- 05000280/LER-1983-034-03, /03L-0:on 830728,emergency Diesel 3 Inadvertently Removed from Svc.Caused by Misunderstanding Between Shift Supervisor & Const Electricians & Loss of Administrative Control.Diesel Returned to Svc + (07:34:02, 15 December 2024)
- ML20076H777 + (07:34:03, 15 December 2024)
- 05000277/LER-1983-013-03, /03L-0:on 830503,fluctuating Readings Observed on Iodine Monitor & Downscale Reading Found on Gas Monitor. Caused by Poor Connections in Drywell Air Sampling Radiation Detector Circuitry Due to Oxidation Buildup on Connector + (07:34:05, 15 December 2024)
- ML20076H773 + (07:34:06, 15 December 2024)
- ML20076H769 + (07:34:10, 15 December 2024)
- 05000296/LER-1983-043-03, /03L-0:on 830727,CAM3-90-256 Removed from Svc to Replace Sample Pump.Caused by Sample Pump Nearing End of Normal Svc Life.Sample Pump Replaced + (07:34:12, 15 December 2024)
- ML20076H764 + (07:34:13, 15 December 2024)
- 05000296/LER-1983-051-01, /01T-0:on 830812,control Valve Fast Closure/Stop Valve Scram Bypass Pressure Switches PS-1-81A & B & PS-1-91A & B Operated Above Tech Spec Limit.Caused by Calibr Drift.Switches Recalibr + (07:34:19, 15 December 2024)
- AECM-83-0329, Interim Deficiency Rept 3 Re Nelson Stud Failures on Type 86 Embed Plates.Initially Reported on 821221.Unit 1 Embed Plates Replaced W/Surface Mounted Plates.Final Rept to Be Submitted by 830705.Also Reported Per Part 21 + (07:34:20, 15 December 2024)
- ML20076H751 + (07:34:21, 15 December 2024)
- ML20076H749 + (07:34:22, 15 December 2024)
- ML20076H750 + (07:34:22, 15 December 2024)
- LIC-94-0177, Forwards Addl Info Requested to Assist in Closure of NRC GL 89-10 at Fort Calhoun Station + (07:34:29, 15 December 2024)
- 05000220/LER-1983-016-03, /03L-0:on 830718,during Normal Operations,Main Steam Line Radiation Monitor 122 Declared Inoperable After Displaying Low Readings Since 830717.Caused by Defective Detector Output Connector on Monitor 122 + (07:34:30, 15 December 2024)
- ML20076H736 + (07:34:32, 15 December 2024)
- ML20076H733 + (07:34:32, 15 December 2024)
- ML20076H728 + (07:34:33, 15 December 2024)
- ML20076H726 + (07:34:34, 15 December 2024)
- ML20076H721 + (07:34:35, 15 December 2024)
- ML20076H725 + (07:34:35, 15 December 2024)
- 05000416/LER-1983-064-01, /01T-0:on 830524,inconsistencies & Problems Associated W/Onsite Chlorine Storage Identified During Internal Review of Fsar.Caused by Lack of Administrative Controls + (07:34:37, 15 December 2024)
- ML20076H716 + (07:34:41, 15 December 2024)
- ML20076H711 + (07:34:43, 15 December 2024)
- ML20076H710 + (07:34:45, 15 December 2024)
- 05000293/LER-1983-044-03, /03L-0:on 830725,inboard MOV-1301-16 Did Not Close During RCIC Surveillance Test.Outboard Isolation Valve Closed & Sys Declared Inoperable.Caused by Defective Belleville Spring Pack.Motor Operator Rebuilt + (07:34:46, 15 December 2024)
- ML20076H708 + (07:34:47, 15 December 2024)
- 05000339/LER-1983-040-03, /03L-0:on 830518,during Refueling Outage,Type C Tests Revealed That 17 Containment Isolation Valves Exceeded Total Allowable Leakage.Caused by Dirt or Debris on Seating Surfaces.Seats Cleaned,Inspected & Repaired + (07:34:52, 15 December 2024)
- 05000348/LER-1983-041-03, /03L-0:on 830726,during Svc Water Bldg Battery Weekly Verification & on 830727,during Quarterly Verification,Train B Svc Water Battery Determined Inoperable Due to Cell 59 Having low-specific Gravity + (07:34:54, 15 December 2024)
