Finding | |
|---|---|
| Title | Potential Testing Emergency Response Organization Callout and Augmentation Process Performing Deficiency |
| Description | The inspectors identified an unresolved item (URI) concerning the licensee\\\'s process for testing its capability to callout the ERO to ensure timely augmentation of response capabilities is available. Specifically, during the review of the April 2007 through April 2009 off-hours, unannounced callout tests, the inspectors could not adequately verify that the test results supported the emergency plan commitment to have the capability for additional personnel within 30 and 60 minutes of notification. The inspectors reviewed a sampling of records for emergency organization augmentation response tests. The purpose of these tests was to determine the number of ERO personnel who would be available and the time required to respond to the plant. The inspectors noted for the successful tests, results indicated a number of 30-minute response personnel would take 30 minutes to arrive. Thirty minutes to arrive plus any delays in the callout process could challenge the 30-minute response time requirement. Prairie Island\\\'s approved emergency plan for ERO augmentation requires response times of 30 and 60 minutes from the time of notification. The guidance in NUREG 0654 states the licensee must be able to augment on-shift capabilities within a short period after declaration of an emergency. The licensee entered this issue into its corrective action program as CAP 01189478. Pending NRC staff\\\'s review if there is a performance deficiency, this issue was considered an Unresolved Item (URI 05000282/2009004-03; 05000306/2009004-03) |
| Site: | Prairie Island |
|---|---|
| Report | IR 05000282/2009004 Section 1EP3 |
| Date counted | Sep 30, 2009 (2009Q3) |
| Type: | URI: |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71114.03 |
| Inspectors (proximate) | C Zoia D Betancourt J Beavers J Giessner K Stoedter M Phalen N Feliz Adorno P Cardona Morales P Elkmann P Zurawski S Shah V Meghanic Moorec Thomas D Betancourt D Mcneil F Tran J Giessner K Stoedter M Holmberg M Thorpe Kavanaugh N Valos P Zurawski R Jickling |
| INPO aspect | |
| ' | |