Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- LIC-95-0018, Forwards OPPD Annual Accounting for Period of Jan-Dec 1994, as Required by FCS Decommissioning Funding Plan Trust Agreement + (05:31:29, 15 December 2024)
- ML20078J978 + (05:31:30, 15 December 2024)
- ML20078J977 + (05:31:30, 15 December 2024)
- ML20078J972 + (05:31:31, 15 December 2024)
- ML20078J930 + (05:31:32, 15 December 2024)
- NRC-94-0120, Forwards Rev 0 to Fermi 2 COLR Cycle 5 + (05:31:32, 15 December 2024)
- ML20078J926 + (05:31:33, 15 December 2024)
- 05000416/LER-1995-001, :on 950106,discovered That 25% Grace Period for I&C Quarterly Surveillance 06-IC-1C51-Q-0001 Attachment IV Missed by Four Days.Ts 4.0.3 Initiated & Surveillance Successfully Performed + (05:31:34, 15 December 2024)
- BECO-94-124, Advises That Shroud Repair Plans & Analysis Will Be Submitted to NRC for Review & Approval No Later than 950116 + (05:31:36, 15 December 2024)
- ML20078J923 + (05:31:36, 15 December 2024)
- ML20078J883 + (05:31:37, 15 December 2024)
- ML20078J881 + (05:31:38, 15 December 2024)
- ML20078J878 + (05:31:38, 15 December 2024)
- ML20078J869 + (05:31:39, 15 December 2024)
- ML20078J874 + (05:31:39, 15 December 2024)
- NRC-95-4391, Forwards non-proprietary WCAP-14271 & Proprietary WCAP-14270 AP600 Low Pressure Integral Sys Test at or State Univ, Facility Scaling Rept. Rept WCAP-14270 Withheld (Ref 10CFR2.790) + (05:31:41, 15 December 2024)
- ML20078J864 + (05:31:41, 15 December 2024)
- ML20078J853 + (05:31:42, 15 December 2024)
- ML20078J847 + (05:31:43, 15 December 2024)
- U-602407, Responds to NRC 941228 RAI on Potential Concern Re Requirements for Inoperable ECCS Actuation Instrumentation During Plant Shutdown Conditions,Per Review of Util Request to Implement Improved TS + (05:31:43, 15 December 2024)
- ML20078J846 + (05:31:44, 15 December 2024)
- 05000328/LER-1983-121-03, /03L-0:on 830911,during Mode 5,lower Containment Airlock Failed Overall Leakage Test SI-159.1.Caused by Leakage Through Four Handwheel Packings Due to Normal Wear. Doors Overhauled + (05:31:45, 15 December 2024)
- ML20078J834 + (05:31:47, 15 December 2024)
- ML20078J827 + (05:31:47, 15 December 2024)
- ML20078J822 + (05:31:48, 15 December 2024)
- 05000306/LER-1983-022-03, /03L-0:on 830909,steam Flow Transmitter Found Out of Calibr Low by 1%.Cause Unknown.Transmitter Returned to Vendor for Analysis.Rosemount Model 1153HA6 Differential Pressure Transmitter Replaced + (05:31:49, 15 December 2024)
- ML20078J810 + (05:31:51, 15 December 2024)
- ML20078J798 + (05:31:51, 15 December 2024)
- ML20078J797 + (05:31:53, 15 December 2024)
- ML20078J779 + (05:31:54, 15 December 2024)
- ML20078J772 + (05:31:55, 15 December 2024)
- ML20078J760 + (05:31:58, 15 December 2024)
- ML20078J750 + (05:31:58, 15 December 2024)
- ML20078J747 + (05:31:59, 15 December 2024)
- BECO-LTR-95-010, Identifies Instances in Addition to Those Reported in Previous Correspondence,Informing NRC of Instances in Which Util Actual Corrective Actions for Dcrdr Project Differed Substantially from C/A Reported in Final Summary Rept + (05:32:00, 15 December 2024)
- ML20078J746 + (05:32:00, 15 December 2024)
- ML20078J736 + (05:32:01, 15 December 2024)
- ML20078J735 + (05:32:01, 15 December 2024)
- 05000328/LER-1995-001, :on 950105,turbine Tripped Followed by Reactor Trip.Caused by Pressure Surges in Transformer Cooling Oil, Actuating gas-operated Relay.Cr Personnel Responded as Prescribed by Emergency Procedures + (05:32:07, 15 December 2024)
- ML20078J718 + (05:32:08, 15 December 2024)
- 05000316/LER-1983-092-01, /01T-0:on 830926,during Routine Sampling of Boron Injection Tank,Sampling Valves at Tank Outlet Left Partially Open.Caused by Personnel Error.Appropriate Administrative Actions Taken Against Individual Involved + (05:32:09, 15 December 2024)
- ML20078J699 + (05:32:11, 15 December 2024)
- ML20078J703 + (05:32:11, 15 December 2024)
- ML20078J691 + (05:32:12, 15 December 2024)
- ML20078J688 + (05:32:13, 15 December 2024)
- ML20078J680 + (05:32:17, 15 December 2024)
- ML20078J683 + (05:32:17, 15 December 2024)
- ML20078J679 + (05:32:18, 15 December 2024)
- 05000373/LER-1995-001-01, :on 950106,RHR Instrument Root Valve Was Found Closed.No Specific Cause Could Be Determined.Functional Test Satisfactorily Completed & Switch Restored to Proper Unisolated Condition + (05:32:19, 15 December 2024)
- ML20078J673 + (05:32:20, 15 December 2024)
- 05000327/LER-1983-119-03, /03L-0:on 830910,containment Internal Pressure Limit for Annulus Pressure Exceeded.Caused by Normal Air Leakage Into Containment W/O Venting.Containment Pressure Returned to within Limit + (05:32:22, 15 December 2024)
- 05000321/LER-1983-096-01, Drywell Svc Air Primary Containment Inboard Isolation Valve 1P51-F514 Opened During Plant Shutdown & Not Closed Prior to Startup on 830618. Caused by Procedural Inadequacy.Valves Closed + (05:32:30, 15 December 2024)