- ML20011A563 + (10:01:34, 21 December 2024)
- ML20011A562 + (10:01:36, 21 December 2024)
- ML20011A561 + (10:01:37, 21 December 2024)
- 05000255/LER-1981-036-01, /01T-0:on 810920,during Penetration Surveillance Test,Total as-found Leakage from All Penetrations & Isolation Valves Exceeded Limits.Cause Undetermined But Failure of Penetration 52 Isolation Valves Suspected + (10:01:39, 21 December 2024)
- ML20011A559 + (10:01:40, 21 December 2024)
- ML20011A557 + (10:01:40, 21 December 2024)
- 05000255/LER-1981-036, Forwards LER 81-036/01T-0 + (10:01:42, 21 December 2024)
- ML20011A554 + (10:01:43, 21 December 2024)
- 05000301/LER-1981-007-03, /03L-0:on 810902,boric Acid Heat Trace Circuit P131 Found Inoperative.Caused by Failed Fuse Holder.Fuse Holder Replaced & Boric Acid Heat Trace Circuit Returned to Svc + (10:01:45, 21 December 2024)
- 05000305/LER-1981-030-03, /03L-0:on 810903,surveillance Procedure Found to Incorrectly Measure Shield Bldg Vent Sys Exhaust Flow from Annulus.Caused by Surveillance Procedures Written to Demonstrate Original Design Criteria + (10:01:46, 21 December 2024)
- ML20011A550 + (10:01:49, 21 December 2024)
- 05000301/LER-1981-007, Forwards LER 81-007/03L-0 + (10:01:50, 21 December 2024)
- ML20011A546 + (10:01:54, 21 December 2024)
- ML20011A543 + (10:01:57, 21 December 2024)
- 05000249/LER-1981-021, Forwards LER 81-021/03L-0 + (10:01:58, 21 December 2024)
- ML20011A540 + (10:01:59, 21 December 2024)
- 05000305/LER-1981-030, Forwards LER 81-030/03L-0 + (10:02:01, 21 December 2024)
- ML20011A537 + (10:02:02, 21 December 2024)
- ML20011A535 + (10:02:03, 21 December 2024)
- ML20011A536 + (10:02:03, 21 December 2024)
- ML20011A534 + (10:02:05, 21 December 2024)
- IR 05000483/1978001 + (10:02:15, 21 December 2024)
- ML20011A532 + (10:02:16, 21 December 2024)
- ML20011A531 + (10:02:18, 21 December 2024)
- ML20011A530 + (10:02:19, 21 December 2024)
- 05000155/LER-1981-022-01, /01T-0:on 810917,during Preparation for Removal of One Reactor Depressurizing Loop from Svc,Error in Performing Written Switching Order Resulted in Inoperability of Two Loops.Second Loop Restored to Svc.Procedure Reviewed + (10:02:24, 21 December 2024)
- ML20011A528 + (10:02:25, 21 December 2024)
- 05000254/LER-1981-016-03, /03L-0:on 810902,required Surveillance Testing Not Performed Prior to Making Sgtts Train Inoperable.Caused by Personnel Error.Individuals Instructed on Need to Adhere to Procedures + (10:02:27, 21 December 2024)
- ML20011A526 + (10:02:29, 21 December 2024)
- 05000155/LER-1981-022, Forwards LER 81-022/01T-0 + (10:02:30, 21 December 2024)
- IR 05000483/1977011 + (10:02:39, 21 December 2024)
- ML20011A522 + (10:02:41, 21 December 2024)
- ML20011A520 + (10:02:45, 21 December 2024)
- ML20011A519 + (10:02:46, 21 December 2024)
- 05000254/LER-1981-016, Forwards LER 81-016/03L-0 + (10:02:47, 21 December 2024)
- ML20011A514 + (10:02:51, 21 December 2024)
- ML20011A513 + (10:02:52, 21 December 2024)
- 05000293/LER-1981-051-01, /01T-0:on 810917,while Conducting Surveillance Test 8.5.2.1,water Was Observed Coming from RHR Piping.Caused by Fatigue Due to Vibration + (10:02:59, 21 December 2024)
- 05000321/LER-1981-095-03, /03L-0:on 810908,reactor Core Isolation Cooling Steam Line Delta P Switch Actuated at Level Outside Tech Specs Range.Caused by Setpoint Drift.Switch Recalibr.Rept Will Be Updated When Switch Is Replaced + (10:03:04, 21 December 2024)
- ML20011A506 + (10:03:05, 21 December 2024)
- ML20011A503 + (10:03:09, 21 December 2024)
- IR 05000483/1978003 + (10:03:12, 21 December 2024)
- 05000293/LER-1981-051, Forwards LER 81-051/01T-0 + (10:03:13, 21 December 2024)
- ML20011A494 + (10:03:19, 21 December 2024)
- 05000366/LER-1981-089-03, /03L-0:on 810913,during steady-state Operation, Torus Water Level Indicator Was Reading Greater than 200 Inches of Water.Caused by Leaking Equalizing Valve & Draining of Transmitter Leg.Leg Backfilled & Valve Repaired + (10:03:21, 21 December 2024)
- ML20011A491 + (10:03:22, 21 December 2024)
- 05000029/LER-1981-026-03, /03L-0:on 810902,primary Vent Stack Gaseous Radiation Monitoring Ratemeter Failed High.Caused by Failed Electronic Component in Detector.Detector Replaced + (10:03:24, 21 December 2024)
- ML20011A489 + (10:03:25, 21 December 2024)
- ML20011A488 + (10:03:26, 21 December 2024)
- ML20011A487 + (10:03:27, 21 December 2024)
- ML20011A486 + (10:03:29, 21 December 2024)