Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- IR 05000483/1981019 + (10:59:52, 21 December 2024)
- ML20010G290 + (10:59:54, 21 December 2024)
- PNO-II-81-069, on 810909,emergency Drill Exercise Initiated W/Rept of Simulated Small Seismic Event + (10:59:56, 21 December 2024)
- 05000368/LER-1981-026-03, /03L-0:on 810714,refueling Water Tank Discharge Valve 2CV-5630 Failed in Open Position on Safety Injection Actuation Signal Rendering Valve Inoperable to Recirculation Actuation Signal.Caused by Burned Up Valve Motor + (10:59:57, 21 December 2024)
- ML20010G283 + (11:00:00, 21 December 2024)
- IR 05000341/1981012 + (11:00:02, 21 December 2024)
- 05000293/LER-1981-043-01, /01T-0:on 810713,outer Drywell Personnel Access Door Discovered to Have Leak Rate Exceeding Tech Spec Limits During Sp.Caused by Leaking Seal Due to Normal Inservice Degradation.Leak Rate Test Procedures Revised + (11:00:04, 21 December 2024)
- PNO-II-81-071, on 810909,while Transferring Sludge/Resin Slurry from Waste Collection Tank to Waste Sludge Tank,Hose Ruptured,Spraying Workers W/Sludge.Four Individuals Were Decontaminated + (11:00:07, 21 December 2024)
- ML20010G275 + (11:00:08, 21 December 2024)
- 05000369/LER-1981-135-03, /03L-0:on 810807,found Surveillance Requirement Not Being Accomplished Completely Due to Exclusion of Control Components from Test Procedure.Caused by Failure to Update Test Procedures.Test Modified + (11:00:13, 21 December 2024)
- 05000368/LER-1981-026, Forwards LER 81-026/03L-0 + (11:00:15, 21 December 2024)
- 05000267/LER-1981-046-03, /03L-0:on 810728,emergency Feedwater Supply to Loop 1 Helium Circular Water Turbines Isolated to Repair Leaking 2-inch Consolidated Safety Relief Valves.Caused by Valve Leakage Downstream of Pressure Control Valve + (11:00:16, 21 December 2024)
- ML20010G270 + (11:00:17, 21 December 2024)
- ML20010G267 + (11:00:20, 21 December 2024)
- 05000298/LER-1981-021-03, /03L-0:on 810728,during Performance of Surveillance Procedure on Diesel Generator 2,injection Line Failed.Caused by Metal Fatigue & Vibration.Component Replaced + (11:00:22, 21 December 2024)
- 05000267/LER-1981-046, Forwards LER 81-046/03L-0.Detailed Event Analysis Encl + (11:00:24, 21 December 2024)
- 05000295/LER-1981-035-03, /03L-0:on 810806,containment Gas & Particulate Radiation Monitor 1RE-0011 & 12 Failed.Caused by Monitor Blower Tripping Due to Mechanical Seizure.New Blower Installed & Monitor Reset + (11:00:26, 21 December 2024)
- 05000293/LER-1981-043, Forwards LER 81-043/01T-0 + (11:00:28, 21 December 2024)
- 05000368/LER-1981-025-03, Fire Developed on Exhaust Header of Diesel Engine.Caused by Oil Soaked Insulation Igniting When Exhaust Temp Reached Approx 1000 F.Manifold Cleaned & Gasket Changed + (11:00:29, 21 December 2024)
- 05000298/LER-1981-021, Forwards LER 81-021/03L-0.Detailed Event Rept Submitted + (11:00:31, 21 December 2024)
- 05000369/LER-1981-135, Forwards LER 81-135/03L-0 + (11:00:33, 21 December 2024)
- ML20010G255 + (11:00:34, 21 December 2024)
- ML20010G254 + (11:00:35, 21 December 2024)
- A810024, Responds to IE Bulletin 81-02,Suppl 1, Failure of Gate Type Valves to Close Against Differential Pressure. as Indicated in Util ,Facility Has No Subj Valves. No Further Action Planned + (11:00:36, 21 December 2024)
- ML20010G252 + (11:00:36, 21 December 2024)
- 05000368/LER-1981-025, Forwards Updated LER 81-025/03X-1 + (11:00:40, 21 December 2024)
- ML20010G248 + (11:00:41, 21 December 2024)
- 05000295/LER-1981-035, Forwards LER 81-035/03L-0 + (11:00:43, 21 December 2024)
- ML20010G244 + (11:00:48, 21 December 2024)
- PNO-IV-81-025, on 810902,H&H X-Ray Svcs,Inc Reported Highway Accident Involving Mobile Radiographic Vehicle in Ok.Truck Carried Radiographic Device Containing Approx 40 Ci Ir-192 + (11:00:50, 21 December 2024)
- ML20010G242 + (11:00:51, 21 December 2024)
- IR 05000313/1981009 + (11:00:53, 21 December 2024)
- TXX-3352, Forwards Response to IE Bulletin 81-03, Flow Blockage of Cooling Water to Safety Sys Components by Corbicula Sp (Asiatic Clam) & Mytilus Sp (Mussel). No Clams Found.Mussel Not Evident + (11:00:54, 21 December 2024)
- ML20010G237 + (11:00:55, 21 December 2024)
- ML20010G234 + (11:00:58, 21 December 2024)
- IR 05000334/1981012 + (11:00:59, 21 December 2024)
- IR 05000498/1981019 + (11:01:02, 21 December 2024)
- ML20010G227 + (11:01:03, 21 December 2024)
- ML20010G225 + (11:01:03, 21 December 2024)
- ML20010G222 + (11:01:06, 21 December 2024)
- IR 05000352/1981011 + (11:01:08, 21 December 2024)
- 05000316/LER-1981-041-03, /03L-0:on 810806,RCS Unidentified Leakage Exceeded Tech Spec Limit.Caused by Packing Leak on Valve RC-10811. Valve Repacked.Resistance Temp Detector Loop Hand Valves to Be Checked for Packing Leaks During Next Outage + (11:01:09, 21 December 2024)
- ML20010G219 + (11:01:11, 21 December 2024)
- ML20010G217 + (11:01:12, 21 December 2024)
- ML20010G215 + (11:01:13, 21 December 2024)
- ML20010G213 + (11:01:13, 21 December 2024)
- 05000316/LER-1981-041, Forwards LER 81-041/03L-0 + (11:01:15, 21 December 2024)
- FVY-81-130, Responds to IE Bulletin 81-02,Suppl 1, Failure of Gate Type Valves to Close Against Differential Pressure. Affected Valves Are Not Installed or Maintained as Spares at Facility.Response Required 16 Manhours + (11:01:16, 21 December 2024)
- ML20010G208 + (11:01:16, 21 December 2024)
- ML20010G206 + (11:01:19, 21 December 2024)
- ML20010G205 + (11:01:23, 21 December 2024)