ML20216C854
| ML20216C854 | |
| Person / Time | |
|---|---|
| Site: | Wolf Creek |
| Issue date: | 09/04/1997 |
| From: | Howell A NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | Maynard O WOLF CREEK NUCLEAR OPERATING CORP. |
| Shared Package | |
| ML20216C858 | List: |
| References | |
| 50-482-97-12, NUDOCS 9709090152 | |
| Download: ML20216C854 (5) | |
See also: IR 05000482/1997012
Text
- __ - _ _ - _ - - -- - -
.
/g*"%<,it
O
UNITED ST ATES
NUCLEAR REGULATORY COMMISSION
.
$
REGloN IV
%f
4
611 RYAN PLAZA oRIVE, SulTE 400
%,, ..."#
/
AR LINO ton, T E X AS 76011 8064
N
.+
!
September 4,1997
Otto L Maynard, President and
Chief Executive Officer
Wolf Creek Nuclear Operating Corporation
P.O. Box 411
Burlington, Kansas 66839
SUBJECT: NRC INSPECTION REPORT 50 482/97 12
Dear Mr. Maynard:
An NRC inspection was conducted August 11-15,1997, at your Wolf Creek Generating
Station reactor facility. The enclosed report presents the scope and results of that
inspection.
The purpose of this inspection was primarily to evaluate the effectiveness of the licensed
operator requalification program. It also involved limited observations of control room
performance. Overall, the licensed operator requalification training program effectively
implemented a systems approach to training and maintained the condition of operators'
licenses. However, a number of simulator scenarios in the requalification scenario bank,
while acceptable overall, had limited discriminating value for the senior operator position,
in accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter
and its enclosure will be placed in the NRC Public Document Room (PDR),
Should you have any questions concerning this inspection, we will be pleased to discuss
them with you.
Sincerely,
.
a
j
-
Arthur T. Howell 11, Director
Division of Reactor Safety
J
Docket No.: 50-482
License No.: NPF-42
Enclosure:
NRC Inspection Report
50-482/97 12
mangI , \\\\0%
en~
9709090152 970904
llHhllEH, d.
i * -
ADOCK 05000402
- *
G
.
.
.
Wolf Creek Nuclear Operating Corporation
2-
cc w/ enclosure:
Chief Operating Officer
Wolf Creek Nuclear Operating Corp.
P.O. Box 411
Burlington, Kansas 66839
Jay Silberg, Esq.
Shaw, Pittman, Potts & Trowbridge
,
2300 N Street, NW
Washington, D.C. 20037
Supervisor Licensing
,
Wolf Creek Nuclear Operating Corp.
P.O. Box 411
Burlington, Kansas 66839
Chief Engineer
'
Utilities Division
Kansas Corporation Commission
1500 SW Arrowhead Rd.
Topeka, Kansas 66604 4027
Office of the Governor
State of Kansas
Topeka, Kansas 66612
Attorney General
Judicial Center
301 S.W.10th
2nd Floor
Topeka, Kansas 66612-1597
County Clerk
Coffey County Courthouse
Burlington, Kansas 66839 1798
Vick L. Cooper, Chief
Radiation Control Program
Kansas Department of Health
and Environment
Bureau of Air and Radiation
Forbes Field Building 283,
Topeka, Kansas 66620
.
.
.
.;
3
4
'
i
Wolf Creek Nuclear Operating Corporation
3-
Mr. Frank Moussa
- Division of Emergency Preparedness
2800 SW Topeka Blvd
Topeka, Kansas 66611-1287
l
l
l
l
I
I
I
..-
.
Wolf Creek Nuclear Operating Corporation
-4
E Mail report to T. Frye (TJF)
. E-mail report to T. Hiltz (TGH)
,
E-Mail report to NRR Event Tracking System (IPAS)
E-Mail report to Document Control Desk (DOCDESK)
bec to DCD (lE01)(IE45)--
bec distrib. by RIV:
Regional Administrator
Resident inspector
DRP Director
SRI (Callaway, RIV)
Branch Chief (DRP/B)
DRS-PSB
Project Engineer (DRP/B)
MIS System
Branch Chief (DRP/TSS)
RIV File
-. Bob Gallo (DRCH/HOLB)-
Laura Hurley, RIV
To receive copy of document, Indicato in box: "C" a Copy vnthout enclosures "E" = Copy with enclosures "ff = No copy
RIV;RE:OB
E
RE:OB
E
RE:Ogs,,-
E
BC:OBj
E
D:DRP
/4 D:DF(/
E
T @ OfvS,_
fl @ TZ
J)tgKERNON gjEQTeL
TPGwyn v7 AHO@)LL
08/xt97 /'
'08/p97
/OB/M97-
087[797
08/J97
@ @7
OFFICIAL RECO 3D COPY
'
_
_=
- _
. _ ___
_ _ _ _ _
_. ..
.
..
.
.
.
.
..
..
..
? .
.. g
.
Wolf Creek Nuclear Operating Corporation
-4-
E Mail report to T. Frye (TJF)
E-mail report to.T. Hiltz (TGH)
E-Mail report to NRR Event Tracking System (IPAS)
E-Mail report to Document Control Desk (DOCDESK)
bec to DCD (IE01)(I
)
,
bec distrib. by RIV:
Regional Administrator
Resident inspector
DRP Director
SRI (Callaway, RIV)
Branch Chief (DRP/B)
DRS-PSB
Project Engineer (DRP/B)
MIS System .
Branch Chief (DRP/TSS)
RIV File
Bob Gcilo (DRCH/HOLB)
Laura Hurley, RIV
..
To receive copy of document, indcato in box: "C" = Copy without enclosures "E" = Copy with enclosures "N" a No copy
RIV,:RE:OB
E
RE:OB
E
RE:O g .,.,
E
BC:OBj
E
D:DRP
A. D:DF@/
E
T@O)A/S,
RLA4(TZ
TMcRERNON pj544TrL
TPGwyn TY A_HO%)LL
08/M97 j'
'08/4/97-
LOB /A/97
08//797
08/ 397
gly b97
t
OFFICIAL RECORD COPY
'