- ML20032C531 + (16:41:45, 20 December 2024)
- ML20032C529 + (16:41:46, 20 December 2024)
- 05000334/LER-1981-090-03, /03L-0:on 810928,train a Quench Spray Chemical Addition Pump Discharge Valve MOV-QS-104A Failed to Stroke During Valve Exercise Surveillance Test.Caused by Loss of Electrical Continuity Through Torque Switch + (16:41:48, 20 December 2024)
- PNO-II-81-093, on 811103,State of Tn Decided to Distribute Potassium Iodide to All Residences within 5 Miles of Plant, Maintaining Addl Stockpiles by Local Health Officials. Training Conducted for Drug Distributor Officials 811104 + (16:41:50, 20 December 2024)
- 05000334/LER-1981-090, Forwards LER 81-090/03L-0 + (16:41:52, 20 December 2024)
- 05000317/LER-1981-072-03, /03L-0:on 811001,discovered Low Output Signal Condition for 1-PDY-121D of RCS Loop 12 Flow Signal Characterizer.Instrument Returned to Manufacturer to Determine Cause of Failure + (16:41:54, 20 December 2024)
- 05000317/LER-1981-072, Forwards LER 81-072/03L-0 + (16:41:56, 20 December 2024)
- ML20032C521 + (16:41:58, 20 December 2024)
- 05000272/LER-1981-093-03, /03L-0:on 810930,fire Pump Fuel Pump Shaft Had Broken Rendering Fire Pump 1 Inoperable.Engine Disassembled & Gears Inspected.Fuel Pump Removed.Engine & Pump Reconnected & New Fuel Pump Installed + (16:42:00, 20 December 2024)
- 05000335/LER-1981-048-03, /03L-0:on 811012,SMR-42-1 Would Not Actuate in Negative Direction & SMI-42-11 Slightly Out of Tolerance on Indication.Caused by Slightly off-ctr Spring Mass Mechanism for SMR-42-1 & Setpoint Drift for SMI-42-11 + (16:42:02, 20 December 2024)
- ML20032C518 + (16:42:03, 20 December 2024)
- 05000272/LER-1981-093, Forwards LER 81-093/03L-0.Detailed Event Analysis Encl + (16:42:05, 20 December 2024)
- 05000335/LER-1981-048, Forwards LER 81-048/03L-0 + (16:42:08, 20 December 2024)
- ML20032C513 + (16:42:09, 20 December 2024)
- 05000324/LER-1981-101-03, /03L-0:on 811012,discovered RTGB Chart Recorder for Primary Containment Atmospheric Oxygen Analyzer 2-CAC-AT-1259-2 Showing Upscale Instrument Indication of Drywell Oxygen Concentration.Cause Not Determined + (16:42:11, 20 December 2024)
- ML20032C511 + (16:42:13, 20 December 2024)
- 05000324/LER-1981-101, Forwards LER 81-101/03L-0 + (16:42:14, 20 December 2024)
- 05000324/LER-1981-104-03, /03L-0:on 811012,during Lpci/Rhr Sys Operability test,2C RHR Pump Would Not Start.Insp Revealed Breaker Overcurrent Relay Device Tripped.Caused by Contacts Staying Closed.Relay Replaced & RHR Pump Returned to Svc + (16:42:16, 20 December 2024)
- ML20032C507 + (16:42:18, 20 December 2024)
- ML20032C506 + (16:42:19, 20 December 2024)
- 05000324/LER-1981-104, Forwards LER 81-104/03L-0 + (16:42:20, 20 December 2024)
- 05000364/LER-1981-044-03, /03L-0:on 811003,steam Jet Air Ejector Noble Gas Activity Monitor Declared Inoperable Due to Erratic Indication of Activity.Caused by Moisture in Detector Unit Caused by Improper Automatic Drain Valve Operation + (16:42:23, 20 December 2024)
- ML20032C502 + (16:42:24, 20 December 2024)
- ML20032C501 + (16:42:25, 20 December 2024)
- ML20032C500 + (16:42:26, 20 December 2024)
- 05000364/LER-1981-044, Forwards LER 81-044/03L-0 + (16:42:28, 20 December 2024)
- 05000325/LER-1981-059-03, /03L-0:on 811010,primary Containment Atmospheric Monitor Oxygen analyzer,1-CAC-AT-1263-2 Indicated Higher Oxygen Concentration than Other Monitor.On 811016,analyzer Indicated Lower Concentration.Caused by Moisture Buildup + (16:42:30, 20 December 2024)
- ML20032C496 + (16:42:35, 20 December 2024)
- 05000325/LER-1981-059, Forwards LER 81-059/03L-0 + (16:42:37, 20 December 2024)
- 05000324/LER-1981-110-03, /03L-0:on 811013,primary Containment Atmospheric Hydrogen Analyzer 2-CAC-AT-1263-1 Indicated Slight Hydrogen Concentration in Drywell.Caused by Erratic Span Potentiometer.New Potentiometer Installed + (16:42:40, 20 December 2024)
- AECM-81-435, Interim Deficiency Rept 2 Re Failure of Dikkers Safety Relief Valves,Initially Reported 810807.Solenoid Assemblies Returned to Manufacturer for Disassembly,Insp & Cleaning. Also Reportable Per Part 21 + (16:42:42, 20 December 2024)
- 05000324/LER-1981-110, Forwards LER 81-110/03L-0 + (16:42:45, 20 December 2024)
- ML20032C482 + (16:42:46, 20 December 2024)
- ML20032C476 + (16:42:48, 20 December 2024)
- ML20032C475 + (16:42:49, 20 December 2024)
- ML20032C472 + (16:42:50, 20 December 2024)
- ML20032C470 + (16:42:51, 20 December 2024)
- 05000251/LER-1981-011-01, /01T-0:on 811021,high Head Safety Injection Line to Cold Legs Found to Be Obstructed During Full Flow Test on Discharge Check Valve of Pumps.Caused by Reduced Temp Due to Missing Insulation Near 4-inch Tee at Bit Inlet + (16:42:53, 20 December 2024)
- ML20032C468 + (16:42:55, 20 December 2024)
- ML20032C466 + (16:42:57, 20 December 2024)
- 05000251/LER-1981-011, Forwards LER 81-011/01T-0 + (16:42:59, 20 December 2024)
- 05000281/LER-1981-064-03, /03L-0:on 811008,during Charging Pump Svc Water Surveillance testing,2-SW-P-10B Failed to Develop Required Discharge Pressure & Was Declared Inoperable.Caused by Loss of Npsh.Svc Water Flow Adjusted & Pump Vented + (16:43:01, 20 December 2024)
- ML20032C458 + (16:43:06, 20 December 2024)
- FVY-81-136, Responds to NRC Re Violations Noted in IE Insp Rept 50-271/81-08.Corrective Actions:Personnel Trained in Written Procedures & Exam Qualification Criteria Established + (16:43:08, 20 December 2024)
- ML20032C452 + (16:43:11, 20 December 2024)
- ML20032C448 + (16:43:14, 20 December 2024)
- 05000281/LER-1981-063-03, /03L-0:on 811014,vol of Borated Water in Safety Injection Accumulator B Exceeded Tech Spec.Caused by Personnel Error.Operator Filling Accumulator Was Slow Terminating Makeup.Vol Brought within Limits + (16:43:15, 20 December 2024)
- ML20032C445 + (16:43:28, 20 December 2024)
- ML20032C443 + (16:43:33, 20 December 2024)
- ML20032C441 + (16:43:37, 20 December 2024)