael Anderson RST Level II II-L II-L Thomas Anderson COE Level III III III Michael Armstrong RF Engineer IJ-L 1I-L Davi Arnaud Manual Level I I1-L 11 11 1I I1 II Ellis P. Bailey COE Level III III III Allen Balcom RST Level II I-L II-L Charles Barrett CSI Data Analyst HIl - PDI Jason Bates CS] Operator 11 Nathan Boyett RST Level II - Fuel I1-L 11-L Timothy Bryan SMART Level I I-T Mike Bullen BOP Level 11 I1 1l 11 - PDI II 11 1I Billy Burns Containment Lvl. II I-L 1I I-L II II II Doug Clayton RST Level II II-L II-L Chad Collins Manual Level I I-T Chad Congdon Manual Level I I-L II II-L II I1 II Steve Cox Manual Level 11 1l-L I1 11 - PDI II 11 II Chris Danson BOP Level I1 I-L 11 I1-L II 11 II Joel Davis RST Level 1I I-L II-L Ed Doucette FAC Level II Il-L Ron Downer FAC Lead I-L 11 I1-L George DuBose Project Level III III 1II IlI - PDI Billy Jac DuLong RST Level 11 II-L 1I-L Mike Duncan RST Level II II-L II-L Lance Eiler Turbine Level 11 II II 1-L II II II Scott Erickson Project Level III III III III III Ill III Allan Erwin RST Level II - Fuel I1-L II-L Cod), Fish SMART Operator II-L Kevin Fish SMART Lead I-T II - PDI Melissa Fish SMART Level I I-T Jeremy Frana SMART Eqp. Tech. I

Name Job MT/

LU PT/ 1T /Lv VT-1/ VT-2 VT-3/

Lv Ls, U, Lv Lv Mike Ganzen FAC Level 11 II Todd Ginder Manual Level 11 11-L 11 11 - PDI II 11 II Jerry Green IVVI Level Ill Ill-L II1-L Doug Gronewold Turbine Level 1I 11-L II I - PDI 11 II II Ed Hampton Snubber Level I1 I-L II 11 II II II Dustin Herman RST Level 11 1I-L 11-L Tom Higgins RST Level I1 1I-L 1I-L DeWane Hill RST Level II - Fuel 11-L II-L Mark Holloway RST Level 11 11-L II-L George C. Holmes RST Level 11 I1-L 1I-L Phil Hopkins FAC Level I1 I-L 1 I1 1 1 Matt Hoyer CSI Operator I-T I-T I1-L Troy Huhe Manual Level I1 II 1l 11 - PDI I I Mike Jenmiges SMART Operator I1-L 11 11 - PD1 Chris Joffe RST Level 1I - Fuel 11-L ll-L Paul Johnson SMART Data Anal. III - PDI Nabil Kazem RST Level 11 - Fuel 11L 11-L John Kee RST Level 11 - Fuel 11-L 11-L Alan Kelly Manual Level 11 1I 11 II II Il 11 Mike Kemp I-IVVI Level Ifl I- 4 1 1 Il-L t 4-IIl-L Dan Kulkoski RST Level 11 11-L 4 4 1I-L 4 4 4 Bryan Ledbetter RST Level 11 11-L I1-L Eric Lemmons RST Level 11 - Fuel 1I-L _I-L Mike Magyar CS] Equip. Tech. I-T James Martin CS] Equip. Tech. 11-L Shannon McAbee RST Level 11 - Fuel 11-L 11-L Samuel. McCain RST Level 11 - Fuel 11-L 11-L Kent Montgomery Manual Level 11 11 11 - PDI Quinton B. Munn RST Level 1I - Fuel 11-L 11-L Kirkland Nelson SMART Level I 1-T Chad Olson CS] Operator 11-L 11 11 I1 11 11 Rudy Paillaman COE Level III fl] IIl

]an Pedersen FAC Lead 11-L Tammy Peters FAC Level 11 1-T I-T 1l-L Alan Phillips RST Level 11 Ill-L Ill-L Mike Pride FAC Level 11 11 11 l-L Tyler Raymond SMART Operator I Wall), Reid Turbine Level 11 1I-L 11 II II 11 11 Kim Robideau BOP Lead 11 I1 It II II Matt Schmaltz Turbine Level I1 I1 1I I1- PDI II II 11 Dan Schroeder RST Level 11 I1-L 1I-L Tim Scott Containment Lvl. II I1-L I1 II-L 11 II II Tony Seng. SMART Level I I-T

,NW Tony Seng SMART Level I 1-T

MT/ PT! VT-I / VT-2 / VT-3 /

Name Job UT / Lv Lv Lv Lv Lv Lv Alan Sevmore FAC Level 11 11-L John Shea BOP Lead 11 11 11 11 Mike Siever RST Level 11 - Fuel 11-L 11-L Steve Snvder ISI Coordinator 11 11 11 - PDI 11 1 II Josh Stellakis CSI Operator I-T l-T 11-L Robert M. Strong RST Level 11 - Fuel 11-L 1I-L Mikado Teodoro RST Level II 11-L 11-L Keith Trout RST Level 11 II-L 1I-L Jeremy Tuttle FAC Level 11 1 1 II Paul Valden Snubber Level 11 11-L 11 11 - PDI 11 11 I1 Eddie Wall COE Level I11 II-L I1]-L Alvah J. Williams RST Level 11 - Fuel 11-L 11-L Ryan Winney RST Level 11 - Fuel 11-L I-L Steve Woodyard Snubber Level 11 11 11 11-L II 11 11 Dave Antlony 111 111 111 111 I11 III Bill Burke 1 Pat Coyle 11 Joe Cummings 11 Culp Craig 11 I Dave Glenn II Arlton Johnson 11 Dan Mahrt 11 Craig Procarione 11 Primeaux Joe 11 Danny Vanfleet 11 Charles Clark 1I 1 111l III Dave Szymkiewicz I1 Tom Parrent 11 Barreras, Manuel 11 Hambor, Robert 11 Thomas, Norm 11 Kilpatrick, Thomas II

SECTION 5 LISTING OF EXAMINATION AND TESTING EQUIPMENT 181863-03 257502 0106T8 257812 01CWX3 GJ 257804 OOBXWW 05325 257412 00X8B0 07225 257947 0148D5 257560 00HR09 PMarticl 255233 010HD7 04K076 255280 054JWL 92F040 255364 014JWD 05-1351

...... ,"_ _ 06-627 2092 R V B 04-365 8646 PDI ALT 8723 050CJP 9876 J-2318 05 FRPD STD 40-0 05 FRP7

. PTIea r UT-6-0 05 FRPM 0OC05K UT-5-0 05 FRRH 05117K CAL-WLLY-036 22BC-03009 CAL-IlW2-011 5746215656 1...

