7KL

/

'o UNITED STATES NUCLEAR REGULATORY COMMISSION n

E REGION 11 o

  • o 101 MARIETTA ST., N.W., SUITE t.00 h

e

ATLANTA, GEORGIA 30303 OCT 17 BD In Reply Refer To:

RI_I:JP0 Q 302 ;

Florida Power Corporation Attn:

W. P. Stewart, Manager Nuclear Operations P. O. Box 14042, Mail Stop C-4 St. Petersburg, Florida 33733 Gentlemen:

Enclosed is IE Bulletin No. 79-13, Revision 2 which requires action by you with regard to your power reactor f acility(ies).

Should you have any questions regarding this Bulletin or the actions required by you, please contact this office.

Sincerely, O

w mes P. O'Reilly D ector

Enclosures:

/

1.

IE Bulletin No. 79-13, Revision 2 w/ Attachments 2.

List of IE Bulletins Issued in Last Six Months

' " 2 354

>L 7911070 L

i

OCT 171979 Florida Power Corporation.

cc w/ enc 1:

G. P. Beatty, Jr.

Nuclear Plant Superintendent Post Office Box 1240 Crystal River, Florida 32629 1'"'2 355

e SSINS:

6830 Accession No.:

7908220135 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 October 16, 1979 IE Bulletin No. 79-13 Revision 2 CRACKING IN FEEDWATER SYSTEM PIPING Description of Circumstances:

This revision to IE Bulletin No. 79-13 is based on the results of the radio-graphic examinations and ongoing investigation of the subject problem to date since the initial Bulletin was issued. The revision reduces in scope the R2 number and extent of the piping system welds required to be examined. The rec,uirements for reporting and action time frame remain unchanged.

Jn May 20, 1979, Indiana and Michigan Power Company notified the NRC of cracking in two feedwater lines at their D. C. Cook Unit 2 facility. The cracking was discovered following a shutdown on May 19 to investigate leakage inside containment. Leaking circumferential cracks were identified in the 16-inch feedwater elbows adjacent to two steam generator nozzle elbow welds.

Subsequent radiographic examination revealed crack indications in all eight steam generator feedwater lines at this location on both Units 1 and 2.

On May 25, 1979, a letter was sent to all PWR licensees by the Office of Nuclear Reactor Regulation which informed licensees of the D. C. Cook failures and requested specific information on feedwater system design, fabrication, inspection and operating histories. To further explore the generic nature of the cracking problem, the Office of Inspeccion and Enforcement requested licensees of PWR plants in current outages to immediately conduct volumetric examination of certain feedwater piping welds.

As a result of these actions, several other licensees with Westinghouse steam generators reported crack indications. Southern California Edison reported on June 5,1979, that radiographic examination revealed indications of cracking in feedwater nozzle-to pipe welds on two of three steam generators of San Onofre Unit 1.

On June 15, 1979, Carolina Power and Light reported that radiography shosed crack indications in similar locations at their H. B.

Robinson Unit 2.

Duquesne Power and Li radiography has shown cracking in their to-vessel nozzle weld. Public Service June 20, 1979 that Salem Unit I also ha M DUPLICATE DOCUMENT Service company decided on June 20,197 weld which contained questionable indic Entire dccmnent previcAlsly As of June 22, 1979 and since May 25, 1 entered into system under:

inspected the feedwater nozzle-to pipe ANO bb 19n2 356 c,e gags.

jy sc,.

o NOTE:

R1 and R2 indicates lines revi