- ML20072C489 + (10:44:31, 15 December 2024)
- ML20072C488 + (10:44:32, 15 December 2024)
- ML20072C486 + (10:44:32, 15 December 2024)
- 05000389/LER-1983-008-03, /03L-0:on 830514,while in Mode 3,operator Observed All Position Indication Lights on PORV 1475 Were Out.Caused by Loss of Magnetic Property to Magnet on Valve Shaft Due to High Temps in Environs.Magnet Replaced + (10:44:34, 15 December 2024)
- ML20072C484 + (10:44:35, 15 December 2024)
- PLA-1677, Interim Deficiency Rept Re Lack of Movement in Itt Grinnell Snubber Brackets.Initially Reported on 830429.All Snubbers Will Be Reinspected & Design & Installation Processes Under Review.Final Rept Due Oct 1983.Also Reported Per Part 21 + (10:44:35, 15 December 2024)
- ML20072C478 + (10:44:36, 15 December 2024)
- 05000275/LER-1983-010-03, /03L-0:on 830514,prior to Fuel Load,Power to All Main Control Room Annunciators Lost During Const in Annunciator Cabinets.Caused by Electrician Touching Hot Wire to Ground,Short Circuiting Panel + (10:44:37, 15 December 2024)
- DCL-89-155, Response to Re Backfitting of Nuclear Power Reactors + (10:44:39, 15 December 2024)
- ML20072C470 + (10:44:41, 15 December 2024)
- NG-94-2846, Responds to NRC Re Violations Noted in Insp Rept 50-331/94-12.Corrective Action:Tdap 1802.22 Conduct of Licensed Operator Requalification Training Was Revised + (10:44:41, 15 December 2024)
- ML20072C467 + (10:44:42, 15 December 2024)
- ML20072C464 + (10:44:43, 15 December 2024)
- ML20072C463 + (10:44:44, 15 December 2024)
- ML20072C454 + (10:44:45, 15 December 2024)
- ML20072C455 + (10:44:45, 15 December 2024)
- ML20072C453 + (10:44:46, 15 December 2024)
- ML20072C447 + (10:44:46, 15 December 2024)
- ML20072C446 + (10:44:47, 15 December 2024)
- ML20072C445 + (10:44:48, 15 December 2024)
- ML20072C443 + (10:44:49, 15 December 2024)
- ML20072C440 + (10:44:49, 15 December 2024)
- ML20072C439 + (10:44:50, 15 December 2024)
- ML20072C433 + (10:44:51, 15 December 2024)
- ML20072C434 + (10:44:51, 15 December 2024)
- ML20072C432 + (10:44:52, 15 December 2024)
- ML20072C429 + (10:44:53, 15 December 2024)
- ML20072C423 + (10:44:53, 15 December 2024)
- ML20072C414 + (10:44:54, 15 December 2024)
- ML20072C413 + (10:44:55, 15 December 2024)
- 05000335/LER-1983-007-03, /03L-0:on 830203,control Element Assembly 66 Dropped 56 Inches to Core.No Cause Found.Element Returned to Group Position & Normal Operation Resumed + (10:44:56, 15 December 2024)
- ML20072C410 + (10:44:57, 15 December 2024)
- ML20072C409 + (10:44:58, 15 December 2024)
- ML20072C408 + (10:44:58, 15 December 2024)
- ML20072C403 + (10:44:59, 15 December 2024)
- ML20072C399 + (10:45:00, 15 December 2024)
- 05000335/LER-1983-007, Forwards LER 83-007/03L-0 + (10:45:01, 15 December 2024)
- 05000387/LER-1983-079-03, /03L-0:on 830515,inboard & Outboard Dilution Flow Transmitters Found Valved Out.Caused by Personnel Error. Event Rept Given to Personnel & Will Be Discussed at Next Meeting + (10:45:02, 15 December 2024)
- RBG-10-416, Final Deficiency Rept Re Manitowac 4600 W Crane Tipping Forward & Causing Extended Boom to Strike Portion of Standby Cooling Tower Basin 1 Under Const.Initially Reported on 810421.Condition Not Reportable Per 10CFR50.55(e) + (10:45:03, 15 December 2024)
- ML20072C394 + (10:45:04, 15 December 2024)
- ML20072C392 + (10:45:05, 15 December 2024)
- 05000336/LER-1983-002-03, /03L-0:on 830127,discovered Surveillance for Charging Pump Operability Not Performed within Required Period.Caused by Personnel Error.Dept Instruction & Operator Reinstruction Instituted,Covering Surveillance Deadlines + (10:45:08, 15 December 2024)
- ML20072C389 + (10:45:09, 15 December 2024)
- 05000275/LER-1983-014-01, /01T-0:on 830526,during Adjustment of Limitorque Operator,Binding of Torque Switch Observed.Cause Under Investigation.Torque Switch Mounting Bolts Substituted for Original Bolts + (10:45:14, 15 December 2024)
- ML20072C382 + (10:45:15, 15 December 2024)
- ML20072C378 + (10:45:15, 15 December 2024)
- ML20072C376 + (10:45:16, 15 December 2024)
- 05000336/LER-1983-002, Forwards LER 83-002/03L-0 + (10:45:17, 15 December 2024)
- 05000289/LER-1983-015, :on 830611,oxygen Concentration in Miscellaneous Waste Storage Tank Gas Space Exceeded Tech Spec Limits. Nitrogen Used to Purge Oxygen from Sys & Reduce Concentration + (10:45:18, 15 December 2024)
- ML20072C373 + (10:45:19, 15 December 2024)
- 05000315/LER-1983-047-01, /01T-0:on 830525,during Audit,Discovered Testing of Steam Generator Stop Valve Not Performed During 830327 Startup.Caused by Ambiguous Due Dates on Status Upgrade Sheets.Lists Reviewed & Dates Clarified + (10:45:21, 15 December 2024)
- LD-83-020, Nonproprietary Response to NRC Questions for CESSAR-F Statistical Combination of Uncertainty in Thermal Margin Analysis for Sys 80 + (10:45:22, 15 December 2024)