.CAL-STEP-149 Deý ..... 01OKYV 0IM02K CAL-STEP-102 04-303 05L54K CAL-DEPTH-071 98-158 CAL-RHOM-099 05-146

.... Penetr n 37-1 03-337 0IM07K 04-298 04-315 207001 061487310 207004 061484509 0001357872 031536006 031572811 i i.

Section 6 REPAIR AND REPLACEMENT DATA REPORTS NIS-2 OWNER'S DATA REPORT This section provides a listing of the xx ASME Section XI repairs or replacements performed since the last Summary Report.

All repairs and replacements are of a routine nature. CPS did not identify any flaws during performance of any ISI examination that required a repair or replacement.

CPS utilized Code Case N-416-2 during this reporting period. This Code Case allows the elimination of the hydrostatic testing requirement following welded repair or replacement. Provided some additional NDE is performed and the 1992 Edition of Section III used for examination.

CPS installed a number of modifications including the replacement of service water piping to install vacuum breakers and other manual valves.

Following the listing of repairs or replacements are copies of NIS-2 Owner's Data Reports for all of the Class 1, 2, CS, and MC repairs and replacements which CPS performed during this reporting period. Data reports for any components or parts used in support of those NIS-2's have not been included but are filed with Section XI repair and replacement records.

The records for all Section XI repairs and replacements are available and located in the Clinton Records Vault filed in the respective N-5 system under record 3A.117 entitled ASME System Data Reports.

SECTION 6 REPAIR AND REPLACEMENT

SUMMARY

NIS-2 Number Class Description RF-1 1-001 2 Replaced valve IE51F064 disc.

RF-1 1-002 3 Weld Repair cooler I VXI 3AB pipe flanges.

RF-1 1-003 3 Replaced valve IFC004B disc.

RF-1 1-004 3 Weld Repair diesel heat exchanger I DG13A divider plate and end bell.

RF-1 1-005 3 Weld Repair cooler IVX06CA flanges.

RF-1 1-006 3 Replaced coil on cooler IVX13AA RF-1 1-007 2 Replaced blind flanges per EC 349394 in RD system.

RF-1 1-008 2,3 Replaced seal cooler on RH 'B' pump IEI2CO02B and Class 3 piping on SX side RF-1 1-009 3 Replaced both coolers on IVXI4AA and IVXI4AB and weld repair flanges

.RF-11-010 3 Weld repair flanges on spare cooler.

RF-11-011 3 Weld repair flanges on spare cooler.

RF-1 1-012 3 Replaced relief valve IJAI28A.

RF-1 1-013 3 Refurbish spare cooler.

RF-11-014 3 Replaced valve ISX004B.

RF-11-015 3 Replaced pipingbetween orifices ISXI7MB, 18MB, 19MB, 20 MB and replaced studs and nuts.

RF-1 1-016 3 Replaced load pin on snubber IFC03081S RF-11-017 3 Replaced snubbers 1MS05028S and 1MS10909S and load pin on 1MS05028S.

RF-11-018 3 Replaced snubber IMS30002S and load pin on snubber IMS2601OS.

RF-11-019 1 Replaced snubbers I RT01003S, IRT01035S, &, IRT02084S and load pin on IRT01003 S.

RF-1 1-020 3 Replaced snubbers IRT06009S and IRT06040S.

RF-1 1-021 1 Replaced hydraulic snubber IS101B and load pin on hydraulic snubber IS101C RF-1 1-022 1 Replaced valve 1B21F019 bonnet.

RF-1 1-023 1 Replaced check valve 1B21F032A cover studs and nuts.

RF-1 1-024 2 Replaced relief valve IE12F036.

RF-1 1-025 1 Replaced safety relief valve I B21F041A and outlet flange studs.

RF-11-026 1 Replaced safety relief valve 1B21F041B and outlet flange studs.

RF-1 1-027 1 Replaced safety relief valve 1B21F041C and inlet and outlet flange studs.

RF-11-028 1 Replaced safety relief valve 11B21F041L and inlet and outlet flange studs & nut RF-1 1-029 1 Replaced safety relief valve IB21F047F and outlet flange studs.

RF-1 1-030 1 Replaced safety relief valve IB21F051C and inlet and outlet flange studs & nut:

RF-1 1-031 1 Replaced safety relief valve 1B21F051G and inlet & outlet flange studs & nuts.

RF-1 1-032 1 Replaced safety relief valve I B21F051B and inlet and outlet flange studs.& nut:

SECTION 6

REPAIR AND REPLACEMENT

SUMMARY

NIS-2 Number Class Description RF-1 1-033 1 Replaced seventeen (17) Control Rod Mechanisms (CRDM's)

RF-1 1-034 MC Replaced twenty (20) Drywell head eyebolts and fifty eight (58) Drywell head nuts.

RF-11-035 1 Repaired MSIV 1B21F028A Poppet RF-1 1-036 2 Replacedtrigger assembly of Standby Control Liquid (SLC) valve, 1C41 F004B RF-1 1-037 3 Replaced valve ISXOI4B and studs.

RF-1 1-038 3 Replaced relief valve 1G33F609B.

RF-1 1-039 3 Modified piping and installed vacuum breakers and other manual valves per EC 35800.

RF-1 1-040 3 Modified piping and installed vacuum breakers and other manual valves per EC 349061.

RF-11-041 2 Replaced check valve IC41F033B.

.RF-1 1-042 2 Modified valve I E12FO50B shaft assembly and hing pin cover assembly per EC 339008.

RF-1 1-043 1 Replaced Reactor Recirc Pump B33C001A Seal Assembly including Upper Gland and Seal Holder RF-1 1-044 2 Replaced Relief Valve IC41F029B and portions of Line ISCI IBB-2"

ER-AA-330-009 Revision I ATTACHMENT 4 Page 28 of 35 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Enerciv Co., LLC Data Report No. RF-11-001 Name Date: 9/25/2006 965 Chesterbrook Blvd.. Wavne. PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3. Box 228. Clinton. IL 61727 676922-01 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NRI01 Code Class 1 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda Code Case Component: 1974 Edition S75 Addenda 567, 1622, Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989 Edition, no Addenda (c)Section XI code Cases used None
6. Identification of Components Repaired or Replaced and Replacement Components' Name of Name of Manufacturer National Other Year *Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped V ANCHOR/DARLING E-6214-143-1 NA 1E51F064 1979 Replacement Yes 7.

