Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20024C061 + (05:15:47, 21 December 2024)
- ML20024C059 + (05:15:48, 21 December 2024)
- ML20024C057 + (05:15:49, 21 December 2024)
- ML20024C056 + (05:15:50, 21 December 2024)
- ML20024C055 + (05:15:51, 21 December 2024)
- IR 05000289/1983009 + (05:15:52, 21 December 2024)
- ML20024C051 + (05:15:53, 21 December 2024)
- ML20024C050 + (05:15:54, 21 December 2024)
- ML20024C049 + (05:15:55, 21 December 2024)
- ML20024C047 + (05:15:56, 21 December 2024)
- ML20024C048 + (05:15:56, 21 December 2024)
- ML20024C046 + (05:15:57, 21 December 2024)
- ML20024C044 + (05:15:58, 21 December 2024)
- ML20024C043 + (05:15:59, 21 December 2024)
- ML20024C042 + (05:16:00, 21 December 2024)
- ML20024C040 + (05:16:01, 21 December 2024)
- 05000370/LER-1983-019-01, /01T-0:on 830526,containment Pressure Control Sys Monthly Test Failed to Satisfy Surveillance Requirements to Check Permissive/Termination Setpoint Accuracy.Caused by out-of-tolerance Instruments.Modules Recalibr + (05:16:02, 21 December 2024)
- ML20024C038 + (05:16:04, 21 December 2024)
- 05000395/LER-1983-057-03, /03L-0:on 830606,nitrogen Low Pressure Alarm on Low Pressure Accumulator for PORV Received in Control Room. Caused by Valve Position Indicator Lights Not Showing Full Actual Position.Limit Switches Adjusted + (05:16:06, 21 December 2024)
- ML20024C035 + (05:16:07, 21 December 2024)
- ML20024C036 + (05:16:07, 21 December 2024)
- ML20024C034 + (05:16:08, 21 December 2024)
- ML20024C030 + (05:16:12, 21 December 2024)
- ML20024C029 + (05:16:13, 21 December 2024)
- 05000389/LER-1983-020-03, /03L-0:on 830606,safety Injection Tank 2A2 Depressurized to 565 Psig During Filling.Caused by Relief Valve V-3466 Lifting During Filling & Operator Unaware of Pressure Restrictions.Operator Reinstructed + (05:16:14, 21 December 2024)
- ML20024C024 + (05:16:17, 21 December 2024)
- 05000389/LER-1983-019-03, /03L-0:on 830603,position Indication Lights for PORV 1475 Discovered Out.Caused by Failure of Magnetic Slug Located on Valve Stem.Slug Replaced W/New Magnet W/Annealed Metal + (05:16:18, 21 December 2024)
- ML20024C022 + (05:16:20, 21 December 2024)
- ML20024C021 + (05:16:21, 21 December 2024)
- 05000335/LER-1983-027-03, /03L-0:on 830531,periodic Surveillance of Fuel Handling Bldg Area Radiation Monitors Not Performed Per Tech Specs.Caused by Incorrect Surveillance Procedure & Personnel Error.Procedure Revised + (05:16:22, 21 December 2024)
- ML20024C018 + (05:16:24, 21 December 2024)
- ML20024C015 + (05:16:25, 21 December 2024)
- 05000317/LER-1981-080-03, Discovered Weep from Cracked Weld on Spent Fuel Cooling Pump Discharge Vent Line 12.Caused by Inadequate Support of Vent Line.Support Assembly Installed + (05:16:26, 21 December 2024)
- 05000389/LER-1983-018-03, /03L-0:on 830531,during Initial Startup,Inner Equalizing Valve of Personnel Air Lock Did Not Shut.Caused by Broken Valve Operating Linkage.Valve Replaced & Linkage Repaired + (05:16:29, 21 December 2024)
- ML20024C006 + (05:16:34, 21 December 2024)
- 05000369/LER-1983-030-01, /01T-0:on 830526,discovered Monthly Test of Containment Pressure Control Sys Failed to Satisfy Surveillance Requirements to Check Permissive/Termination Setpoint Accuracy.Alarm Modules Recalibr + (05:16:36, 21 December 2024)
- ML20024B995 + (05:16:40, 21 December 2024)
- 05000416/LER-1983-072-01, /01T-0:on 830615,operations Shift Supervisor Discovered Some Continuous Fire Watches Not Performed on 830614.Caused by Personnel Error.Personnel Reinstructed Not to Pull Fire Watch W/O Approval + (05:16:41, 21 December 2024)
- ML20024B993 + (05:16:42, 21 December 2024)
- 05000366/LER-1983-037-03, /03L-0:on 830603,during Performance of Procedure HNP-2-5622,personnel Noted Hydrogen Recombiner Controllers Out of Calibr.Caused by Setpoint Drift Due to Miscellaneous Failed Parts.Controllers Recalibr + (05:16:44, 21 December 2024)
- ML20024B990 + (05:16:45, 21 December 2024)
- 05000339/LER-1983-047-03, /03L-0:on 830530,emergency Diesel Generator 2J Tripped on High Crankcase Pressure During Surveillance Testing.Cause Not Determined.Diesel Tested Satisfactorily + (05:16:46, 21 December 2024)
- 05000270/LER-1983-008-03, /03L-0:on 830531,motor Driven Emergency Feedwater Pump Became Inoperable When Power Removed from Circuitry for Repair of Automatic Initiation Switch 2PS-388.Caused by Component Failure.Switch Replaced & Recalibr + (05:16:48, 21 December 2024)
- 05000267/LER-1983-020-03, /03L-0:on 830604,emergency Feedwater Header Supply to Loop I Helium Circulator Turbine Water Drive Isolated & Bearing Water Make Up Pump Taken Out of Svc.Caused by Flexitallic Gasket Failure Due to Normal Wear + (05:16:52, 21 December 2024)
- 05000327/LER-1983-084-03, /03L-0:on 830603,two Upper Head Injection Level Switches 1-LS-87-22 & 23 Declared Inoperable.Caused by Setpoint Drift.Switches Recalibr + (05:16:54, 21 December 2024)
- ML20024B984 + (05:16:55, 21 December 2024)
- 05000309/LER-1983-022, Updated LER 83-022/01T-1:on 830621,during Survey of Safety Class Piping,Certain Sections of Piping Identified on Which Lead Radiation Shielding Installed W/O Engineering Evaluation.Shielding Removed + (05:16:57, 21 December 2024)
- 05000395/LER-1983-056-03, /03L-0:on 830606,feedwater Flow Transmitter (FT-468) Steam Generator B Failed Low.Caused by Failure of Power Supply Card.Card Replaced + (05:16:59, 21 December 2024)
- ML20024B980 + (05:17:00, 21 December 2024)
- 05000296/LER-1983-033-03, /03L-0:on 830601,diesel Generator 3EA Lube Oil Circulating Pump Motor Tripped Off.Caused by Failure of Motor Bearings.Delco Model 12724-Y1 Motor Replaced + (05:17:01, 21 December 2024)
- ML20024B978 + (05:17:03, 21 December 2024)