APPENDIX A NOTICE OF VIOLATION Tennessee Valley Authority License No. DPR-33 Based on the NRC inspection September 17 - October 12, 1979, certain of your acti-vities were apparently not conducted in full compliance with NRC requirements as indicated below.

These items have been categorized as described in correspondence to you dated December 31, 1974.

As required by Technical Specification 6.3.A, detailed written procedures shall be prepared, approved and adhered to for safety related maintenance activities.

Browns Ferry Standard Practice 8.2, Temporary Alterations, requires temporary alterations, including jumpers and inhibits, to be reviewed by the Plant Operations Review Committee (PORC) prior to instal-lation.

Contrary to the above, on September 26,

1979, jumpers and inhibits were placed on the main steam line tunnel high-temperature monitoring channels A

and D without prior PORC review.

This is an infraction.