Description:

Replaced disc

8. Tests Conducted: Hydrostatic D Pneumatic [] Nominal Operating Pressure Other ED Exempt ED Pressure: psi Test Temp:

ER-AA-330-009 Revision 1 Page 29 of 35 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Parts Received as follows:

Disc - Cat ID 0001144914 / UTC 0002731471 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this RIP_ I .- conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp Certificate of Authorization No. N4 A Signed -Date Gi-"'*" ,2006 Ow0 r or Own*'s Dsignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of _CT have inspected the components described in this Owner's Report during the period to 9/25/2006 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furt ermore, neither the Inspector nor his employer shall be liable in any manner for any personal inj ry" ,, ,*"" "

or pa ge or a loss of any kind arising from or connected with this inspection.

(M_ _ 2__ Commissions I- L I-I 4 Inspector's Signature National Board, State, Province, and Endorsements Date S ,200 S

ER-AA-330-009 Revision 4 ATTACHMENT 4 Page 29 of 36 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Enercv Co., LLC Data Report No. RF-11-007 Name Date: 4/16/2007 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3. Box 228. Clinton. IL 61727 793883 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NRD01 Code Class 2 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda NONE Code Case Component: 1974 Edition S74 Addenda NONE Code. Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Section XI 1989 Edition (c)Section XI code Cases used NONE
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped PP ILLINOIS POWER PIPING SYSTEM NA NRD01 1986 Replacement Yes 7.

Description:

Replaced 10" Blind Flanges per EC349394.

8. Tests Conducted: Hydrostatic F- Pneumatic El Nominal Operating Pressure Other 0 Exempt Ej Pressure: psi Test Temp:

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Cat ID Number 1405262 and UTC Number 2727829.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this ,e'pl..c--sen- conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp MI~.A Certificate of Authorization No. W3 IA Signed V Own@ or 4, E-,N Owne,r,:,-esgnee, Title U y; Date 4 - )1 200L CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of CT have inspected the components described in this Owner's Report during the period I 3. c.0 to 4/17/2007 , and state that to the best of my knowledge and belief, the Ow er nas performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furth more, neit er Inspector nor his employer shall be liable in any manner for any personal inju pu b iT(

or pr a ge r a loss of any kind arising from or conneted with this inspection.

__________ ___________Commissions -J- kAFTd4 Inspector's Signature/-- National Board, State, Province, and Endorsements Date 1-7 A 1P*Tu) , 20_.L_

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Enerqy Co., LLC Data Report No. RF-11-008 Name Date: 4/18/2007 965 Chesterbrook Blvd.. Wayne. PA 19087 Address Sheet I of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3, Box 228, Clinton, IL 61727 794661 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NRH08, NSX04 Code Class 2,3 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda N/A Code Case Component: 1971 Edition - S73 Addenda 1567 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Section XI 1989 Edition (c)Section XI code Cases used N-416-2
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped Seal Coole Byron Jackson 214921 N/A SI. Co.1E12-C002B 1978 Replacement Yes PP ILLINOIS POWER PIPING SYSTEM N/A NSX04 1986 Replacement Yes 7.

Description:

Replaced Seal Cooler on RHR "B" pump 1E12-C002B and Class 3 piping on Service Water (SX) side.

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Other Dl Exempt ED Pressure: psi Test Temp:

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Seal Cooler: Cat ID Number 0001150931; UTC Number 0002104998 Pipe: Cat ID Number 1153243; UTC Number 2115725 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this _ __ _ _ -conform to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp __-_ I A, Certificate of Authorization No. i-J i A Signed A -c ý*ý- -- tE -*,- Date 2 0 __ 2001 OwneK.o Ov ffre'fs-Desiklnee, Title \J CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of _CT have inspected the components described in this Owner's Report during the period i/0 01 to 5/3/2007 , and state that to the best of my knowledge and belief, the Ow er hlas performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermor neither- qspector nor his employer shall be liable in any manner for any personal injury or prope d c, c or of an,, kincd arising from or connecsed with this inspection.

orprope d o / of anykifCommissionsn dit si .

Inspector'" Signatur., National Board, State, Province, and Endorsements Date _- 'it ,20_VL/

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Enerqy Co., LLC Data Report No. RF-11-019 Name Date: 12/11/2007 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet 1 of
2. Plant: Clinton Power Station Unit: 1 Name RR3, Box 228, Clinton, IL 61727 770520-07, 14, & 16 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NRT03 Code Class I 5(a) Applicable Construction Code Pipe: 1974 Edition Su 1974 Addenda N/A Code Case Component: 1974 Edition Su 1974 Addenda N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used N/A
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped Snubber Pacific Scientific 11290 N/A 1RT01003S 1985 Replacement Yes Snubber Pacific Scientific 24424 N/A 1RT01035S 1985 Replacement Yes Snubber Pacific Scientific 19710 N/A 1RT02084S 1985 Replacement Yes 7.

Description:

1RT01003S - Replaced Snubber & Load Pin; 1RT01035S - Replaced Snubber; 1RT02084S - Replaced Snubber.

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure El Other Z Exempt [] Pressure: psi Test Temp: oF

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

For 1RT01003S - For Snubber - Cat ID 1151214, UTC # 2108602 For Load Pin - Cat ID 1152581, UTC # 2116868 For 1RT01035S - For Snubber - Cat ID 1141214, UTC # 2113644 For 1RT02084S - For Snubber - Cat ID 1151955, UTC # 2110225 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Re ic&L-r,-e n + conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp l I A Certificate of Authorization No. r.4 I A Signed --. E. -,-S CDate v. - fl ,200-7 t rier or"O-w_.er'If Designee, Ti(lke CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of CT have inspected the components described in this Owner's Report during the period

- */ to 12/11/2007 ,and state that to the best of my knowledge and belief, the O ne has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the exam)nations and corrective measures described in this Owner's Report.

Furthermore, neither/me Isector nor his employer shall be liable in any manner for any personal injury.(

or prope rtyg{/geý'oraja ss of any kind arising from or connected with this inspection.

  • ,'/* LCommissions

/ y :L-rI1I Inspector's Signature National Board, State, Province, and Endorsements Date ,20 0

ER-AA-330-009 Revision 4 Page 30 of 39 ATTACHMENT 3 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Enerqy Co., LLC Data Report No. RF-11-021 Name Date: 12/13/2007 965 Chesterbrook Blvd.. Wayne. PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station ,Unit: 1 Name RR3, Box 228, Clinton, IL 61727 770520-05 & 17 Address Repair Organization P.O. No., 3ob No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NGE02 Code Class 1 5(a) Applicable Construction Code Pipe: I 974 Edition Su 1974 Addenda N/A Code Case Component: 1'974Edition Su 1974 Addenda N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used N/A
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped Snubber E-System 008E30 N/A 1S101B 1986 Replacement Yes Snub E-Systemr 004E070 N/A iSloiC 1986 Replacement Yes 7.

