- ML20065D245 + (00:57:22, 17 December 2024)
- ML20065D239 + (00:57:23, 17 December 2024)
- ML20065D209 + (00:57:28, 17 December 2024)
- 05000277/LER-1982-017-03, /03L-0:on 820825,diesel Overspeed Trip Alarm Sounded.Caused by Shorted Overspeed Trip Switch Due to Water Entering Switch Via Cracked Switch Housing.Switch & Valve Replaced + (00:57:29, 17 December 2024)
- ML20065D201 + (00:57:30, 17 December 2024)
- ML20065D193 + (00:57:33, 17 December 2024)
- ML20065D197 + (00:57:33, 17 December 2024)
- ML20065D191 + (00:57:34, 17 December 2024)
- 05000261/LER-1982-011-03, /03L-0:on 820811,double Disc Gate Valve SI-861A Failed to Open Fully During Startup.Caused by Deformation of Valve Disc Due to Disc Interspace Overpressurization Resulting from Sys Heatup.Valve Discs Replaced + (00:57:36, 17 December 2024)
- ML20065D189 + (00:57:37, 17 December 2024)
- 05000261/LER-1982-011, Forwards LER 82-011/03L-0 + (00:57:38, 17 December 2024)
- ML20065D167 + (00:57:39, 17 December 2024)
- ML20065D176 + (00:57:39, 17 December 2024)
- ML20065D166 + (00:57:41, 17 December 2024)
- 05000346/LER-1982-038-03, /03L-0:on 820814,3/4-inch Anchor Bolt on Diesel Generator Day Tank 1-1 Saddle Type Supports Found Defective. Caused by Original Const Error.New Bolt Installed.Remaining Bolts Checked + (00:57:45, 17 December 2024)
- ML20065D157 + (00:57:47, 17 December 2024)
- ML20065D149 + (00:57:48, 17 December 2024)
- ML20065D156 + (00:57:48, 17 December 2024)
- 05000271/LER-1982-018-03, /03L-0:on 820816,following Return of Reactor Cleanup Sys to svc,CU-18 Breaker Tripped Losing Valve Position Indication.Caused by Failure of CU-18 Torque Switch.Motor,Torque Switch & Circuit Breaker Replaced + (00:57:50, 17 December 2024)
- 05000346/LER-1982-038, Forwards LER 82-038/03L-0 + (00:57:51, 17 December 2024)
- ML20065D137 + (00:57:52, 17 December 2024)
- ML20065D136 + (00:57:52, 17 December 2024)
- 05000331/LER-1982-055-03, /03L-0:on 820819,torus a Water Level Recorder, LR-4384,indicated Reduced Level While B Recorder LR-4385 Did Not Change.Caused by Associated Level Transmitter LI-4363 Being Out of Calibr.Other Causes Being Investigated + (00:57:54, 17 December 2024)
- ML20065D126 + (00:57:56, 17 December 2024)
- ML20065D128 + (00:57:56, 17 December 2024)
- 05000271/LER-1982-018, Forwards LER 82-018/03L-0 + (00:57:57, 17 December 2024)
- 05000331/LER-1982-055, Forwards LER 82-055/03L-0 + (00:57:58, 17 December 2024)
- 05000395/LER-1982-002-03, /03L-0:on 820818,after Calibr Pressure Transmitter for RHR Train a Suction Isolation Valve,Valve Operator re-energized & Suction Isolation Valve Shut.Caused by Switch Being Left in Test Position.Personnel Reinstructed + (00:58:00, 17 December 2024)
- 05000395/LER-1982-002, Forwards LER 82-002/03L-0 + (00:58:01, 17 December 2024)
- ML20065D102 + (00:58:01, 17 December 2024)
- ML20065D082 + (00:58:06, 17 December 2024)
- 05000315/LER-1982-074-03, /03L-0:on 820816,during Refueling,Source Range Neutron Flux Monitor Audible Indication in Containment Could Not Be Distinguished to Provide Meaningful Indication of Count Rate Signal.Caused by Audio Multiplier Set Too High + (00:58:07, 17 December 2024)
- ML20065D070 + (00:58:08, 17 December 2024)
- 05000346/LER-1982-039, Forwards LER 82-039/03L-0 + (00:58:10, 17 December 2024)
- ML20065D065 + (00:58:10, 17 December 2024)
- ML20065D054 + (00:58:11, 17 December 2024)
- 05000315/LER-1982-074, Forwards LER 82-074/03L-0 + (00:58:12, 17 December 2024)
- ML20065D051 + (00:58:12, 17 December 2024)
- ML20065D050 + (00:58:13, 17 December 2024)
- ML20065D049 + (00:58:13, 17 December 2024)
- ML20065D047 + (00:58:14, 17 December 2024)
- ML20065D044 + (00:58:15, 17 December 2024)
- ML20065D043 + (00:58:16, 17 December 2024)
- ML20065D039 + (00:58:16, 17 December 2024)
- ML20065D034 + (00:58:17, 17 December 2024)
- ML20065D032 + (00:58:17, 17 December 2024)
- ML20065D027 + (00:58:18, 17 December 2024)
- 2CAN039403, Advises That Util Modified Commitment to Have Safety Injection Actuation Signal Applied to SG Blowdown Sample Valves 2CV-5852-2 & 2CV-5859-2,per NRC Bulletin 79-06B + (00:58:19, 17 December 2024)
- ML20065D026 + (00:58:19, 17 December 2024)
- TAC:M77736 + (00:58:20, 17 December 2024)
- ML20065D022 + (00:58:20, 17 December 2024)