- ML20039C534 + (05:00:52, 20 December 2024)
- ML20039C533 + (05:00:58, 20 December 2024)
- 05000369/LER-1981-184, Forwards LER 81-184/03L-0 + (05:01:00, 20 December 2024)
- ML20039C529 + (05:01:01, 20 December 2024)
- 05000366/LER-1981-114-03, /03L-0:on 811121,B Loop of Rhr,Lpci Injection Valve 2E11-F015B,motor Breaker Tripped & Could Not Be Reset. Caused by Motor Windings Drawing Excessive Current Causing Windings to Deteriorate.Motor Replaced + (05:01:06, 20 December 2024)
- ML20039C524 + (05:01:07, 20 December 2024)
- 05000325/LER-1981-087-03, /03L-0:on 811127,primary Containment Atmospheric Monitoring Oxygen Analyzer 1-CAC-AT-1263-2,Model F3M3-1AX Was Exhibiting Downscale Indications.Caused by Sample Point Shift.Electromagnetic Unit Readjusted + (05:01:08, 20 December 2024)
- ML20039C522 + (05:01:09, 20 December 2024)
- ML20039C521 + (05:01:10, 20 December 2024)
- ML20039C520 + (05:01:11, 20 December 2024)
- 05000327/LER-1981-145-03, /03L-0:on 811118,motor Leads on 1FCV-63-6 Were Discovered Lifted During Quarterly Running of SI-166.1. Probably Caused by Mistake on Data Sheet Signoff & Failure to Reterminate Leads + (05:01:12, 20 December 2024)
- 05000366/LER-1981-114, Forwards LER 81-114/03L-0 + (05:01:16, 20 December 2024)
- ML20039C513 + (05:01:17, 20 December 2024)
- ML20039C514 + (05:01:17, 20 December 2024)
- 05000327/LER-1981-145, Forwards LER 81-145/03L-0 + (05:01:18, 20 December 2024)
- IR 05000369/1981034 + (05:01:20, 20 December 2024)
- 05000325/LER-1981-087, Forwards LER 81-087/03L-0 + (05:01:22, 20 December 2024)
- 05000249/LER-1981-037-03, /03L-0:on 811119,while Performing Diesel Generator Operability Surveillance,Diesel Generator Exhibited High Coolant Water Temp.Caused by Defective Discharge Check Valve on Diesel Generator Cooling Water Pump + (05:01:23, 20 December 2024)
- 05000366/LER-1981-117-03, /03L-0:on 811126,after Replacing LPCI Valve Motor 2E11-F015B,abnormal Phase Currents Were Traced to LPCI Inverter B (2R44-S003).Caused by Improper Operation of Gate Firing Module.Inverter Replaced + (05:01:25, 20 December 2024)
- ML20039C505 + (05:01:26, 20 December 2024)
- ML20039C503 + (05:01:27, 20 December 2024)
- ML20039C501 + (05:01:28, 20 December 2024)
- GO2-81-051, Interim Deficiency Rept Re Load Capacity Data Sheets, Initially Reported 810630.Std Components Will Be Evaluated During Design Verification.Next Rept Will Be Submitted by 820211 + (05:01:29, 20 December 2024)
- ML20039C499 + (05:01:30, 20 December 2024)
- 05000366/LER-1981-117, Forwards LER 81-117/03L-0 + (05:01:32, 20 December 2024)
- 05000249/LER-1981-037, Forwards LER 81-037/03L-0 + (05:01:33, 20 December 2024)
- ML20039C494 + (05:01:35, 20 December 2024)
- ML20039C493 + (05:01:35, 20 December 2024)
- 05000325/LER-1981-086-03, /03L-0:on 811125,during Routine Surveillance Discovered Primary Containment Atmospheric Monitor Oxygen Analyzer 1-CAC-AT-1259-2,Model F3M3 Tripped.Caused by Condensation.Analyzer Sample Lines Blown Down + (05:01:37, 20 December 2024)
- ML20039C490 + (05:01:38, 20 December 2024)
- ML20039C489 + (05:01:39, 20 December 2024)
- 05000325/LER-1981-086, Forwards LER 81-086/03L-0 + (05:01:41, 20 December 2024)
- ML20039C484 + (05:01:43, 20 December 2024)
- 05000338/LER-1981-079-03, /03L-0:on 811201,while Operating in Mode 1 at 100% Power,Emergency Diesel Generator 1J Was Declared Inoperable. Caused by Specific Gravity of One Battery Cell Falling Below Tech Spec.Cell Replaced + (05:01:44, 20 December 2024)
- 05000325/LER-1981-088-03, /03L-0:on 811124 & 1204,automatic Isolating Function of C TIP Machine Primary Containment Isolation Ball Valve Became Inoperable.Caused First by High Ambient Humidity Due to Steam Leak & Second by Replacement of Valve + (05:01:49, 20 December 2024)
- 05000338/LER-1981-079, Forwards LER 81-079/03L-0 + (05:01:51, 20 December 2024)
- ML20039C479 + (05:01:52, 20 December 2024)
- ML20039C478 + (05:01:53, 20 December 2024)
- 05000325/LER-1981-088, Forwards LER 81-088/03L-0 + (05:01:55, 20 December 2024)
- 05000338/LER-1981-083-03, /03L-0:on 811202,svc Water Supply Header B to Charging Pumps Was Isolated to Repair Pinhole Leak in Line.Caused by Aggressive Water & Bacterial Reduction of Mild Steel Piping.Section of Piping Replaced + (05:01:56, 20 December 2024)
- ML20039C474 + (05:01:57, 20 December 2024)
- 05000321/LER-1981-125-03, /03L-0:on 811123,leakage Rate on Drywell Personnel Airlock Innerspace Exceeded Tech Specs.Caused by Leaking Inner & Outer Door Seals & O Ring Seal on Inside Shaft of Inner Door.Seals Replaced & Ring Seal Tightened + (05:01:59, 20 December 2024)
- ML20039C472 + (05:02:00, 20 December 2024)
- W3P81-2843, Provides Fourth Monthly Rept Re Recruiting & Upgrading of Total Corporate Capability,Per 810806 Meeting W/Acrs.Status of Staffing Commitments Made 810420 & Organization Charts Encl + (05:02:01, 20 December 2024)
- 05000338/LER-1981-083, Forwards LER 81-083/03L-0 + (05:02:03, 20 December 2024)
- 05000321/LER-1981-125, Forwards LER 81-125/03L-0 + (05:02:05, 20 December 2024)
- ML20039C466 + (05:02:07, 20 December 2024)
- ML20039C465 + (05:02:07, 20 December 2024)
- ML20039C464 + (05:02:08, 20 December 2024)
- ML20039C462 + (05:02:09, 20 December 2024)
- ML20039C461 + (05:02:10, 20 December 2024)