Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20069M219 + (15:21:48, 16 December 2024)
- ML20069M218 + (15:21:49, 16 December 2024)
- ML20069M217 + (15:21:49, 16 December 2024)
- 05000370/LER-1994-002-04, :on 940518,discovered That RCS Fluoride & Chloride Analysis Performed on 940513 Nonrepresentative of Typical Water Sample.Caused by Improper Work Practices. Chemistry Data Plot Data Reviewed for Validity + (15:21:51, 16 December 2024)
- 05000334/LER-1979-023, Forwards Updated LER 79-023/03X-1 + (15:21:55, 16 December 2024)
- ML20069M203 + (15:21:56, 16 December 2024)
- ML20069M200 + (15:21:57, 16 December 2024)
- 05000364/LER-1994-003, :on 940603,several MSSVs Found to Lift Settings Outside Tolerance Band.Caused by Inaccuracy in Mean Seat Area Term of Equation Used to Calculate Lift Setpoint for Furmanite Trevitest Sys.Trevitest Sys Revised + (15:21:58, 16 December 2024)
- ML20069M193 + (15:21:59, 16 December 2024)
- L-83-251, Final Deficiency Rept 83-009 Re Condensate Storage Tank Damage.Initially Reported on 830322.Caused by Condensation of Steam Creating Local Vacuum Conditions.Double Butt Welded Plates Installed,Cracks Sealed & Designs Improved + (15:22:00, 16 December 2024)
- ML20069M191 + (15:22:00, 16 December 2024)
- ML20069M189 + (15:22:01, 16 December 2024)
- ML20069M186 + (15:22:02, 16 December 2024)
- 05000325/LER-1994-003-02, :on 940603,repair Activities on Main Stack WRGM Sample Pump Inadvertently de-energized Monitor,Resulting in Unplanned Actuations W/Cis.Caused by Personnel Error.Mgt Expectations Reinforced + (15:22:03, 16 December 2024)
- ML20069M182 + (15:22:04, 16 December 2024)
- GO2-83-349, Part 21 Rept Re Linear Indications Identified in SA 106 Grade Pipe.Initially Reported on 830413.Caused by Mfg Process Error & Ultrasonic Exam Inadequacies.All Seamless Pipe Put on Hold & Magnetic Particle Examined + (15:22:05, 16 December 2024)
- ML20069M176 + (15:22:08, 16 December 2024)
- ML20069M172 + (15:22:09, 16 December 2024)
- BSEP-83-1260, Supplemental Response to Part 21 Rept Re Postulated Pipe Crack in Hpci,Rcic,Reactor Water Cleanup Sys & Main Steam Line Drains.Required Mods Will Be Installed to Meet Requirements of Environ Qualification Program + (15:22:10, 16 December 2024)
- ML20069M164 + (15:22:10, 16 December 2024)
- ML20069M152 + (15:22:11, 16 December 2024)
- ML20069M156 + (15:22:11, 16 December 2024)
- ML20069M145 + (15:22:12, 16 December 2024)
- ML20069M146 + (15:22:12, 16 December 2024)
- ML20069M144 + (15:22:13, 16 December 2024)
- 05000339/LER-1983-025-03, /03L-0:on 830331,w/unit in Mode 1,steam Generator B Water Level Channel 1 high-high Turbine Trip/Feedwater Isolation Setpoint Discovered Greater than Tech Spec Limit. Caused by Malfunctioning Comparator Card.Card Replaced + (15:22:16, 16 December 2024)
- ML20069M139 + (15:22:17, 16 December 2024)
- 05000339/LER-1983-025, Forwards LER 83-025/03L-0 + (15:22:20, 16 December 2024)
- ML20069M130 + (15:22:21, 16 December 2024)
- ML20069M133 + (15:22:21, 16 December 2024)
- 05000301/LER-1983-002, Forwards LER 83-002/01T-0 + (15:22:22, 16 December 2024)
- ML20069M126 + (15:22:23, 16 December 2024)
- ML20069M124 + (15:22:23, 16 December 2024)
- 1CAN118210, Forwards AR Nuclear One,Unit 1 Cycle 6 Reload Rept, Including Proposed Tech Spec Changes Required as Result of Reload + (15:22:24, 16 December 2024)
- ML20069M121 + (15:22:25, 16 December 2024)
- 05000296/LER-1983-023-03, /03L-0:on 830330,during Normal Operation,While Performing Surveillance Instruction SI 4.2.B-69,pressure Switch PS-3-204C Had as-found Setpoint of 1123 Psig.Caused by Instrument Drift.Switch Recalibr + (15:22:27, 16 December 2024)
- ML20069M118 + (15:22:28, 16 December 2024)
- ML20069M115 + (15:22:28, 16 December 2024)
- ML20069M110 + (15:22:29, 16 December 2024)
- 05000296/LER-1983-023, Forwards LER 83-023/03L-0 + (15:22:30, 16 December 2024)
- ML20069M106 + (15:22:30, 16 December 2024)
- ML20069M102 + (15:22:31, 16 December 2024)
- ML20069M104 + (15:22:31, 16 December 2024)
- ML20069M092 + (15:22:32, 16 December 2024)
- ML20069M096 + (15:22:32, 16 December 2024)
- ML20069M080 + (15:22:33, 16 December 2024)
- 05000327/LER-1983-045-03, /03L-0:on 830401,06 & 10,steam Generator 1 wide- Range Level Channel Declared Inoperable After Failing Low. Caused by Faulty Recorder 1-LR-3-43,probably Due to Defective Switches in Connector.Recorder Replaced + (15:22:35, 16 December 2024)
- ML20069M065 + (15:22:36, 16 December 2024)
- ML20069M064 + (15:22:37, 16 December 2024)
- 05000327/LER-1983-045, Forwards LER 83-045/03L-0 + (15:22:38, 16 December 2024)
- SNRC-2173, Forwards Termination Survey Final Rept Phase 3. Proprietary Pages to Rept Also Encl.Proprietary Pages Withheld (Ref 10CFR2.790) + (15:22:39, 16 December 2024)