- ML20024A480 + (05:46:09, 21 December 2024)
- ML20024A478 + (05:46:10, 21 December 2024)
- 05000312/LER-1983-016-03, /03L-0:on 830331,during Surveillance Testing on snubbers,10 Snubbers Mfg by Grinnell & Bergen-Patterson Failed Acceptance Criteria.Caused by Defective Seals,Body Corrosion & Water in Fluid.Valves Rebuilt + (05:46:11, 21 December 2024)
- ML20024A476 + (05:46:12, 21 December 2024)
- ML20024A474 + (05:46:13, 21 December 2024)
- ML20024A472 + (05:46:14, 21 December 2024)
- ML20024A473 + (05:46:14, 21 December 2024)
- 05000213/LER-1983-009-03, /03L-0:on 830505,charging Pump a Could Not Be Manually Rotated for Routine Surveillance Test.Caused by Binding Due to Solidified Boric Acid.Pump Uncoupled from Motor & Turned Over + (05:46:16, 21 December 2024)
- IR 05000382/1983009 + (05:46:17, 21 December 2024)
- 05000265/LER-1983-008-03, /03L-0:on 830520,RHR Pump 2B Room Watertight Door Could Not Be Shut Tightly.Caused by Bent Pivot Arm.Arm Repaired & RHR B Loop Declared Operable + (05:46:19, 21 December 2024)
- PNO-I-83-060, on 830614,reactor Tripped from 100% Power Due to High Radiation Signal Sensed in Main Steam Lines.Caused by Air Pocket in Steam Lines.Safety Relief Valve Cycled & RCIC Manually Restarted + (05:46:22, 21 December 2024)
- ML20024A464 + (05:46:23, 21 December 2024)
- ML20024A465 + (05:46:23, 21 December 2024)
- 05000029/LER-1983-016-03, /03L-0:on 830511,containment Isolation Valve TV-CI-401B & Steam Generator 2 Blowdown Monitor Isolated to Repair Gasket Leak.Caused by Bottom Flange Gasket Failure. Gasket Replaced + (05:46:25, 21 December 2024)
- 05000272/LER-1983-022-04, /04L-0:on 830513,estimated 131 Uci of Activity Released When 350 Gallons Low Level Radioactive Water Pumped Into Ground.Caused by Contaminated Piping Penetration Area. Control Measures Implemented + (05:46:27, 21 December 2024)
- 05000331/LER-1983-021-01, /01T-0:on 830527,containment H202 Analyzer Channel a Rendered Inoperable.Caused by Calibr Difficulties Due to Fouled Pressure Regulators Resulting from Sys Contamination. Tech Specs Revised + (05:46:29, 21 December 2024)
- ML20024A459 + (05:46:30, 21 December 2024)
- ML20024A460 + (05:46:30, 21 December 2024)
- PNO-I-83-061, on 830615,while Conducting Mod to Reactor Water Level Sensing Lines,False Low Reactor Water & low-low Reactor Water Level Signals Generated,Initiating ECCS & Starting Emergency Diesel Generators + (05:46:32, 21 December 2024)
- ML20024A457 + (05:46:33, 21 December 2024)
- 05000247/LER-1983-020-03, /03L-0:on 830420,high Steam Flow Bistable FC449A Setpoint Found Higher than Tech Spec Limit.Caused by Defective Internal Dc Power Supply Board.Board Replaced & Bistable Reset + (05:46:35, 21 December 2024)
- ML20024A455 + (05:46:37, 21 December 2024)
- ML20024A453 + (05:46:38, 21 December 2024)
- ML20024A454 + (05:46:38, 21 December 2024)
- ML20024A451 + (05:46:39, 21 December 2024)
- 05000344/LER-1983-005-03, /03L-0:on 830504,pressurizer Level Transmitter LT-461 Found Out of Calibr.Caused by Instrument Drift. Instrument Recalibr + (05:46:40, 21 December 2024)
- ML20024A449 + (05:46:42, 21 December 2024)
- ML20024A448 + (05:46:42, 21 December 2024)
- ML20024A447 + (05:46:43, 21 December 2024)
- ML20024A446 + (05:46:44, 21 December 2024)
- IR 05000269/1983014 + (05:46:45, 21 December 2024)
- ML20024A444 + (05:46:46, 21 December 2024)
- ML20024A443 + (05:46:47, 21 December 2024)
- 05000213/LER-1983-010-03, /03L-0:on 830507,following Svc Water Low Flow Alarm,Svc Water Filters Indicated 0 Psi.Caused by Filter B Plugging Up W/River Silt Due to Rain & High River Conditions.Filter a Cleaned + (05:46:49, 21 December 2024)
- ML20024A441 + (05:46:50, 21 December 2024)
- ML20024A439 + (05:46:51, 21 December 2024)
- ML20024A440 + (05:46:51, 21 December 2024)
- ML20024A438 + (05:46:52, 21 December 2024)
- PNO-II-83-047, on 830613,standby Gas Treatment Sys Train B Declared Inoperable Due to Problems W/Filter Heaters.Cause Not Stated.Event Involved No Equipment Damage,No Personnel Error or Injury & No Radioactive Releases + (05:46:54, 21 December 2024)
- ML20024A436 + (05:46:54, 21 December 2024)
- 05000312/LER-1983-022-03, /03L-0:on 830507,cooling Water to Reactor Bldg Emergency Cooling Unit a 500c Motor Found to Be Drawing Locked Rotor Current Preventing Valve from Stroking.Female Control Disconnect Switch Found Spread Apart + (05:46:56, 21 December 2024)
- ML20024A434 + (05:47:00, 21 December 2024)
- ML20024A432 + (05:47:00, 21 December 2024)
- ML20024A431 + (05:47:03, 21 December 2024)
- ML20024A429 + (05:47:03, 21 December 2024)
- ML20024A428 + (05:47:04, 21 December 2024)
- ML20024A427 + (05:47:05, 21 December 2024)
- ML20024A426 + (05:47:05, 21 December 2024)
- 05000277/LER-1983-010-03, /03L-0:on 830427,sample Line Flow Meter Indicated No Flow & 3-way Selector Valve SV-2524 Found Stuck.Caused by Dirt Buildup Inside Solenoid Valve, (Asco Model S-36-734). Valve Tapped & Flow Returned + (05:47:07, 21 December 2024)
- IR 05000295/1982030 + (05:47:08, 21 December 2024)