Description:

1SI01B - replaced snubber; IS101C - replaced load pin.

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Dl Other Li Exempt RJ Pressure: psi Test Temp:

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

For IS101B - For snubber Cat ID 1153940 UTC # 2727064 For 1SI01C - For load pin Cat ID 1152721 UTC # 2118078 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Repleoi-?,& conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp tIA Certificate of Authorization No. 01A Signed -A%ýýo, 7 f,,f-le-v Date  %-L - ,200-7

((eror..Oýntrs Designee,U~itle CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by -the National Board of Boiler and Pressure Vessel Insp ctors and the State of Province of Illinois and employed by Hartford Steam Boiler of C_ f have inspected the components described in this Owner's Report during the period 1 l( to 12/13/2007 , and state that to the best of my knowledge and belief, the Ovnef has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the exa nations and corrective measures described in this Owner's Report.

FurthermhreIe pector nor his employer shall be liable in any manner for any personal injury or propet d* i e Las of any kind arising from or conne ted with this inspection.

______ _ __"_ __ _Commissions ____-__7QI

]nspector's Signature ,* National Board, State, Province, and Endorsements Date I$ (' Zje, %<L ,20_1k_

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Enerav Co., LLC Data Report No. RF-11-022 Name Date: 2/21/2008 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3. Box 228. Clinton. IL 61727 676923-01 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NMS06 Code Class 1 5(a) Applicable Construction Code Pipe: N/A Edition N/A Addenda N/A Code Case Component: 1974 Edition S75 Addenda see remark Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Section XI, 1989 Edition (c)Section XI code Cases used N/A
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of
  • I Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped V ANCHOR/DARLING E-6214-156-1 NA 1B21F019 1979 Replacement Yes 7.

Description:

Replaced Valve Bonnet

8. Tests Conducted: Hydrostatic E Pneumatic El Nominal Operating Pressure Other El Exempt 0 Pressure: psi Test Temp:

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Component Code Cases: 1516.1, 1567, 1622, 1635.1, 1677 Valve Bonnet Cat ID 1145102 UTC 2113548 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Rv ko\ck ve "-, conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp PJJA Certificate of Authorization No. NiA Signed "*,'Ytr wpEn v\,t -k Date -L- 21 - ,200t Own Vrlr Oww4&e iee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of _CT i . have inspected the components described in this Owner's Report during the period Sl/ 3 /c 7 to 2/22/2008 . and state that to the best of my knowledge and belief, the Owner hal performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither th Ins 'ector nor his employer shall be liable in any manner for any personal injury (-* (

or propertW.d*$ra'ýie ora ss of any kind arising from or connected with this inspection.

/ Commissions / -7 IQ I Inspector's Signature National Board, State, Province, and Endorsements Date DD P,.-_1 ,20_

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Energy Co., LLC Data Report No. RF-11-023 Name Date: 2/22/2008 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet I of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3. Box 228. Clinton. IL 61727 2647 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NFW01 Code Class 1 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda NONE Code Case Component: 1974 Edition 575 Addenda see remark Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Section XI, 1989 Edition (c)Section XI code Cases used N/A
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped V ANCHOR/DARLING E-6214-157-1 NA 1B21F032A 1979 Replacement Yes 7.

Description:

Replaced Valve Cover Studs and Nuts.

8. Tests Conducted: Hydrostatic ED Pneumatic El Nominal Operating Pressure Other L] Exempt El Pressure: psi Test Temp:

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Component Code Cases: 1516.1,1567,1622,1635.1, 1677.

Valve Cover Studs - Cat ID 1151852 UTC 0002100839 Valve Cover Nuts - Cat ID 1152022 UTC 0002684458 CERTIFICATE OF COMPLIANCE We certify that the statements made. in the report are correct and this conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NI Certificate of Authorization No. N IA Signed VA i 5*.,V,'vt.4* - Date 2-. -L2- ,200_2 Owoe or OwnerUD+ignee, Title \l CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of _CT i / have inspected the components described in this Owner's Report during the period

-I I-0 I to 2/22/2008 , and state that to the best of my knowledge and belief, the Ow er h s performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermoreneither e Inspector nor his employer shall be liable in any manner for any personal injury 1 c' or propertdcfa4 or a los( of any kind- arising from or connected with this inspection.

r I/I Ins ector's Si nature Commissions :: L I -) AI National Board, State, Province, and Endorsements Date fC6*JA--*,-'-r , 20Y

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Energy Co., LLC Data Report No. RF-11-024 Name Date: 3/5/2008 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet 1 of I
2. Plant: Clinton Power Station Unit: 1 Name RR3, Box 228, Clinton, IL 61727 618967 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NRH01 Code Class 2 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda Code Case Component: 1977 Edition S1977 Addenda N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used N/A
6. Identification of Components Repaired or Replaced and Replacement Components Name of , Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification ,Built Replaced or Code Replacement Stamped V Dresser lndustries N99652 N/A 1E12F036 1983 Replacement Yes 7.

Description:

Replaced relief valve.

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Other ED Exempt D Pressure: psi Test Temp:

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Cat ID # 1389487; UTC # 2705825 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Replloe-r conform to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp WIA Certificate of Authorization No. W4A Signed c-k*%* nt Date 'IS- - ,20OO Own r~r Owner's Dqsignee, Title V CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of __CT have inspected the components described in this Owner's Report during the period cl ) to 3/5/2008 , and state that to the best of my knowledge and belief, the Owner,las performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore either e Inspector nor his employer shall be liable in any manner for any personal injury -

or propertya a), *eor 6Is of any kind arising from or connected with this inspection.

___________/_______Commissions i-c _

Inspecor's Signature ,-. National Board, State, Province, and Endorsements Date (1 l RC-kA

-* ,20 U'6

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Enerqy Co., LLC Data Report No. RF-11-025 Name Date: 3/7/2008 965 Chesterbrook Blvd.. Wavne. PA 19087 Address Sheet 1 of
2. Plant: Clinton Power Station Unit: 1 Name RR3, Box 228, Clinton, IL 61727 951348 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NGE02 Code Class 1 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda N/A Code Case Component: 1974 Edition S76 Addenda NONE Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used NONE
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped V DIKKERS 160539 44 1B21F041A 1978 Replaced Yes 7.

Description:

Replaced Safety relief Valve and outlet boltings (2).

