Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19305B833 + (11:04:14, 2 January 2025)
- IR 05000454/1980001 + (11:04:16, 2 January 2025)
- 05000301/LER-1980-002-01, /01T-0:on 800227,primary-to-secondary Leak Was Identified in Steam Generator a Resulting in Shutdown of Unit.Caused by Leaking Tube at Position R18C37.Six Defective Tubes Found in Steam Generator a + (11:04:18, 2 January 2025)
- 05000304/LER-1980-008-03, /03L-0:on 800206,w/unit at 95% Power,Instrument Loop for Steam Generator Pressure Indication Was Being Functionally Tested.Pressure Transmitter 2PT526 Was 2.5% Out of Tolerance.Caused by Previous Freezing + (11:04:21, 2 January 2025)
- 05000304/LER-1980-008, Forwards LER 80-008/03L-0 + (11:04:23, 2 January 2025)
- 05000295/LER-1980-009-03, /03L-0:800212,w/Unit 1 in Constant Speed Drive & Unit 2 at 99% Power,Control Room Monitor Began High Alarming W/Insufficient Meter Reading to Trip Alarm.Caused by Defective Detector Tube & Faulty Connection on Meter Pin + (11:04:25, 2 January 2025)
- ML19305B823 + (11:04:26, 2 January 2025)
- 05000265/LER-1980-004-03, /03L-0:on 800219,while Performing Procedure Qms 700-1,automatic Blowdown Timer 287-105A Took 122-s to Time Out,Exceeding Tech Spec Limit.Caused by Instrument Setpoint Drift.Timer Adjusted & Verified to Be 100-s + (11:04:27, 2 January 2025)
- ML19305B821 + (11:04:29, 2 January 2025)
- 05000265/LER-1980-004, Forwards LER 80-004/03L-0 + (11:04:30, 2 January 2025)
- 05000295/LER-1980-009, Forwards LER 80-009/03L-0 + (11:04:32, 2 January 2025)
- 05000254/LER-1980-003-03, /03L-0:on 800206,while Performing Procedure Qos 1000-3,RHR to Suppression Chamber Dump Valve,Mo 1-1001- 36A,circuit Breaker Tripped Out.Caused by Burned Out 480/120-volt Transformer in Circuit Breaker Cabinet + (11:04:34, 2 January 2025)
- ML19305B815 + (11:04:35, 2 January 2025)
- IR 05000010/1980002 + (11:04:36, 2 January 2025)
- 05000304/LER-1980-010-03, /03L-0:on 800202,during Surveillance of Containment Vent Particulate Rad Monitor 2 RE-0011,no Grab Sample Was Drawn for Second Shift.Caused by Misunderstanding Between Operating & Radiation Protection Personnel + (11:04:38, 2 January 2025)
- 05000254/LER-1980-003, Forwards LER 80-003/03L-0 + (11:04:40, 2 January 2025)
- ML19305B807 + (11:04:41, 2 January 2025)
- 05000265/LER-1980-003-03, /03L-0:on 800213,while Performing Procedure Qis 35-2,reactor Bldg Ventilation Sys Would Not Reset After Test Isolation.Caused by Burnt CR 120 Relay.Relay 1705-105 Replaced & Functional Test Sucessfully Completed + (11:04:42, 2 January 2025)
- IR 05000237/2019003 + (11:04:53, 2 January 2025)
- ML19305B803 + (11:04:55, 2 January 2025)
- ML19305B802 + (11:04:56, 2 January 2025)
- 05000304/LER-1980-010, Forwards LER 80-010/03L-0 + (11:04:57, 2 January 2025)
- ML19305B798 + (11:04:58, 2 January 2025)
- 05000265/LER-1980-003, Forwards LER 80-003/03L-0 + (11:05:00, 2 January 2025)
- ML19305B795 + (11:05:01, 2 January 2025)
- ML19305B794 + (11:05:02, 2 January 2025)
- ML19305B793 + (11:05:03, 2 January 2025)
- 05000304/LER-1980-011-03, /03L-0:on 800224,while Operating at 95% Power, Monthly Surveillance Requiring Performance Testing of MSIV Was Performed Two Days Late.Caused by Incorrect Date Recorded on Schedule.Testing Performed + (11:05:04, 2 January 2025)
- 05000304/LER-1980-011, Forwards LER 80-011/03L-0 + (11:05:06, 2 January 2025)
- 05000254/LER-1979-040, Supplemental LER 79-040/03L-1:on 791213,during Instrument Check,Variations in Suppression Pool Level Noted Between Reading on Control Room Panel 901-3 & Local Sight Glass, Exceeding Tech Specs.Caused by Crud on Sensing Lines + (11:05:08, 2 January 2025)
- ML19305B786 + (11:05:10, 2 January 2025)
- ML19305B785 + (11:05:10, 2 January 2025)
- ML19305B784 + (11:05:11, 2 January 2025)
- ML19305B783 + (11:05:12, 2 January 2025)
- ML19305B782 + (11:05:13, 2 January 2025)
- ML19305B781 + (11:05:13, 2 January 2025)
- ML19305B778 + (11:05:14, 2 January 2025)
- ML19305B780 + (11:05:14, 2 January 2025)
- ML19305B777 + (11:05:15, 2 January 2025)
- ML19305B776 + (11:05:16, 2 January 2025)
- ML19305B775 + (11:05:17, 2 January 2025)
- ML19305B773 + (11:05:18, 2 January 2025)
- ML19305B774 + (11:05:18, 2 January 2025)
- ML19305B771 + (11:05:19, 2 January 2025)
- ML19305B770 + (11:05:20, 2 January 2025)
- ML19305B769 + (11:05:21, 2 January 2025)
- ML19305B768 + (11:05:22, 2 January 2025)
- ML19305B767 + (11:05:23, 2 January 2025)
- ML19305B766 + (11:05:24, 2 January 2025)
- ML19305B765 + (11:05:25, 2 January 2025)
- ML19305B764 + (11:05:26, 2 January 2025)