Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19256E496 + (05:51:44, 4 January 2025)
- 05000309/LER-1979-024-99, /99X-0:on 791017,reactor Coolant Dose Equivalent Iodine Exceeded Tech Spec Limits of 1.0 Uci/G.Caused by Unscheduled Plant Trip.Monitoring Program Established Following Trip to Adhere to Iodine Trends + (05:51:47, 4 January 2025)
- ML19256E494 + (05:51:49, 4 January 2025)
- 05000336/LER-1979-032-03, /03L-0:on 791002,during Repairs to Metrascope, Control Element Assemblies 6 & 7 in Shutdown Group B Indicated Low Readings.Caused by Faulty Input Amplifiers. Metrascope re-energized + (05:52:19, 4 January 2025)
- ML19256E491 + (05:52:24, 4 January 2025)
- 05000309/LER-1979-024, Forwards LER 79-024/99X-0 + (05:52:26, 4 January 2025)
- 05000336/LER-1979-032, Forwards LER 79-032/03L-0 + (05:53:09, 4 January 2025)
- 05000324/LER-1979-085-03, /03L-0:on 790918,suppression Pool Water Temp Recorder on Remote Shutdown Panel Discovered Inoperable. Relay K-3 Dirty & Not Making Good Contact.Contacts Burnished & Recorder Returned to Svc + (05:53:53, 4 January 2025)
- 05000302/LER-1979-096, Forwards LER 79-096/01T-0 + (05:54:18, 4 January 2025)
- 05000338/LER-1979-122-31, /03L-0:on 790919,during Normal Operation,Steam Generator C Support Temp Fell Below Tech Specs Limit of 225 F.Caused by Personnel Failure to Recognize Low Support Temp Until Temp Exceeded.Support Heaters Energized + (05:54:57, 4 January 2025)
- 05000324/LER-1979-085, Forwards LER 79-085/03L-0 + (05:55:43, 4 January 2025)
- 05000295/LER-1979-077-01, /01T-0:on 791016,cracks Identified in Steam Generator Feedwater Nozzles & Associated Piping.Will Remove One Nozzle for Examination.Updated LER to Be Submitted 30 Days Following Test + (05:55:53, 4 January 2025)
- ML19256E476 + (05:55:55, 4 January 2025)
- 05000295/LER-1979-077, Forwards LER 79-077/01T-0 + (05:55:57, 4 January 2025)
- 05000317/LER-1979-055-03, /03L-0:on 790930,channel a Lower Positive Power Distribution Setpoint Found Decreasing.Caused by end-of-life Type Failure of Adjustment Potentiometer of Dual Potentiometer/Buffer Module Model 384612-01 + (05:56:33, 4 January 2025)
- 05000317/LER-1979-055, Forwards LER 79-055/03L-0 + (05:56:58, 4 January 2025)
- ML19256E470 + (05:57:01, 4 January 2025)
- ML19256E469 + (05:57:02, 4 January 2025)
- ML19256E468 + (05:57:04, 4 January 2025)
- ML19256E467 + (05:57:05, 4 January 2025)
- ML19256E466 + (05:57:07, 4 January 2025)
- ML19256E465 + (05:57:14, 4 January 2025)
- ML19256E464 + (05:57:16, 4 January 2025)
- ML19256E463 + (05:57:17, 4 January 2025)
- ML19256E462 + (05:57:18, 4 January 2025)
- ML19256E461 + (05:57:20, 4 January 2025)
- ML19256E460 + (05:57:22, 4 January 2025)
- ML19256E459 + (05:57:23, 4 January 2025)
- ML19256E458 + (05:57:24, 4 January 2025)
- ML19256E455 + (05:57:25, 4 January 2025)
- ML19256E454 + (05:57:26, 4 January 2025)
- ML19256E453 + (05:57:27, 4 January 2025)
- ML19256E452 + (05:57:29, 4 January 2025)
- ML19256E451 + (05:57:31, 4 January 2025)
- ML19256E450 + (05:57:33, 4 January 2025)
- ML19256E449 + (05:57:34, 4 January 2025)
- ML19256E448 + (05:57:36, 4 January 2025)
- ML19256E447 + (05:57:37, 4 January 2025)
- ML19256E446 + (05:57:39, 4 January 2025)
- ML19256E445 + (05:57:40, 4 January 2025)
- ML19256E444 + (05:57:54, 4 January 2025)
- ML19256E443 + (05:57:56, 4 January 2025)
- ML19256E442 + (05:57:59, 4 January 2025)
- ML19256E439 + (05:58:02, 4 January 2025)
- ML19256E438 + (05:58:05, 4 January 2025)
- ML19256E435 + (05:58:05, 4 January 2025)
- ML19256E434 + (05:58:07, 4 January 2025)
- IR 05000369/1979030 + (05:58:09, 4 January 2025)
- ML19256E432 + (05:58:11, 4 January 2025)
- ML19256E431 + (05:58:14, 4 January 2025)
- ML19256E430 + (05:58:15, 4 January 2025)