- ML20063B862 + (03:10:07, 17 December 2024)
- 05000318/LER-1982-036-03, /03L-0:on 820719,during Normal Operation, Containment Particulate Radiation Monitor Observed Reading Below Tech Spec Limit.Caused by Signal Pin Detached from Field Cable Connector DSOF-12P-059 at Instrument Drawer + (03:10:08, 17 December 2024)
- ML20063B853 + (03:10:13, 17 December 2024)
- 05000346/LER-1993-009, :on 931221,CREVS Train 2 Declared Inoperable & TS 3.0.3 Entered Due to Excessive Bearing Noise.Train 2 Fan Bearing & Train 1 Refrigerant Pressure Sensing Line Which Developed Leak on 931222 Repaired + (03:10:14, 17 December 2024)
- 05000318/LER-1982-036, Forwards LER 82-036/03L-0 + (03:10:15, 17 December 2024)
- 05000265/LER-1993-026-01, :on 931224,reactor Scram Discovered Due to Sudden Pressure Release from 2-220-1118 a Valve.Caused by Lack of Verification of 118A Valve Position & Inadequate pre-job Briefings.Procedures Revised + (03:10:17, 17 December 2024)
- ML20063B838 + (03:10:19, 17 December 2024)
- 05000352/LER-1993-018, :on 931206,emergency Diesel Generator Fuel Oil Samples Not Analyzed within TS Specified Period.Caused by Inadequate Process.Corrective Actions Expected to Be Completed by 940429.Packages to Be Labeled + (03:10:23, 17 December 2024)
- 05000317/LER-1982-042, Forwards LER 82-042/03L-0 + (03:10:24, 17 December 2024)
- ML20063B823 + (03:10:25, 17 December 2024)
- ML20063B819 + (03:10:27, 17 December 2024)
- ML20063B814 + (03:10:28, 17 December 2024)
- ML20063B810 + (03:10:32, 17 December 2024)
- 05000333/LER-1982-037-03, /03L-0:on 820730,during Ascension to Power, Abnormally High Tail Piece Temps Indicated on Interim Target Rock Model Safety Relief Valve F.Probably Caused by Valve Leakage from Pilot Seat.Daily Surveillance Initiated + (03:10:34, 17 December 2024)
- ML20063B804 + (03:10:35, 17 December 2024)
- ML20063B795 + (03:10:36, 17 December 2024)
- 05000333/LER-1982-037, Forwards LER 82-037/03L-0 + (03:10:37, 17 December 2024)
- ML20063B793 + (03:10:37, 17 December 2024)
- ML20063B792 + (03:10:38, 17 December 2024)
- ML20063B789 + (03:10:39, 17 December 2024)
- ML20063B787 + (03:10:40, 17 December 2024)
- 05000334/LER-1982-030-03, /03L-0:on 820805,while Performing Ost 1.12.1, Containment Vacuum Pump 1A Failed to Start.Caused by Corrosion on Sliding Vanes & Pump Casting.Pump Replaced + (03:10:42, 17 December 2024)
- ML20063B783 + (03:10:43, 17 December 2024)
- ML20063B779 + (03:10:44, 17 December 2024)
- 05000219/LER-1982-042-03, /03L-0:on 820716,during Surveillance Testing, Relay 16K118 & 15K14B Timers Failed,Preventing Automatic Actuation of Containment Spray Sys Ii.Caused by Instrument Drift.Relays Replaced & Tested + (03:10:45, 17 December 2024)
- ML20063B771 + (03:10:46, 17 December 2024)
- 05000334/LER-1982-030, Forwards LER 82-030/03L-0 + (03:10:47, 17 December 2024)
- ML20063B767 + (03:10:47, 17 December 2024)
- NRC-94-4049, Forwards Nonproprietary WCAP-13914 & Proprietary WCAP-13913, Framework for AP600 Severe Accident Mgt Guidance. Proprietary WCAP-13913 Withheld.Also See 9809300071 + (03:10:48, 17 December 2024)
- 05000219/LER-1982-042, Forwards LER 82-042/03L-0.Detailed Event Analysis Encl + (03:10:49, 17 December 2024)
