ML20236E223

From kanterella
Jump to navigation Jump to search
Errata to Vogtle Unit 1 Readiness Review.Assessment of Georgia Power Company Readiness Review Pilot Program, Correcting Page 11,Paragraph (6) as Listed
ML20236E223
Person / Time
Site: Vogtle Southern Nuclear icon.png
Issue date: 10/31/1987
From: Lewis G
Office of Nuclear Reactor Regulation
To:
References
NUREG-1278, NUREG-1278-ERR, NUDOCS 8710290129
Download: ML20236E223 (1)


Text

___ - - -

. - _ _- ,\

A .. ,

.l ,

.; t UNITED STATES j.

3 NUCLEAR REGULATORY COMMISSION - .j Washington, D.C. 20555

$ r x.,*****f October 1987 '

1 l

l l

ERR ATA SHEET l 4

)

Report Number: NUREG-1278 l

.}

Report

Title:

.Vogtle Unit 1 Readiness Review: Assessment of Georgia '

Power Comp'any Readiness Review Pilot Program l

Prepared by: G. Lewis, U.S. Nuclear Regulatory Commission I Date Published: September 1987 l.

Instructions: On page 11, paragraph (6) should be changed as follows:

(6) GPC indicated its initial cost estimate to perform the readiness review of

$10M was exceeded; cost was approximately $13.5M. GPC indicated this was primarily due to GPC underestimating the amount of work required to ensure commitment tracking and the rework required of many of the readiness review modules. GPC initially estimated the cost of performing the-nesessapy seFFe6%4Ve-aGt4eRS-aS-a-FeSWit-ef all readiness review program activities would be $15M. The actual cost of all readiness review program activities was.approximately $30M.

Note deletions on lines 5 and 6.

B710290129 071031 PDR ADOCK 05000424-p PDR Division of Publications Services l

1.

L