Search by property

Jump to navigation Jump to search

This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.

Search by property

A list of all pages that have property "Title" with value "Potential Steam Voiding of Residual Heat Removal System". Since there have been only a few results, also nearby values are displayed.

Showing below up to 26 results starting with #1.

View (previous 50 | next 50) (20 | 50 | 100 | 250 | 500)


    

List of results

  • ML19330B281  + (Potential Significant Deficiency Rept Re Primary Containment Relief Valves Supplied by Gpe Controls.Bechtel Has Completed Review of Revised Stress Analysis Calculations.Expected Completion Date of Actions Is 800815)
  • ML20031F878  + (Potential Significant Deficiency Rept Re Seismic Design Analysis Review for Suppression Chamber,Initially Reported 810904.Licensee Currently Reviewing Deficiency.Completion Expected by 811106)
  • ML20100F620  + (Potential Significant Deficiency Rept SD-48 Re Main Control Board Lugs.Initially Reported on 831110.Seismic Testing & Repairs Completed.Final Test Rept Being Prepared.Next Rept Due by 850227)
  • ML20087C873  + (Potential Significant Deficiency Rept SD-51 Re Design & Const of Namco Model EA-180 Limit Switches Provided as Accessories on Valves Supplied by Pacific Valves.Initially Reported on 840131.Discussions W/Vendor Initiated)
  • ML20113B426  + (Potential Significant Deficiency Rept SD-75 Re Nonconforming Terminations in Equipment Supplied by CVI Corp.Initially Reported on 850213.S&W in Process of Developing Insp & Repair Program.Next Rept Will Be Submitted by 850612)
  • ML20132A348  + (Potential Significant Deficiency Rept SD-86 Re GE Type PVD21 Differential Relays Located in Class 1E 4160-volt Switchgear.Initially Reported on 850808.Relays Will Be Retested.Next Rept Will Be Submitted on 851018)
  • ML20113B584  + (Potential Significant Deficiency Rept SD-68 Re Parker Hannifin Corp Stainless Steel Fittings.Initially Reported on 850109.Investigation Incomplete.Next Rept Will Be Submitted by 850507)
  • ML20128Q015  + (Potential Significant Deficiency Rept SD-80 Re Weld Preparation on Skewed Fillet Weld Joints.Initially Reported on 850412.Insp of three- or four-sided Welds Completed.Welds Acceptable.Next Rept Will Be Submitted by 850710)
  • ML20128L157  + (Potential Significant Deficiency Rept SD-68 Re Matl Problems That Could Result in Cracks in Parker Hannifin Corp Stainless Steel Fittings.Initially Reported on 850109.Update Will Be Submitted by 850625)
  • ML20128R065  + (Potential Significant Deficiency Rept SD-79 Re Westinghouse 7300 Protection Sys.Initially Reported on 850408.S&W Redesigning Configuration.Next Rept Will Be Submitted by 850619)
  • ML20127L913  + (Potential Significant Deficiency Rept SD-78 Re Colt-Pielstick Emergency Diesel Generator Fuel Oil Injection Pump Failures.Initially Reported on 850401.Caused by Accumulation of Foreign Matter.Next Rept by 850613)
  • ML20113B370  + (Potential Significant Deficiency Rept SD-67 Re Improper Installation of Conduit Seal for Rosemount Pressure Transmitters.Initially Reported on 841214.Investigation Incomplete.Next Rept Will Be Submitted by 850501)
  • ML20128P178  + (Potential Significant Deficiency Rept SD-69 Re Westinghouse 7300 Process Control Cabinets.Initially Reported on 850111. Investigation Currently Being Performed.Next Rept Will Be Submitted by 850718)
  • ML20087N198  + (Potential Significant Deficiency Rept SD-50 Re phase-to- Phase Electric Fault in Motor Control Ctr Supplied by Gould,Inc.Initially Reported on 840116.All Uninsulated Cable Adapters Removed.Next Rept by 840620)
  • ML20135J058  + (Potential Significant Deficiency Rept SD-82 Re Deficient Westinghouse Core Exit Thermocouple Sys.Initially Reported on 850509.Qualification Tests on Sys Components Continuing. Next Rept Will Be Submitted on 850930)
  • ML20133H647  + (Potential Significant Deficiency Rept SD-85 Re Seismic Interaction of Flux Mapping Sys W/Seal & Table/Bottom Mounted Instrumentation.Initially Reported on 850726. Condition Under Investigation.Next Rept Expected by 850912)
