Proposed Tech Specs to Permit Use of Continuous Pressure Testing of Containment Airlock Door Seal Gaskets in Lieu of Manual Testing
ML20070P396
Person / Time
Site: Byron, Braidwood  
Issue date: 03/20/1991
From:
COMMONWEALTH EDISON CO.
To:
Shared Package
ML20070P374 List:
References
NUDOCS 9103270278
Download: ML20070P396 (1)


Text

_

95 CONTAINMENT SYSTEMS SURVEILLANCE _ REQUIREMENTS 4.6.1.3 Each containment air lock shall be demonstrated OPERABLE:

a.

Within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> following each closing, except when the air lock is being used for multiple entries, then at least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, by

-the-door-seals-45-pressurized-to greatertRan or the-volume-betwun ve ri fyi ng -sul-l ea kage-i s-l e s s -tha n-O r 01-L-when-equal-to-10-psigr-

-for-at-lust-16-minutu,

b.

By conducting overall air lock leakage tests at not less than P,,

44.4 psig, and verifying the overall air lock leakage rats is within its limit:

1)

At least once per 6 months,* and 2)

Prior to esLablishing CONTAINMENT INTEGRITY when maintenancs.

has been performed on the air lock that could affect the air lock sealing capability **

c.

At least once per 6 months by verifying that only one door in each 1

air lock can be opened at a time.

d. M f{o (6 Jib a

W that the seal leakage is less than 0.01La (4.63 S;M as j

detern.ined by precision flow neasurements when measured for at least 30 seconds with the volume between the seals at a constant pressure of greater than or equal to 10 psigt i

.-~

/

j u Verifying that the seal leakage is less than 0.002(La (1.11 S0nO when the

[

volume between the door seals is pressurized to greater than or equal to 3 psig by means of a peta.anently installed continuous pressurization and leakage monitoring system, or kt*

) Verifying that thefseal leakage is less than 0.01La (4.63 FrH) as deternined by precision flow measureunenu when measured for at least 30 seconds with the volume between the seals at a constant pressure of greater than or equal to 10 psig;
  • The prbisions of Specification 4.0.2 are not applicable.

A

    • This represents an exemption to Appendix J of 10 CFR Part 50, Paragraph III U

D.2(b)(ii).

9103270278 910320 PDR ADOCK 05000454 P

PDR BRAIDWOOD - UNITS 1 & 2 3/4 6-5