8. Tests Conducted: Hydrostatic El Pneumatic ED Nominal Operating Pressure Other ED Exempt ED Pressure: psi Test Temp: oF

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Boltings - Cat ID - 1145888 UTC 2684460.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Rep) v-t.,-,i conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp A Certificate of Authorization No. P,% IA Signed 0 Owner t-A*y* Title or 1*ner's~rn e, Title Date 'I - " , 200-UJ CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of _CT have inspected the components described in this Owner's Report during the period fC/ I to 3/7/2008 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury f* r/

or pr*i arne or a loss of any kind arising from or connected with this inspection.

' I (1 Commissions -L_*_III Inspector's Signature , National Board, State, Province, and Endorsements Date lIA,*-Q, I ,20QL

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Enerav Co.. LLC Data Report No. RF-11-026 Name Date: 3/7/2008 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet I of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3. Box 228. Clinton. IL 61727 951351 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NGE02 Code Class 1 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda N/A Code Case Component: 1974 Edition S76 Addenda NONE Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used NONE
6. Identification of Components Repaired or Replaced and Replacement Components 6.Name Identification of Components Repaired or Replaced and Replacement Components of Name of Manufacturer National Other Year Repaired ASMF Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped V DIKKERS 160787 55 1 B21 F041 B 1978 Replaced Yes 7.

Description:

Replaced Safety Relief Valve and outlet flange bolting.

8. Tests Conducted: Hydrostatic E) Pneumatic [] Nominal Operating Pressure Other E Exempt E . Pressure: psi Test Temp:

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

5 Outlet studs were replaced and Cat ID & UTC numbers were not recorded by contractor (Shaw).

See Issue Report 751868.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this R-9 conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp NN\ IN Certificate of Authorization No. M1iA, Signed NAk.r, Owner* Ownrlm"S-sg t 't Date - 9 ,0_ 0 nee, Titleq CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois of CT / /

and employed by Hartford Steam Boiler_

have inspected the components described in this Owner's Report during the period CI(/C/-J to 3/21/2008 , and state that to the best of my knowledge and belief, the Owner ýas performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the exanpinations and corrective measures described in this Owner's Report.

Furthermorer neither theJ-Insector nor his employer shall be liable in any manner for any personal injury or prope 7/ (a / e or /acss 4 of any kind arising from or connected with this inspection.

Commissions -T L V"kn.

Inspector's Signature National Board, State, Province, and Endorsements Date i If hl A\Th( , 20 P - N

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Energy Co., LLC Data Report No. RF-11-027 Name Date: 3/7/2008 965 Chesterbrook Blvd.. Wavne. PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3, Box 228, Clinton, IL 61727 772160 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type-Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NGE02 Code Class 1 5(a) Applicable Construction Code Pipe: 1974 Edition S75 Addenda none Code Case Component: 1974 Edition S76 Addenda none Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used none
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped V DIKKERS 160940 54 1B21F041C 1978 Replaced Yes 7.

Description:

Replaced Safety Relief Valve and inlet and outlat flange studs.

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Other E Exempt El Pressure: psi Test Temp: OF

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Inlet Studs - Cat ID 1145887 UTC 2734814 (6 each) and 2111761 (1 each)

Inlet Nuts - Cat ID 1406870 UTC 2784266 (5 each) and 2727464 (7 each)

Outlet Studs - Cat ID - 1145888 UTC 2684460 (16 each)

Outlet Nuts - Cat ID - 1406887 UTC 2727476 (16 each)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this w."-,- 4 conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp Al,A Certificate of Authorization No. ).sIA Signed týo- N eowjrOwn".

&"--Y ignee, Titleq- Date "--1 20-0&

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of __CTI have inspected the components described in this Owner's Report during the period 5 h- /0 to 3/14/2008 , and state that to the best of my knowledge and belief, the Owneý hAs performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the nspIctor nor his employer shall be liable in any manner for any personal injury a s kind or property ýmcr a lo s f any kind arising from or connected with this inspection.

ii tIlJ // *--- Commissions *-Il*--

Inspector's Signature National Board, State, Province, and Endorsements Date 'I

  • n _k , 20 ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI
1. Owner: AmerGen Enerav Co.. LLC Data Report No. RF-11-028 Name Date: 3/12/2008 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3. Box 228. Clinton. IL 61727 951353 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NGE02 Code Class 1 5(a) Applicable Construction Code Pipe: 1974 Edition ýS74 Addenda N/A Code Case Component: 1974 Edition S76 Addenda NONE Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used NONE
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ,ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped V DIKKERS 160535 40 1B21FO41L 1978 Replaced Yes 7.

Description:

Replaced Safety relief Valve and Studs & Nuts.

8. Tests Conducted: Hydrostatic ED Pneumatic L- Nominal Operating Pressure 0

Other LZ Exempt El Pressure: psi Test Temp: F,

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Inlet Nut - Cat ID - 1406870 UTC # 2784266 (1 each)

Outlet Studs - Cat ID 1145888 UTC #s 2728985 (4 each) & 2684456 (1 each)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this _____ __ "t_ conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp gJlP Certificate of Authorization No. AI A

Signed l.'v(s y

  • Date "-5-i- ,20oL Own&Jor OwnK"sDe~ignee, Title 0 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of _CT / I have inspected the components described in this Owner's Report during the period

- i I(

  • {i~ to 3/14/2008 , and state that to the best of my knowledge and belief, the Owne h s performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermoge, neitther the Inspector nor his employer shall be liable in any manner for any personal injury (\,

or prope: , ,/, i1. loss .of any kind arising from or connected with this inspection.

Commissions _ _ _ _ _ _ _ _

Inspector's Signature

  • National Board, State, Province, and Endorsements Date ) / -Q , ,20_j_

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Energy Co., LLC Data Report No. RF-11-029 Name Date: 3/12/2008 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3. Box 228. Clinton. IL 61727 951356

.Address Repair Organization P.O. No., Job No.

3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NGE02 Code Class 1 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda N/A Code Case Component: 1974 Edition S76 Addenda NONE Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used NONE
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped V DIKKERS 160781 50 1B21F047F 1978 Replaced Yes 7.

Description:

Replaced Safety Relief Valve and Outlet Studs.

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Other El Exempt D1 Pressure: psi Test Temp:

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Outlet Studs - Cat ID - 1145888 UTC #s 2684456 (2 each) & 2684460 (4 each).

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this _,\__c. "e_-t conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp %\-N A J Certificate of Authorization No. 141 A Signed " ,* B It-It I Date - L - ,'20ok__

OwQ. or G3wnr`ff Designee, TitV CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of _CT I I have inspected the components described in this Owner's Report during the period 5 / i oi f to 3/12/2008 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermor(n~e .ther th Infsp-'e r nor his employer shall be liable in any manner for any personal injury or property dang r a ss' nY kind arising from or connected with this inspection.

