Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20011A640 +
- ML20011A443 +
- ML18139B561 +
- ML20038B313 +
- ML17341A689 +
- ML20042A679 +
- ML20040G063 +
- ML20040C278 +
- 05000237/LER-1981-059, Forwards LER 81-059/03L-0 +
- ML20062M358 +
- ML20213D858 +
- ML20263R499 +
- ML20263R498 +
- ML20263R494 +
- ML20263A644 +
- ML20262E594 +
- ML20054G609 +
- ML20263D213 +
- ML20259E820 +
- ML20259A690 +
- 05000237/LER-1981-059-03, /03L-0:on 810910,while Conducting Insp on Pump 2A,CCSW Outboard Bearing Found Burned Out.Caused by Lack of Lubrication in Sealed Bearing.Bearing Replaced +
- ML20054C946 +
- IR 05000309/1981020 +
- ML20041D629 +
- IR 05000259/1981019 +
- ML20042B349 +
- IR 05000373/1981033 +
- 0CAN108104, Application for Amend to Licenses DPR-51 & NPF-6,proposing Tech Specs Changes for Reorganization of Health Physics Section to Improve Coordination of Overall Radiation Protection Program +
- 05000267/LER-1981-057, Forwards LER 81-057/03L-0.Detailed Event Analysis Encl +
- 05000267/LER-1981-057-03, /03L-0:on 810908,engine of Diesel Generator Unit Found Inoperable.Caused by Failed Clutch Bearing.Clutch Bearing & Shaft Replaced & Generator Returned to Svc +
- 05000334/LER-1981-086, Forwards LER 81-086/03L-0 +
- 05000334/LER-1981-086-03, /03L-0:on 810910,electrical Arcing Observed Inside Battery Charger Compartment 4 During Test.Caused by Bad Electrical Wiring Connection within Charger.High Resistance Across Point Caused Arcing When Charger Increased +
- 05000334/LER-1981-085-04, /04L-0:on 810909,during Maint Surveillance Test, Cooling Tower Discharge Temp High Alarm Found Inoperable. Caused by Faulty Alarm Relay Switch at Recorder.Relay Replaced +
- 05000334/LER-1981-085, Forwards LER 81-085/04L-0 +
- ML20031G845 +
- 0CAN108105, Requests Registration as User of Model CNS-120 +
- 05000333/LER-1981-070, Forwards LER 81-070/04T-0 +
- 05000333/LER-1981-070-04, /04T-0:on 810925,environ Radiological Sampling Resulted in Anomalous Results for Periphyton Samples. Calculated Dose to Man Will Be Included in 1981 Radiological Environ Surveillance Rept +
- ML20031G531 +
- ML20031H190 +
- 05000293/LER-1981-049, Updated LER 81-049/01T-1:on 810828,discovered Water Bypass Condition in B RBCCW Heat Exchanger Will Be Installed.Caused by Water Erosion Due to Mussel Blockage Induced High Delta P.Design Change Repass Partition Plates +
- 05000366/LER-1981-091, Forwards LER 81-091/03L-0 +
- 05000366/LER-1981-091-03, /03L-0:on 810917,during steady-state Operation at 1942 Mw,Torus Vacuum Relief valve,2T48-F310,was Found Open. Caused by Component Failure.New Switch Installed.Design Change Initiated to Install Compatible Design Switches +
- 05000324/LER-1981-098, Forwards LER 81-098/03L-0 +
- 1CAN108105, Forwards Change to Proposed Tech Specs Re Degraded Grid Voltage Per Conversation W/G Vissing & 810220 Amend Request. Change Reflects Exemption to Spec 3.0.4 to Allow start-up If Degraded Voltage Automatic Sys Is Inoperable +
- 05000324/LER-1981-098-03, /03L-0:on 810914,during Core Spray Sparger High D/P Calibr & Functional Test,Switch 1 of a Core Spray D/P Instrument 2-E21-dPIS-NOO4A,model 288,would Not Actuate. Caused by Sticking Actuator Arm.Actuator Arm Cleaned +
- 05000321/LER-1981-104, Forwards LER 81-104/03L-0 +
- 05000282/LER-1981-012-03, /03L-0:on 810909,during Surveillance Test,One Low Pressurizer Pressure Reactor Trip Bistable Failed to Trip. Caused by Failure of Foxboro Model 63U-AC-OBHA-F Single Low Alarm Unit.Unit Replaced +
- 05000321/LER-1981-104-03, /03L-0:on 810923,while Performing HNP-1-5100 Logarithmic Radiation Monitor,Main Steam Line Radiation Monitor Was Not Working Properly.Caused by Defective Integrated Circuit in Trip Logic.Circuit Replaced +
- 05000282/LER-1981-012, Forwards LER 81-012/03L-0 +