- TAC:79166 +
- LIC-91-0011, Special Rept:On 910211,both Barrier Penetrations 19-E-39 Between Room 19 & Turbine Bldg & Concrete Block Wall at East End of Corridor 4 Breached to Support Long Term Maint on HX AC-1A.Appropriate Compensatory Measures in Place +
- BECO-91-040, Forwards Summary of Compliance W/Reg Guide 1.97,Rev 2 to Assist NRC in Review of Compliance W/Reg Guide 1.97,Rev 3, Per 9100115 & 0405 Ltrs +
- ML20206Q670 +
- 05000327/LER-1991-003, :on 910218,centrifugal Charging Pump Declared Inoperable & Removed from Svc Due to Pump Degradation.Caused by Heavy Wear on Impeller Shoulders in Wear Ring Area.Pump Rotating Element Replaced +
- 05000413/LER-1991-008, :on 910219,determined That Control Room Ventilation Sys Could Not Satisfy GDC 19 Requirements Under Postulated Scenario.Caused by Design Deficiency.Intake Valves Deenergized to Remain Open +
- 05000498/LER-1991-005, :on 910218,opening of Fuel Handling Bldg Truck Doors During Fuel Movement Causes Tech Spec Violation.Caused by Incomplete Adminstrative Controls on Fuel Handling Bldg Door.Locks Placed on Truck Doors +
- 05000461/LER-1991-002, :on 910218,loss of Svc & Instrument Air Occurred Resulting in Manual Scram Insertion.Caused by Personnel Error.Surge Suppression Switch on Compressor Recalibrated +
- 05000461/LER-1991-003, :on 910220,jarring of Division III Diesel Generator Breaker Cubicle Door by Utility Maint Personnel Results in Automatic Start of Diesel Generator.Caused by Personnel Error.Preventive Maint Developed +
- PNO-I-91-019A, on 910312-15,augmented Insp Team Preliminary Findings Re Loss of Emergency Power Capability Based on Events Leading Up to Failure of EDG Discussed.Special Rept Will Be Issued on 910412 +
- ML20029C482 +
- 05000301/LER-1990-002, :on 901009,inadvertent Start of Auxiliary Feedwater Pump Occurred.Caused by Inadequate Test Procedures.Auxiliary Feedwater Pump Secured & Maint Work Request Mwr 904517 Initiated +
- ML20029C478 +
- BECO-91-039, Responds to 910131 Telcon Request for Addl Info on Dcrdr Human Engineering Deficiency 4B217 Re GE SBM-type Two Position Control Switches Found on Control Panels C7 & C904, Per NUREG-0737,Item I.D.1 +
- IR 05000440/1991003 +