- ML19294A484 + (13:39:57, 2 January 2025)
- ML19294A481 + (13:39:58, 2 January 2025)
- ML19294A480 + (13:39:59, 2 January 2025)
- ML19294A479 + (13:40:01, 2 January 2025)
- ML19294A477 + (13:40:02, 2 January 2025)
- ML19294A476 + (13:40:03, 2 January 2025)
- 05000348/LER-1978-076-03, /03L-0;on 781011,during Operational check,1B Diesel Generator Was Started.B Air Start Sloenoid Valve Stuck Open,Bleeding B Air Receiver Down to 10psig.Valve Disassembled & Parts Cleaned.Unit re-tested + (13:40:04, 2 January 2025)
- 05000348/LER-1978-075-03, /03L-0:on 781010,review of Data Acquired During Response Time Testing Indicated Possible Faulty Component in 1-2A D/G Output Breaker Control Circuit,Causing Delay in Closure.Fuse on 125 V DC Supply Was Blown.Fuse Replaced + (13:40:07, 2 January 2025)
- 05000348/LER-1978-074-03, /03L-0:on 780917,during test,1A Motor Driven Aux Feed Pump Failed to auto-start Due to B1F Sequencer Failure. Caused by 205F Agastat Relay Time Delay Setpoint Which Had Drifted.Setpoint Was Adjusted & Retest Performed + (13:40:09, 2 January 2025)
- 05000348/LER-1978-073-03, /03L-0 on 781009:Instru Air to Containment Iso Valve Was Declared Inoper When Valve Was Blocked Open to Allow Repair of Control Air Supply Regulator Valve Actuator. Regulator Replaced & Valve Stem Reconnected + (13:40:11, 2 January 2025)
- 05000348/LER-1978-073, Forwards LER 78-073/03L-0,78-074/03L-0,78-075/03L-0, 78-076/03L & 78-077/03L-0 + (13:40:13, 2 January 2025)
- ML19294A467 + (13:40:15, 2 January 2025)
- ML19294A469 + (13:40:15, 2 January 2025)
- ML19294A462 + (13:40:17, 2 January 2025)
- ML19294A461 + (13:40:18, 2 January 2025)
- ML19294A460 + (13:40:19, 2 January 2025)
- ML19294A459 + (13:40:20, 2 January 2025)
- ML19294A457 + (13:40:23, 2 January 2025)
- IR 05000348/1978024 + (13:40:25, 2 January 2025)
- ML19294A455 + (13:40:29, 2 January 2025)
- ML19294A451 + (13:40:31, 2 January 2025)
- ML19294A453 + (13:40:31, 2 January 2025)
- ML19294A446 + (13:40:33, 2 January 2025)
- ML19294A450 + (13:40:33, 2 January 2025)
- 05000334/LER-1978-054-03, /03L-0 on 781005:During Surveillance Test on Containment High Pressure Bistable,The Setpoint Was 2.3 Lbs Instead of 2.0.Caused by Faulty Elco Connector on Loop Signal Comparator.Comparator Was Replaced + (13:40:35, 2 January 2025)
- 05000334/LER-1978-054, Forwards LER 78-054/03L-0 + (13:40:40, 2 January 2025)
- ML19294A441 + (13:40:41, 2 January 2025)
- 05000318/LER-1978-034-03, /03L-0 on 781023: in Mode 3 at 500F,12 Main Steam Safety Valve Relief Set Points Were Outside Tolerances of TS 4.7.1;all Were Adjusted & Setpoints Returned to Spec + (13:40:43, 2 January 2025)
- ML19294A439 + (13:40:45, 2 January 2025)
- 05000318/LER-1978-034, Forwards LER 78-034/03L-0 + (13:40:46, 2 January 2025)
- ML19294A435 + (13:40:48, 2 January 2025)
- ML19294A434 + (13:40:51, 2 January 2025)
- ML19294A432 + (13:40:52, 2 January 2025)
- ML19294A430 + (13:40:57, 2 January 2025)
- ML19294A429 + (13:40:57, 2 January 2025)
- ML19294A428 + (13:40:58, 2 January 2025)
- ML19294A427 + (13:40:59, 2 January 2025)
- ML19294A424 + (13:41:00, 2 January 2025)
- ML19294A426 + (13:41:00, 2 January 2025)
- ML19294A422 + (13:41:01, 2 January 2025)
- ML19294A415 + (13:41:02, 2 January 2025)
- ML19294A418 + (13:41:02, 2 January 2025)
- ML19294A409 + (13:41:04, 2 January 2025)
- ML19294A413 + (13:41:04, 2 January 2025)
- ML19294A408 + (13:41:07, 2 January 2025)
- ML19294A406 + (13:41:09, 2 January 2025)
- ML19294A404 + (13:41:10, 2 January 2025)
- ML19294A403 + (13:41:11, 2 January 2025)
- ML19294A402 + (13:41:12, 2 January 2025)
- ML19294A401 + (13:41:13, 2 January 2025)
- ML19294A400 + (13:41:15, 2 January 2025)