- ML20216C865 + (01:47:03, 4 December 2024)
- ML20216C864 + (01:47:04, 4 December 2024)
- ML20216C863 + (01:47:04, 4 December 2024)
- ST-HL-AE-5732, Forwards Unit 1 Cycle 7 Incomplete Rcca Insertion Evaluation Criteria for Aug/Sept 1997 Rod Drop Testing + (01:47:08, 4 December 2024)
- ML20216C860 + (01:47:09, 4 December 2024)
- 05000455/LER-1998-002-03, :on 980312,channel 3 of Overtemperature Delta Temp (OTDT) Was Inoperable.Caused by Failure of 7300 Protection Sys lead-card in OTDT Channel 4.Failed Card Replaced + (01:47:11, 4 December 2024)
- B17164, Responds to 980313 RAI Re Proposed Revision 19 to Northeast Utilities Quality Assurance Program Topical Rept + (01:47:12, 4 December 2024)
- ML20216C854 + (01:47:13, 4 December 2024)
- ML20216C852 + (01:47:13, 4 December 2024)
- ML20216C850 + (01:47:14, 4 December 2024)
- TXX-6545, Advises That Util Evaluating Alternate Resolution Re Potential Zinc Embrittlement of Stainless Steel Tubing & walk-down Activities Suspended Pending Completion of Evaluation,Per 870414 Response to Notice of Violation + (01:47:15, 4 December 2024)
- ML20216C848 + (01:47:16, 4 December 2024)
- ML20216C846 + (01:47:16, 4 December 2024)
- ML20216C845 + (01:47:17, 4 December 2024)
- IR 05000254/1997015 + (01:47:19, 4 December 2024)
- ML20216C839 + (01:47:20, 4 December 2024)
- ML20216C837 + (01:47:21, 4 December 2024)
- ML20216C836 + (01:47:21, 4 December 2024)
- ML20216C834 + (01:47:22, 4 December 2024)
- ML20216C835 + (01:47:22, 4 December 2024)
- ML20216C831 + (01:47:23, 4 December 2024)
- ML20216C832 + (01:47:23, 4 December 2024)
- ML20216C829 + (01:47:24, 4 December 2024)
- ML20216C828 + (01:47:25, 4 December 2024)
- ML20216C824 + (01:47:25, 4 December 2024)
- ML20216C823 + (01:47:26, 4 December 2024)
- ML20216C818 + (01:47:27, 4 December 2024)
- ML20216C819 + (01:47:27, 4 December 2024)
- ML20216C815 + (01:47:28, 4 December 2024)
- ML20216C813 + (01:47:29, 4 December 2024)
- ML20216C810 + (01:48:32, 4 December 2024)
- 05000461/LER-1998-008-01, :on 930213,Division I Hydrogen & Oxygen Analyzer Incapable of Meeting Design Basis Were Noted Due to an Excessive Vibration Condition on Air Compressor.Caused by Personnel Error.Div 1 H202 Air Condition Will Be Corrected + (01:48:35, 4 December 2024)
- ML20216C805 + (01:48:35, 4 December 2024)
- ML20216C802 + (01:48:37, 4 December 2024)
- IR 05000416/1997017 + (01:48:38, 4 December 2024)
- ML20216C800 + (01:48:39, 4 December 2024)
- ML20216C798 + (01:48:41, 4 December 2024)
- ML20216C797 + (01:48:41, 4 December 2024)
- ML20216C794 + (01:48:42, 4 December 2024)
- ML20216C793 + (01:48:43, 4 December 2024)
- ML20216C786 + (01:48:46, 4 December 2024)
- ML20216C782 + (01:48:47, 4 December 2024)
- ML20216C785 + (01:48:47, 4 December 2024)
- ML20216C781 + (01:48:48, 4 December 2024)
- ML20216C780 + (01:48:48, 4 December 2024)
- TXX-6543, Interim Deficiency Rept CP-86-37 Re Firing Board Assemblies & Amplifier Boards Used in Class 1E Battery Chargers That Do Not Conform to Vendor Assembly Drawings.Initially Reported on 860514.Next Rept Will Be Submitted by 870724 + (01:48:49, 4 December 2024)
- ML20216C777 + (01:48:50, 4 December 2024)
- 05000461/LER-1998-008, Forwards LER 98-008-00,re Division I Hydrogen & Oxygen Analyzer Incapable of Meeting Design Basis Due to an Excessive Vibration Condition on Air Compressor.Caused by Personnel Error.Commitments Made within Ltr,Listed + (01:48:50, 4 December 2024)
- ML20216C769 + (01:48:51, 4 December 2024)
- ML20216C768 + (01:48:52, 4 December 2024)
- ML20216C767 + (01:48:52, 4 December 2024)