____Commissions :f L Inspector's Signature ,,-7 National Board, State, Province, and Endorsements Date fJ , 20_(

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Enercv Co., LLC Data Report No. RF-11-030 Name Date: 3/12/2008 965 Chesterbrook Blvd.. Wavne. PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3, Box 228, Clinton, IL 61727 951837 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NGE02 Code Class 1 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda N/A Code Case Component: 1974 Edition S76 Addenda NONE Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used NONE
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement' Stamped V DIKKERS 160786 53 1B21F051C 1978 Replaced Yes 7.

Description:

Replaced Safety Relief Valve and Studs and Nute.

8. Tests Conducted: Hydrostatic El Pneumatic 1:1 Nominal Operating Pressure Other ED Exempt E Pressure: psi Test Temp: OF

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Inlet Nut - Cat ID - 1406870 UTC # 2784266 (1 each)

Outlet Studs - Cat ID - 1145888 UTC # 2684460 (8 each)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Rtp, .*ev,, conform to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp MIA Certificate of Authorization No. N I A Signed M, ý 2, J., §:2ý E',I; V\ Date "-S 2..- ,20oC Owne~r Owner-*s gnee, Title V CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Ins ectors and the State of Province of Illinois and employed by Hartford Steam Boiler of __ have inspected the components described in this Owner's Report during the period Slto 3/12/2008 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither th, -n*pector nor his employer shall be liable in any manner for any personal injury (\,

iorprrope(*..o af-i I

pro o 'ali ec*L'V of any kind arising from or connected with this inspection.

Commissions "

Inspector's Signature . National Board, State, Province, and Endorsements Date i-(R2c* , , 20_.

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Energy Co., LLC Data Report No. RF-11-031 Name Date: 3/12/2008 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3, Box 228, Clinton, IL 61727 772185 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NGE02 Code Class 1 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda N/A Code Case Component: 1974 Edition S76 Addenda . NONE Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used NONE
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped V DIKKERS 160794 59 1B21F051G 1978 Replaced Yes 7.

Description:

Replaced Safety Relief Valve and Studs and Nuts.

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Other D1 Exempt ED Pressure: psi Test Temp:

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Inlet Studs - Cat Id - 1145887 UTC #s 2111755 (12 each)

Inlet Nuts - Cat ID 1406870 UTC #2727464 (12 each)

Outlet Nuts - Cat ID 1406887 UTC # 2784267 (16 each)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and thisg Q¶A

  • V,,1 conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp )41 A Certificate of Authorization No. N A Signed MN&h. &EL*fn_*. Date I .12- ,200_R_

Owrn or Owner-ýs-D-eignee, Title U CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of __CT ) have inspected the components described in this Owner's Report during the period

"- to _ 3/14/2008 _ , and state that to the best of my knowledge and belief, the Owner ha's performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither th e n p'ctor nor his employer shall be liable in any manner for any personal injury or propertdrd :a s of any kind arising from or connected with this inspection.

_____________________Commissions i C,' ID *-

Inspector's Signature National Board, State, Province, and Endorsements Date " i

  • 1 ,20_M

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Energy Co., LLC Data Report No. RF-11-032 Name Date: 3/12/2008 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3. Box 228. Clinton. IL 61727 772212 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NGE02 Code Class 1 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda N/A Code Case Component: 1974 Edition S76 Addenda NONE Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used NONE
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped V DIKKERS 160784 56 1B21F051B 1978 Replaced Yes 7.

Description:

Replaced Safety Relief Valve and Studs and Nuts.

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Other El Exempt El Pressure: psi Test Temp:

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Inlet Studs - Cat ID 1145887 UTC #s 2111755 (3 each) & 2728986 (9 each)

Inlet Nuts - Cat ID 1406870 UTC # 2784266 (12 each)

Outle Studs - Cat ID 1145888 UTC # 2684460 (12 each)

Outlet Nuts - Cat ID 1406887 UTC # 2784267 (16 each)

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Reipl)v ce,--*,t,-,t-conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N I A.

Certificate of Authorization No. N ) A Signed tk.-

Owner(* owner' *Denee, Title U Date ,20 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of CT I / have inspected the components described in this Owner's Report during the period 17*ý q 0,-c to 3/14/2008 , and state that to the best of my knowledge and belief, the Owner ha's performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the ns 'ector nor his employer shall be liable in any manner for any personal injury or propertoadpge oral-I of any kind arising from or connected with this inspection.

7111}. I*

/

  • Commissions L L* 7 Inspector's SignatuFe National Board, State, Province, and Endorsements Date H tAQ,*:A ,20

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Enermv Co., LLC Data Report No. RF-11-033 Name Date: 3/14/2008 965 Chesterbrook Blvd.. Wavne. PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3, Box 228, Clinton, IL 61727 929184; 1thru 17 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NGE01 Code Class 1 5(a) Applicable Construction Code Pipe: N/A Edition N/A Addenda N/A Code Case Component: 71 Edition S73 Addenda ae Remarks Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used N/A
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped T CB&I Various Various 1B13D008 1978 Replaced Yes 7.

Description:

Replaced seventeen (17) Control Rod Mechanisms (CRDM's)

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Other ED Exempt ED Pressure: psi Test Temp:

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Code Cases for construction code - 1141, 1332, 1361-2, 1557-1, N207.

See Continuation sheet for material procurement data.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this "Rcj"l t t-. conform to the rules of the ASME Code, Section XI. repair or replacement Type Code Symbol Stamp [lJfA Certificate of Authorization No. W I A Signed owr ej or Owner' A , ý !>:1, §!¢:=

. 0inee, Tilte Date 3 -Aý- I ,200a CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of CT have inspected the components described in this Owner's Report during the period 35/ ý to 3/18/2008 - , and state that to the best of my knowledge and belief, the 0 ner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal inju >7..

or prope. aMag 7 or loss of any kind arising from or conncted with this inspection.

