Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20064E743 + (01:55:28, 17 December 2024)
- ML20064E745 + (01:55:28, 17 December 2024)
- ML20064E739 + (01:55:33, 17 December 2024)
- ML20064E727 + (01:55:35, 17 December 2024)
- 05000348/LER-1978-078-03, /03L-0 on 781016:the a Train Undervoltage Relay 27-1 on RCP 1A Failed to Trip at Required Setpoint During Test Procedure FNP-1-612.0 Due to Setpoint Drift + (01:55:37, 17 December 2024)
- ML20064E722 + (01:55:38, 17 December 2024)
- 05000348/LER-1978-078, Forwards LER 78-078/03L-0 + (01:55:39, 17 December 2024)
- ML20064E715 + (01:55:40, 17 December 2024)
- ML20064E717 + (01:55:40, 17 December 2024)
- 05000219/LER-1978-023-03, /03L-0 on 781019:IRM 12 Became Inoperative While Cable to IRM 14 Was Disconnected.Irm 12 Failure Attributed to Maint Activities Under Vessel.Subesquent Inspec Showed IRM 12 Cable Damaged + (01:55:42, 17 December 2024)
- ML20064E706 + (01:55:42, 17 December 2024)
- 05000219/LER-1978-023, Forwards LER 78-023/03L-0 + (01:55:44, 17 December 2024)
- ML20064E697 + (01:55:45, 17 December 2024)
- ML20064E692 + (01:55:45, 17 December 2024)
- 05000338/LER-1978-118, Forwards LER 78-118/99T-0 + (01:55:47, 17 December 2024)
- 05000317/LER-1982-069-03, /03L-0:on 821129,during Surveillance Testing, Auxiliary Feedwater Pump Turbine 11 Journal Bearing Temp Rapidly Increased to 214 F.Caused by Improperly Marked Oil Level Gauge Glass Allowing Low Oil Level.Gauge Remarked + (01:55:49, 17 December 2024)
- ML20064E688 + (01:55:50, 17 December 2024)
- ML20064E685 + (01:55:50, 17 December 2024)
- ML20064E680 + (01:55:54, 17 December 2024)
- 05000338/LER-1978-112-03, /03L-0 on 781025:During Routine Startup Oper,Axial Flux Difference Deviated Greater than 5% from target.48 Penalty Min Accumulated.Caused by Xenon Transient Occurrence.Corrective Action:Boration by Reactor Operator + (01:55:55, 17 December 2024)
- 05000338/LER-1978-112, Forwards LER 78-112/03L-0 + (01:55:57, 17 December 2024)
- 05000317/LER-1982-069, Forwards LER 82-069/03L-0 + (01:55:58, 17 December 2024)
- ML20064E668 + (01:55:59, 17 December 2024)
- 05000336/LER-1978-027-03, /03L-0 on 781024:plant Computer Malfunction Caused CEA Pulse Counting Position to Be in Oper.Cause of Computer Failure Could Not Be Traced + (01:56:00, 17 December 2024)
- BSEP-94-0093, Monthly Operating Repts for Feb 1994 for Brunswick Nuclear Plant Units 1 & 2 + (01:56:01, 17 December 2024)
- 05000336/LER-1978-027, Forwards LER 78-27/03L-0 + (01:56:02, 17 December 2024)
- ML20064E654 + (01:56:03, 17 December 2024)
- ML20064E651 + (01:56:04, 17 December 2024)
- ML20064E653 + (01:56:04, 17 December 2024)
- 05000317/LER-1982-074-03, /03L-0:on 821127,during Normal Operation,Water Leak Discovered from Cracked Weld on Charging Pump 11 Discharge Drain Line.Caused by Thin Crack in Heat Affected Zone of Socket Weld Due to Vibration.Weld Repaired + (01:56:06, 17 December 2024)
- ML20064E646 + (01:56:07, 17 December 2024)
- ML20064E644 + (01:56:08, 17 December 2024)
- ML20064E642 + (01:56:08, 17 December 2024)
- 05000317/LER-1982-074, Forwards LER 82-074/03L-0 + (01:56:09, 17 December 2024)
- ML20064E639 + (01:56:09, 17 December 2024)
- ML20064E633 + (01:56:10, 17 December 2024)
- ML20064E635 + (01:56:10, 17 December 2024)
- ML20064E628 + (01:56:14, 17 December 2024)
- ML20064E627 + (01:56:15, 17 December 2024)
- ML20064E624 + (01:56:15, 17 December 2024)
- ML20064E622 + (01:56:16, 17 December 2024)
- ML20064E620 + (01:56:17, 17 December 2024)
- ML20064E618 + (01:56:18, 17 December 2024)
- ML20064E617 + (01:56:18, 17 December 2024)
- LIC-94-0053, Responds to NRC Re Violations Noted in Insp Rept 50-285/93-26.Corrective Actions:Rca Was Performed,Field Design Change Requested & Const Work Order Generated to Modify EHC Sys Tubing + (01:56:20, 17 December 2024)
- ML20064E615 + (01:56:20, 17 December 2024)
- ML20064E613 + (01:56:21, 17 December 2024)
- ML20064E612 + (01:56:21, 17 December 2024)
- 05000416/LER-1993-018, :on 931213,RCIC Steam Supply Isolation Occurred Due to Invalid Temp Signal.Caused by Failure of Equipment Room Differential Temp Switch.Faulty Switch Replaced.W/ + (01:56:23, 17 December 2024)
- 05000277/LER-1982-041-01, /01T-0:on 821210,reactor Water Cleanup High Temp Isolation Signal Bypassed After Trip.Caused by False Initiation Signal Due to Short Circuit in Temp Switch Caused by Frayed Wire + (01:56:25, 17 December 2024)
- ML20064E607 + (01:56:26, 17 December 2024)