Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- IR 05000259/1979037 + (09:17:03, 7 January 2025)
- ML18024B432 + (09:17:08, 7 January 2025)
- ML18024B431 + (09:17:09, 7 January 2025)
- ML18024B430 + (09:17:11, 7 January 2025)
- ML18024B429 + (09:17:11, 7 January 2025)
- ML18024B425 + (09:17:12, 7 January 2025)
- IR 05000259/1980001 + (09:17:17, 7 January 2025)
- ML18024B408 + (09:17:18, 7 January 2025)
- IR 05000259/1979039 + (09:17:19, 7 January 2025)
- ML18024B405 + (09:17:21, 7 January 2025)
- 05000296/LER-1980-006-03, /03L-0:on 800217,w/unit at Steady State Operation, Emergency Equipment Cooling Water Flow Did Not Meet Min Flow of 4 Gpm.Caused by Shells & Mud Preventing Adequate Flow Through Residual Heat Removal Pump 3B Seal Cooler Valve + (09:17:23, 7 January 2025)
- 05000296/LER-1980-006, Forwards LER 80-006/03L-0 + (09:17:25, 7 January 2025)
- ML18024B400 + (09:17:26, 7 January 2025)
- 05000260/LER-1980-008-31, /03L-0:on 800206,while Conducting Automatic Depressurization Sys Logic Functional Test,Relay 10A-K26 Manually Operated in Place of Relay 2E-K26 Causing Recirculation Pump 2B Trip.Caused by Operator Error + (09:17:28, 7 January 2025)
- 05000296/LER-1980-005-03, /03L-0:on 800205,during Normal Operation,Fcv 74-73 Found Inoperable While Performing Surveillance Instruction. Caused by Random Failure of Gear Tooth in Limit Switch,Size SMB-2,Model 3-G.Limit Switch Replaced + (09:17:30, 7 January 2025)
- 05000296/LER-1980-005, Forwards LER 80-005/03L-0 + (09:17:32, 7 January 2025)
- 05000260/LER-1980-008, Forwards LER 80-008/03L-0 + (09:17:34, 7 January 2025)
- 05000260/LER-1980-006-03, /03L-0:on 800203,while Running Electrical Checks on Recirculation Pump,Reactor Recirculation Pump 2A Was Accidentally Tripped.Caused by Misinterpretation of Labels on Recirculation Pump Trip Breakers + (09:17:36, 7 January 2025)
- 05000260/LER-1980-006, Forwards LER 80-006/03L-0 + (09:17:38, 7 January 2025)
- 05000260/LER-1980-007-03, /03L-0:on 800203,during Normal Operation,Reactor Recirculation Pump 2B Tripped.Caused by Pickup of Recirculation Motor Generator Set Generator Stator Temp Relay.Tests Run,No Problems Found + (09:17:40, 7 January 2025)
- 05000260/LER-1980-007, Forwards LER 80-007/03L-0 + (09:17:48, 7 January 2025)
- IR 05000259/1979034 + (09:17:50, 7 January 2025)
- ML18024B385 + (09:17:52, 7 January 2025)
- ML18024B384 + (09:17:53, 7 January 2025)
- ML18024B383 + (09:17:54, 7 January 2025)
- ML18024B381 + (09:17:55, 7 January 2025)
- IR 05000259/1979046 + (09:17:56, 7 January 2025)
- ML18024B378 + (09:17:57, 7 January 2025)
- 05000296/LER-1980-004-03, /03L-0:on 800129,4160 Volt Bus Tie Board de-energized & Restored to Normal Cooling Tower Transformer Feeder.Caused by Need to Return Electrical Sys to Normal Configuration.No Recurrence Control Required + (09:17:59, 7 January 2025)
- 05000296/LER-1980-004, Forwards LER 80-004/03L-0 + (09:18:01, 7 January 2025)
- ML18024B373 + (09:18:02, 7 January 2025)
- ML18024B370 + (09:18:03, 7 January 2025)
- ML18024B368 + (09:18:04, 7 January 2025)
- ML18024B367 + (09:18:05, 7 January 2025)
- 05000260/LER-1980-003-03, /03L-0:on 800122,during Normal Operation,Momentary Breach of Secondary Containment Occurred When Air Lock Doors Between Turbine & Reactor Bldg Were Simultaneously Opened.Caused by Misaligned Latch Lock & Latch Bolt + (09:18:07, 7 January 2025)
- ML18024B364 + (09:18:08, 7 January 2025)
- 05000260/LER-1980-005-03, /03L-0:on 800125,while Performing Special Instruction 4.2.B-1 During Normal Operation,Switches 1,2 & 4 on LIS-3-58A Did Not Operate at Proper Setpoint.Caused by Switch 4 Hanging on Magnet.Switches Adjusted + (09:18:09, 7 January 2025)
- 05000260/LER-1980-005, Forwards LER 80-005/03L-0 + (09:18:11, 7 January 2025)
- ML18024B360 + (09:18:13, 7 January 2025)
- 05000260/LER-1980-004-03, /03L-0:on 800122,reactor Water Level Switch LIS-3- 203D Switch 2 Exceeded Tech Spec Limit During Normal Operation.Caused by Model 288A Switch Drifting Above Setpoint.Switch Tested,Inspected & Recalibr + (09:18:14, 7 January 2025)
- 05000260/LER-1980-004, Forwards LER 80-004/03L-0 + (09:18:19, 7 January 2025)
- 05000296/LER-1980-003-03, /03L-0:on 800126,while Performing Control Rod Exercise,Control Rod 18-55 Would Not Insert W/Normal Drive Pressure.Caused by Failed Seal in Hydraulic Control Unit Directional Control Valve.Valve Repaired + (09:18:21, 7 January 2025)
- 05000296/LER-1980-003, Forwards LER 80-003/03L-0 + (09:18:23, 7 January 2025)
- ML18024B353 + (09:18:24, 7 January 2025)
- ML18024B350 + (09:18:26, 7 January 2025)
- ML18024B352 + (09:18:26, 7 January 2025)
- ML18024B349 + (09:18:27, 7 January 2025)
- ML18024B343 + (09:18:28, 7 January 2025)
- ML18024B345 + (09:18:28, 7 January 2025)
- 05000296/LER-1980-002-03, /03L-0:on 800117,while Performing Surveillance Instruction 4.5.B.1.d,residual Heat Removal Sys Flow Control Valve FCV.74-73 Tripped in mid-position.Caused by Valve Stem Lubricant Losing Lubricity,Causing Force on Motor + (09:18:30, 7 January 2025)
- 05000296/LER-1980-002, Forwards LER 80-002/03L-0 + (09:18:32, 7 January 2025)