- ML20212P711 + (09:19:19, 4 December 2024)
- ML20212P708 + (09:19:22, 4 December 2024)
- ML20212P706 + (09:19:26, 4 December 2024)
- 05000255/LER-1987-005, :on 860216,lifted Relief Valve on Steam Generator Secondary Manway Identified,Constituting Failed Containment Penetration.Caused by Failure of Inner Manway Gasket & Improper Valve Installation + (09:19:30, 4 December 2024)
- ML20212P699 + (09:19:32, 4 December 2024)
- ML20212P695 + (09:20:09, 4 December 2024)
- 05000237/LER-1987-003, :on 870108,primary Containment Drywell Structural Steel Did Not Meet FSAR Design Requirements Due to Inadequate Connections Between Radial & Tangential Beams. Caused by Inadequate Confirmation of Const + (09:20:14, 4 December 2024)
- ML20212P690 + (09:20:15, 4 December 2024)
- ML20212P689 + (09:20:17, 4 December 2024)
- ML20212P687 + (09:20:19, 4 December 2024)
- DCL-87-045, Responds to Violations Noted in Insp Rept 50-275/87-06 Dtd 870210.Corrective Actions:Investigation Begun,Including Review of Actions Taken & Documentation & Discussions W/Util Personnel,State & County.Emergency Procedure G-3 Revised + (09:20:21, 4 December 2024)
- ML20212P685 + (09:20:24, 4 December 2024)
- ML20212P684 + (09:20:25, 4 December 2024)
- ML20212P683 + (09:20:27, 4 December 2024)
- ML20212P682 + (09:20:29, 4 December 2024)
- ML20212P680 + (09:20:31, 4 December 2024)
- ML20212P679 + (09:20:32, 4 December 2024)
- TXX-4966, Final Deficiency Rept CP-86-34 Re Fire Stop Installations Exceeding Design Temp of Unexposed Surface During ASTM E-119 Fire Test.Initially Reported on 860501.Issue Not Reportable Under 10CFR50.55(e) + (09:20:33, 4 December 2024)
- ML20212P676 + (09:20:37, 4 December 2024)
- B12450, Application to Amend License DPR-61,revising Tech Spec 4.12 Re High Energy Piping Sys by Expanding Augmented Inservice Insp Program to Include Break Locations on Steam Supply Lines to Auxiliary Feedwater Pumps + (09:20:38, 4 December 2024)
- ML20212P673 + (09:20:40, 4 December 2024)
- ML20212P672 + (09:20:43, 4 December 2024)
- 05000482/LER-1987-008, :on 870208,control Room Ventilation Isolation Signal Initiated.Caused by Spurious Spike on Control Room Air Intake Chlorine Monitor Gk AITS-3.No Root Cause Identified.Design Change Being Considered + (09:20:48, 4 December 2024)
- ML20212P666 + (09:20:53, 4 December 2024)
- ML20212P663 + (09:20:57, 4 December 2024)
- ML20212P661 + (09:20:59, 4 December 2024)
- ML20212P658 + (09:21:03, 4 December 2024)
- TXX-4982, Interim Deficiency Rept CP-86-53 Re Seismic Design of Conduit.Initially Reported on 860725.Program to Test Ability of Adhesives to Resist Torsional Moments Under Evaluation. Next Rept Will Be Submitted by 861021 + (09:21:08, 4 December 2024)
- ML20212P654 + (09:22:48, 4 December 2024)
- ML20212P652 + (09:22:51, 4 December 2024)
- IR 05000282/1987002 + (09:22:54, 4 December 2024)
- 05000305/LER-1986-010, :on 860801,ESF Actuation Occurred Due to Electrical Jumper Shorting to Ground.Caused by Low Profile Design of Connecting Screws on Terminal Strip.Banana Jacks Added Where Jumpers Used + (09:23:00, 4 December 2024)
- 05000219/LER-1987-007, :on 861231,processed Water Released to Environ W/Radwaste Liquid Monitors Inoperable & on 870130,discovered That Tech Spec Limiting Conditions for Discharging Overboard Not Satisfied.Caused by Technician Error + (09:24:03, 4 December 2024)
- ML20212P646 + (09:24:04, 4 December 2024)
- ML20212P644 + (09:24:06, 4 December 2024)
- ML20212P643 + (09:24:07, 4 December 2024)
- ML20212P640 + (09:24:11, 4 December 2024)
- ML20212P639 + (09:24:13, 4 December 2024)
- JPN-87-007, Proposed Tech Spec Changes Allowing Use of Both 12-inch & 6- Inch Lines to Standby Gas Treatment Sys for Inerting & Deinerting Primary Containment + (09:24:14, 4 December 2024)
- ML20212P636 + (09:24:16, 4 December 2024)
- ML20212P633 + (09:24:19, 4 December 2024)
- ML20212P630 + (09:24:20, 4 December 2024)
- ML20212P627 + (09:24:21, 4 December 2024)
- ML20212P626 + (09:24:22, 4 December 2024)
- ML20212P623 + (09:24:23, 4 December 2024)
- ML20212P622 + (09:24:25, 4 December 2024)
- ML20212P620 + (09:24:26, 4 December 2024)
- ML20212P617 + (09:24:28, 4 December 2024)
- ML20212P615 + (09:24:31, 4 December 2024)
- ML20212P612 + (09:24:33, 4 December 2024)
- ML20212P611 + (09:24:35, 4 December 2024)