Pages that link to "ML20065P731"
Jump to navigation
Jump to search
The following pages link to ML20065P731:
Displayed 17 items.
- ML20079L297 (← links)
- ML20078L661 (← links)
- ML20071G333 (← links)
- ML20125B280 (← links)
- JAFP-93-0031, Special Rept 93-002:on 921228,fire Barrier,Installed in Front of Fire Door 76FDR-A-272-5,determined to Be Nonfunctional Based on Unsealed Opening in Barrier.Fire Watch Posted & Maint Work Request Initiated (← links)
- JAFP-93-0011, Updated Special Rept Documenting Inability to Restore Fire Door to Functional Status within Required Time Frame.On 921201,door Determined to Be Nonfunctional & Not Restored Until 921211.As of 930104,two Doors Remain Nonfunctional (← links)
- JAFP-93-0006, Special rept:post-work Testing & Repair of a Feedwater Return Valve 34NRV-111A Could Not Be Completed within 7-day Period.Continuous Fire Watch & Roving Fire Watch Posted & One Floor Plug Removed on 921219 & Replaced on 921221 (← links)
- JAFP-92-0854, Special Rept:On 921209,fire Barrier Doors Remain Nonfunctional Based Upon Revised Surveillance Test Acceptance Criteria.Revised Surveillance Test Criteria & Improved Maint Work Procedures Implemented (← links)
- JAFP-92-0782, Special Rept:On 921002,insp of Fire Doors,Using Revised Surveillance Test Procedure Initiated & Fire Barrier Doors Not Restored to Operable Status within 7 Days.As of 921109, 77 Doors Remained Nonfunctional.Fire Watch Posted (← links)
- JAFP-92-0570, Special Rept:On 920703,CO-2 Fire Door Required to Close on CO-2 Sys Activation Did Not Fully Close When Released.Fire Door Repaired & Tested Satisfactorily (← links)
- JAFP-92-0435, Special Rept:On 920504,CO2 Fire Suppression Sys Declared Inoperable When Walkdown Revealed That 4 Instead of 5 Nozzles Installed in Sys.Caused by Absence of Design Calculations.Replacement Nozzle Installed on 920518 (← links)
- JAFP-92-0454, Special Rept:On 911003,discovered pin-hole Leak in Diesel Fire Pump.Caused by Discharge Pressure.Surveillance Test Procedure Was Revised (← links)
- JAFP-92-0316, Special Rept:On 920406,electric Driven Pump Was Out of Service for Approx 16 Days & 5 H.Caused by Extended Overhaul Time.Electric Motor Was Removed,Overhauled,Tested,Found Satisfactory & Returned to Plant (← links)
- JAFP-91-0835, Special Rept:Relay Room CO2 Sys Declared Inoperable Due to Failed Surveillance Test.Caused by Slow Closure Time of Temp Control Damper 70MOD-103.Continuous Fire Watch Established & Design Basis Reconstitution Planned (← links)
- JAFP-95-0145, Special Rept 95-003:on 950223,TB HVAC Sys Fire/Carbon Dioxide Dampers Rendered non-functional in Support of Plant Mod M1-95-007.Dampers Not Returned to Functional Condition within Required Restoration Period Due to Duration of Mod (← links)
- JAFP-95-0082, Special Rept:On 950109,inoperability of Fire Suppression Features Associated W/Listed Areas Noted.Low Carbon Dioxide Concentration Deficiency Will Be Corrected by Changing Discharge Timer Setpoint (← links)
- JAFP-94-0252, Special Rept 94-001 Re Fire Barrier Penetration Seals Not Restored within TS Time Frame.Caused by Scope of Work in Steam Tunnel.Roving Fire Watch Posted in Recirculation Motor Generator Set Room & Floor Plugs Removed (← links)