  • ML20132D391  + (Potential Significant Deficiency Rept SD-80 Re Weld Preparation on Skewed Angle Fillet Weld Joints.Initially Reported on 850412.Two-sided Welds Being Reviewed on case-by-case Basis.Next Rept Will Be Submitted by 850822)
  • ML20128M409  + (Potential Significant Deficiency Rept SD-67 Re Rosemount Differential Pressure Transmitters W/Improper Conduit Installations.Initially Reported on 841214.Transmitters Will Be Reworked.Next Rept Expected by 850807)
  • ML20132A373  + (Potential Significant Deficiency Rept SD-81 Re Structural Steel Connections in Main Steam Valve Bldg.Initially Reported on 850510.Connections in Other QA Category 1 Bldgs Being Sampled.Next Rept Will Be Submitted by 850912)
  • ML20128P216  + (Potential Significant Deficiency Rept SD-81 Re Structural Steel Connections in Main Steam Valve Bldg (Msvb).Initially Reported on 850412.Insp of All Beam End Connections in Msvb Performed.Next Rept Will Be Submitted by 850711)
  • B10970, Potential Significant Deficiency Rept SD-46 Re Broken & Cracked Tangs on Capstan Springs Used on Pacific Scientific Size 1 & 3 Mechanical Snubbers.Initially Reported on 831018. All Affected Snubbers Will Be Returned to Vendor for Insp  + (Potential Significant Deficiency Rept SD-46 Re Broken & Cracked Tangs on Capstan Springs Used on Pacific Scientific Size 1 & 3 Mechanical Snubbers.Initially Reported on 831018. All Affected Snubbers Will Be Returned to Vendor for Insp)
  • ST-HL-AE-5003, Potential Slight Degradation of Decay Heat Removal Capacity Via Natural Circulation  + (Potential Slight Degradation of Decay Heat Removal Capacity Via Natural Circulation)
  • ML061010676  + (Potential Source Release and Transport Theories)
  • ML20024B909  + (Potential Sources of Nonprimary Sys Water in TMI-2 Reactor Bldg Sump)
  • ML14030A128  + (Potential Sser Corrections from TVA)
  • ML031360032  + (Potential Tech Spec Violation - Operation with Safety System Setting Less Conservative than Specified in Tech Specs)
  • 05000306/FIN-2011005-01  + (Potential Technical Specification NON-COMPLIANCE While Completing Repairs on Motor Damper 32421)
  • ENS 52896  + (Potential Technical Specification Violation)
  • 05000282/FIN-2009004-03  + (Potential Testing Emergency Response Organization Callout and Augmentation Process Performing Deficiency)
  • ENS 48675  + (Potential Theft of Pressure Indicator Containing Sr-90 Source)
  • ML19331C352  + (Potential Threat to Licensed Nuclear Activities from Insiders (Insider Study))
  • ML19344A706  + (Potential Threat to Licensed Nuclear Activities from Insiders (Insider Study))
  • ML19084A098  + (Potential Topics for Pre-Application Meetings for Peach Bottom SLRA)
  • ML19331A477  + (Potential Topics for SLR ISGs for November 26, 2019 Meeting)
  • ENS 52865  + (Potential Tornado Missile Vulnerabilities)
  • ENS 54437  + (Potential Tornado Missile Vulnerabilities)
  • ENS 53239  + (Potential Tornado Missile Vulnerabilities)
  • ENS 52571  + (Potential Tornado Missile Vulnerabilities)
  • 05000282/FIN-2009003-01  + (Potential Turbine Building Flooding Issue)
  • ENS 49128  + (Potential Unanalyzed Condition - Carbon Dioxide Fire Suppression System Does Not Meet Design Requirements)
  • 05000269/FIN-2014007-05  + (Potential Unanalyzed Condition Associated with Emergency Power System)
  • ENS 52242  + (Potential Unanalyzed Condition Based on Identified Non-Conforming Conditions)
  • ENS 46699  + (Potential Unanalyzed Condition Due to Power Level Greater than Limit)
  • ENS 47892  + (Potential Unanalyzed Condition with Containment Pressure Instruments)
  • ENS 43689  + (Potential Unavailability of Two Way Radio System to Support Safe Shutdown)
  • ML20101M552  + (Potential Uncertainty in Total Head Loss from Bwst to Mut Tie-In)
  • ENS 42343  + (Potential Uncontrolled Radiological Release)
  • 05000454/FIN-2012002-02  + (Potential Under-Torque of Valve 1RC8042B)
  • ENS 44321  + (Potential Underdose to Patient Undergoing Whole Body Radiation)
  • 05000395/FIN-2018010-06  + (Potential Unjustified Activation Energy for Barton Transmitters)