- ML19341A259 + (22:35:41, 24 December 2024)
- 05000277/LER-1980-037, Forwards LER 80-037/01T-0 + (22:35:43, 24 December 2024)
- AECM-80-268, Submits Addl Info Re IE Bulletin 80-07, BWR Jet Pump Assembly Failure, in Response to NRC Request.Describes Actions to Preclude Occurrence of Jet Pump Cracking & Commitment for long-term Solution + (22:35:44, 24 December 2024)
- 05000278/LER-1980-031-03, /03L-0:on 801218,reactor Core Isolation Cooling Inboard Steam Supply Isolation Valve Did Not Automatically Close.Caused by Valve Closing Torque Switch on Type Smb Limitorque Operator for Valve MO3-13-15 Being Open + (22:35:46, 24 December 2024)
- 05000271/LER-1980-043-03, /03L-0:on 801220,reactor Core Isolation Cooling Valve 15 Had Seat Leakage of 1.531 Lbm/Hr,Exceeding Tech Specs.No Cause Noted.Valve Seating Surfaces Lapped & Valve Retested + (22:35:48, 24 December 2024)
- 05000271/LER-1980-043, Forwards LER 80-043/03L-0 + (22:35:50, 24 December 2024)
- 05000338/LER-1981-002-03, /03L-0:on 801231,pressurizer Power Operated Relief Valve Declared Inoperable Because of Low Nitrogen Gas Supply Tank Pressure in 1-GN-TK-1A.Caused by Excessive Usage of Nitrogen to Cycle Relief Valves to Reduce RCS Pressure + (22:35:51, 24 December 2024)
- 05000338/LER-1981-002, Forwards LER 81-002/03L-0 + (22:35:53, 24 December 2024)
- 05000346/LER-1980-093-03, /03L-0:on 801219,demineralized Water Containment Isolation Valve DW6831B Did Not Close in Required Time. Caused by Dump Solenoid Orifice Too Small to Allow Adequate Bleedoff Flow.Solenoid to Be Replaced + (22:35:55, 24 December 2024)
- 05000346/LER-1980-093, Forwards LER 80-093/03L-0 + (22:35:56, 24 December 2024)
- ML19341A245 + (22:35:57, 24 December 2024)
- 05000346/LER-1980-092-03, /03L-0:on 801219,isolation Valve from Main Steam Line to Auxiliary Feed Pump Turbine Failed to Close W/Simulated Low Pressure.Caused by Failed Couch Relay R1. New Relay Installed + (22:35:59, 24 December 2024)
- IR 05000348/1980035 + (22:36:01, 24 December 2024)
- ML19341A242 + (22:36:02, 24 December 2024)
- 05000346/LER-1980-092, Forwards LER 80-092/03L-0 + (22:36:03, 24 December 2024)
- 05000267/LER-1980-076-03, /03L-0:on 801216,results of Lab Carbon Sample Analysis of 1A Reactor Plant Exhaust Filter Showed Less Radioactive Methyl Iodine Removal Capability than Required. Caused by Normal Depletion of Activated Charcoal Adsorber + (22:36:08, 24 December 2024)
- ML19341A238 + (22:36:09, 24 December 2024)
- ML19341A236 + (22:36:10, 24 December 2024)
- ML19341A235 + (22:36:11, 24 December 2024)
- ML19341A233 + (22:36:12, 24 December 2024)
- ML19341A234 + (22:36:12, 24 December 2024)
- 05000267/LER-1980-076, Forwards LER 80-076/03L-0 + (22:36:14, 24 December 2024)
- ML19341A230 + (22:36:15, 24 December 2024)
- ML19341A229 + (22:36:16, 24 December 2024)
- 05000324/LER-1980-115-03, /03L-0:on 801222,reactor Vessel Conductivity, Exceeded 2 umho/cm2 for 27.3-h W/Highest Measured Value at 3.35 umho/cm2.Caused by High Conductivity Condensate in Heater Drains Sys Being Concentrated in Vessel + (22:36:17, 24 December 2024)
- ML19341A226 + (22:36:19, 24 December 2024)
- 05000324/LER-1980-115, Forwards LER 80-115/03L-0 + (22:36:20, 24 December 2024)
- ML19341A223 + (22:36:21, 24 December 2024)
- ML19341A221 + (22:36:22, 24 December 2024)
- 05000325/LER-1981-001-01, /01T-0:on 810103,feed Pump Tripped on High Vessel Level Due to safety-relief Valve B21-F013G,Model 67F,lift. Caused by High Second Stage & Pilot Leakage in Valve.Pilot Valve Temporarily Replaced Until Next Scheduled Outage + (22:36:23, 24 December 2024)
- 05000325/LER-1981-001, Forwards LER 81-001/01T-0 + (22:36:24, 24 December 2024)
- ML19341A217 + (22:36:25, 24 December 2024)
- 05000325/LER-1980-092-03, /03L-0:on 801220,reactor Vessel Conductivity Measured Over Tech Spec Level.Caused by Removal of Reactor Water Cleanup Sys from Svc for Valve Maint.Valves Repaired & Sys Returned to Svc + (22:36:27, 24 December 2024)
- 05000325/LER-1980-092, Forwards LER 80-092/03L-0 + (22:36:28, 24 December 2024)
- 05000334/LER-1980-118-03, /03L-0:on 801217,during Chlorine Detection Sys Surveillance test,101A,B & C Detectors Electrolyte Found Not Dripping.Caused by Vacuums in Fluid Tanks & Clogged Glass Orifices.Wicks Replaced & Orifices Cleaned + (22:36:30, 24 December 2024)
- ML19341A212 + (22:36:32, 24 December 2024)
- 05000318/LER-1980-052-03, /03L-0:on 801103,CTMT Penetration Room Exhaust Fan Discharge Damper 22 Linkage Was Found Broken.Caused by Excessive Wear on Clevis Pin Due to Inadequate Lubrication. Linkage Repaired & Restored to Svc on 801104 + (22:36:33, 24 December 2024)
- 05000318/LER-1980-052, Forwards LER 80-052/03L-0 + (22:36:35, 24 December 2024)
- 05000334/LER-1980-114-03, /03L-0:on 801215,during Shift Channel Check of Refueling Water Storage Tank,Channel C Level Indicator Found Reading High.Caused by Transmitter Zero Drift. Transmitter Recalibr & Returned to Svc + (22:36:37, 24 December 2024)
- 05000334/LER-1980-113-03, /03L-0:on 801214,during Surveillance Testing, Several Penetration Fire Barriers Found Lacking Seals. Caused Not Stated.Fire Watch Posted & Openings Sealed + (22:36:39, 24 December 2024)
- ML19341A206 + (22:36:40, 24 December 2024)
- ML19341A204 + (22:36:40, 24 December 2024)
- ML19341A202 + (22:36:47, 24 December 2024)
- ML19341A203 + (22:36:47, 24 December 2024)
- ML19341A201 + (22:36:49, 24 December 2024)
- ML19341A199 + (22:36:50, 24 December 2024)
- ML19341A200 + (22:36:50, 24 December 2024)
- ML19341A197 + (22:36:51, 24 December 2024)
- ML19341A196 + (22:36:51, 24 December 2024)
- ML19341A193 + (22:36:52, 24 December 2024)
- ML19341A195 + (22:36:52, 24 December 2024)