- ML20002B084 + (20:56:10, 23 December 2024)
- ML20002B085 + (20:56:10, 23 December 2024)
- 05000265/LER-1980-030-03, /03L-0:on 801031,primary Containment Valve AO-2-1601-63 Required 30-s to Close.Caused by Malfunction of Pilot Solenoid SO-2-1601-71.Solenoid Replaced & Tested + (20:56:12, 23 December 2024)
- ML20002B082 + (20:56:12, 23 December 2024)
- ML20002B080 + (20:56:14, 23 December 2024)
- ML20002B081 + (20:56:14, 23 December 2024)
- ML20002B079 + (20:56:15, 23 December 2024)
- ML20002B078 + (20:56:15, 23 December 2024)
- ML20002B076 + (20:56:16, 23 December 2024)
- ML20002B077 + (20:56:16, 23 December 2024)
- 05000338/LER-1980-097-03, /03L-0:on 801114,while Operating in Mode 1,LI-1474 Indicated Greater than 5% Higher than Average of Three Channels.Caused by High Transmitter Output,Due to Leaking Isolation Valve.Valves Furmanited.Channel Check Performed + (20:56:17, 23 December 2024)
- ML20002B070 + (20:56:21, 23 December 2024)
- 05000306/LER-1980-035-03, /03L-0:on 801103,remote/local Control Switch on Containment Spray Pump 21 Found Not in Remote Position. Caused by Contractor Workman Bumping Switch.Switch Returned to Remote Position + (20:56:23, 23 December 2024)
- 05000338/LER-1980-097, Forwards LER 80-097/03L-0 + (20:56:24, 23 December 2024)
- ML20002B066 + (20:56:25, 23 December 2024)
- 05000312/LER-1980-046-03, /03L-0:on 801104 & 1128,overspeed Trip Lever on Turbine for Automatic Feedwater Pump P-318 Was Found in Apparent Tripped Condition.Cause Could Not Be Determined. Daily Visual Checks Initiated + (20:56:27, 23 December 2024)
- ML20002B064 + (20:56:28, 23 December 2024)
- 05000306/LER-1980-035, Forwards LER 80-035/03L-0 + (20:56:29, 23 December 2024)
- 05000320/LER-1980-049-01, /01L-0:on 801027,ASME Code Stamped UV Valve LTB-V171 Discovered Stamped by Unauthorized Valve Supply House.Caused by Unauthorized Use of ASME UV Code Stamp by North American Safety Valve Industries,Inc + (20:56:34, 23 December 2024)
- ML20002B056 + (20:56:36, 23 December 2024)
- 05000334/LER-1980-087-03, /03L-0:on 801113,operator Attempted to Perform Operation Surveillance Test on Intermediate Range Nuclear Instrument While Reactor Was Critical.Caused by Operator Error & Possible Inadequate Situational Analysis Guidance + (20:56:37, 23 December 2024)
- 05000312/LER-1980-046, Forwards LER 80-046/03L-0 + (20:56:39, 23 December 2024)
- 05000334/LER-1980-087, Forwards LER 80-087/03L-0 + (20:56:40, 23 December 2024)
- 05000346/LER-1980-080-03, /03L-0:on 801103,during Testing,Control Rod Drive Trip Breaker C Did Not Trip.Cause Could Not Be Determined. Breaker Was Manually Put in Tripped Position within 5 Minutes of Failure + (20:56:47, 23 December 2024)
- ML20002B047 + (20:56:48, 23 December 2024)
- 05000321/LER-1980-117-03, /03L-0:on 801104,no Transfer Authorizations Discovered for Receipt of Two Shipments of Low Power Range Monitors & One Shipment of Source Range & Radiation Monitors.Caused by Misinterpretation of Procedures + (20:56:49, 23 December 2024)
- 05000320/LER-1980-049, Forwards LER 80-049/01L-0 + (20:56:51, 23 December 2024)
- 05000282/LER-1980-036-03, /03L:on 801105,battery Charger 12 Failed to Provide Normal Output.Caused by Firing Card B Not Providing Pulses to Fire B Phase Scr.Card Replaced + (20:56:53, 23 December 2024)
- 05000346/LER-1980-080, Forwards LER 80-080/03L-0 + (20:56:55, 23 December 2024)
- 05000321/LER-1980-117, Forwards LER 80-117/03L-0 + (20:56:56, 23 December 2024)
- ML20002B038 + (20:56:57, 23 December 2024)
- 05000282/LER-1980-036, Forwards LER 80-036/03L-0 + (20:57:01, 23 December 2024)
- ML20002B032 + (20:57:05, 23 December 2024)
- 05000409/LER-1980-016-01, /01T-0:on 801202,hourly Fire Watch Patrol Not Established within 1-h of Drilling Holes Through Turbine Bldg Barriers for Fire Protection & Sampling Sys.Job Coordinators Reminded of Fire Barrier Requirements + (20:57:06, 23 December 2024)
- 05000409/LER-1980-016, Forwards LER 80-016/01T-0 + (20:57:08, 23 December 2024)
- 05000213/LER-1980-016-03, /03L-0:on 801118,audible & Visual Alarms Indicated Two Dropped Rods & Initiation of Turbine Load Runback.Caused by Badly Burnt Arc Chute & Auxiliary Contacts on One Side of Type MM310 Contactor Rubbing & Impeding Operation + (20:57:10, 23 December 2024)
- ML20002B027 + (20:57:11, 23 December 2024)
- 05000213/LER-1980-016, Forwards LER 80-016/03L-0 + (20:57:12, 23 December 2024)
- 05000324/LER-1980-092-03, /03L-0:on 801106,08,12,15,18,22 & 23,containment Atmospheric Monitor 2-CAC-AT-1259,Beckman Model F3,tripped Due to Loss of Sample Flow.Caused by Water Accumulation in Torus Sample Line to Monitor.Water Removed + (20:57:14, 23 December 2024)
- 05000324/LER-1980-092, Forwards LER 80-092/03L-0 + (20:57:16, 23 December 2024)
- ML20002B021 + (20:57:17, 23 December 2024)
- ML20002B019 + (20:57:18, 23 December 2024)
- ML20002B020 + (20:57:18, 23 December 2024)
- ML20002B018 + (20:57:19, 23 December 2024)
- ML20002B017 + (20:57:20, 23 December 2024)
- ML20002B016 + (20:57:21, 23 December 2024)
- 05000338/LER-1980-098-03, /03L-0:on 801123,while Operating in Mode 1,neutron Flux Distribution Exceeded Axial Flux Difference Target Band.Caused by Xenon Transient.Control Rods Inserted,Causing Flux Distribution to Shift Downward + (20:57:22, 23 December 2024)
- 05000338/LER-1980-098, Forwards LER 80-098/03L-0 + (20:57:24, 23 December 2024)
- 05000301/LER-1980-009-03, /03L-0:on 801101,during Normal Operation, Performance of ICP 2.14 Found P8 Permissive Bistable from Channel N44 to Be Set at 50.5%.Caused by Instrument Drift. Bistable Adjusted & Tested Satisfactorily + (20:57:25, 23 December 2024)
- ML20002B011 + (20:57:26, 23 December 2024)
- ML20002B009 + (20:57:27, 23 December 2024)