- 05000277/LER-1993-016-01, :on 931221,HPCIS Declared Inoperable During Performance of Surveillance Test.Cause Not Yet Determined. Instument Caibration Line Flushed to Clear Blockage & Back Filled.Procedures Revised + (03:10:50, 17 December 2024)
- 05000333/LER-1982-036-03, /03L-0:on 820723,offgas Radiation Monitor B Observed Spiking in Upward Direction.Caused by Failure of Zener Diode within Plus/Minus 15-volt Power Supply.Entire Unit Replaced W/Spare & Calibr + (03:10:55, 17 December 2024)
- ML20063B754 + (03:10:57, 17 December 2024)
- ML20063B755 + (03:10:57, 17 December 2024)
- ML20063B751 + (03:10:58, 17 December 2024)
- NRC-94-4046, Forwards Meeting Agenda & Nonproprietary & Proprietary Presentation Matls from 940120 & 21 Meeting W/Nrc in Rockville,Md to Discuss AP600 Seismic & Structural Issues. Proprietary Presentation Matl Withheld + (03:10:58, 17 December 2024)
- ML20063B745 + (03:10:59, 17 December 2024)
- ML20063B743 + (03:11:00, 17 December 2024)
- ST-HL-AE-4666, Application for Amends to Licenses NPF-76 & NPF-80,adding New TS Allowing Restart of Unit 2 W/Expired Calibrations on Core Exit Thermocouples + (03:11:00, 17 December 2024)
- 05000339/LER-1994-001, :on 940105,steam Driven Afp 2-FW-P-2 Inlet Trip Valve Closed When Manual Trip Level Accidentally Actuated Rendering Pump Inoperable.Caused by Personnel Error.Maint Engineer Counseled on Proper Work Practices + (03:11:02, 17 December 2024)
- 05000333/LER-1982-038-03, /03L-0:on 820801,MSIV a Inboard 10% Switch Did Not Trip When Tested to Satisfy Tech Spec 3.1-1,Note 1.Caused by Drift Between Switch Operator & Striker Plate.Position Switch Will Be Investigated During Maint Outage + (03:11:04, 17 December 2024)
- 05000333/LER-1982-036, Forwards LER 82-036/03L-0 + (03:11:05, 17 December 2024)
- 3F0194-10, Responds to Violation Noted in Insp Rept 50-302/93-18. Corrective Actions for Violation 93-18-01 Will Be Delayed Until 940401 for Rev to Surveillance Procedure SP-523 + (03:11:06, 17 December 2024)
- ML20063B724 + (03:11:10, 17 December 2024)
- ML20063B722 + (03:11:11, 17 December 2024)
- NRC-94-4050, Forwards Nonproprietary & Proprietary Presentation Matls from 940125 Meeting W/Nrc in Rockville,Md to Discuss AP600 Automatic Depressurization Sys Test Plans Supporting AP600 Design Certification Program.Proprietary Matl Withheld + (03:11:12, 17 December 2024)
- 05000374/LER-1993-010-06, :on 931225,discovered That Rcics Inoperable. Caused by Loss of Power from Malfunctioning Tracking Control Relay.Rcics re-started Per LOS-RI-05 & Declared Operable + (03:11:13, 17 December 2024)
- 05000374/LER-1993-009-06, :on 931224,RWC High Differential Isolation Occurred.Caused by Filter/Demineralizer on Line Not at Rated Conditions.Procedures Revised + (03:11:15, 17 December 2024)
- 05000333/LER-1982-038, Forwards LER 82-038/03L-0 + (03:11:16, 17 December 2024)
- ML20063B696 + (03:11:23, 17 December 2024)
- ML20063B690 + (03:11:24, 17 December 2024)
- 05000311/LER-1982-069-03, /03L-0:on 820724,control Operator Observed Erratic Operation of Reactor Coolant Pump 23 Flow Channel Iii.Caused by Flow Transmitter Ferrite Slug Failure.Failed Transmitter Replaced & Channel Recalibr + (03:11:26, 17 December 2024)