- 05000261/LER-1983-010-01, /01T-0:on 830525,review of Eddy Current Data Revealed 137 & 206 Defective Tubes Identified in Steam Generators B & C,Respectively.All Defective Tubes Taken Out of Svc + (07:34:56, 15 December 2024)
- ML20076H701 + (07:34:57, 15 December 2024)
- ML20076H702 + (07:34:57, 15 December 2024)
- ML20076H699 + (07:34:58, 15 December 2024)
- ML20076H698 + (07:34:58, 15 December 2024)
- B10802, Advises of QA Verification of Re Reevaluation of Steam Generator Tube Rupture Event in Support of Cycle 6 Operation.Verification Confirms Conclusions + (07:34:59, 15 December 2024)
- ML20076H693 + (07:35:00, 15 December 2024)
- ML20076H691 + (07:35:00, 15 December 2024)
- 05000389/LER-1983-010-03, /03L-0:on 830511,power Lost to Side B Vital & Nonvital Buses.Caused by Opening Incorrect Breaker at Distribution Switchyard.Personnel Instructed on Importance of Proper Switching + (07:35:05, 15 December 2024)
- ML20076H685 + (07:35:08, 15 December 2024)
- 05000317/LER-1983-039-03, /03L-0:on 830722,during Normal Operation,Control Room Air Conditioner (Crac) 12 Compressor Tripped,Rendering Crac 12 Inoperable.Caused by Loose Condenser Fan Belts Tripping Compressor on High Discharge Pressure + (07:35:12, 15 December 2024)
- 05000339/LER-1983-064-03, /03L-0:on 830731,emergency Condensate Storage Tank Dropped Below 110,000 Gallons When Auxiliary Feedwater Pumps in Operation Following Reactor Trip.Caused by low-low Steam Generator Level Signal.Level Restored + (07:35:14, 15 December 2024)
- 05000366/LER-1983-074-03, /03L-0:on 830726,during Maint,Hydrogen/Oxygen Analyzer 2P33-P001B Declared Inoperable Due to Erratic Operation.Caused by Worn Diaphragms in Diaphragm Pump.Worn Diaphragms Replaced + (07:35:16, 15 December 2024)
- PY-CEI-NRR-0050, Clarifies Commitment to Perform Addl Start & Load Qualification Testing on Standby Diesel Generators,As Outlined in SER Section 8.3.1.Total of 20 Addl Tests Will Be Conducted + (07:35:17, 15 December 2024)
- 05000395/LER-1983-089-03, /03L-0:on 830815,while in Mode 1,temp Indicator Declared Inoperable Due to Erratic Indication Causing Loop B Overtemp Delta Temp to Alarm.Caused by Spiking Originating in Isolation Amplifier.Amplifier Replaced + (07:35:19, 15 December 2024)
- ML20076H671 + (07:35:20, 15 December 2024)
- 05000366/LER-1983-065-03, /03L-0:on 830721,QA Audit of Surveillance Procedures Revealed That Changes to Core Spray Logic Sys Functional Test Procedure HNP-2-3204 Made Improperly.Caused by Personnel Error.Rev Will Be Made Properly + (07:35:22, 15 December 2024)
- ST-HL-AE-4909, Monthly Operating Repts for Sept 1994 for South Texas Project Electric Generating Station + (07:35:26, 15 December 2024)
- ML20076H667 + (07:35:26, 15 December 2024)
- 05000366/LER-1983-034-01, /01T-0:on 830525,select Isotopes Identified But Omitted from Process Computer E BAR Library When Program Originally Initiated.Caused by Incorrect Computer Program. Library Will Be Corrected + (07:35:28, 15 December 2024)
- ML20076H658 + (07:35:29, 15 December 2024)
- 05000324/LER-1983-049-03, /03L-0:on 830511,main Steam Line Channel Instrument 2-D12-RM-K603D Found Actuating Out of Specified Tolerances.Caused by Zener Diode VR5 Failure in Channel Instrument drawer.VR5 Replaced + (07:35:31, 15 December 2024)