- 05000325/LER-1982-103, Forwards LER 82-103/03L-0 + (00:16:32, 17 December 2024)
- ML20065P803 + (00:16:32, 17 December 2024)
- JAFP-82-0853, Suppls Response to NRC 820120 & 0702 Ltrs Re Items Noted in IE Health Physics Appraisal Rept 50-333/80-20.Corrective Actions:Schedule for Technician Retraining Established & Engineering Controls Will Be Part of ALARA Program + (00:16:33, 17 December 2024)
- ML20065P784 + (00:16:34, 17 December 2024)
- ML20065P781 + (00:16:37, 17 December 2024)
- ML20065P779 + (00:16:38, 17 December 2024)
- BSEP-90-0811, Monthly Operating Rept for Nov 1990 for Brunswick Units 1 & 2 + (00:16:39, 17 December 2024)
- ML20065P763 + (00:16:39, 17 December 2024)
- ML20065P761 + (00:16:40, 17 December 2024)
- ML20065P760 + (00:16:41, 17 December 2024)
- ML20065P759 + (00:16:41, 17 December 2024)
- B14393, Application for Amend to License DPR-65,revising TS to Modify Indicated Measurement Range for Neutron Flux Monitor on Remote Shutdown Panel & Correct Typos & Administrative Errors + (00:16:42, 17 December 2024)
- ML20065P746 + (00:16:42, 17 December 2024)
- ML20065P739 + (00:16:47, 17 December 2024)
- ML20065P735 + (00:16:47, 17 December 2024)
- JAFP-82-1106, Ro:On 820628,combustion in Offgas Sys Observed.Caused by Improper Valve Lineup Allowing More Gas to Recombiner than Dilution Flow Rate Could Support.Incident Discussed W/Shift Supervisor & Training Will Be Developed + (00:16:48, 17 December 2024)
- ML20065P724 + (00:16:49, 17 December 2024)
- ML20065P730 + (00:16:49, 17 December 2024)
- ML20065P723 + (00:16:50, 17 December 2024)
- ML20065P719 + (00:16:50, 17 December 2024)
- 05000373/LER-1982-105-03, /03L-0:on 820920,during LOS-PC-01,valve 1833-F020, Reactor Water Sample Outboard Isolation Valve,Closed Outside Tech Spec Limit.Caused by Spring Tension Not Great Enough to Close Valve.Valve Spring Tightened + (00:16:52, 17 December 2024)
- 05000373/LER-1982-105, Forwards LER 82-105/03L-0 + (00:17:00, 17 December 2024)
- LIC-90-0941, Confirms That Response Re Implementation of Automatic Steam Generator Overfill Protection Sys Extended + (00:17:00, 17 December 2024)
- BSEP-82-2259, Ro:While Performing Insp of Fire Dampers Per 820518 Commitment,Discovered Ventilation Duct Located at Penetration Seal DG-2-034 on 23-ft Elevation of Diesel Generator Bldg Did Not Have Insp Door + (00:17:01, 17 December 2024)
- 05000338/LER-1982-063-03, /03L-0:on 820924,ambient Temp Signal Conditioner & Control Room Delta Temp Recorder Responses Found to Exceed Calibr Procedure Acceptance Criteria.Caused by Instrument Drift.Instruments Recalibr + (00:17:06, 17 December 2024)
- 05000338/LER-1982-063, Forwards LER 82-063/03L-0 + (00:17:07, 17 December 2024)
- ML20065P699 + (00:17:08, 17 December 2024)
- 05000285/LER-1950-285, Documents Deletion of Licensing Basis Commitment in LER 50-285/77-5 Re Failure of Reactor Protective Sys Trip Unit to Trip Prescribed Setpoint,Due to Improper Pretrip & Trip Indication Bulbs in Trip Unit Circuitry + (00:17:09, 17 December 2024)
- RBG-13-570, Interim Deficiency Rept DR-75 Re Error Found in Ghosh Computer Program Used in Reactor Bldg Hydrodynamic Analysis. Initially Reported on 820921.Investigation to Determine Significance of Error Continuing.Next Rept by 830114 + (00:17:09, 17 December 2024)
- SNRC-1775, Responds to Suppl 3 to Generic Ltr 89-10 Re Results of NRC- Sponsored Tests of motor-operated Valves + (00:17:10, 17 December 2024)
- ML20065P693 + (00:17:11, 17 December 2024)
- ML20065P694 + (00:17:11, 17 December 2024)
- ML20065P688 + (00:17:12, 17 December 2024)
- ML20065P690 + (00:17:12, 17 December 2024)
- PLA-1150, Responds to 820604 Systematic Assessment of Licensee Performance.Items Discussed Include Licensed Operators, Health Physics & Chemistry Staffs,Operating Procedures, Punch List Status & Open Items + (00:17:13, 17 December 2024)
- ML20065P677 + (00:17:14, 17 December 2024)
- ML20065P678 + (00:17:14, 17 December 2024)
- ML20065P676 + (00:17:15, 17 December 2024)
- ML20065P669 + (00:17:20, 17 December 2024)
- ML20065P672 + (00:17:20, 17 December 2024)
- 05000325/LER-1982-104-03, /03L-0:on 821001,excess Flow Check Valve 1-B21-F047c Failed to Seat & Isolate as Required.Probably Caused by Line Crud Deposit in Valve Seat.Line Flushed & Valve Satisfactorily Tested + (00:17:22, 17 December 2024)
- AECM-82-472, Advises That Util Will Reissue Plant Emergency Operating Procedures in Accordance W/Inpo Writer Guide & Revision 2 of BWR Owners Group Emergency Planning Guidelines.Revised Procedures to Be Submitted by 821029 + (00:17:23, 17 December 2024)
- 05000325/LER-1982-104, Forwards LER 82-104/03L-0 + (00:17:24, 17 December 2024)
- ML20065P640 + (00:17:25, 17 December 2024)
- ML20065P644 + (00:17:25, 17 December 2024)
- ML20065P635 + (00:17:26, 17 December 2024)
- ML20065P632 + (00:17:27, 17 December 2024)
- 05000373/LER-1982-111-03, /03L-0:on 820927,high Airborne Activity Discovered in Radwaste Reboiler Room.Caused by Insufficient Weld Penetration of Tee Between Valves 1B21-F528 & 1B21-F532.Tee Cut Out & Replaced.Reboiler Returned to Svc + (00:17:29, 17 December 2024)
- 05000293/LER-1990-019, :on 901109,fire Dampers & Penetration Found Degraded in Intake Structure + (00:17:31, 17 December 2024)
- ML20065P619 + (00:17:33, 17 December 2024)