- ML20236E298 + (07:24:36, 3 December 2024)
- ML20236E295 + (07:24:37, 3 December 2024)
- ML20236E293 + (07:24:38, 3 December 2024)
- ML20236E294 + (07:24:38, 3 December 2024)
- BECO-89-034, Monthly Operating Rept for Feb 1989 for Pilgrim Nuclear Power Station + (07:24:39, 3 December 2024)
- ML20236E291 + (07:24:39, 3 December 2024)
- 05000458/LER-1989-005, :on 890214,void Identified in Fire Seal Penetration Located on Wall Separating Cable Chase I from Chiller Room on 98-ft Elevation of Control Bldg.Caused by Poor Insp Technique.Firewatch Posted + (07:24:41, 3 December 2024)
- 05000298/LER-1989-003, :on 890213,emergency Diesel Generator Manually Shutdown & Declared Inoperable Due to Air Leak in 30 Psig Control Air Header.Caused by Inadequate Design Control. Supports Added & Tubing Rerouted to Minimize Cyclic Stress + (07:24:43, 3 December 2024)
- ML20236E287 + (07:24:43, 3 December 2024)
- ML20236E286 + (07:24:44, 3 December 2024)
- ML20236E285 + (07:24:44, 3 December 2024)
- ML20236E283 + (07:24:45, 3 December 2024)
- ML20236E282 + (07:24:46, 3 December 2024)
- ML20236E281 + (07:24:46, 3 December 2024)
- ML20236E278 + (07:24:47, 3 December 2024)
- NRC-89-0043, Application for Amend to License NPF-43,revising Tech Spec 3/4.6.3.1 to Delete Traversing in-core Probe Primary Containment Isolation Valve Since Penetration Will Be Sealed Closed Per Design Change + (07:24:47, 3 December 2024)
- ML20236E276 + (07:24:48, 3 December 2024)
- ML20236E275 + (07:24:49, 3 December 2024)
- ML20236E273 + (07:24:49, 3 December 2024)
- JPN-87-054, Forwards 10CFR170 Fee for 861221-870328 Insp + (07:24:50, 3 December 2024)
- 05000271/LER-1989-011, :on 890223,Group III Primary Containment Isolation Sys & Standby Gas Treatment Sys Initiation Occurred.Caused by High Radiation Signal When Local Power Range Monitor Came Close to Surface of Water + (07:24:52, 3 December 2024)
- ML20236E267 + (07:24:53, 3 December 2024)
- ML20236E265 + (07:24:53, 3 December 2024)
- ML20236E262 + (07:24:54, 3 December 2024)
- ML20236E264 + (07:24:54, 3 December 2024)
- ML20236E260 + (07:24:55, 3 December 2024)
- ML20236E256 + (07:24:56, 3 December 2024)
- ML20236E255 + (07:24:56, 3 December 2024)
- ML20236E253 + (07:24:57, 3 December 2024)
- ML20236E254 + (07:24:57, 3 December 2024)
- ML20236E249 + (07:24:59, 3 December 2024)
- ML20236E248 + (07:25:00, 3 December 2024)
- ML20236E247 + (07:25:01, 3 December 2024)
- ML20236E246 + (07:25:01, 3 December 2024)
- ML20236E242 + (07:25:02, 3 December 2024)
- ML20236E245 + (07:25:02, 3 December 2024)
- ML20236E241 + (07:25:03, 3 December 2024)
- ML20236E240 + (07:25:03, 3 December 2024)
- ML20236E237 + (07:25:05, 3 December 2024)
- 05000461/LER-1987-060, :on 871002,automatic Reactor Trip Occurred Due to Misoperation of non-class 1E 125 Volts Dc Breaker.Caused by Nonlicensed Operator.Nonlicensed Operator Counseled.One Line Diagram Relabeled + (07:25:06, 3 December 2024)
- ML20236E233 + (07:25:07, 3 December 2024)
- ML20236E232 + (07:25:08, 3 December 2024)
- ML20236E230 + (07:25:09, 3 December 2024)
- ML20236E231 + (07:25:09, 3 December 2024)
- ML20236E229 + (07:25:10, 3 December 2024)
- ML20236E228 + (07:25:10, 3 December 2024)
- ML20236E226 + (07:25:11, 3 December 2024)
- ML20236E225 + (07:25:12, 3 December 2024)
- ML20236E223 + (07:25:13, 3 December 2024)
- ML20236E219 + (07:25:17, 3 December 2024)
- ML20236E220 + (07:25:17, 3 December 2024)