Transamenca P;;*;fc"o*%"!!"t,_

gl 550 85th Avenue s

o.O. Box 2161 mg Oakland. C%forn:a 94621 (415) 577-7400 1

i p p/ %

ep 3

s.

S f' fl[F November 5, 1981 g

L. ;4 LU -d>a A

~

t NOVO 91981 I1 u,s. texun uomou l,

Di rector, Of fice Of Inspection and Regulation amum f

U.S. Nuclear Regulatory Commission Washington, D.C. 20555 4-QfM s\\

Dear Sir:

In accordance with the requi rements of Ti tle10, Chapter 1, Code of r deral Re-e gulations, Part 21, Transamerica Delaval, Inc., herebv notifies the commission of a potential defect in a component of a DSR or DSRb standby diesel generator.

There exists a potential problem with a starting air check valve, which could result in engine non-availability.

Transamerica Delava'. has supplied the DSR and DSRV series engines with the po-tential defect to the following sites:

1)

Cleveland Electric, Perry Nuclear Station a > c /' f '

SN 75C51/54 DSRV16 at. 2 SN 77001/04 DSRV12

?)

Consumer Fower, liidland I and 2

3) Tennessee Valley Authority, Bellefone Station

't SN 75080/83 DSRV16

4) Texas Utilities, Commanche Peak I and 2 "a

SN 76001/4 DSRV16

5) Tennessee Valley Authority, Hartsville Station !:

SN 77024/31 DSRV16 Phipps Bend Station e;SN 77032/35 DSRV16 This starting air check valve is manufactured by the Wm. Powell Company, Cin-nannati, Ohio.

I t is thei r Fig. 2346 11" Chec. Valve.

This valve is furnished by Transamerica Delaval, and installed in the engine starting air system at the site by others.

The potential defect exists in the starting air system which supplies starting air for starting the standby diesel engine. This valve is installed between the starting ai r compressor, and the starting ai r storage tanks. The function of this valve :s to allow the starting air compressor to charge the storage tank, and then prevent back-flow once the tanks are charged.

During a recent seismic qualification test, one of these valves was found to leak.

A copy of this 1etter will be sent to each of the cognizant parties listed in paragraph 2.

Transamerica Delaval has been working with the Wm. Powell Compr.y 560

.5

/O 8111100519 811105 PDR ADOCK 05000329 S

PDR gg-l]

Transamerica De!avat Inc.

bbE N h Engine and Compressor Division hgl g l 550 85th Avenue P.O. Box 2161

"*"d-

' "' '" ' * * ' e 2,

El E (415) 577-7400 U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Page 2 to resolve this problem. At present, we are not prepared to recommend a cor-rective action, since we have not yet completed our investigation. We estimate our inva tigation will be completed by January 15, 1982.

Our evaluation of the defect was concluded on flovember 4,1981.

This report confirms an initial telephone report of Noverr.ber 5,1981, to Mr. R.T. Dodds, Region 5, Walnut Creek, CA.

Sincerely, Q S-w R. E. Boyer, Manager Quality Assurance REB:lc cc:

Mr. R.T. Dodds U.S. Nuclear Regulatory Commission 1990 N. California Blvd.

Walnut Creek, CA 94596

...