________" ______" ______Commissions J1--L /7

  • Inspector's Signature National Board, State, Province, and Endorsements Date i fl'*-"z.L\ ,20 C,

NIS-2 RF-11-33 (cont.) Page 3 of 3 Work Order 929180 Tasks I thru 17 CRDM Replacement Task, Location CRDM Replacement Serial Number & UTC; Associated Bolting Cat ID & UTC Task 01 20-05 A3284 & UTC 2744588; Cat ID-1147766 & UTC 2735956 Task 02 24-09 A2531 & UTC 2744597; Cat ID-1147766 & UTC 2735956 Task 03 36-09 A2441 & UTC 2744599; Cat ID-1147766 & UTC 2735956 Task 04 40-09 A2681 & UTC 2744605; Cat 1D-1147766 & UTC 2735956 Task 05 16-13 8970 & UTC 2744589; Cat ID-1147766 & UTC 2735956 Task 06 32-13 7760 & UTC 2744600; Cat ID-1147766 & UTC 2735956 Task 07 08-17 A2606 & UTC 2744602; Cat ID-1 147766 & UTC 2735956 Task 08 28-17 8183 & UTC 2744586; Cat ID-1147766 & UTC 2735956 Task 09 08-21 8938 & UTC 2744595; Cat ID-1 147766 & UTC 2735956 Task 10 48-21 A3267 & UTC 2744590; Cat ID-1147766 & UTC 2735956 Task 11 28-25 A2687 & UTC 2744587; Cat ID-1147766 & UTC 2735956 Task 12 48-25 8151 & UTC 2744604; Cat ID-1147766 & UTC 2735956 Task 13 32-29 9000 & UTC 2744591; Cat ID-1147766 & UTC 2735956 Task 14 44-33 A2591 & UTC 2744603; Cat ID-1147766 & UTC 2735956 Task 15 36-49 A3341 & UTC 2744601; Cat ID-1147766 & UTC 2735956 Task 16 44-49 A3347 & UTC 2744593; Cat ID-1147766 & UTC 2735956 Task 17 32-53 8651 & UTC 2744606; Cat ID-1147766 & UTC 2735956

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen EnerQv Co., LLC Data Report No. RF-11-034 Name Date: 3/25/2008 965 Chesterbrook Blvd.. Wavne. PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3, Box 228, Clinton, IL 61727 910943-11 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: IWE/IWL Code Class MC 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda N/A Code Case Component: 1974 Edition S76 Addenda N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1992 Ed 1992 Addenda (c)Section XI code Cases used N/A
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped Vessel Chic, Bridge &Iron N/A N/A Drywell 1977 Replaced No 7.

Description:

Replaced twenty (20) Drywell head Eyebolts and fifty eight (58) Drywell head Nuts.

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Other I] Exempt W Pressure: psi Test Temp: OF

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Drywell Head Eyebolts - Cat ID 1388929 UTC 2788428 (13 each) and 2795540 (7 each).

Drywell Head Nuts - Cat ID 1148025 UTC 2795845 (58 each).

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this &tY'tf'i conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp t.4(A Certificate of Authorization No. ___ _lI Signed -9ý El-*i-'\,*" Date -s - .i . 20_.__

Ownu or Owza..*s D~signee, Titl CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of CT I have inspected the components described in this Owner's Report during the period I -/.2a/ -7*. to 3/25/2008 , and state that to the best of my knowledge and belief, the Owner ha performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermfý!> neithýrfh Inspector nor his employer shall be liable in any manner for any personal injury / o-or prope d cor ss of any kind arising from or conn 9 cted with this inspection.

____________ C Commissions -i_' c I O)D" Inspector's Sigrture -- National Board, State, Province, and Endorsements Date

  • il ,iz.-t*, , 20.J

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Energy Co., LLC Data Report No. RF-11-035 Name Date: 3/31/2008 965 Chesterbrook Blvd.. Wayne. PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3, Box 228, Clinton, IL 61727 2667 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NGE02 Code Class 1 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda N/A Code Case Component: 1974 Edition None Addenda 1622 Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used N/A
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component -Manufacturer Serial Number Board No Identification Built 'Replaced or Code Replacement Stamped V ATWOOD & MORRILL 5-562 NA 1B21F028A 1976 Repaired Yes 7.

Description:

Repaired Poppet by welding.

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Other D] Exempt ED Pressure: psi Test Temp:

I ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this Rtz'c, v- conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp m1A Certificate of Authorization No. 14IA Signed VA% e .. Date _,200Z, Ow*,LrrOwrw.o:rs*ignee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler @

of __CT have inspected the components described in this Owner's Report during the period

  • ) I I k1 -- to 3/31/2008 , and state that to the best of my knowledge and belief, the Own&r h s performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the4npector nor his employer shall be liable in any manner for any personal injury or prope ,rty ge or a issof any kind arising from or conncted witt this inspection.

....___ __.____ ______ Commissions I-Lý' )

Inspector's Signature, National Board, State, Province, and Endorsements Date I *? APL-. ,20, 0

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Energy Co., LLC Data Report No. RF-11-036 Name Date: 3/31/2008 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3. Box 228. Clinton. IL 61727 706218 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NSC01 Code Class 1 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda NONE Code Case Component: 1977 Edition S77 Addenda NONE Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used NONE
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped V CONAX 70 N/A 1C41F004B 76 Replaced Yes CORPORATION No 7.

Description:

Replace Trigger Assembly of Standby Liquid Control (SLC) valve, 1C41F004B, after firing.

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Other ED Exempt ED Pressure: psi Test Temp: 0F

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Code replacement Parts Reciept Information:

Trigger Assembly - Cat ID 1148279, UTC 2783549. It consists of:

Ram S/N 1782, Trigger Body S/N 7365, and Inlet Fitting S/N 7390.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this$*e?\ vn,",%ý conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp rQ A Certificate of Authorization No. N A Signed - y' -* *3o ntY Date : - - 20_

Ow*,Jor Ownera!Osignee, Title '4 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspect rs and the State of Province of Illinois and employed by Hartford Steam Boiler of __CT have inspected the components described in this Owner's Report during the period

- 0 to 4/1/2008 _ , and state that to the best of my knowledge and belief, the Owned has'performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property d a loss of any kind arising from or connected with this inspection.

Commissions j IT" i Inspector's Signature , National Board, State, Province, and Endorsements Date I AprIL- ,20U)-

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Energy Co., LLC Data Report No. RF-11-041 Name Date: 4/8/2008 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet 1 of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3. Box 228. Clinton. IL 61727 676052 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NSC01 Code Class 2 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda N/A Code Case Component: 1977 Edition W77 Addenda N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used N-416-2
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped V YARWAY 94BKG NA 1C41F033B 1982 Replaced Yes 7.

Description:

Replaced the check valve.

8. Tests Conducted: Hydrostatic F] Pneumatic F-1 Nominal Operating Pressure Se Other 0 Exempt 0 Pressure: psi Test Temp:

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Receiving information:

Check Valve Cat ID 1145361; UTC 2798854.

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this ___ -,_,_ conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp ,flA Certificate of Authorization No. W4)A Signed tA\OvviJ

-iý._n or Ow~wner's Dpsignee, Title re Date , 20_2ý CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois of _CT 1 and employed by Hartford Steam Boiler_

have inspected the components described in this Owner's Report during the period W

, 1?5I

  • to 4/9/2008 , and state that to the best of my knowledge and belief, the Owne h s performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither t ns ector nor his employer shall be liable in any manner for any personal injury or prope ry dan or a lo any kind arising from or connected with this inspection.

________________ ___________ Commissions *J..L ll3j Inspector's Signature National Board, State, Province, and Endorsements Date ,20 20 IS

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Energy Co., LLC Data Report No. RF-11-042 Name Date: 4/9/2008 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet I of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3, Box 228, Clinton, IL 61727 502169 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NRH03 Code Class 2 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda Code Case Component: 1974 Edition S75 Addenda ýe Remarks Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used N/A
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped V ANCHOR/DARLING E-6214-123-1 NA 1E12F050B 1979 Replacement Yes 7.

Description:

Modified Valve Shaft Assembly and Hing Pin Cover Assembly per EC 339008.

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure W Other ED Exempt E] Pressure: psi Test Temp:

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

ASME Sec III Code Cases - 1516.1, 1567, 1622, 1635.1, 1677.

Receiving information:

Bonnet Cover - Cat ID 1395171; UTC 2727794 Bonnet Cover Bolt - Cat ID 1395216; UTC 2687743 Hing Pin Cover - Cat ID 1395171; UTC 2727794 Hing Pin Cover Studs - Cat ID 1151829; UTC 2112217 Hing Pin Cover Studs - Cat ID 1396489; UTC 2723839 Hing Pin Cover Nuts - Cat ID 1145422; UTC 2115663 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and'this Rep_____,_, _ conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp w JA, Certificate of Authorization No. N) A, Signed V-k-i ýý, *; p t-V,* r*e ,rDate 4 -. - 200D' O0lr or Owper' Designee, Tit@

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of __CT- have inspected the components described in this Owner's Report during the period If 'f to 4/10/2008 _. , and state that to the best of my knowledge and belief, the Owner hasiperformed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his. employer shall be liable in any manner for any personal injury or property a.T e *r dlls of any kind arising from or connected with this inspection.

________________Commissions ** LAII] L\

Inspector's Jign ure "I National Board, State, Province, and Endorsements Date / AfV&

' .L ,20 (*__6

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Enerqy Co., LLC Data Report No. RF-11-043 Name Date: 4/16/2008 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet I of 1
2. Plant: Clinton Power Station Unit: 1 Name RR3, Box 228, Clinton, IL 61727 798333 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address 4.. Identification of System: NGE01 Code Class 1 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda NONE Code Case Component: 1971 Edition W73 Addenda NONE Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used NONE
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped P BINGHAMIWILLAMETTE 14217101 NB-394 1B33C001A 1977 Replacement Yes 7.

Description:

Replaced Pump Seal Assembly includes Upper Gland and Seal Holder.

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Other ED Exempt EI Pressure: psi Test Temp:

ER-AA-330-009 Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section X1

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Upper Gland - National Board # 1475 Seal Holder - National Board # 1492 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this e'*v-v* conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp N IA, Certificate of Authorization No. 'M(A Signed ýA y' F ,-!" Date  %~16 20oQj Own drr Ownert-D-ekignee, Title U CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of Illinois and employed by Hartford Steam Boiler of _CT have inspected the components described in this Owner's Report during the period

" To--0) to 4/16/2008 ,and state that to the best of my knowledge and belief, the Ownbr hds performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the ex minations and corrective measures described in this Owner's Report.

Furthermore, neither the Spector nor his employer shall be liable in any manner for any personal injury" ,,- //

or pree p-i(d/*m age or/loss of any kind arising from or connected with this inspection.

_______ /_____ .________ Commissions L t ( k Inspector's Signature National Board, State, Province, and Endorsements Date i- -*k -TL L. ,20_f j_

ER-AA-330-009 Revision 4 ATTACHMENT 3 Page 30 of 39 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner: AmerGen Energy Co., LLC Data Report No. RF-11-044 Name Date: 4/16/2008 965 Chesterbrook Blvd., Wayne, PA 19087 Address Sheet 1 of I
2. Plant: Clinton Power Station Unit: 1 Name RR3, Box 228, Clinton, IL 61727 706151 Address Repair Organization P.O. No., Job No.
3. Work Performed by: Clinton Power Station Type Code Symbol Stamp: None Name Authorization No: Not Applicable RR3, Box 228, Clinton, IL 61727 Expiration Date: Not Applicable Address
4. Identification of System: NSC01 Code Class 2 5(a) Applicable Construction Code Pipe: 1974 Edition S74 Addenda N/A Code Case Component: 77 Edition S77 Addenda N/A Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements ASME Sec XI 1989 Ed, No Add (c)Section XI code Cases used N-416-2
6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer National Other Year Repaired ASME Component Manufacturer Serial Number Board No Identification Built Replaced or Code Replacement Stamped V Crosby N99660-00-0001 N/A 1C41F029B 83 Replacement Yes 7.

Description:

Replaced the Relief Valve 1C41F029B and portions of line 1SC11BB-2".

8. Tests Conducted: Hydrostatic El Pneumatic El Nominal Operating Pressure Other ED Exempt El Pressure: psi Test Temp:

ER-AA-330-009 -

Revision 4 Page 30 of 36 ATTACHMENT 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

9. Remarks (Applicable Manufacturer's Data Reports to be attached):

Receiving information:

Relif Valve - Cat ID 1389688; UTC 2688482, Pipe 2" - Cat ID 1145891; UTC 2716388 Flange 2" - Cat ID 1394827; UTC 2716420 Elbow 2" - Cat ID 1145933; UTC 2115600 CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this V\*!p\cxt.Aw*,-,4* conform to the rules of the ASME Code,Section XI. repair or replacement Type Code Symbol Stamp M,\A Certificate of Authorization No. .j itA Signed A;, ,\ 1 Owne(Jr Own*..*gnee, Title

  • ,v,
  • 1.',tk Date q-16-,20Ob' CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspeftors and the State of Province of Illinois and employed by Hartford Steam Boiler of _CT I have inspected the components described in this Owner's Report during the period 7 / 1/ to 4/16/2008 , and state that to the best of my knowledge and belief, the Owrerlhas performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the ex mi ations and corrective measures described in this Owner's Report.

Furtherm "either t, In ector nor his employer shall be liable in any manner for any personal injury or prope d m r ai, s of any kind arising from or conncted with this inspection.

____ v ___.-- _Commissions .L -Ail) )

Inspec(tr',s g ture , National Board, State, Province, and Endorsements Date 620